• 제목/요약/키워드: water repellent

검색결과 226건 처리시간 0.028초

발수제 종류에 따른 코팅된 커피찌꺼기를 치환한 모르타르의 압축강도 및 흡수율 (Compressive Strength and Absorption Ratio of Mortar Replaced with Coated Spent Coffee Grounds by Type of Water Repellent)

  • 최병철;김규용;편수정;지성준;이예찬;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.63-64
    • /
    • 2023
  • In order to reduce the high absorption ratio of spent coffee grounds, this study examined the compressive strength and absorption ratio of mortar replacing coated spent coffee grounds according to the type of water repellent. In order to examine this, as the water repellent used, a silane-based water repellent (fluorine-based water repellent) and an acrylic-based water repellent, which are film-type water repellents, and a silane/siloxane-based water repellent, which are penetration-type water repellents, were used. The spent coffee grounds were coated with each of three water repellents, and mortar was prepared by mixing cement and fine aggregate. As a result of the experiment, the compressive strength and absorption ratio of the mortar replaced with coated spent coffee grounds coated with the film-type water repellent were superior to the penetration-type water repellent. Therefore, in order to reduce the high absorption ratio of spent coffee grounds, a suitable water repellent is a film-type water repellent. Among them, it is judged that the acrylic type has excellent water repellency and is suitable.

  • PDF

무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구 (An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type)

  • 김영삼;양승도;유재강;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.31-36
    • /
    • 2002
  • Recently, more interests in surface treatment of structure with water repellent agent are steadily increased, But, investigation of its properties such as protection, durability, morphology of micro structure is not sufficient. Therefore, This paper is aimed for the investigation of water repellent property and change of morphology of micro pores in mortar that is treated by water repellent agent(Inorganic polymer based material). Water repellent property, water absorption coefficient, air permeability, porosity and the observation of micro structure was investigated in different water repellent agent type. The test results indicated that water repellent treated mortar showed low absorption coefficient and air permeability(breathing effect). This is why inorganic polymer is coated at the wall of capillary and micro pores, also, the volume of micro pore is reduced without the change of morphology in micro structure.

  • PDF

무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구 (An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type)

  • 이일형;엄덕준;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술.기술논문발표회
    • /
    • pp.33-37
    • /
    • 2004
  • Recently, Growing tendency for structure surface to use water repellent agent has increased steadily. But investigation of it's protection and durability property is not sufficient. Therefore, this paper shows the investigation about repellent property and micro structure's change in surface layer of mortar that is applied by water repellent agent. Water repellent property, absorption coefficient, air permeability, porosity and observation of micro construct was investigated according to water repellent agent type. The test results indicated that mortar applied water repellent agent appears tiny absorption coefficient, but air permeability is maintained. The reason is because silane solution is coating at capillary surface of a wall and minute pore structure is changeless.

  • PDF

발수제 혼입 방법에 따른 시멘트 모르타르의 물리적 특성 및 발수 성능에 관한 실험적 연구 (An Experimental Study on Physical Properties and Water Repellent Performance of Cement Mortar According to Mixing Method of Water Repellent)

  • 김완수;양현민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.99-100
    • /
    • 2019
  • Water repellent and waterproofing agents fail to act work properly if cracks or detachment occurs outside. The method of making mortar was tested by classifying it into two methods: direct water-repellent put in concrete and water-repellent spray to sand method. It was found that the compressive strength was decreased as the amount of water repellent was increased. As a result of measuring the contact angle, all of the specimens were hydrophobic. The spray method showed greater water repellent effect than the direct mixing method.

