• Title/Summary/Keyword: water spray head

Search Result 27, Processing Time 0.022 seconds

The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head (소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구)

  • 추병길;최종욱;차경세
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF

Analysis of Water Flux Uniformity for Various Fire Sprinkler Head Type (화재 진압용 스프링클러 헤드 유형에 따른 살수 균일도 분석)

  • Saemi Bang;Chanseob Ahn;Taehoon Kim
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.97-104
    • /
    • 2023
  • A sprinkler is a fire suppression system that extinguishes combustible materials in the early stages of a fire, creating a spray. However, spray formation method of the sprinkler can result in an uneven distribution of water spray on the surface of combustible materials. It is necessary to ensure a consistent water flux density regardless of the spray direction and angle. In this study, the water flux distribution was analyzed for the various types of sprinkler head: circular, flush, pendent, and upright types. All sprinkler heads have a K-factor of 80 LPM/(0.1MPa)0.5. In this study, water collection cubes were used to examine the water flux distribution. The upright type sprinkler head showed a low standard deviation in total sprayed area, indicating a high level of uniformity. The upright type head showed the lowest standard deviation in the radial direction, and also showed the lowest standard deviation in the azimuthal direction. Upright sprinkler head has no obstructing structure along the path of droplets after they are generated. For this reason, upright sprinkler head showed the most uniform water flux distribution on the floor.

Spray Characteristics of In-Rack Sprinkler Heads (인랙스프링클러 헤드의 살수 특성)

  • Kim, Jong Hoon;Joung, Woo In;Myoung, Sang Youb;Jeong, Keesin;Kim, Woon Hyung
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2017
  • The aim of this study is to find out the water spray features of in-rack sprinklers for rack storage. This study conducted cold water flow test, measurement of spray angle and densities by angles for sprinkler head manufactured by a Korean company and a U.S. company. Korean sprinkler head had a wide angle of water spary. The water spray angle of a U.S. sprinkler head was narrow compared to the Korean sprinkler. In comparison of the Korean head with U.S. head of the same K80, the Korean head can send water to parts that are difficult to directly spray, but the spraying density by angle was low. U.S. head can send more water than Korean head at a narrow angle. In conclusion, for flammable materials placed in two or more rows in a rack storage, a zigzag arrangement with face sprinklers will be effective.

Directional Water Spray Characteristics of Sprinkler Heads (스프링클러 헤드의 방향성 살수 특성 비교 연구)

  • Park Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.35-41
    • /
    • 2004
  • The water spray characteristics of the sprinkler heads is a very important factor affecting the fire suppression performance, and it is largely dependent on the shape of the head nozzle. This study investigated shape factors and spray distribution performances for the sprinkler heads of four domestic companies with big market shares. The experimental results revealed that all flow constants exceeded the required regulation limits, however showed big differences between head types although they have the same design limit. They were however relatively consistent regardless of the pressure increases. The spray distribution of some head samples showed severe directional eccentricity, which suggests more study for the improvement.

Experimental study on the spray density distribution of water spray system in road tunnel (터널 물분무소화설비의 살수밀도분포에 대한 실험연구)

  • So, Soo-Hyun;Park, Kyung-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Spray density of the water spray system which is installed in long road tunnels and hazardous vehicle tunnels is applied without proper performance assessment process. In this study, the requirements of Spray Density Guidelines at the standard pressure is investigated through spray test set up the nozzle of a water spray system in a simulated road tunnel. The results showed that all the nozzles used in the test area did not meet the requirements of the Guidelines. The absence of performance test codes and inspection process on the nozzle at real scale in tunnels may have caused this practice. Therefore, it is suggested that the performance test regulations of the nozzle on the water spray system is established in order to properly assess the system performance.

