• 제목/요약/키워드: water resource

검색결과 1,865건 처리시간 0.035초

물 자원 생산을 위한 Coal Seam Gas Water Management Study의 평가 및 분석 -1. 용수 생산 (Assessment and Analysis of Coal Seam Gas Water Management Study for Water Resource Production -1. Water Production)

  • 신춘환
    • 한국환경과학회지
    • /
    • 제23권8호
    • /
    • pp.1395-1407
    • /
    • 2014
  • Coal seam gas (CSG) production involves extracting methane from coal seams with ground water which is so called a primary by-product of this process, and is often rich in salts and other constituents. The predicted large volume and variable quality of this water make water management a topic associated with CSG production. In the past, the amount of this water used to be pumped into the vacant aquifer, or into the river during the life of individual production wells. Australian government make a strategies for management and beneficial use of the water. From this point of view, a detailed assessment has not been undertaken, it is necessary for water resource production to analysis the "Coal Seam Gas Water (CSG Water) Management Policy Study" published in Queensland, Australia.

파랑특성을 고려한 조력발전소 여자시스템 적용에 관한 연구 (Tidal Power Station Excitation System for a Considering Wave Characteristic)

  • 김현한;김광호;정종찬;박성호;옥연호;최형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.251-252
    • /
    • 2008
  • Si-Hwa tidal power station is using difference of the ebb and flow. The active power is dependent on up and down sea water level but if it is drastically changed because of a typhoon or waves the generator terminal voltage and active power is changed that is a chief cause of power station unstability. Therefore this paper arrange a present state of power or frequency fluctuation and generator terminal phase difference in case of occurrence a drastic change of sea water level.

  • PDF

학교시설 친환경건축인증 사례를 통한 수자원 및 환경오염 평가항목 연구 (A Study on the Water Resource and Environmental Pollution Level of Education Facilities in Green Building Certification Criteria)

  • 곽문근;최창호
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.678-687
    • /
    • 2009
  • The purpose of this study is to develop the assessment category, items, a detail standard for environmentally friendly evaluation on the school. and to analyze the plan to improve the level of certification criteria on the School's water resource and environmental pollution. The results of this study brings on promoted environmentally friendly appreciation, resource con servation, reduction of contaminant, accordance in and around building, etc. For this purpose, analysis of domestic and foreign environmental friendly architectural citation screening system-BREEAM (1991), LEED 2.0(2001) etc.-was preceded, and through interview, survey and forum with professional group, developed evaluation item was verified and reappraised. Developed evaluation item were composed of 40 schools about water resource and environmental pollution.

해외 상수원 보호구역 정책에 관한 고찰 (A review of water protection zone policies in other countries)

  • 류문현
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.83-88
    • /
    • 2020
  • 상수원수질보호는 국민의 건강과 생존에 관한 중요한 문제이기 때문에 어느 나라 할 것 없이 상수원 수질오염을 방지하기 위해 여러 가지 정책적 노력을 기울이고 있다. 본 논고에서는 미국, 유럽 등 해외의 상수원보호구역제도와 관련된 정책을 고찰함으로써 우리나라의 상수원보호구역 제도의 정책대안을 모색하고자 한다.

THE CLASSIFICATION SYSTEM OF RIVER HEALTH FOR THE ENVIRONMENTAL WATER QUALITY MANAGEMENT

  • Carolyn G. Palmer;Jang, Suk-Hwan
    • Water Engineering Research
    • /
    • 제3권4호
    • /
    • pp.259-267
    • /
    • 2002
  • South Africa has developed a policy and law that calls and provides for the equitable and sustainable use of water resources. Sustainable resource use is dependent on effective resource protection. Rivers are the most important freshwater resources in the country, and there is a focus on developing and applying methods to quantify what rivers need in terms of flow and water quality. These quantified and descriptive objectives are then related to specified levels of ecological health in a classification system. This paper provides an overview of an integrated and systematic methodology, where, fer each river, and each river reach, the natural condition and the present ecological condition are described, and a level/class of ecosystem health is selected. The class will define long term management goals. This procedure requires each ecosystem component to be quantified, starting with the abiotic template. A modified flow regime is modelled for each ecosystem health class, and the resultant fluvial geomorphology and hydraulic habitats are described. Then the water chemistry is described, and the water quality changes that are likely to occur as a consequence of altered flows are predicted. Finally, the responses to the stress imposed on the biota (fish, invertebrates and vegetation) by modified flow and water quality are predicted. All of the predicted responses are translated into descriptive and/or quantitative management objectives. The paper concludes with the recognition of active method development, and the enormous challenge of applying the methods, implementing the law, and achieving river protection and sustainable resource-use.