  • PDF

발수제 혼입에 따른 시멘트 모르타르의 표면 얼음 제거성능에 관한 연구 (A Study on the Deicing Performance of Cement Mortar through the Addition of Water-repellent)

  • 강석표;홍성욱;인병은;김상진
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.597-606
    • /
    • 2022
  • 본 논문은 발수제 혼입에 따른 시멘트 모르타르 표면의 얼음 제거성능에 다양한 요인 중 발수제 첨가 및 종류에 대한 영향을 검토하였다. 그 결과 발수제 첨가 시멘트 모르타르의 압축강도는 무첨가 시멘트 모르타르와 비교하여 감소하였고, 올리고머계 발수제 첨가 모르타르의 압축강도는 모노머계 발수제와 비교하여 높게 나타났다. 발수제 첨가 모르타르의 접촉각은 무첨가 모르타르와 비교하여 증가하였고 모노머계 발수제보다는 올리고머 발수제가 상대적으로 증가하였다. 발수제 혼입에 따른 시멘트 모르타르의 얼음형성시간 측정 결과 발수제를 첨가하였을 때 25분까지 지연시키는 것으로 나타났다. 얼음 제거하중 측정결과 발수제를 첨가하지 않은 모르타르는 342N을 발현하였고 발수제를 첨가한 모르타르는 31N을 발현하여 발수제를 모르타르에 첨가하는 경우 얼음제거성능이 감소하였다.

양모직물의 내구성 발수 및 발유가공(I) (Durable Water and Oil Repellent Finish of Wool Fabric(I))

  • 나도춘;정순량;박병기;정경락
    • 한국염색가공학회지
    • /
    • 제10권1호
    • /
    • pp.33-37
    • /
    • 1998
  • It is rather important in the water and oil repellent finishing for wool fabric what kind of water-repellent agents will be used. In many cases, Fluorocarbon-based water-repellent agents(eg.Oleophobol-S), the surface tensions of which very low, were recom-mended on account of good water and oil repellencies. In repellent finishing, fabrics were padded in a bath which contained aqueous solution of water-repellent agents, and wetting agents, followed by drying and curing. The most suitable treating condition for excellent repellency was as follows Fabrics were padded at liquor pick-up ratio of 50%, with aqueous solution which contained $30g/\ell$ of water-repellent agents, and $40g/\ell$ of wetting agents. And the padded fabrics were dried at $110^\circ{C}$ for 1 minute, and cured at $160^\circ{C}$ for 2 minutes. For the fabrics, water and oil repellencies and durability to repeated dry-cleanings are observed.

  • PDF

자동차 내장용 직물의 난연 및 발수가공 (Flame-Retardant and Water-Repellent Finishing of Automobile Indoor Fabrics)

  • 박병기;이방원;김환철;김학용
    • 한국염색가공학회지
    • /
    • 제11권5호
    • /
    • pp.7-12
    • /
    • 1999
  • The objective of this study is to apply water repellent and flame retardant finishes simultaneously to the fabric used for automobile. Both two step and one step methods were tried to apply the finishing agent to the fabric. In the two step method, water repellent agent was treated first, and flame retardant agent was applied next. The reverse finishing process was also attempted. In the one step method, flame retardant agent and water repellent agent treated to the fabric in one bath. The results of two step method revealed that the finishing effect was better when the water repellent agent was treated first than when flame retardant agent was treated first. In one step method, fluoro water repellent agent was superior to silicon water repellent agent.

  • PDF

유/무기 복합 발수제를 혼입한 모르타르의 재료특성 평가 (Material Properties Evaluation of Cement Mortar Mixed with Organic/Inorganic Combined Water-repellent)

