• 제목/요약/키워드: water purification system

검색결과 306건 처리시간 0.028초

미나리꽝을 이용한 영양물질제거에 관한 연구 (A Studies on Removal of Nutrient Material by Using Dropwort Field)

  • 이영신;김창회
    • 한국환경보건학회지
    • /
    • 제29권3호
    • /
    • pp.16-20
    • /
    • 2003
  • Nitrogen(N) and phosphorus(P) in surface streams mainly lead to euthrophication. It aggravates water quality and consequently increases the purification costs. As a resolution of water contamination caused by household drainage through irrigation route by 70% of the 1,300 community residents in Eum-Am Myun, Seo-San city, was implemented biological self-purification method by growing Oenanthe Javanica along the polluted water tunnel. The contaminated water was efficiently purified after passing the dropwort field; DO conc. of effluent water was increased 8.3∼61.9% after through the drop wort field. HRT of experiment system was changed 0.05∼1.50/day. 50% of BOD was eliminated at the range above 12 mg/l of Influent BOD conc. Also, 50% of COD was eliminated at the range above 30 mg/l of Influent COD conc. Finnally, the influent T-N loading at range below 1.5 g/m$^3$/d reduced 50% of Influent T-N conc., and so did influent T-P loading at the range below 0.03 g/m$^3$/dwas reduced 50% of Influent T-P conc.

Application of Membrane Technology in Japan

  • Minami, Katsuyoshi
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1995년도 추계 총회 및 학술발표회
    • /
    • pp.58-73
    • /
    • 1995
  • Membrane filtration is a promising technology for efficient solid/liquid separation in water purification. In FY 1991, the Ministry of Health and Welfare, Japanese Government launched a comprehensive research project "MAC 21" for development of membrane technology and its application to public water supply. The project was conducted by the Water Purification Process Association (WPPA), under the supervision of the Institute of Public Health. By the research project from FY 1991 to FY 1993, we confirmed that microfiltration (MF)/ultrafiltration (UF) technology was applicable to water purification and MF/UF was a effective method for the removal of such contaminants as particulate matter and coliforms. The Guideline Committee organized under the Technical Committee prepared a the guidelines on application of membrane system to small-scale public water supplies, based on the results as written above. The guidelines has been published in Dec., 1994 by WPPA.4 by WPPA.

  • PDF

정수장 감시제어망의 관리와 보안개선을 위한 산업용 보안 L2스위치 개발 및 적용사례 (The development of industrial secure L2 switch and introduction example for management and security improvement of supervisory control network in purification plant)

  • 김윤하;유철;오은;김찬문;박익동;김용성;최현주
    • 상하수도학회지
    • /
    • 제33권5호
    • /
    • pp.329-339
    • /
    • 2019
  • Recently, the advancement of information and communication technology(ICT) is expanding the connectivity through Internet of Things(IoT), and the media of connection is also expanding from wire/cable transmission to broadband wireless communication, which has significantly improved mobility. This hyperconnectivity has become a key element of the fourth industrial revolution, whereas the supervisory control network of purification plants in korea is operated as a communication network separated from the outside, thereby lagging in terms of connectivity. This is considered the best way to ensure security, and thus there is hardly any consideration of establishing alternatives to operate an efficient and stable communication network. Moreover, security for management of a commercialized communication network and network management solution may be accompanied by immense costs, making it more difficult to make new attempts. Therefore, to improve the conditions for the current supervisory control network of purification plants, this study developed a industrial security L2 switch that supports modbus TCP(Transmission Control Protocol) communication and encryption function of the transmission section. As a result, the communication security performance improved significantly, and the cost for implementing the network management system using Historical Trend and information of HMI(Human Machine Interface) could be reduced by approximately KRW 200 million. The results of this study may be applied to systems for gas, electricity and social safety nets that are infrastructure communication networks that are similar to purification plants.

신경회로망을 이용한 상수처리시스템의 응집제 주입공정 최적화 (Optimization of coagulant dosing process in water purification system using neural network)

  • 남의석;박종진;장석호;차상엽;우광방;이봉국;한태환;고택범
    • 제어로봇시스템학회논문지
    • /
    • 제3권6호
    • /
    • pp.644-651
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on water quality such as turbidity, temperature, pH and alkalinity. However, the process of chemical reaction to improve water quality (e.g., turbidity) by chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts using Jar-test data. In this paper, a systematic control strategy is proposed to derive the optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride), using Jar-test results. A neural network model is developed for coagulant dosing and purifying process by means of six input variables (turbidity, temperature, pH, alkalinity of raw water, PAC feed rate, turbidity in flocculation) and one output variable, while considering the relationships to the reaction of coagulation and flocculation. The model is utilized to derive the optimum coagulant dosage (in the sense of minimizing turbidity of water in flocculator). The ability of the proposed control scheme validated through the field test has proved to be of considerable practical value.

