• Title/Summary/Keyword: water supply plant

Search Result 357, Processing Time 0.028 seconds

Analysis of Operating and Maintenance Parameters for Agricultural Pipeline System Using EPANET (EPANET을 이용한 농업용 관수로 시스템의 운영 및 유지관리 인자 분석)

  • Kim, Nam Do;Kim, Sun Joo;Kwon, Hyung Joong;Kim, Phil Shik;Park, Hyun Jun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.4
    • /
    • pp.17-26
    • /
    • 2017
  • In this study, EPANET model which is using on the pipe network analysis was applied to Haenam irrigation district has provided irrigation water by pipeline system about 1,125ha and then have built pipe network to study area and supply performance evaluation of existing structure was analyzed by SPA (Single Period Analysis) in EPANET. As model results of simulation average ratio of maximum supply quantity/irrigation water requirements(base demand) was analyzed by 2.63. It means also that was analyzed as being capable of ensuring the water supply capacity. It was provided the necessary information for the maintenance facility through analyzed hydraulic behaviors in the pipeline inside such as flow velocities, pressures and hydraulic grade lines. It was satisfied with the allowable design criteria that was compared analyzed results with presented allowable design standards at agricultural production infra improvement project planning and design (Pipeline design standard). In order to analyze efficiency promotions of irrigation water, using Extended Period Simulation it was compared supply quantity with irrigation water requirements while pumps set operating pattern in 24 hours, then efficiency promotions of irrigation water was determined through analyzed oversupply water quantity and occurrence time by branch lines. According to results for oversupply quantity in Haenam district by time and end of branch lines efficiency promotions of irrigation water was suggested from 0.33 % to 37.59 %. To draw reasonable operating rules for water use and through this research, it is expected to be helpful for efficient water use and operational management of agricultural pipeline system to the current agricultural irrigation.

Comparison of Quality and Cell Enlargement of 'Nero' Black Chokeberry Fruits According to Different Soil Water Conditions (토양수분 조건에 따른 블랙쵸크베리 'Nero' 과실의 품질 및 세포 발달 비교)

  • Won, Jungyeon;Shin, Hyunsuk;Oh, Youngjae;Han, Hyeondae;Kim, Keumsun;Oh, Sewon;Kim, Daeil
    • Korean Journal of Plant Resources
    • /
    • v.30 no.1
    • /
    • pp.88-95
    • /
    • 2017
  • Effects of different soil water conditions on fruit characteristics were investigated in 5-year-old 'Nero' black chokeberry trees (Aronia melanocarpa). Three kinds of drought stresses, including low water deficit, severe water deficit, and very severe water deficit, due to decline of soil water decreased the fruit quality of weight of 10 berries, soluble solid content, and anthocyanin, compared with the control (consistent water supply) during the harvest period. After longer drought stress, supply of soil water could induce berry cracking because cell size of epidermis of fruits contracted, whereas cell size of sub-epidermis and flesh expanded. Thus periodic water supply using water supply facility is needed for yield and quality of 'Nero' black chokeberry fruits.

A Study of Potable Water Disinfection for National Health (수돗물 살균제가 국민보건에 미치는 영향에 관한 연구)

  • Shin Soo Ok
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.1
    • /
    • pp.31-38
    • /
    • 1996
  • Disinfection is a very important process in water plant on account of our surface water usage. Particularly. the rainfall of Korea is concentrated in summer time. it is almost carried away to ocean before our utilization as water resource. To overcome the unbalance of water resource, artificial dams and reservoirs are constructed. According to such storage of water to aggravate water pollution and make the increase of water cleaning chemicals. Chlorine, as a main traditional chemical for water treatment. is focused on account of THMS formation in recent days. In this paper. the data of a water plant located in Seoul is adopted as the foundation of water quality analysis and introduce the substitute chemicals to supplement the harmful formation. additionally. Conclusions are summarized as follows: 1. The water quality of water resource is the worst in summer time and the supply of cleaning chemical is inevitably increased on account of general bacteria increase. 2. Chlorine, as a main chemical for water cleaning, formed the cancer-causing organic THMS with water molecules. 3. One of substitute chemical. chlorine dioxids suppress the formation of THMS comparing with the case of chlorine only. Therefore. the continuous research of substitute chemicals should be activated. 4. As the supply of disinfected clean water concerned with the citizen sanitary, the cultivation of professionals and academic conference must be needed on the basis of nation