  • 김완수;윤창복;조인성;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권6호
    • /
    • pp.50-58
    • /
    • 2020
  • 발수제를 콘크리트 표면에 함침시키는 방법은 콘크리트의 균열이 발생할 경우, 기대하는 내구성을 확보할 수가 없다. 최근, 다양한 방수 및 발수 재료들을 콘크리트나 모르타르 내부에 혼입하여 균열 내부에서도 발수성을 확보하였으나 압축강도가 크게 저하되었다. 압축강도 저하를 극복하기 위해 아직까지 유기물과 무기물의 장점들을 동시에 이용한 연구가 없기 때문에, 본 연구에서는 유기물과 무기물을 적절히 혼합한 유무기 복합 발수제를 모르타르에 혼입하여 물리적 특성 및 발수성능을 평가하였다. 유무기 복합 발수제 혼입 시 Liquid 시험체에 비해 플로우 약 10%, 공기량이 약 50% 감소하였으며, P6L1 시험체의 경우, 기존 발수제인 Powder와 같은 39.5MPa로 무혼입 모르타르 대비 약 3.5%의 압축강도 저하를 확인하였다. 발수성능도 유무기 복합 발수제 혼입 시험체가 기존의 발수제 혼입 시험체인 Powder보다 높은 발수성을 확인하였으며, 염화물 침투 저항성 평가결과, 유무기 복합 발수제 혼입 시험체가 무혼입 모르타르 대비 약 45% 통과 전하량이 감소되는 것을 확인하였다. 이상의 실험을 종합하면, Powder 발수제와 Liquid 발수제를 5:1의 비율로 혼입한 P5L1 유무기 복합 발수제가 압축강도 저하 방지 및 발수성능 확보를 위하여 가장 합리적이라고 판단된다.

Status and Prospect of Test Methods of Quality Silicone Water Repellent for Protecting Reinforced Concrete

  • Sun, H.Y.;Yuan, Z.Y.;Yang, Z.;Shan, G.L.;Shen, M.X.
    • Corrosion Science and Technology
    • /
    • 제16권3호
    • /
    • pp.141-150
    • /
    • 2017
  • Impregnating with quality silicone water repellent on the concrete surface is an effective method of protecting concrete. Quality silicone water repellent has been widely used in the engineering profession because of its desirable properties such as hydrophobicity, keeping concrete breathable and preserving the original appearance of the concrete. The companies in China that produce silicone water repellent are listed. Test methods in the specifications or standards about silicone water repellent in China are summed. The test methods relative to durability of concrete impregnated with silicone water repellent (such as resistant to chloride ion penetration, resistant to alkali, resistance to freezing and thawing and weatherability etc.) and the constructive quality (such as water absorption rate, impregnating depth and the dry velocity coefficient etc.) are compared and analyzed. The results indicate that there are differences among test methods relative to different specifications with the same index and therefore, confusion has ensued when selecting test methods. All test methods with the exception of the method of water absorption rate by using a Karsten flask are not non-destructive methods or conducted in a laboratory. Finally, further research on silicone water repellent during application is proposed.

양모직물의 내구성 발수 및 발유가공(II) (Durable Water and Oil Repellent Finish of Wool Fabric(II))

  • 나도춘;정순량;박병기;정경락
    • 한국염색가공학회지
    • /
    • 제10권4호
    • /
    • pp.1-6
    • /
    • 1998
  • It is important in the durable water and oil repellent finishing for wool fabric what kinds of water-repellent agents will be used. Water repellent agents and its concentration were aleady chosen in the previous paper, one of the crosslinking agents which has less damages(harsh handle or yellowing) to the treated fabrics was a low molecular weight urethane-based resins(eg. Elastron BN-11). In repellent finishing, fabrics were padded in a bath which contained aqueous solution of water-repellent agents, and crosslinking agents, and wetting agents, followed by drying and curing. The most suitable treating condition for excellent repellency and durability to dry-cleaning was as follows : Fabrics are padded at liquor pick-up ratio of 50%, with aqueous solution which contained $30g/\ell$ of water-repellent agents, and $1g/\ell$ of crosslinking agents, and 40g/s of wetting agents. And the padded fabrics were dried at $110^\circ{C}$ for 1 minute, and cured at $160^\circ{C}$ for 1 minute. For the fabrics, water and oil repellencies and durability to repeated dry-cleanings were observed. For enhancing the durability to dry-cleaning, the role of crosslinking agents was important for they bonds water-repellent agents and fibers to 3-dimensional net structure. Therefore, the most suitable drying and curing conditions should be selected according to the kinds of crosslinking agents.

  • PDF