• 제목/요약/키워드: water purifier

검색결과 89건 처리시간 0.021초

어린이집 급식실 정수기의 미생물학적 오염 평가 (Prevalence of Microbiological Contamination on Water Purifiers at Lunchroom in Child Care Center)

  • 윤미혜;김중범;오혁수
    • 한국식품조리과학회지
    • /
    • 제28권5호
    • /
    • pp.599-604
    • /
    • 2012
  • In this study, the prevalence of microbiological hazard on water purifiers at lunchroom in child care center was investigated. A total of 49 water purifiers and their purified cold water were sampled to test about the total aerobic bacteria, coliform bacteria, Bacillus cereus, Staphylococcus aureus, and Salmonella spp. Total aerobic bacteria was detected over 2.0 log CFU/mL in 6 out of 49 purified cold water (12.2%), ranged from 2.0 to 2.4 log CFU/mL, and the average number of total aerobic bacteria was showed to be 3.3 log CFU/drain spout. The drain spout turned out to be a major contaminant in water purifier and needs to be improved. Coliform bacteria were also detected in 7 out of 49 cold faucets (14.3%) and 7 out of 49 drain spouts (14.3%), but not detected in purified cold water. All samples were not contaminated with the pathogens tested in this study, except for B. cereus, which was contaminated on 2 out of 49 cold faucets (4.1%) and 4 out of 49 drain spouts (8.2%). All of B. cereus isolates produced enterotoxin, such as heamolysin BL enterotoxin (HBL) or non-heamolytic enterotoxin (NHE). The HBL was detected in 5 out of 6 B. cereus isolates (83.3%), including B. cereus PCF-11 and B. cereus PDS-30 isolate only produced NHE (16.7%). These results showed that the sanitary conditions of cold faucets and drain spouts should be improved promptly.

IMO 규정 대응 선박 배기가스 DePM, DeSOx 순환처리장치 (Recycle system) 개발

  • 하신영;김인수
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2015년도 추계학술대회
    • /
    • pp.64-65
    • /
    • 2015
  • 본 연구는 PM과 SOx를 효과적으로 저감 시킬 수 있는 Water- Scrubber와 오염물과 세정수의 분리가 가능한 Purifier를 이용한 새로운 순환식 배기가스 세정시스템의 개발하여 PM, PAH 제거효율을 산정한 결과, PM과 PAH모두 유입 수 대비 99%이상 처리되는 것을 확인하였으며, 수질인자도 재사용이 가능한 유입수의 수준으로 분석되었다.

  • PDF

오일 속 미세입자 및 수분분리를 위한 청정기 시스템 개발 (Development of a purifying system to separate minute solid particles and water in oil)

  • 김용근;최윤환;문명준;이연원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권1호
    • /
    • pp.44-49
    • /
    • 2017
  • 본 연구에서는 선박 엔진 오일을 여과하는 검증된 기술인 원심정화기(Centrifugal Filter)를 이용하여 수분배출 구조를 설계하고 적용함으로써, 원심 청정기 시스템(Centrifugal Purifier System)을 개발하고자 한다. 선박엔진에서 윤활 및 냉각을 담당하는 오일은 시간이 경과할수록 미세입자 슬러지가 증가하고 때로는 수분의 유입에 따라 원래의 기능을 담당할 수 없게 되어 엔진내부에 치명적인 기계적 손상을 초래한다. 따라서 수분 제거 원리 고안 및 검증, 적절한 배출 구조 설계를 연구하였으며, 개발된 제품은 공인시험을 통해 유효함을 검증하였다. 이는 실제 선박에서 절실히 필요한 엔진 오일의 수명 연장 및 폐오일 감소, 기계 부품 손상 저감 등에 기여할 것으로 기대한다.

부산 . 경남 일원에서의 음용수 이용 실태조사 (Investigation of Use of Potable Water in Pusan and Kyung nam Area)

  • 김용관
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.27-34
    • /
    • 1991
  • This study was carried out to investigate the use habit of drinking water. The survey data were collected from 1,282 of students and 175 of officers from September 1990 to June 1991 in Pusan city and the South of Kyung sang-do. The use rate of tap water among respondents was 33.5%, and the reasons that the others avoid using tap water were having the risk of heavy metals contamination and unsanitary. The 80% of respondents have drunk spring water or bottled water within two or three years. The keeping method of them were 53% in the refrigerator, and 33% in the indoor. The use rate of water vessels what were equipped in mineral springs was 85%. It's advisable that the picking of mineral water be cautious within two or three days after rain. The holding rate of water purifier in respondents was about 20%, and it was purchased within one or two years and the reliance degree of that in users was below 50%.

  • PDF

비접촉식 자외선램프를 이용한 살균/정화 수도꼭지 (A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp)

  • 민경원;원종헌;이현철;한동열
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

CFD를 이용한 펌프확산 및 수리낙차 방식의 혼화공정 흐름 분석 (MIXING PROCESS FLOW ANALYSIS OF PDM AND HYDRAULIC MIXING BASIN SYSTEM USING CFD)

  • 이성우;장세명;조용
    • 한국전산유체공학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2017
  • The mixing of water and chemicals is an important process in the water purification plant. In this paper, we compare PDM(pump diffusion mixer) and hydraulic mixer at the basin in the mixing process. The proper flow rates are predicted and compared in both mixers using CFD technique. As a result, the flow rate of purifier chemical liquid should be 5% of that of water for the optimal performance of mixing process. The characteristics of the two mixing methods are compared with each other for strong and weak points on the operation of the purification system, discussed in the view point of CFD simulations.

