• Title/Summary/Keyword: water purification plant

Search Result 208, Processing Time 0.026 seconds

Submerged Type Water Purification System using Hollow Fiber Microfiltration Membrane (중공사 정밀여과막을 이용한 상수처리용 일체형 시스템 개발)

  • Jeong, Gyu-Yeong;Kim, Hyeong-Su;Im, Jong-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • Membrane separation process is considered as an alternative of conventional water purification system using coagulationㆍsedimentation+sand filtration. In this study, it was examined that the application possibility of Hollowfiber Microfiltration membrane for water purification process. A $20m^3/day$ scale pilot plant was used for studying the possibility of long-term operation and the stability of water quality under the optimum conditions, 0.03m/h permeate flux, filtration for 10 minutes, pause for 2 minutes(including air-scrubbing for 30 seconds), obtained by lab-scale experiment. As a result, it was proved stability of pilot plant over one year and filtrate quality(Turbidity. SS etc). Therefore, it was proved that membrane separation process using Hollowfiber Microfiltration membrane can be applied for water purification system

  • PDF

Convergence Study on Organic Sludge Treatment System (유기성 슬러지 처리 시스템에 관한 융합연구)

  • Han, Doo-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.213-217
    • /
    • 2020
  • An eco-friendly water purifier was developed using natural minerals, plants, and sludge from water purification plants. A wastewater complex treatment system using this water purification agent was developed. The wastewater complex treatment system goes through the process of inflow of contaminated water, input of water purification agent, operation of a pressurized flotation device, sludge flotation, sludge collection and treatment water discharge. This device was applied to the removal of green algae in livestock desorption liquid, broiler washing water, factory wastewater, sewage treatment plant and pond to obtain excellent removal rate. The use of natural water purification agents for organic waste purification has not been investigated.

Fuzzy modeling and control for coagulant dosing process in water purification system (상수처리시스템 응집제 주입공정 퍼지 모델링과 제어)

  • 이수범;남의석;이봉국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.282-285
    • /
    • 1996
  • In the water purification plant, the raw water is promptly purified by injecting chemicals. The amount of chemicals is directly related to water quality such as turbidity, temperature, pH and alkalinity. At present, however, the process of chemical reaction to the turbidity has not been clarified as yet. Since the process of coagulant dosage has no feedback signal, the amount of chemical can not be calculated from water quality data which were sensed from the plant. Accordingly, it has to be judged and determined by Jar-Test data which were made by skilled operators. In this paper, it is concerned to model and control the coagulant dosing process using jar-test results in order to predict optimum dosage of coagulant, PAC(Polymerized Aluminium Chloride). The considering relations to the reaction of coagulation and flocculation, the five independent variables(turbidity, temperature, pH, Alkalinity of the raw water, PAC feed rate) are selected out and they are put into calculation to develope a neural network model and a fuzzy model for coagulant dosing process in water purification system. These model are utilized to predict optimum coagulant dosage which can minimize the water turbidity in flocculator. The efficacy of the proposed control schemes was examined by the field test.

  • PDF

Odor Reduction Technology in Sewage Treatment Facility Using Biofilter with Reed Grass(Phragmites australls) (갈대(Phragmites australls)수초를 적용한 바이오필터에서의 하수처리시설 악취저감기술)

  • Chung, Jin-Do;Kim, Kyu-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.3
    • /
    • pp.373-382
    • /
    • 2013
  • In this study, a biological odor treatment system was proposed to remove odor(foul smell) materials causing several problems in the closed sewage treatment plant. This odor treatment system was composed of a two-step biofilter system in one reactor. The two-step biofilter reactor was constructed with natural purification layer in upper part and artificial purification layer in lower part. The reed grasses of water purification plants were planted in the surface area and mixed porous ceramic media were filled with the lower part of biofilter reactor. By using the above experimental apparatus, the ammonia gas removal efficiency was attained to 98.3 % and the hydrogen sulfide gas removal efficiency was appeared more than 97.7 % which shows more effective than the conventional odor removal process.

Investigation on the Excessive Vibration of A Mixer Facility in A Water Purification Plant (정수장용 교반기 시설의 과진동 원인 분석)

  • Park, Jin-Ho;Lee, Jeong-Han;Kim, Bong-Soo;Kang, Mun-Hu;Kim, Dong-Soo;Joo, Yoon-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.312-316
    • /
    • 2002
  • Recently, mixers are being widely used in the water purification plant in order to increase the filtration efficiency. It has been found that a severe vibration was being felt on a upper structure of a mixer facility during steady state operation. The cause of the excessive vibration of the structure to which the mixer's shaft is supported has been evaluated through modal analysis on the shaft and vibration measurements during operation. The fundamental natural frequency of the mixer's shaft is found to be around 1.8 Hz and the main vibratory frequency around 30 Hz. It has been tuned out that the main vibratory frequency, 30 Hz is coincident with the fundamental holding frequency of the upper structure, and that the acceleration signal of the upper structure and the displacement signal of the mixer's shaft showed highly coherent to each other. Accordingly, it reveals that the main cause of the excessive vibration is due not to the mixer's vibration but to the natural frequency of the upper structure excited by flow turbulence.

  • PDF

Performance and Operation of Biological Activated Carbon (생물활성탄접촉조의 성능과 조작)

  • Lee, Gangchoon;Yoon, Taekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.83-90
    • /
    • 2006
  • Performance and operation of BAC in ozone-BAC advanced water treatment process were investigated using the pilot scale test plant built in D water purification plant. The performance was evaluated by the removal efficiencies of DOC, BDOC, ammonia nitrogen and THMs. The effect of EBCT on DOC removal was experimented for an effective operating condition, and the amount of attached biofilm was analyzed in various water temperatures and position of BAC. Two removal mechanisms, adsorption and biological decomposition by attached biofilm, were predominant to decrease the concentration of various contaminants. DOC was removed 40%, and the removal rate was decreased in winter time due to the lowered activity of attached biofilm. BDOC was effectively removed. THMs and ammonia nitrogen were mainly removed not in ozonation process but in BAC. Water temperature deeply influenced in removal efficiency of ammonia nitrogen. The amount of attached biofilm depended on water temperature and height of packed activated carbon column. Considering DOC removal efficiency and design EBCT of commercial BAC plant, the proper EBCT was 12.5 minutes.

A STUDY OF SIMULATION AND CONTROL OF PAC COSING PROCESS IN WATER PURIFICATION SYSTEM

  • Nahm, Euisuck;Lee, Subum;Woo, Kwangbang;Han, Taehan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.75-78
    • /
    • 1995
  • In this paper it is concerned to develop control method using jar-test results in order to predict the optimum dosage of coaglant, PAC(PoliAluminum Chloride). Considering the relations with the reactions with the reaction of coagulation and flocculation, the five independent variables ( e, g, turbidity of raw water, water turbidity in flocculators, temperature, pH, and alkalynity) are selected out of parameters and they are put into calculation to develop a neural network model for PAC dosing process in water purification system. This model is utilized to predict optimum dosage of PAC. That is, the optimum dosage of PAC is searched in neural network model for PAC dosing process to minimize the water turbidity in flocculators. This searching is implemented by means of expert heuristics. The efficacy of the proposed contorl schemem and feasibility of acquired neural network model for PAC dosing contorl in water purification system is evaluated by means of computer simulation.

  • PDF

The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (오수/합병정화조의 배출물 제어시스템 연구)

  • 박주식;김건호;오지영;임총규;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF