• Title/Summary/Keyword: water purification

Search Result 1,029, Processing Time 0.037 seconds

Site Assessment for the Water Purification Effect of Porous Concrete by using Effective Micro-organisms (유용미생물을 이용한 포러스콘크리트의 수질정화특성에 대한 현장평가)

  • Kim, Bong-Kyun;Park, Jun-Seok;Seo, Dae-Seuk;Kim, Wha-Jung;Kim, Yun-Yung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.109-119
    • /
    • 2015
  • In recent years, a rapid growth in the population and urbanization led to an increasing industrial growth. The inadequate treated-wasted water from industry and various non-point sources causes significant negative effects on the stream water. For past few decades, extensive researches have been performed on water purification process. The purpose of this study is to investigate mechanical performance and water purification properties of porous concrete by using effective microorganisms through the site assessment test. The mechanical performance evaluation results showed that the increase void ration caused an decrease in the strength. The optimal mix rate was found to be 15% void rate From the site assessment, it was evaluated that the porous concrete improved the quality of the water and the purification ratios are 34.1 for SS, 14.6% for BOD, 34.9% for COD, 11.4% for T-N, and 12.6% for T-P. The porous concrete and the related purification technique can reduce the non-point pollution sources flowing into the river.

The Development of Information Breakdown Structure for Integrated Management of Water Filtration Plants (정수장 시설공사의 통합관리를 위한 시설물분류체계 개발)

  • Kim, Chang Hak;Kang, Leen Seok;Kim, Hyo Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.863-869
    • /
    • 2017
  • In this study, the information breakdown structure of water purification plant has been made by classifying various the water purification methods and facilities. this can be utilized as a code system of computer for integrating information and analyzing quantitative of environmental impact and calculating cost of maintenance and energy consumption which was used during life cycle of water purification plant. Since the construction information contains many heterogeneous information, it is very important to have a code system for managing the integrated information. In addition, since water purification plant facilities are mainly composed of installation of facilities including many processes, a more detailed classification code is required. Therefore, in this study, the water purification breakdown structure which is not yet attempted in Korea was constructed by using facet classification system.

A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp (비접촉식 자외선램프를 이용한 살균/정화 수도꼭지)

  • Min, Kyoung-Won;Won, Jong-Heon;Lee, Hyun-Cheol;Han, Dong-Youl
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

Application of water control by high fiux MF membrane (고 플럭스 MF막의 정수처리 실용화에 관한 연구)

  • Yong, Hwang-Sang
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.55-63
    • /
    • 2008
  • All over the world, the existing process of water purification needs more flocculants and chlorine due to a gradual decline in the quality of source water. Therefore, the problem of the remaining aluminium and DBPs in purified water is on the rise. To solve this problem, the process of membrane filter has recently come into the spotight. This study reaches the following conclusions concerning TMP variation in order to solve the dropping of flux throgh a membrane filter when operating a membrane filter system in the process of water purification. 1. In case that a cohesion-precipitation process was introduced to pre-treatment of a membrane filter, initial TMP was very satisfactory(0.27kg/cm) in producing the constantly safe quality of water, $0.04{\sim}0.1$(mean 0.05) NTU by pouring 2mg/l of PACI(10% $Al_2O_3$) used for the existing process of water purification in high-density turbidity at a dry or flood season and at occurrence of high algae. 2. As flux increased at 0.5m/day.m, TMP increased 0.05 kgf/cm. 3. As filtering, operation mode of PVDF MF membrane filtering was 48 minutes and 1 cycle of back washing was 42 minutes, flux was increased 1.5m/day.m and TMP increased $0.25{\sim}0.27kgf/cm$. Without back washing, TMP increased 0.03 kgf/cm per a cycle.

Strength and Water Purification Characteristics of Effective Microorganism-applied Volcanic Ash Block (유용미생물을 적용한 화산재 블록의 강도 및 수질정화 특성)

  • Lee, Chung-Won;Chang, Dong-Su;Park, Sung-Yong;Choi, Joong-Dae;Kim, Yong-Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The aim of this study is to investigate strength and water purification characteristics of effective microorganism-applied volcanic ash block using flexural strength test and water quality analysis. The specimens were prepared with volcanic ash from Mt. Baekdusan and Mt. Hallasan, and cement as the ratios of 3.5:1, 4.0:1, 4.5:1, 5.0:1 with and without metakaolin. Flexural strength degraded with increasing of the amount of volcanic ash, and increased with addition of metakaolin as a binder. Based on these results, the optimal ratio for fabricating volcanic ash-cement mixture block is determined as 3.5:1 with metakaolin. Furthermore, from water quality analysis on contaminated water, removal ability of effective microorganism-applied volcanic ash-cement mixture block and caged volcanic ash block against T-N, T-P and SS was highly evaluated because of adsorption due to the large specific surface area of volcanic ash. Hence, volcanic ash-cement mixture block and caged volcanic ash block possibly contribute to water purification.