An Experimental Study on the Effects of the Shape of a Drencher Head on the Characteristics of a Water Curtain (드렌처 헤드의 형상에 따른 수막특성에 관한 실험적 연구)

  • Lee, Seung-Chul;Kim, Bong-Jun;Lee, Jae-Ou;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.86-93
    • /
    • 2016
  • The effects of the shape of a drencher head on the flow characteristics and radiation attenuation of a water curtain, in order to prevent a fire spread, were experimentally studied. The distance (h) between the orifice exit and deflector and the diameter of deflector (D) were varied as the shape factors of the head, with the same orifice diameter (d). It was found that an increase in h leads to an increase in the water flow rate and spray angle. However, the change in the spray angle decreases with increasing D. Increasing D brings about a subtle increase in the water flow rate and a significant decrease in the spray angle. A larger value of D makes it possible to produce a flatter pattern of the water curtain, but reduces the uniformity of the droplets inside the spray angle. The mean droplet diameter decreases significantly as the operating pressure increases. However, the variation in the shape of the drencher head does not significantly affect the change in the mean diameter at the same operating pressure. Finally, it was found that the radiation attenuation afforded by the water curtain at the same operating pressure was affected by water flow rate and droplet uniformity, which were determined by h and D, respectively.

A Study on Ultrasonic Effects for the Atomization in a Twin-Fluid Spray (2-유체 분무에서 액체미립화에 대한 초음파의 영향에 관한 연구)

  • Ju, E.S.;Chung, J.D.;Song, M.G.
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.50-57
    • /
    • 1998
  • The utilization of resonance should be considered to get the maximum effect of ultrasonic to atomize liquid. The ultrasonic generator, transducer, horn, and all attached parts are used to produce the resonance, and specially the characteristics of liquids such as liquid load, property, and etc., for the liquid atomization affinity are considered. In this study, the variable device of liquid load was made and distilled water and city water selected as experimental liquids were sprayed by a twin-fluid spray method and their diameters, distributions, and spray quantum of spray droplets were measured by the light scattering system. And all data were observed, compared and considered relatively. In results, a lot of phenomena of liquid atomization affinity by ultrasonic appeared in accordance with liquid loads, namely head h.

  • PDF

Experimental Study on Spray Performance of Nozzles for Autonomous Fire Fighting Monitor (자율형 소화모니터 노즐의 분사 성능에 대한 실험 연구)

  • Rhyu, SeongSun;Kim, HyoungTae;Seo, JeongHwa
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.59 no.2
    • /
    • pp.80-88
    • /
    • 2022
  • A systematic experimental study is carried out for the fire fighting monitor nozzle of 65A diameter to design and manufacture a new nozzle with better water spray performance than available domestic nozzles. The nozzle inlet pressure, flow rate and reach for the discharged water from the nozzle are measured by utilizing the experimental facility consisting of two pumps and piping system with a flow meter and pressure gauges. It was found that the baffle position and baffle head chamfering were the most sensitive design factors to be remarkably changed in the flow rate of the discharged water. Also, It was confirmed that the baffle position and the water exit area had the significant effect on the change in reach distance. The results obtained from this study are expected to be used effectively to design new nozzles with excellent spray performances and also to validate numerical analysis results for evaluating the water spray performance of fire fighting monitor nozzles.

Study on Spray Atomization Characteristics Depending on the Operating Parameters of Urea Injector (요소수 인젝터의 작동 변수에 따른 분무미립화 성능에 관한 연구)

  • Kim, Donghwan;Park, Junkyu;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • This study was carried out to analyze the spray characteristics as a function of the operating parameters of urea injector used in Urea-SCR system of passenger diesel vehicle. Spray visualization and PDPA experiment were performed to analyze the macroscopic spray development and atomization performance of urea-water-solution. For the urea injector, the deformation of the spray head does not appear to be significant because it operates at a low pressure conditions, and the liquid core and primary droplet are observed throughout the operating conditions. No increase in atomization is seen when the operating pressure is increased, and the spray develops linearly due to poor atomization characteristics. The macroscopic spray behavior of the low-pressure urea injector is predictable through the modification of the Hiroyasu equation.

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.