  • PDF

Difference in Shoreline Flora According to the Usage of Reservoirs in Korea (우리나라 저수지의 용도에 따른 호안 식물상 차이)

  • Cho, Hyunsuk;Cho, Kang-Hyun
    • Journal of Wetlands Research
    • /
    • v.17 no.4
    • /
    • pp.339-347
    • /
    • 2015
  • Differences in characteristics of flora and environmental factors of geomorphology, hydrology, water quality and soil were investigated in the shoreline of total 35 reservoirs according to their usages of waterpower generation, agricultural water supply, residential and industrial water supply and flood control in Korea. The number of plant species, floral structure and characteristics of species traits in the shoreline of reservoirs were different according to their usage. From the results of stepwise regression analysis, the total number of vascular plant species was increased at the environment of the higher flood frequency at the median water level and the longer exposure duration of the shoreline. The results of principal coordinates analysis and cluster analysis showed that the shoreline flora was classified as the 3 types of 1) flood control and residential and industrial water supply, 2) agricultural water supply and 3) waterpower generation reservoirs. The water level fluctuation, flood frequency at the median water level, lake water quality index and exposure duration of the shoreline were selected as important environmental factors affected on the characteristics of shoreline flora. The species richness of total flora and hydrophytes, especially submerged macrophytes, were much higher in the reservoirs for the purpose of the waterpower generation in which mesotrophic water quality and stable water levels were maintained. Annual or biennial ruderals were established on the ephemeral drawdown zone of flood control, residential and industrial water supply reservoirs which have oligotrophic or mesotrophic water quality and wide range of water level fluctuation. The floating hydrophytes were differentially dominated in the littoral zones of the agricultural water supply reservoirs with a mesotrophic or eutrophic water quality and a medium water level fluctuation. In conclusion environmental factors related to water level fluctuation and water quality were different and then the floral characteristics of shoreline were distinguishable according to usage of Korean reservoirs.

A study on Water Quality Changes in Distribution System (Factor analysis of deterioration of water quality & Modelling of free chlorine) (상수도 배관망에서의 수질변화에 관한 연구 (수질악화의 영향인자 분석과 잔류염소 모델링))

  • Lee, Hyun Dong;Chung, Won Sik;Moon, Sook Mi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.59-66
    • /
    • 1997
  • Although it produces well-treated water in water treatment plant, water quality at the tap can be changed depending on the state of pipes. It is because water quality deteriorates as plant water passes through pipeline networks. Therefore, the improvement of not only water treatment technology but also O & M of water pipelines is required to supply good water to consumers. The purpose of the study was to obtain the basic data of control technology for water quality in pipes through investigating water quality in distribution system. We selected 11 sampling sites and investigated water quality from plant to endpoint of distribution system. we also simulated decreasing tendency of free chlorine through pipeline network. As the result of water quality test, all parameters were below allowable levels, but some parameters had the possibility of being over levels. So there must be more work to set up proper countermeasure for violable parameters.

  • PDF

Technical Trend of Seawater Desalination Plant Using Renewable Energy (신재생에너지를 활용한 해수담수화플랜트 개발동향과 전망)

  • Choi, Jae-Baek;Jeong, Chang-Hee;Park, Seung-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1368-1369
    • /
    • 2011
  • 이 연구는 최근 물 부족시대를 대비한 차세대 기술로 각광 받고 있는 해수담수화설비의 동력을 기존의 화석연료에서 신재생에너지로 전환하고 있는 세계적인 추세와 기술동향을 살펴보고 국내 적용 가능성을 검토한 것이다. 특히 태양열, 태양광, 풍력 등을 활용하여 MENA(Middle East Asia & North Africa), 스페인, 지중해 연안 등의 지역에서 추진 중인 프로젝트의 성과를 살펴보고, 이를 토대로 극심한 물 부족으로 불편을 겪고 있는 국내 해안 도서지역에 적용할 수 있는 방안을 검토하였다.

  • PDF

The Optimum Control Study for Improving Efficiency of the Small Hydropower Generation in Water Pipe (수도관로 소수력발전 운영효율 향상을 위한 최적제어 방안)

  • Hong, Jeong-Jo;Rim, Dong-Heui;Kim, Soo-Sang
    • New & Renewable Energy
    • /
    • v.4 no.2
    • /
    • pp.31-38
    • /
    • 2008
  • Using a surplus head in presented water supply pipes, we have studied to improve the operating efficiency of small hydro generator, which was chosen for a test model with 00 hydro power plant. With regard to power control and countermeasure of water hammer impact, Finally we have represented the optimal control method through the synthetical analysis of existing system symptoms, operation efficiency, the effect of water hammer impact and system configuration.

