• Title/Summary/Keyword: water potential

Search Result 5,542, Processing Time 0.034 seconds

Research on the Performance of Regenerator using Hot Water from Solar Water Heater(1st paper : On the Effect of Solution Temperature to Regeneration Rate) (태양열 온수기를 이용한 다목적 공조시스템의 재생효율에 관한 연구(제1보 액체흡수제 온도가 재생량에 미치는 영향))

  • Woo, Jong-Soo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.53-61
    • /
    • 2004
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an efficient solar water heater, this study examines a regeneration process using hot water obtained from solar water heater to recover absorption potential by evaporating moisture in the liquid desiccant. In this paper, a solar absorption dehumidifying system with solar water heater is suggested to save the electricity for operating an air conditioner. LiGl(lithium chloride) solution was adopted as a liquid desiccant in the proposed system, and hot water obtained from the solar water heater was used for regenerating the liquid desiccant. As a result, it was clear that the dilute LiCl solution could be regenerated by hot water, and the regeneration rate depends mostly on temperature level of liquid desiccant. The regeneration rates were about 2.4kg/h with $40^{\circ}C$, 4.0kg/h with $50^{\circ}C$, and 6.2kg/h with $60^{\circ}C$ of hot water respectively.

Effects of Soil Moisture Content on Leaf Water Potential and Photosynthesis in Soybean Plants (토양성분이 콩의 잎 수분포텐셜 및 광합성에 미치는 영향)

  • 류용환;이석하;김석동
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.2
    • /
    • pp.168-172
    • /
    • 1996
  • The soil moisture content and its relation to plants may be important in determining the crop growth and yield. The present study was undertaken to evaluate the leaf water potential and photosynthetic activity in soybean plants as affected by the timing of soil water stress. The soybean variety, 'Tachinagaha', was grown in a pot. The 15 day-old seedlings were subject to the three levels of soil moisture content(25, 40 and 55%) for 25 days. Then the treated soybean plants were placed again at the level of 25% soil moisture content for 25 days, and were compared with the control which was well-watered at 40% level for whole growth period. Soybean plants grown under continuous drought showed higher apparent photosynthetic rate(AP) than those under well-watering /drought in the first /second water treatment, suggesting that AP was adjusted after previous acclimation to drought. Over a wide range of photosynthetic photon flux densities(PPFD), drought or excessive water stress resulted in the decrease in AP when compared with the control. AP and stomatal conductance were decreased in soybean plants subject to water deficit stress, suggesting that AP and stomatal conductance were more sensitive to drought than excessive water stress.

  • PDF

Genotypic Variation in Leaf Water Status of Soybean

  • Jin, Yong-Moon;Lee, Hong-Suk;Lee, Suk-Ha;Kwon, Yong-Woong;Im, Jeong-Nam
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.1
    • /
    • pp.55-58
    • /
    • 1999
  • Plant water status during growth is directly and indirectly associated with seed yield. The objective of the present study was to determine the genotypic differences in leaf water characteristics at an early growth stage of soybean [Glycine max (L.) Merrill] plants through the pressure-bomb technique. Measurements of water potential as well as relative water content (RWC) were made at the third leaf from the fully-expanded top leaf of eight different soybean genotypes grown for 31 to 35 days after field emergence. On the basis of the modified exponential model, pressure-volume (PV) curves were fitted well ($R^2$=0.92** to 0.99** for the curvi-linear region and R=0.67** to 0.96** for the linear region), indicating that a segmented model using PROC NLIN of SAS could be used effectively to estimate the leaf water characteristics. The regression analysis for the pressure-volume (PV) curve revealed genotypic variation in the solute potential at saturation (Ψ$_{s,sat}$ :-10.7 to -14.8 bar), solute potential at incipient plasmolysis (Ψ$_{s,ip}$ : -14.3 to -18.3 bar), RWC at incipient plasmolysis (RW $C_{ip}$ : 83.3 to 91.7%), high integrated turgor pressure from saturation to plasmolysis ( $_1$$^{b}$ : 0.39 to 0.81), and maximum volumetric modulus of elasticity ($\varepsilon$$_{max}$ : 150 to 445 bar).).

