DOI QR코드

DOI QR Code

A research on the design parameters for a double-transmission main system for sustainable water supply

이중송수관로를 이용한 안정적인 송수를 위한 설계인자에 관한 연구

  • 현인환 (단국대학교 토목환경공학과) ;
  • 홍준의 (단국대학교 토목환경공학과) ;
  • 김두일 (단국대학교 토목환경공학과)
  • Received : 2013.01.03
  • Accepted : 2013.02.14
  • Published : 2013.02.15

Abstract

Water interruption is often caused by a rupture in the branch-like singular pipeline. This will cause critical complaints from household and may decrease public service quality. As an alternative of singular pipeline, additional parallel pipeline could be installed for sustainable water supply. This system is called double pipeline system and able to be utilized for water transmission line between treatment plant and distribution reservoir. Construction of double pipeline was thought to increase capital cost, which can be an issue to waterworks authorities. Reducing capital cost was possible by means of installing connectors between two parallel pipelines because of reduced diameter of each pipe. To obtain optimal design condition for connectors, it was necessary to compare water pressure according to accident location, to investigate flow according to connection pipe spacing, connection pipe diameter, and aging of pipe. Reliable and economical connection layouts were determined based on these results. The cost estimation for each design condition was carried out. Cost was approximately reduced by 20 ~ 30 % compared to the double pipeline without connections. In addition to this, connection between double pipelines could expect extra benefits for maintenance since the pipe could be repaired and rehabilitated without interruption.

Keywords

References

  1. EPA(2000) EPANET2 USERS MANUAL
  2. K-water(2009), Customer-centric may system rebuild a Study. Republic of Korea, 105-141
  3. Lee,Sangmok(2003) Analysis of Water Distribution Networks considering Correlation between Pressure and Water Demand under Low Pressure Conditions. A doctoral dissertation, Dankook university, Republic of Korea
  4. Mays, L.W.(2003) Water supply systems security. McGRAW-HILL
  5. Ministry of Environment(2010), waterworks 2010, Republic of Korea, 745-753
  6. Tethuo Takakuwa (1978) Analysis and Design of Water Distribution Network. Morikata Publishing Co. JAPAN
  7. Thomas M. Walski(1984) Analysis of Water Distribution Systems. Van Nostrand Reinhold Company
  8. Water and Wastewater Association(2008), Water Facility Disaster Prevention Research. Republic of Korea, 1-10

Cited by

  1. Experiment on Surface Water Pretreatment by Biological Contact Oxidation Process Filled with Modified Suspending Biochemical Packing vol.186, pp.1755-1315, 2018, https://doi.org/10.1088/1755-1315/186/3/012054