• Title/Summary/Keyword: water removal

Search Result 4,225, Processing Time 0.036 seconds

TDS Removal using Bio-sorption with AGS and High Concentration Nitrogen Removal (AGS의 생물흡착을 이용한 TDS 제거 및 고농도 질소제거에 관한 연구)

  • Eom, Han Ki;Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.3
    • /
    • pp.303-309
    • /
    • 2016
  • This study aimed to assay the biological removal of TDS (total dissolved solids) from RO (reverse osmosis) rejected water. Following bio-sorption of TDS with AGS (aerobic granular sludge), the effects of TDS on biological nitrogen removal were examined. The bio-sorption of TDS after AGS treatment was confirmed by checking for TDS removal efficiency and surface analysis of microorganisms with SEM and EDS. Then, the effects of TDS on biological nitrogen removal and the denitrification efficiency were evaluated using the MBR reactor. According to the results, the bio-sorption of TDS with AGS was 0.1 mg TDS/mg AGS, and we confirmed that the microorganism surfaces had adsorbed the TDS. Biological nitrogen removal efficiency was measured at inhibiting denitrification at 4,000 mg/L of TDS-injected material. Based on this study, it is necessary to pretreat TDS-containing RO rejected water and to maintain TDS concentration lower than a specific value (≤4,000 mg/L), when considering biological nitrogen removal.

Operation evaluation of DAF pilot plant for water treatment process in Hoedong Reservoir (회동수원지의 정수처리 공정을 위한 DAF pilot plant 운영 성능평가)

  • Maeng, Minsoo;Shahi, Nirmal Kumar;Kim, Donghyeun;Shin, Gwyam;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.6
    • /
    • pp.463-471
    • /
    • 2020
  • A 1,000 ㎥/d DAF(dissolved air flotation) pilot plant was installed to evaluate the performance of the floating process using the Nakdong River. Efficiency of various DAF operations under different conditions, such as hydraulic loading rate, coagulant concentration was evaluated in the current research. The operation conditions were evaluated, based on the removal or turbidity, TOC(total organic carbon), THMFP(trihalomethane formation potential), Mn(manganese), and Al(aluminum). Also, particle size analysis of treated water by DAF was performed to examine the characteristics of particles existing in the treated water. The turbidity removal was higher than 90%, and it could be operated at 0.5 NTU or less, which is suitable for the drinking water quality standard. Turbidity, TOC, and THMFP resulted in stable water quality when replacing the coagulant from alum to PAC(poly aluminum chloride). A 100% removal of Chl-a was recorded during the summer period of the DAF operations. Mn removal was not as effective as where the removal did not satisfy the water quality standards for the majority of the operation period. Hydraulic loading of 10 m/h, and coagulant concentrations of 40 mg/L was determined to be the optimal operating conditions for turbidity and TOC removal. When the coagulant concentration increases, the Al concentration of the DAF treated water also increases, so coagulant injection control is required according to the raw water quality. Particle size distribution results indicated that particles larger than 25 ㎛ showed higher removal rates than smaller particles. The total particel count in the treated water was 2,214.7 counts/ml under the operation conditions of 10 m/h of hydraulic loading rate and coagulant concentrations of 60 mg/L.

Removal Characteristics of Iron, Manganese and Organics in Ground Water Using Ozonation (오존을 이용한 지하수의 철.망간 및 유기물 제거특성)

  • 선창욱;우달식;남상호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.43-49
    • /
    • 1997
  • Iron and manganese problems in ground water affect far more water systems than almost any other water quality concern. The purpose of this study is to find the optimum condition of ozonation for the removal of dissolved iron, manganese and other organics in the polluted ground water. We proposed 4mg/l, 8mg/l as optimum ozone dose for the removal of $Fe^{2+},{\;}Mn^{2+}$, respectively. The removal efficiencies of $COD_{Mn}$ and $COD_{Cr}$ in ozone dose of 2mg/l - 6mg/l were about 40-50%. The removal efficiency of $NH_{3}-N$ was about 30-40% at pH8.5. In conclusion, it needs further systematic study and research concerned to treatability of $Fe^{2+},{\;}Mn^{2+}$ and biodegradability of organic compounds using Ozonation followed by biological filtration process in ground water treatment train.