  • PDF

Optimum Water Potential, Temperature, and Duration for Priming of Rice Seeds

  • Lee, Suk-Soon;Kim, Jae-Hyeun;Hong, Seung-Beom;Kim, Min-Kyeong;Park, Eui-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.43 no.1
    • /
    • pp.1-5
    • /
    • 1998
  • Experiments were carried out to find out the optimum water potential, temperature, and duration for the priming of rice seeds, Oryza sativa L. (cv. Ilpumbyeo) for better germination at sub-optimal temperatures. Seeds were primed in 0, -0.2, -0.4, -0.6, -0.8, and -1.0 MPa PEG (polyethylene glycol) solutions at $25^{\circ}C$. The optimum water potential for seed priming, the highest water potential at which rice seeds did not germinate, was -0.6 MPa. To find out optimum priming temperature and duration rice seeds were primed in -0.6 MPa PEG solution and 0 MPa (water as a control) for various durations at 15 and $25^{\circ}C$ and the seeds were germinated at 17, 20, and $25^{\circ}C$. Considering germination rate and speed, the optimum priming time in water (0 MPa) was 4 days at 15$^{\circ}C$ and 1 day at $25^{\circ}C$, while 4 days was the optimum priming time in a -0.6 MPa PEG solution, regardless of the priming temperature. Priming reduced the actual time of germination, especially at sub-optimal temperatures. Priming did not affect germination rate in -0.6 MPa PEG solution at 15$^{\circ}C$, but overpriming reduced the final germination rate in water at 15$^{\circ}C$ and in -0.6 PEG solution at $25^{\circ}C$. Total sugars and $\alpha$-amylase activity induced during the seed priming were negatively correlated with the final germination rate and there was no noted relationship with the speed or uniformity of germination.

  • PDF

Effects of Water Treating on Surface Properties of Epoxy Insulation Materials (Epoxy 절연재료이 표면특성에 미치는 수분처리의 영향)

  • Lim, Kyung-Bum;Lee, Duck-Chool
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.10
    • /
    • pp.553-558
    • /
    • 2000
  • This paper deals with change of contact angle, surface potential decay, surface resistivity and XPS of water-treated epoxy insulator. From the experimental results on the contact angle was reduced from $74^{\circ}$to $24^{\circ}$ due to the formation of polar hydroxyl groups on surface which was associated with intermolecular reaction between epoxy chains of three-dimensional network structure and water molecules. From the experimental results in the surface potential decay of water treated-samples, it was found that the accumulation of charge is decreased and the surface potential decay time is shortened by the interaction of polar hydroxyl groups induced on the treated surface as the increment of treatment time. The positive charging on the treated surface compared with negative charging is relatively lowered by the induction of polar hydroxyl groups. The surface resistivity was changed from $10^{15}[{\Omega}/cm^2$] to $10^{12}[{\Omega}/cm^2$] caused by water treatment. From XPS, it was found that the changes affected by the surface degradation of epoxy were caused by the generation of carboxyl groups through the chain decomposition and recombination with oxygen molecules in the air.

  • PDF

A Study on the Evaluation of Potential Hydro-electric Power in North Korea (북한의 수력발전가능량 산정 및 평가에 대한 연구)

  • Park, Miri;Ahn, Jaehyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.41-49
    • /
    • 2018
  • This study is to analyze and evaluate water resource development potential in North Korea. The study was conducted to analyze selected potential hydropower as an indicator to evaluate water resource development potential. Potential hydropower means theoretical value about the potential capacity of river. It is used to evaluate the amount of development through the hydropower generation. For calculating potential hydropower, monthly average and annual average of rainfall for each river basin were calculated by using the data of 27 rainfall stations in North Korea. As a result of the calculation of theoretical potential hydropower by rainfall in the seven major basins in North Korea, the Aprok River basin was analyzed to be the largest with $7,562.2{\times}10^3kW$. The efficiency and utilization rate of theoretical potential hydraulic power in South Korea and North Korea was 42.3% and 36.2%, respectively. The Daedong River basin's potential hydropower utilization rate is 12.3%, which is the lowest in North Korea. In the case of Daedong River basin, more than 40% of the total population is inhabited, so demand for water and electricity is expected to be the largest. Therefore, the Daedong River basin is considered as a priority area for water resource development. The results of this study are expected to be used as basic data for future water resource development projects and research activities in North Korea.

General Characteristics of the East Sea Intermediate Water (동해중층수의 일반적인 분포 특성)

  • Shin, Chang-Woong;Byun, Sang-Kyung;Kim, Cheol-Soo;Lee, Jae-Hak;Kim, Bong-Chae;Hwang, Sang-Chull;Seung, Young-Ho;Shin, Hong-Ryeol
    • Ocean and Polar Research
    • /
    • v.29 no.1
    • /
    • pp.33-42
    • /
    • 2007
  • To obtain the overall distribution patterns and characteristics of the East Sea Intermediate Water (ESIW), the historical data obtained by the Japan Maizuru Marine Observatory (MMO) and the Korea Ocean Research and Development Institute (KORDI) were analyzed. To obtain water characteristics of the ESIW on isopycnal surfaces, temperature, salinity and dissolved oxygen were interpolated at every 0.01 interval of potential density. And then the interpolated values were averaged at the same potential density. This potential density average method preserved the salinity minimum layer more clearly compared to the depth average method. The potential density(${\sigma}_{\theta}$) range of the ESIW was $26.9{\sim}27.3$. The representative potential density of the ESIW was found to be 27.2, because the characteristics of the ESIW was clear at this density. From the horizontal distributions of physical properties on the isopycnal surface of $27.2{\sigma}_{\theta}$ it is suggested that the low salinity ESIW circulates anticlockwise over the whole basin with the high salinity intermediate water. The low salinity intermediate water extended from the northwestern part to the east along the sub-polar front and to the Ulleung Basin along the east coast of Korea.