  • PDF

조석분류를 이용한 연안해역의 수질정화에 관한 수치적 평가 (Numerical Assessment for Coastal Water Purification Utilizing a Tidal Jet System)

  • 박종천
    • 한국해양공학회지
    • /
    • 제20권4호
    • /
    • pp.58-63
    • /
    • 2006
  • When the costal zone surrounded by a breakwater has a narrow vertical opening, currents in the vicinity of a narrow entrance can result in a jet flow, coinciding with the tide. Such a Tidal-Jet Generator(TJG) can change the water mass distribution and transport processes in the domain of influence of the jet. Also, it can decrease the residual time of them. In the present study, the water purification utilizing tidal jets in the coastal zone over constant bathymetry are estimated numerically, using a finite-difference numerical scheme, named the NS-MAC-TIDE method, which isbased on the fully 3D Navier-stokes(NS) equations. The shear velocity near the inlet of the TJG are predicted from the flow field simulation, and are assessed qualitatively with the development of scouring or sediment that is caused by the change of diffusion or sweeping flowup from the seabed of sediment particles. Finally, through solving a transport equation of concentration, the residual time related on mass transport processes and the flushing mechanism for water purification are investigated.

Fabrication and Characterization of Onggi Filter for Appropriate Water Treatment Technology

  • Park, Joon-Hong;Kim, Jin-Ho;Cho, Woo-Seok;Han, Kyu-Sung;Hwang, Kwang-Taek
    • 한국세라믹학회지
    • /
    • 제54권2호
    • /
    • pp.114-120
    • /
    • 2017
  • In underdeveloped countries, many people suffer from water shortage due to the absence of water supply service. Although water purifiers have provided support in such situations, it is not easy to maintain water filters without a continuous supply of consumable filters. To obtain a sustainable drinking water source, appropriate technology of water treatment is necessary. Herein, a low cost water purification system was developed using natural raw materials. A non-electric water treatment system was developed using filtration through an Onggi filter, which is a type of Korean traditional earthenware with a microporous surface. The porosity and flux of the prepared Onggi filter were 29.06% and 31.63 LMH, respectively. After purification of water with total dissolved solids of 10.4 mg/L and turbidity of 100 NTU, the total dissolved solids and turbidity of the water treated using the Onggi filter decreased by 12% and 99.8%, respectively.

저수지 수질개선을 위한 식생정화시스템 (A Vegetation Purification System for Water Quality Improvement in Irrigation Reservoirs)

  • 박병흔
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.87-95
    • /
    • 2000
  • A vegetation purification system was applied to improve water quality of Masan Reservoir in Korea, which was composed of constructed wetlands in series. Five different kinds of macrophytes were planted in each wetland. The system was operated with the condition of low concentrations and high hydraulic loadings. Removal efficiencies(%) of chemical oxygen demand(COD) , total nitrogen(T-N) and total phosphorus(T-P) in this system were 9.0, 12.8, 20.1% , respectively. and removal rates(g/$m^2$/d) were 1.9(COD), 0.34(T-N) and 0.05(T-P) . Comparing this system with other wetlands operated at low hydraulic loadings, average removal efficiencies were low but removal rates were relatively high. Accordingly, this system could be applied to imporve reservoir water quality, because removal rates are more important than removal efficiencies in case of reservoir water quality improvement . However, the removal efficiencies and rates of this system are less than those of the hydroponic biofilter method which is a kind of a constructed wetland and utilize root zones of emergent macrophytes for trapping pollutants. Therefore, it is recommended that this system should be modified to utilize root zones of emergent macrophytes enough to improve reservoir water quality more efficiently.

  • PDF

무방류 재이용 시스템 현장 적용성 평가 (Assessment of Field Applicability of a Zero Discharge and Reuse System)

  • 최경숙;이광야
    • Current Research on Agriculture and Life Sciences
    • /
    • 제29권
    • /
    • pp.75-81
    • /
    • 2011
  • This study performed field examinations of a zero discharge and reuse system developed by Hong and Choi(2009). The system installed one of villages located in Hyoryeong-myeon, Gunwee-gun for the experiments. The zero discharge and reuse system consists of anoxic, FES (Ferrous Electricity System), Oxic, Cralifier processes for water treatments. The main feature of the system is to remove phosphorous by using Fe-ionizing module within the FES process. The water purification performances of the system were evaluated, while any defects for using the system were investigated through the field monitoring. It was found that the removal capacities of T-P, T-N, and BOD of the system meet the required water quality with outstanding performance from T-P by obtaining the results of over 90 % removal rates. The efficiency of T-P removal rate of the system found to be greatly influenced by whether using an automatic washing system to the Fe-ionizing module and conducting replacement of iron plate within a proper period.

  • PDF

재난·재해용 포터블 하이브리드 정수시스템 개발 (Development of Portable Hybrid Water Purifier System)

  • 류지협;최랑규;박훈
    • 한국재난관리표준학회지
    • /
    • 제3권2호
    • /
    • pp.47-55
    • /
    • 2010
  • 재난 재해 발생시 즉각적인 식수 공급이 어려운 점과 재난을 대비한 생수비축의 문제점을 해결하기 위하여 현장에서 비상시 식수생산이 가능한 휴대용 정수시스템을 개발하였다. 정수시스템은 필터, 펌프, 태양전지, 충전 컨트롤러, 케이스 등으로 구성되었으며, 휴대성과 무전원 상태에서도 작동이 가능하도록 비상용 배터리와 태양전지를 갖추어 시간과 장소에 제한없이 현장에서 식수공급이 이루어지도록 하였다. 개발된 휴대용 정수시스템은 현장 성능측정 실험을 수행하였으며 실험결과 정수된 물은 먹는 물 기준을 충족하였다.

  • PDF