  • PDF

Study on the Effectiveness of Continuous Water Removal in Oil Immersed Transformers (유침절연 변압기에서 연속적 수분제거 유효성에 관한 연구)

  • Sun, Jong-Ho;Hwang, Don-Ha;Kim, Jin-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.20-25
    • /
    • 2016
  • This paper describes the effectiveness of continuous water removal in oil immersed transformers. Insulation oil in which insulation papers were immersed were prepared for tests and water concentrations in oil with heating time were measured at five oil temperatures. Also, the tests that water dissolved in $100^{\circ}C$ oil was removed at once and continuously at $50^{\circ}C$ and $100^{\circ}C$ were performed for consideration of effective method for water removal. Test results indicated that the oils for water measurement have to be extracted at similar temperatures and water in oil has to be continuously removed at higher temperatures for more effective water management of transformers.

Drinking Water Treatment of Surface Water Using Microfiltration-Nanofiltration Processes (정밀여과 및 나노여과 공정을 이용한 지표수의 상수처리)

  • Lee, Sung-Woo;Kim, Chung-Han;Kwak, Dong-Heui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.224-230
    • /
    • 2000
  • Membrane processes are capable of removing much materials from water. The removal or rejection characteristics of a membrane is usually depend upon the nominal pore size or MWCO(molecular weight cut off). A membrane with a smaller nominal pore size or MWCO should be capable of removing smaller contaminants from water. A series of experiments was performed to investigate the separation characteristics of membrane processes which consisted of microfiltration(MF) and nanofiltration(NF). To evaluate removal efficiencies of some pollutants such as the consumption of $KMnO_4$, THMFP, NH3-N, Fe, Mn, and pesticides, source water sampled from the Kum river was treated by the those membrane processes. Also, the results of experiments were compared with those of conventional water treatment processes. By two types of the membrane process, total removal efficiency of $KMnO_4$ consumed, THMEP, and $NH_3-N$ were 91.0%, 84.3%, and 85.5%, respectively and those processes were efficient in pesticides removal as well. Most of the effluents satisfied the Korean standard of drinking water quality continuously in the experimental periods. However, NF was needed for producing the safe drinking water in case of treating the raw water contaminated with Mn since removal efficiency of MF was not high enough. On the basis of the experimental results, it was suggested that NF could be applied to remove not only $NH_3-N$ but THMFP even without pre-chlorination.

  • PDF

Removal of NOM in a Coagulation Process Enhanced by Modified Clay (개질 Clay를 첨가한 응집공정에서의 자연유기물 제거)

  • Park, Ji-Hye;Lee, Sang-Yoon;Park, Hung-Suck
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.37-46
    • /
    • 2007
  • A feasibility test was conducted to evaluate the addition of turbidity substance in a coagulation process to remove natural organic matters (NOM), the precursor of disinfection by-products (DBPs). The experimental water sources were synthetic water containing 5 mg/L of humic acid and 50 mg/L of NaHCO3 and drinking water resource of Ulsan city (S Dam water, D Dam water and Nak-Dong raw water). The examined turbidity substances were kaolin, acid clay, and modified clay (0.38 meq $NH_4{^+}-N/g$ clay). In Jar tests at different concentrations of the turbidity substances (5, 10, 15, 20, 30 mg/L) using the synthetic water, the turbidity substances improved the removal of turbidity, UV-254 absorbance and dissolved organic carbon (DOC) by 23.8-38.1%, 17.0-24.5% and 2.5-44.5%, respectively. The modified clay showed higher removal efficiencies than other substances. In Jar tests using the drinking water, 10 and 20 mg/L of modified clay enhanced the removal efficiencies of turbidity, UV-254 absorbance, DOC, trihalomethane formation potential (THMFP), and haloacetic acid formation potential (HAAFP) by 3.0~4.3%, 19.1~29.0%, 12~34.9%, 4.9~36.7%, and 1.6~30.2%, respectively.

Removal characteristics of NOM in advanced water treatment using ceramic MF membrane (세라믹막(MF) 고도정수처리에서 NOM 제거 특성)

  • You, Sang-Jun;Park, Sung-Han;Lim, Jae-Lim;Suh, Jeong-Min;Jang, Seong-Ho;Hong, Sung-Chul;Yi, Pyong-In
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.367-376
    • /
    • 2014
  • This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and $UV_{254}$ in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.