Modified Electrical Resistivity Survey for Leakage Detection of a Waterside Concrete Barrage (콘크리트 수변구조물의 누수 탐지를 위한 변형된 전기비저항 탐사 연구)

  • Lee, Bomi;Oh, Seokhoon;Im, Eunsang
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.3
    • /
    • pp.115-124
    • /
    • 2015
  • A modified electrical resistivity survey has been suggested and applied to a leakage detection problem of concrete barrage. We suggest the modified electrical resistivity methods using electrodes floating on the water and apply line current sources instead of conventional point current sources in order to facilitate simple analysis. In addition, the study introduced the following three variations of modified electrode array: Direct potential array, Parallel potential array and Cross potential array. These arrays were tested and investigated through numerical experiment, physical model experiment and geophysical field exploration in order to verify their applicability to the water leakage detection of a concrete barrage. When water leakage occurred, all kind of array operations demonstrated distinct changes of aspects of potential difference in graphs obtained by not only the numerical and physical model experiments but also geophysical field exploration. Therefore, this modified electrode arrays of electrical resistivity survey, which has been adapted to the concrete barrage, has been found to be a useful method to detect water leakage.

Formation Characteristics of DBPs by Chlorination in Water Treatment Plant (정수장에서 소독부산물의 생성특성)

  • Rhee, Dong-Seok;Min, Byoung-Seob;Park, Sun-Ku;Kim, Joung-Hwa;Rhyu, Jae-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.55-62
    • /
    • 2004
  • This study was carried out to investigate the formation of DBPs(Disinfection By-products) such as trihalomethane(THMs) and haloacetic acid(HAAs) by chlorination in raw water and finished water of Water Treatment Plant(WTP). The formation of THMs was increased with the increase of pH and reaction time. HAAs was found as a high formation at a pH 7 and low formation at pH 9. THMFP(Trihalomethane Formation Potential) was the highest formation potential in raw water of Pu-1 and the lowest in raw water of Pa-1. In case of HAAFP(Haloacetic acid formation potential), So-1 showed the highest value, while Pa-1 showed the lowest value. It was investigated the relationship between HAAs and organic matters which were described as DOC(dissolved organic carbon) and $UV_{254}$. In both DOC and $UV_{254}$ versus HAAFP, Pu-1 showed the good correlation coefficients($r^2$) with 0.95 and 0.84, respectively. For three WTP investigated, DBPs(THMs + HAAs) was shown over the range of $42.00{\sim}49.36{\mu}g/L$. This result might be due to the different characteristic of organic matters in raw water and the difference of chlorine dosage for a water treatment.

A Study on the Activation of Non-government Participation in Total Maximum Daily Load System using Private Discharge Facilities Reduction Potential Analysis (개별배출시설 삭감잠재량 분석을 통한 수질오염총량제의 민간참여 활성화 방안 연구)

  • Kim, Hongtae;Shin, Dongseok;Kim, Hyeonjeong;Choi, Inuk;Lee, Miseon;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.6
    • /
    • pp.715-722
    • /
    • 2015
  • Four major river basin in Korea has been managed with Total Maximum Daily Load(TMDL) System. Water quality indicators as targeted pollutants for TMDL were BOD and TP. In order to satisfy water quality criteria, government allocation using public treatment facilities and its action plan has been used. However, the role to improve water quality were recently faced to its limitation. It is time to require the role of non-government allocation in private discharge facilities to control good water quality. This study investigated three different scenarios in reduction demands of non-government allocations about industry and private sewages. The three different scenarios were discharge under 1) legal water quality standard, 2) water quality level in 2011 and 3) current water quality level with maximum value in group. The results showed that reduction potential in water discharge for TP indicator was 1,118kg/day, under second scenario with 20% of deduction. This results arrived at 42% of whole reduction potential costs and 0.012mg/L improvement in water quality. In conclusion, to intrigue voluntary participation in non-government allocation, various benefits such as tax reduction, tax exemption, and water quality trading should be provided.