  • PDF

수력발전소 EMS RTU 구성방식 개선 적용 (An improvement and application for EMS RTU configuration method in K-water hydropower plants)

  • 김용환;이경배;가필순;이성우;김종겸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.770-771
    • /
    • 2011
  • 발전사업자는 한국전력거래소(KPX)의 급전지령을 원활히 수행하기 위해 EMS(Energy Management System) RTU를 설치하고 있다. 한국수자원공사는 수력발전소에 전기판넬 형식의 EMS RTU 대신 컴퓨터 기반의 가상(Virtual) EMS RTU를 설치하여 기존의 RTU방식에 비하여 설비 면적을 대폭 줄였으며, 설비 변동에 따른 감시제어 데이터의 수정시 하드웨어적인 작업을 소프트웨어적으로 간단하게 처리할 수 있다. 그래서 가상 EMS RTU는 발전통합운영시스템(GIOS)을 실시간으로 운영, 감시하여 장애를 신속히 복구함으로써 중앙급전소 발전기 원격운전 응답 특성을 향상시켜 전력계통의 안정적인 운영에 크게 기여하고 있다.

  • PDF

수도관로를 이용하는 소수력의 최적 설계 방안 (The Optiunm Design Plan for Small Hydropower Plant Using of Waterpipe)

  • 이형묵;김기원;변일환;홍정조;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1728-1730
    • /
    • 2005
  • Many domestic organizations are pushing ahead with small hydropower business to develop a renewable energy. In addition each organization gradually spreads small hydropower business with searching the best site for it. And KOWACO(Korea Waters Resources Corporation) answers a purpose of the government policy to spread the wide use of a renewable energy. This study explains the researching programs for the best development sites for small hydropower generation with using water pipes managed and controled by KOWACO.

  • PDF

수요관리에 의한 물수급변화 분석 (A Study of Water Budget Analysis According to The Water Demand Management)

  • 서재승;이동률;최시중;강성규
    • 대한환경공학회지
    • /
    • 제33권11호
    • /
    • pp.797-803
    • /
    • 2011
  • 본 연구에서는 물 사용관련 주요 지표인 1인1일 급수량을 이용하여 수요관리 추진 결과 분석 및 절감량을 산정하고, 수요관리를 통하여 발생하는 절감량을 물 수급전망에 연계할 수 있는 시스템을 개발하였다. 1인1일 급수량 분석결과 상수도 여건이 열악한 지자체는 상수도 보급 개선이 선행되어야 하며, 장래용수수요량 추정시에도 이를 고려하여야 할 것으로 판단된다. 금강권역을 대상으로 수요관리 절감량을 산정하고 K-WEAP (Korea-Water Evaluation And Planning System)을 이용하여 물수지분석을 수행한 결과 하천유량 변화 및 지하수와 저수지저수량 증가를 확인하였으며, 이는 다른 용도로 활용 가능하다고 판단된다.

Seawater-driven forward osmosis for direct treatment of municipal wastewater

  • Sun, Yan;Bai, Yang;Tian, Jiayu;Gao, Shanshan;Zhao, Zhiwei;Cui, Fuyi
    • Membrane and Water Treatment
    • /
    • 제8권5호
    • /
    • pp.449-462
    • /
    • 2017
  • Direct treatment of municipal wastewater by forward osmosis (FO) process was evaluated in terms of water flux decline, reverse salt diffusion, pollutants rejection and concentration efficiency by using synthetic seawater as the draw solution. It was found that when operating in PRO mode (active layer facing the draw solution), although the FO membrane exhibited higher osmotic water flux, more severe flux decline and reverse salt diffusion was also observed due to the more severe fouling of pollutants in the membrane support layer and accompanied fouling enhanced concentration polarization. In addition, although the water flux decline was shown to be lower for the FO mode (active layer facing the feed solution), irreversible membrane fouling was identified in both PRO and FO modes as the water flux cannot be restored to the initial value by physical flushing, highlighting the necessity of chemical cleaning in long-term operation. During the 7 cycles of filtration conducted in the experiments, the FO membrane exhibited considerably high rejection for TOC, COD, TP and $NH_4{^+}-N$ present in the wastewater. By optimizing the volume ratio of seawater draw solution/wastewater feed solution, a concentration factor of 3.1 and 3.7 was obtained for the FO and PRO modes, respectively. The results demonstrated the validity of the FO process for direct treatment of municipal wastewater by using seawater as the draw solution, while facilitating the subsequent utilization of concentrated wastewater for bioenergy production, which may have special implications for the coastline areas.