Temporal and Spacial Distributions of Water Quality and Evaluation of Pollutant Removal Efficiency in the Sihwa Constructed Wetland (시화호 인공습지에서 시공간적 수질분포 및 오염물질 제거효율 평가)

  • Choi, Don-Hyeok;Choi, Kwang-Soon;Kim, Dong-Sup;Kim, Sea-Won;Choi, Dong-Ho;Hwang, In-Seo;Lee, Yun-Kyoung;Kang, Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.1013-1020
    • /
    • 2008
  • To evaluate the pollutant removal efficiency and clarify the cause of low removal efficiency of the wetland, temporal and spacial distributions of water quality were investigated at 16 sites in the Sihwa constructed wetland. The removal efficiency showed a tendency to decrease since the construction of the wetland, except for TN. In addition, the efficiency was largely varied with season, especially BOD and TP. No removal efficiency of BOD was observed in April and July when algal bloom was occurred in lower part open water of the wetland. On the other hand, TP showed no removal efficiency from April to August showing -291% of removal efficiency in August. From the horizontal distribution in closed water regions, SS concentration for the central area was significantly higher than for left and right areas(p = 0.013, center > left > right areas). From the results of this study, we infer that anaerobic condition due to the excessive accumulation of organic matters and lack of uniformity of water flow distribution are major factors of the low removal efficiency of the wetland.

Removal of low concentration organic matter by reverse osmosis membranes in ultrapure water production process (초순수 제조 공정에서 역삼투 막의 저농도 유기물 제거)

  • Lee, Hongju;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.4
    • /
    • pp.391-396
    • /
    • 2014
  • Ultrapure water (UPW) is water containing nothing but water molecule ($H_2O$). The use of UPW is increasing in many industries such as the thermal and nuclear power plants, petrochemical plants, and semiconductor manufacturers. In order to produce UPW, several unit processes such as ion exchange, reverse osmosis (RO), ultraviolet (UV) oxidation should be efficiently arranged. In particular, RO process should remove not only ions but also low molecular weight (LMW) organic matters in UPW production system. But, the LMW organic matter removal data of RO membranes provided by manufacturers does not seem to be reasonable because they tested the removal in high concentration conditions like 1,000 ppm of isopropyl alcohol (IPA, MW=60.1). In this study, bench-scale experiments were carried out using 4-inches RO modules. IPA was used as a model LMW organic matter with low concentration conditions less than 1 ppm as total organic carbon (TOC). As a result, the IPA removal data by manufacturers turned out to be trustable because the effect of feed concentration on the IPA removal was negligble while the IPA removal efficiency became higher at higher permeate flux.

Optimum Condition for Fluoride Removal Prior to the Application of Struvite Crystallization in Treating Semiconductor Wastewater (Struvite 결정화를 이용한 반도체 폐수처리 시 불소제거를 위한 최적 조건)

  • An, Myeong Ki;Woo, Gwi Nam;Kim, Jin Hyung;Kang, Min Koo;Ryu, Hong Duck;Lee, Sang-Ill
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.916-921
    • /
    • 2009
  • This study was aimed to both enhance the fluoride removal and to reduce the phosphorus removal in treating semiconductor wastewater using $Ca(OH)_2$ at low pH so as to facilitate struvite crystallization reaction. The struvite crystallization could be introduced after fluoride removal by retaining the phosphorus source. As the results, the method applied in this study achieved high fluoride removal efficiency (about 91%) with retardation of phosphorus removal at pH 4, compared to conventional methods where the removal of fluoride and phosphorus were done at pH 11. Therefore, the fluoride removal at low pH would contribute to the enhancement of nitrogen and phosphorus removals in a consecutive struvite crystallization reactor. Treatment of semiconductor wastewater at low pH using $Ca(OH)_2$ also had lower (about 20%) water content of precipitated sludge compared to conventional method. As the molar ratio of Ca to F increased the removal efficiencies of fluoride and phosphorus increased. Although the amount of seed dosage didn't affect the removal of fluoride and phosphorus, its increase reduced the water content of precipitated matter. Finally, considering consecutive struvite reaction, the optimum condition for the removal of fluoride and phosphorus was as follow: pH: 4, the molar ratio of Ca:F: 1:1.