• 제목/요약/키워드: water samples

검색결과 6,019건 처리시간 0.038초

당귀 열수 추출물을 이용한 막걸리의 품질 특성 (Quality Characteristics of Makgeolli using Angelica gigas Nakai Water Extracts)

  • 이장미;이하나;장윤희
    • 동아시아식생활학회지
    • /
    • 제23권3호
    • /
    • pp.332-340
    • /
    • 2013
  • The aim of this study was to investigate the quality characteristics of makgeolli that was produced by using different percentages (control, 3%, 5%, 7%, 9% by rice weight) of Angelica gigas Nakai water extracts during fermentation at $25^{\circ}C$ for 7 days. Yeast cell count in makgeolli steadily increased and showed the highest value at day 4 of fermentation, since then, the count decreased consistently. The final alcohol contents were higher than 15% in all samples. Soluble contents and antioxidation activity were significantly increased in percentage as Angelica water extracts increased (p<0.05). As the amount of Angelica water extracts increased, total polyphenol contents increased as well. Soluble contents and total polyphenol contents were increased according to the fermentation period. Total acidity increased up to day 3, but slowly decreased afterwards. However, the pH rapidly decreased by day 3, but then increased steadily. Reducing sugar amount was increased sharply by day 2 of fermentation and then, diminished gradually. Hunter's color value was not significantly different among samples however, they were significantly different between day 2 samples of fermentation and day 3 or more samples (p<0.05). In sensory evaluations, the sample produced using 5% Angelica water extracts received the highest score in herbal flavor, herbal taste, sourness, sweetness, and overall acceptance. Makgeolli using Angelica gigas Nakai water extracts showed excellent characteristics in antioxidative activity and higher total polyphenol content. Makgeolli produced using 5% Angelica water extracts received the highest score in sensory evaluation. Therefore, makgeolli produced using 5% Angelica water extracts was considered to be the most suitable for manufacturing makgeolli.

Method for Simultaneous Determination of Anatoxin-a and Microcystins in Korean Water Systems by Using LC/MS/MS

  • Moon, Jeong-Suk;Kim, Hwa-Bin;Park, Hae-Kyung;Lee, Jae-Jung;Park, Jong-Hwan;Lee, Hae-Jin
    • 생태와환경
    • /
    • 제44권1호
    • /
    • pp.22-30
    • /
    • 2011
  • This study was purposed to develop an effective LC/MS/MS method for simultaneously determining five pre-treated cyanotoxins (anatoxin-a, microcystins-RR, -YR, -LR and -LA) of cyanobacteria blooms. Cyanobacterial bloom samples were collected from 11 major lakes and three downstream areas of river around Korea during 2005~2009. Cyanotoxins were identified in 38 samples from the lakes. The validity of the method was evaluated and the recovery rates were found ranging from 83~87%. The MDL turned out to be $0.046\;{\mu}g\;L^{-1}$ for anatoxin-a and $0.066\;{\mu}g\;L^{-1}$ for microcystins (RR, YR, LR and LA), which indicates that the method has high sensitivity and accuracy. The most dominant genus of the cyanobacterial blooms was Microcystis, which accounted for 71% of the analysed samples. Microcystis also contained the largest amount of microcystins ($398.5\;{\mu}g\;gDW^{-1}$) among the analyzed cyanobacteria. The analysis of the five cyanotoxins showed that anatoxin-a ranged between $0{\sim}41.833\;{\mu}g\;gDW^{-1}$ and microcystins ranged between $6.311{\sim}2,148.786\;{\mu}g\;gDW^{-1}$. Among the microcystins, micocystin-RR took up 58.3%, the largest portion. Anatoxin-a was found to account for 77.8% of the samples. This study has its significance in that it allowed the establishment of toxin criteria appropriate for the Korean water systems. Further studies may be necessary to conduct for improving water treatment methods.

국내 소사육농가의 자가용 가축음용수 오염실태 평가조사 (Contamination status of groundwater used as livestock drinking in beef and dairy cattle farms, Korea)

  • 장양호;이수진;김효비;이정학;이만호;길혜경;최농훈
    • 대한수의학회지
    • /
    • 제51권1호
    • /
    • pp.47-53
    • /
    • 2011
  • In Korea, groundwater is main water source in livestock farms. Most dairy and cattle farms have constructed their own wells for human drinking and livestock farming. However, these private residential wells have not been controlled by government and also there was scant study about livestock drinking water quality. Therefore this study was to monitor of the livestock farms' groundwater quality in Korea. Water samples were collected at 123 dairy and cattle farms and were analysed forty six substances with quality standard for drinking water approved by the Minister of Environment. Seventy eight (63.4%) of 123 samples failed to drinking water stand a test. The most frequent contaminants were nitrate-nitrogen and microbial. 22.8% (n=28) of samples showed nitrate-N concentration of higher than 10 mg/L meant that can't be used drinking water for human and the Nitrate-N concentration analysed in the range of 0.2 to 61.2 mg/L. All of 78 failed to drinking samples had microbial problems, especially 5.7% (n=7) of samples indicated water could be contaminated by feces. Other contaminants detected were zinc and evaporation residue. Especially detected zinc concentration (32 mg/L) was about ten times higher than standard of zinc (3 mg/L). Regression analysis indicated that groundwater pH did not influence to nitrate-N concentration but the hardness and chloride could affect to nitrate-N concentration in the groundwater. Most livestock farms were adjacent to crop farmland in Korea. This could cause contamination of groundwater with nitrate-N and pesticide that could accumulate livestock product. Moreover Heavy metal such as zinc and copper could be released from a corrosive plated water pipe in livestock farm. Put together, Korea livestock system is indoor, not pasture-based, hence livestock could be exposed to potential contaminated water consistently. Therefore on the basis of these data, appropriate livestock drinking water quality standards should be prepared to keep livestock healthy and their product safe. Further, livestock drinking water quality should be monitored continuously in suitable livestock drinking water standards.

부산지역 3개 하천의 수질 특성 비교 (Water Quality Comparison in the Three Streams of Pusan Area)

  • 황선출;이봉헌
    • 한국환경과학회지
    • /
    • 제7권2호
    • /
    • pp.165-170
    • /
    • 1998
  • The purpose of thins study was to investigate the pollutions of water Qualities in 30 water samples from Nakdong River Western Nakdong River, and Suyoung Stream. COB, BOD. T-N and negative ion(F, Cl+, NO3-, SO42-) of water samples were analysed and the correlationships between water qualities were examined. The mean concentrations of COD(20.26ppm), BOD(25.36ppm), and T-N(18.05ppm) were the highest in the water sample of Suyoung Stream among the three streams and those of F-(0.25ppm), Cl+(2770ppm), and SO42-(37.66ppm) In Western Nakdong River, that of NO3-(10.8 ppm) in Nakdong River. The water quality of Suyoung Stream was the worst among the three streams in hsn area. The correlationships between water qualities were as follows , BOD and COD showed very high correlationship(correlation cofficient, r=0.97),50,2- and NO3'did high one(0.75), and NOa'and COD, BOD did relatively high ones(0.56 and 0.48, respectively).

  • PDF

Development of diagnostic method for human Astrovirus with rapid, specific and high sensitivity using loop-mediated isothermal amplification method

  • Lee, Jin-Young;Rho, Jae Young
    • 농업과학연구
    • /
    • 제47권1호
    • /
    • pp.173-182
    • /
    • 2020
  • Human Astrovirus (HuAstV), known as a waterborne virus, is a group IV positive-sense single-stranded RNA that belongs to Astroviridae. The first outbreak of HuAstV was reported in England in 1975. HuAstV can exist not only among clinical patients but also in various water environments, such as water for agriculture and vegetables. For diagnosis of HuAstV from water samples, a polymerase chain reaction (PCR) system has been developed. However, the PCR-based diagnostic method has problems in field application, such as reaction time, sensitivity and specificity. For this reason, in this study we developed the loop-mediated isothermal amplification assay (LAMP) system, aimed specifically at HuAstV. Three prepared LAMP primer sets were tested by specificity, non-specificity and sensitivity; one LAMP primer set was selected with optimum reaction temperature. The developed LAMP primer set reaction conditions were confirmed at 62℃, and detection sensitivity was 1 fg/μL. In addition, restriction enzyme HaeIII (GG/CC) was introduced to confirm that the LAMP reaction was positive. As a result, selected LAMP primer set was 100 - 1000 times more specific, rapid, and sensitive than conventional-nested PCR methods. For verification of the developed LAMP assay, twenty samples of cDNA from groundwater samples were tested. We expect that the developed LAMP assay will be used to diagnose HuAstV from various samples.