  • PDF

Evolution of Water supply system! Smart Water Management for customer - Smart Water City Pilot Project - (수도 서비스의 진화! 소비자 중심의 스마트 물 관리 - Smart Water City 시범사업 -)

  • Kim, Jae-Bog
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.4
    • /
    • pp.511-517
    • /
    • 2015
  • Korea's modern waterworks began with construction of DDukdo water treatment plant in 1908 and has been growing rapidly along with the country's economic development. As a result, water supply rates have reached 98.5% based on 2013. Despite multilateral efforts for high-quality water supply, such as introduction of advanced water treatment process, expansion of waterworks infrastructure and so on, distrust for drinking tap water has been continuing and domestic consumption rate of tap water is in around 5% level and extremely poor comparing to advanced countries such as the United States(56%), Japan(52%), etc. Recently, the water management has been facing the new phase due to water environmental degradation caused by climate change, aging facilities, etc. Therefore, K-water has converted water management paradigm from the "clean and safe water" to the "healthy water" and been pushing the Smart Water City(SWC) Pilot Project in order to develop and spread new water supply models for consumers to believe and drink tap water through systematic water quality and quantity management combining ICT in the whole water supply process. The SWC pilot projects in Pa-ju city and Go-ryeong county were an opportunity to check the likelihood of the "smart water management" as the answer to future water management. It is needed to examine the necessity of smart water management introduction and nationwide SWC expansion in order to improve water welfare for people and resolve domestic & foreign water problems.

Status of Membrane Filtration in Japan : Application for Water Supply

  • Minami, Katsuyoshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.55-62
    • /
    • 1997
  • In Japan, the membrane filtration is becoming a common technology for municipal water supply system especially for small plant. 6 years before (1991), the national research project of membrane filtration for small plant has started. The project was named as "MAC 21", MEMBRANE AQUA CENTURY 21. In the project the Ministry of Health and Welfare, 8 universities and 18 water treatment plant companies have been involved. This was the first attempt to research a common theme in joint with government, universities and private companies. After three years, the guide line for membrane filtration application for small plant has been established. This has promoted to install some actual plant. And also, another joint research for "RESEARCH OF MEMBRANE FILTRATION FOR ADVANCED WATER TREATMENT" has started in 1994 and completed in March, 1997. The project was named as MAC21. In the former project the main objectives were removal of turbidity and bacteria from water. However, in new project the objective was establishment of the further advanced membrane filtration technology which would be applicable for trace chemical components removal such as tri-halo-methane pre-courser, agricultural chemicals removal, offensive smell and taste removal and virus removal. For the objectives, application of nanofiltration and hybrid-system, a combination of micro-filtration ultra-filtration with biological, ozone and activated carbon treatment process have been studied. In addition, application of membrane filtration for treatment of back-wash waste water originated from membrane filters and conventional sand filters has.been studied. At the end of March of this year, about 30 membrane filtration plants are actually supplying the water, the total treatment capacity is about 6,000 m$^{3}$/day and another 20 will be installed within one year.led within one year.

  • PDF

Development of the method for optimal water supply pump operation considering disinfection performance (소독능을 고려한 송수펌프 최적운영기법 개발)

  • Hyung, Jinseok;Kim, Kibum;Seo, Jeewon;Kim, Taehyeon;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.421-434
    • /
    • 2018
  • Water supply/intake pumps operation use 70~80% of power costs in water treatment plants. In the water treatment plant, seasonal and hourly differential electricity rates are applied, so proper pump scheduling can yield power cost savings. Accordingly, the purpose of this study was to develop an optimal water supply pump scheduling scheme. An optimal operation method of water supply pumps by using genetic algorithm was developed. Also, a method to minimize power cost for water supply pump operation based on pump performance derived from the thermodynamic pump efficiency measurement method was proposed. Water level constraints to provide sufficient disinfection performance in a clearwell and reservoirs were calibrated. In addition, continuous operation time constraints were calibrated to prevent frequent pump switching. As a result of optimization, savings ratios during 7 days in winter and summer were 4.5% and 5.1%, respectively. In this study, the method for optimal water pump operation was developed to secure disinfection performance in the clearwell and to save power cost. It is expected that it will be used as a more advanced optimal water pump operation method through further studies such as water demand forecasting and efficiency according to pump combination.