자화육각수 제조기술의 특허 동향분석 연구 (Patent trend analysis research in magnetization hexagon water producing technology)

  • 임상호;이상구
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2327-2331
    • /
    • 2011
  • 본 논문은 세정기의 세척수를 인체에 유익한 자화육각수로 변환시켜주는 기술로서, 세정기로 세척수가 공급되는 유입 관에 자화기를 설치하여 세척수를 인체에 유익한 자화육각수로 변환시켜 사용함에 따라 비데와 변기를 위생적으로 유지 관리하게 해주는 자화육각수 제조 기술에 관련하여 특허를 시계열분석을 통하여 출원이 많은 대표적인 국가별 출원을 분석하였다. 자화육각수 제조 기술 분야의 특허 출원 동향을 살펴보면 대부분 한국과 일본에 의한 특허 출원임을 알 수 있으며, 일본특허는 특허건수와 출원인수가 모두 증가하는 발전기에서 특허건수와 출원인수가 모두 감소하는 퇴조기 단계에 있는 것으로 나타나고 있으며, 미국 및 유럽특허에서는 대체적으로 출원인수와 특허건수가 감소하는 퇴조기 양상으로. 분석 되었다. 따라서 자화육각수를 활용하는 사업에서는 특허 권리차원에서 한국과 일본특허의 출원 동향을 지속적으로 관찰 할 필요가 있으며, 그리고 현재 자화육각수기술은 사업전략구상과 산업지원정책수립이 필요한 단계에 있다. 따라서 향후 자화육각수관련 제품의 연구개발이 다수 예상됨에 따라 관련제조업체나 연구기관에서는 사업화와 특허연구에 유용하게 활용될 수 있을 것이다.

알칼리 이온수기 구동시스템에 관한 연구 (A Study on the Alkali-Ion Water Purifier System)

  • 김영수;한근우;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.566-567
    • /
    • 2012
  • 본 논문에서는 산성수를 전기분해하여 알칼리 이온수를 생성하는 정수 시스템을 제안하였다. 시스템은 크게 전해조, 냉각 유닛, 콤프레서, 정수?터 등으로 구성되어 있다. 특히 알칼리이온수를 생성하기 위해서는 전기분해를 위한 전력변환 회로가 필요하다. 본 논문에서는 알칼리이온수기를 위한 전해조 구동회로를 PSIM을 통한 검증 하였다.

  • PDF

Evaluation of Microbiological Contamination of Water Purifiers at Two Universities in Chungcheong Region

  • Jin Young Yun
    • 대한의생명과학회지
    • /
    • 제29권4호
    • /
    • pp.256-262
    • /
    • 2023
  • The purpose of this study is to investigate microbial contamination in water purifiers from two universities (A and B) in Chungcheong region and to evaluate about the harmfulness of the isolated bacteria to the human. The degree of microbiological contamination of six water purifiers at university A was investigated three times from July 2018 to September 2019, and nine water purifiers at university B were investigated in 2023. The isolated bacteria were biochemically identified using an API kit and Vitek-2 system, and then the bacteria were identified to the species level using MALDI-TOF MS. In addition, the possibility of human infection of the isolated bacteria was evaluated through a literature search. In July 2018 and September 2019, the number of bacteria isolated inside the faucet was below the acceptable standard for hot water, but exceed for cold water in all water purifiers. In January and September 2019, bacteria exceeding the acceptable standards were isolated nine times from the cold water of six water purifies (a total of 12 water purifiers). Bacteria identified by MALDI-TOF MS included anaerobic bacteria (Clostridium novyi, Clostridium themopalmarium etc.), Gram-positive bacilli (Microbacterium testaceum, Arthrobacter woluwensis etc.), and Gramnegative bacilli (Acinetobacter nosocomialis, Comamonas kerstersii etc.), which are difficult identify by biochemical methods. In conclusion, bacteria exceeding the acceptable standard were isolated from the cold water of most of the water purifiers. Most of the isolated bacteria were low-pathogenic bacteria from natural environment, but opportunistic bacteria that can cause infection in humans were also isolated from some water purifiers.

UV-C 조사에 의한 음용수 살균 시스템의 미생물 저해 효과 (Effect of UV-C irradiation for bacterial disinfection of drinking water)

  • 김현중;김윤재;서세영;이창주
    • 한국식품과학회지
    • /
    • 제53권2호
    • /
    • pp.218-222
    • /
    • 2021
  • 본 연구는 그람 음성균과 양성균인 E. coli와 L. monocytogenes를 인위적으로 오염시킨 음용수를 대상으로 UV-C 정수기의 살균 가능성과 미생물의 생육 저해에 따른 형태학적 특성을 조사하였다. UV-C를 이용한 음용수 살균 능력은 그람 음성균 E. coli와 양성균 L. monocytogenes의 저농도부터 고농도(E. coli 3.2×103-3.2×107 CFU/2.8 L; L. monocytogenes 8.4×103-8.4×107 CFU/2.8 L) 세균 모두의 생육을 저해할 수 있는 효과가 나타났다. 따라서 UV를 이용한 음용수 살균은 유속 3.4 L/min에서 UV-C 파장 254 nm, 조사선량 40 mJ/㎠로 조사할 경우 E. coli 3.2×107 CFU/2.8 L와 L. monocytogenes 8.4×107 CFU/2.8 L 이하 농도의 오염된 음용수의 살균이 가능한 것으로 나타났다. 정수기에 UV-C 살균장치를 추가하는 것이 물의 미생물 안전성에 효율적이라고 사료되며, 이 연구결과는 UV살균 장치 활용의 기초자료로 제공되어 향후 연구 수행에 도움을 줄 수 있을 것이다.