Assessment of the Applicability of Convergence Technology for Reducing and Blocking Pollution Loads to Rivers through the Utilization of Waterfront Spaces (수변공간을 활용한 오염부하 저감 및 차단 융복합 기술의 하천 적용성 평가)

  • Kim, Bong Kyun;Seo, Dae Seuk;Oh, Jong Min;Park, Jae-Ro
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.238-246
    • /
    • 2016
  • Water purification facilities utilizing three technologies - a detention pond, an artificial wetland and an ecological revetment - were installed in waterfront spaces, including river embankments and watersides that have so far been left neglected, and then their water purification levels were analyzed in this study. The water purification facilities were found to show average removal efficiencies of 48.6% in suspended solid (SS), 30.5% in biochemical oxygen demand (BOD), 18.4% in total nitrogen (T-N) and 27.3% in total phosphorus (T-P) during rainfall. The removal efficiencies during non-rainfall were 33.2% in SS, 28.6% in BOD, 13.7% in T-N and 17.3% in T-P. These results showed that the water purification facilities using a detention pond, an artificial wetland and an ecological revetment can be used as a useful natural water purification technology in in waterfront spaces.

A Study on the Equipment Type of Stream Purification System that Applies Combined Physicochemical and Biological Treatment (물리·화학적 및 생물학적 처리가 결합된 장치형 하천정화 시스템에 관한 연구)

  • Eom, Han Ki;Kim, Sung Chul;Kim, Sung Su;Kim, Sam Ju
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.273-281
    • /
    • 2017
  • The objective of this study is to evaluate the performance of stream purification equipment system combined MBP (Micro Bubble Process) and AGBP (Aerobic Granular Biofilm Process). Based on results, the optimal HRT (Hydraulic Retention Time) of MBP and AGBP set as 0.72 and 2.4 h, respectively. In the results of continuous operation on combined MBP and AGBP, it is possible to achieve a BOD, TSS and T-P removal efficiency of 85, 90 and 94%, respectively. It also confirmed that the water quality of the stream can be purified with increasing circulation flow through water simulation evaluation applied the QUAL-NIER model. Consequently this purification system can resolve the stream purification and dry stream problem.

Purification of Stream Water Quality by Using Rope Media Filter (끈상접촉산화시설을 이용한 하천수질정화)

  • Jung, Yong-Jun;Lim, Ki-Seong
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.238-243
    • /
    • 2006
  • In order to improve the water quality of stream water, the facilities equipped with rope media filter have been examined as a part of national projects. This work may provide design and operating parameters from 2 years monitoring for 2 streams. Depending on the characteristics of streams, the flow rate into the facilities were shown different, where K stream was almost the same and D stream was less than 25% of design flow rate. Although the clogging of filter media was not observed during the operation, the removal of accumulated sludges was required for the stable operation. The removal efficiencies of BOD, SS, T-N and T-P for D stream were 60.5%, 80.1%, 25.2% and 36.2%, respectively. The most important factor for the construction of stream water purification facilities was recommended for the selection of proper sites.

Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System (산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술)

  • Seo, Seong-nyeo;Kim, Young-taek;Park, Chul-hwi
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

Microbial Activity of Gravel Intertidal Zone for Purification of Polluted Near Shore Water

  • Song, Young-Chae;Gu, Ja-Hwan;Park, In-Seok;Yoo, Jong-Su
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.233-239
    • /
    • 2004
  • Microbial activity of biofilm formed on the surface of gravels from intertidal zone was estimated using an aerobic respirometer system, and compared with that of suspended marine microorganisms contained in a near shore water. The maximum oxygen uptake rate of the suspended marine microorganisms was 0.15mg O$_2$/L/hr, indicating the potential of purification of polluted near shore water. For the gravels from the intertidal zone, the maximum uptake rate of oxygen was affected by the vertical positions, but their gross value was 0.77mg O$_2$/L/hr, which was around 5.1 times higher than the purification potential of polluted near shore water by the microorganisms contained in the near shore water. The nitrogen removed by the gravels from the intertidal zone and the marine microorganisms was about 1/20-1/39 times of the total consumption of oxygen, which was similar to that of the phosphate. The gravel intertidal zone contained lots of particulate organics, over than that in the near shore water, and this was confirmed from the large difference between total oxygen consumption and the removed soluble COD in the microbial activity test. This indicates that the gravel intertidal zone plays an important role in controlling the non-point source pollutants from land, as well as self-purification of polluted near shore water by trapping and degrading the particulate organics.

  • PDF