배추 재배에 이용되는 농업용수의 미생물 오염도 조사 및 이화학성분 분석 (Investigation of Microbiological and Physiochemical Quality for Irrigation Water used in Napa Cabbage Cultivation)

  • 윤보현;김민경;류진희;김원일;박병용;김현주;이승돈;김세리
    • 한국식품위생안전성학회지
    • /
    • 제32권5호
    • /
    • pp.396-403
    • /
    • 2017
  • 본 연구는 국내 배추 주산단지 5지역을 대상으로 배추재배에 활용되는 농업용수를 각 지역의 수확 시기에 채취하여 위생지표세균(총대장균군, 대장균, 장구균)과 이화학 성분을 분석함으로써 농업용수의 수질의 오염도를 조사하기 위하여 수행되었다. 그 결과 지하수 보다 지표수에서 위생지표세균이 높은 수준으로 검출되었다. 지표수의 경우 총대장균군 1.96-4.96 log MPN/100 mL, 지하수의 경우 0-3.98 log MPN/100 mL 수준이었다. 장구균의 경우 지표수에서 95% (72/75), 지하수에서 22% (8/36) 빈도로 검출되었으며, 대장균의 경우 지표수에서 100% (72/75), 지하수에서 22% (8/36) 빈도로 검출되었다. 위생지표세균과 이화학성분의 상관관계를 조사한 결과, 지표수의 경우 대장균군과 대장균은 총인과 상관성을 보였으며, 장구균은 부유물질과 생물학적산소요구량에 상관성을 보였다. 지하수의 경우 위생지표세균은 부유물질과 화학적산소요구량에 상관성을 보였다. 본 연구의 결과는 엽채류 재배에 사용되는 농업용수의 미생물 기준을 설정하기 위한 기초자료로 활용될 수 있을 것으로 판단된다.

캄보디아 쁘로얍 지역과 랭뜰 지역 거주민의 먹는물 현황 (Status of Drinking Water in Pproyap and Langthle, Cambodia)

  • 김연권;김성필;채선하
    • 환경영향평가
    • /
    • 제25권5호
    • /
    • pp.357-368
    • /
    • 2016
  • 캄보디아는 동남아시아 지역에서 대표적인 저개발 국가이다. 수자원의 관점에서 캄보디아는 풍부한 수량을 갖고 있지만, 농촌지역에서는 안전하지 않은 식수와 처리되지 않은 분뇨에 의하여 공중 보건의 문제가 이어지고 있다. 본 연구는 캄보디아 지역에서의 물 원조 프로그램을 위한 신전략수립과 준비를 위해 현지조사, 검토 및 농촌지역에서의 물 오염현황분석, 그리고 해당지역의 물 순환을 분석하였다. 조사 대상지역은 푸르사트주에 있는 쁘로얍과 랭뜰을 조사 대상지로 정하였다. 연구대상 농촌지역의 사람들은 식수전용 웅덩이, 빗물 항아리, 관리되지 않은 우물물 등 지표수에 의존하고 있었다. 분석은 분원성 미생물(TTC)과 일반항목으로 크게 두 가지로 하였으며, 대상지역에서 채수한 시료들을 분석/평가하였다. TTC는 수인성 배설물 오염의 세균 지표인데 26개의 시료중 단 한개만이 WHO가 규정한 TTC 허용한계인 불검출/100 mL의 기준을 충족시켰다.

상수도관망에서 분리한 잔류염소 내성균에 관한 연구 (Study on the Chlorine-Resistant Bacteria Isolated from Water Pipe Network)

  • 현재열;윤종호
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.334-341
    • /
    • 2011
  • The free residual chlorine of tap water samples, collected from 266 faucets on the water pipe network in Daegu City, was between 0.1 and 0.79 mg/L. On microorganic tests, general bacteria and the coliform goup were not detected and thus the tap water was turned out to be fit to drink. In particular, samples of which free residual chlorine was 0.1 mg/L and over were cultured in R2A agar media at $25^{\circ}C$ for 7 days, and as a result heterotrophic bacteria were detected in 65.9% of samples; (1). The closer tap water got to the faucet from the stilling basin, the lower residual chlorine concentration became but the more the bacterial count became. And, more bacteria were detected in the R2A agar medium than in the PCA medium. (2). In the case of separated strains, most colonies were reddish or yellowish. 16S rRNA sequence was identified as Methylobacterium sp. and Williamsia sp., and yellow strain was identified as Sphingomonas sp., Sphingobium sp., Novosphingobium sp., Blastomonas sp., Rhodococcus sp. and Microbacterium sp. White strain was identified as Staphylococcus sp. (3). Sterilized tap water in polyethylene bottles was inoculated with separated strain and was left as it was for 2 months. As a result, bio-film was observed in tap water inoculated with Methylobacterium sp. and Sphingomonas sp. It was found that heterotrophic bacteria increased when free residual chlorine was removed from tap water in the water pipe network. Thus, there is a need to determine a base value for heterotrophic bacteria in order to check the cleanliness of tap water in the water pipe network.

Column Preconcentration and Determination of Cobalt(II)Using Silica Gel Loaded with 1-Nitroso-2-naphthol

  • Shin, Eun-Mi;Choi, Hee-Seon
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권7호
    • /
    • pp.1516-1520
    • /
    • 2009
  • A sensitive technique for the determination of trace Co(II) in various samples after column preconcentration by adsorbing onto silica gel loaded with 1-nitroso-2-naphthol was developed. Several experimental conditions, such as pH of sample solution, the amount of silica gel loaded with 1-nitroso-2-naphthol, the flow rate for adsorption and so forth, were optimized. The interfering effects of diverse concomitant ions were investigated. Fe(III) interfered with more than any other ions, but the interference by Fe(III) was completely eliminated by adjusting the amount of silica gel loaded with 1-nitroso-2-naphthol to 0.30 g. The dynamic range, the correlation coefficient ($R^2$), and the detection limit obtained by the proposed technique were 3.0-140.0 ng m$L^{-1}$, 0.9942, and 1.81 ng m$L^{-1}$, respectively. For validating the technique, the aqueous samples (tap water, reservoir water, stream water, and wastewater) and the plastic samples were used as real samples. Recovery yields of 93.0-107.0% were obtained. These measured data were not different from ICP-MS data at the 95% confidence level by F test. Based on the results of the experiment, it has been found that the proposed technique can be applied to the determination of Co(II) in various real samples.

Alloy 600의 결정립계 산화에 대한 표면 변형의 영향 (Effects of Surface Deformation on Intergranular Oxidation of Alloy 600)

  • 하동욱;임연수;김동진
    • Corrosion Science and Technology
    • /
    • 제19권3호
    • /
    • pp.138-145
    • /
    • 2020
  • Immersion tests of Alloy 600 were conducted in simulated primary water environments of a pressurized water reactor at 325 ℃ for 10, 100, and 1000 h to obtain insight into effects of surface deformation on internal and intergranular (IG) oxidation behavior through precise characterization using various microscopic equipment. Oxidized samples after immersion tests were covered with polyhedral and filamentous oxides. It was found that oxides were abundant in mechanically ground (MG) samples the most. The number density of surface oxides increased with time irrespective of the method of surface finish. IG oxidation occurred in mechanically polished (MP) and chemically polished (CP) samples with thin internal oxidation layers. However, IG oxidation was suppressed with relatively thick internal oxidation layers in MG samples compared to MP and CP samples, suggesting that MG treatment could increase resistance to primary water stress corrosion cracking (PWSCC) from the standpoint of IG oxidation. As a result, appropriate surface treatment for Alloy 600 could prevent oxygen diffusion into grain boundaries, inhibit IG oxidation, and finally induce its high PWSCC resistance.