• Title/Summary/Keyword: water pipe monitoring

검색결과 63건 처리시간 0.036초

지하철 누설전류 무선 원격 감시시스템 적용 사례 (A case study of remote wireless monitoring system for stray current due to subway system)

  • 배정효;하윤철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1817-1818
    • /
    • 2006
  • In present, most of metallic structures (gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway in Seoul and Pusan.In this case, subway system make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential, amplitude of stray current, point of source of stray current and so on. In this paper, results of development about Wireless Remote Monitoring and Control System on Underground Pipeline in Stray Current Conditions are presented. And also field test data should be reporting.

  • PDF

그라우팅을 병행한 강관추진공법의 현장 적용성 연구 (In-Situ Application of the Steel Pipe jacking with Grouting)

  • 정민형;임호정;신창섭;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권1호통권53호
    • /
    • pp.152-160
    • /
    • 2009
  • 강관추진공법은 비굴착공법으로써 중소규모 관로공사에 높은 시공성과 경제성을 가지고 있기 때문에 그 사용이 빈번해지고 있다. 그러나 강관추진공법의 추진과정은 원지반이 교란되고 느슨해지는 문제를 야기하고 있다. 이는 지표침하, 지반강도 저하 및 누수 등의 문제와 연결된다. 이에 본 연구는 강관추진과 동시에 그라우팅을 시행하는 그라우팅을 병행한 강관추진공법의 현장 적용성을 알아보고자 한다. 그 방법으로 그라우팅을 병행한 강관추진공법과 기존강관추진공법을 동일 지반에 시공하였다. 지표침하 계측, 현장밀도, GPR 물리탐사 그리고 대형전단실험의 결과는 그라우팅을 병행한 강관추진공법의 현장 적용성이 있음을 입증하였다.

150℃에서 원전 2차측 배관재료의 Cr함량에 따른 유체가속부식 특성 (Effect of Cr content on the FAC of pipe material at 150℃)

  • 박태준;김홍표
    • Corrosion Science and Technology
    • /
    • 제12권6호
    • /
    • pp.274-279
    • /
    • 2013
  • Flow accelerated corrosion (FAC) of the carbon steel piping in nuclear power plants (NPPs) has been major issue in nuclear industry. During the FAC, a protective oxide layer on carbon steel dissolves into flowing water leading to a thinning of the oxide layer and accelerating corrosion of base material. As a result, severe failures may occur in the piping and equipment of NPPs. Effect of alloying elements on FAC of pipe materials was studied with rotating cylinder FAC test facility at $150^{\circ}C$ and at flow velocity of 4m/s. The facility is equipped with on line monitoring of pH, conductivity, dissolved oxygen(DO) and temperature. Test solution was the demineralized water, and DO concentration was less than 1 ppb. Surface appearance of A 106 Gr. B which is used widely in secondary pipe in NPPs showed orange peel appearance, typical appearance of FAC. The materials with Cr content higher than 0.17wt.% showed pit. The pit is thought to early degradation mode of FAC. The corrosion product within the pit was enriched with Cr, Mo, Cu, Ni and S. But S was not detected in SA336 F22V with 2.25wt.% Cr. The enrichment of Cr and Mo seemed to be related with low, solubility of Cr and Mo compared to Fe. Measured FAC rate was compared with Ducreaux's relationship and showed slightly lower FAC rate than Ducreaux's relationship.

매설관 주변부 누수 탐지를 위한 매설형 TDR 모듈 개발 (Development of Buried Type TDR Module for Leak Detection from Buried Pipe)

  • 홍원택
    • 한국지반환경공학회 논문집
    • /
    • 제22권11호
    • /
    • pp.31-37
    • /
    • 2021
  • 매설관으로부터의 누수에 의한 지반 내 공동 및 이완구간 형성에 따른 사고를 사전에 방지하기 위하여 매설관의 파손 및 누수와 동반한 지반 내 함수상태 변화의 평가가 요구된다. 흙의 함수상태 평가를 위한 기법으로써 시계열반사계(TDR)의 적용이 고려될 수 있으나 표준 TDR 프로브의 경우 세장비가 매우 큰 전극을 이용하므로 지반 내 설치 시 전극의 변형 및 파손이 발생할 수 있다. 본 연구에서는 지반 내에서 안정적으로 형태를 유지하며 함수상태를 평가할 수 있는 매립형 TDR 모듈을 개발하였다. 매립형 TDR 모듈은 동축케이블의 내부도체 및 외부도체에 연결되는 세 개의 전극과 지반 내에서 전극의 변형방지 및 평행배열 유지를 위한 MC Nylon 재질의 케이싱으로 구성된다. 매립형 TDR 모듈로부터 획득된 유도전자기파의 신뢰도 검증을 위하여 표준 TDR 프로브로부터 획득한 유도전자기파와 상호비교 하였으며 보정실험을 통하여 체적함수비와 유도전자기파의 전파시간 상관관계가 수립되었다. 매립형 TDR 모듈의 현장적용 적정성을 평가하기 위하여 실내 모형실험이 수행되었으며, 모형 매설관으로부터의 누수에 따른 흙 시료의 체적함수비 변화가 명확히 관찰되었다. 그러므로 본 연구에서 개발된 매립형 TDR 모듈은 도심지 포장 하부에 설치된 매설관의 건전도 평가 및 매설관 주변부 지반의 함수상태 평가에 효과적으로 이용될 수 있을 것이라 판단된다.

상수관 파열 사고로 인한 흙막이 가시설 계측사례 연구 (A Study on the Monitoring Case of the Soil Blocking Facilities Due to Water Pipe Rupture Accident)

  • 우종태
    • 한국재난정보학회:학술대회논문집
    • /
    • 한국재난정보학회 2023년 정기학술대회 논문집
    • /
    • pp.244-246
    • /
    • 2023
  • 아파트 신축공사 흙막이 가시설 현장에 근접 매설된 상수관의 누수 및 파열 사고로 인접 건물이 공사현장 방향으로 58~188mm 기울어졌으며, 지중수평경사계 계측결과 21.07.20일 22.64mm가 21.10.18.일 101.46mm로 급격하게 78.82mm의 큰 수평 변위가 발생되었으며, 이로 인해 흙막이 가시설의 사보강재가 변형되고 토류판 일부가 파손되었다.

  • PDF

이중보온관 부식감지선의 응력부식파괴에 관한 연구 (A study on Stress Corrosion Cracking of Sensor Wire in Thermally Insulated Underground Pipeline)

  • 최윤제;김정구
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.103-111
    • /
    • 2002
  • The thermally insulated underground pipelines have been used for district heating system. The sensor wire embedded in the insulation was used for monitoring the insulating resistance between the sensor wire and the pipe. The resistance measurement system detects corrosion of steel pipe under insulation. The corrosion and stress corrosion cracking(SCC) characteristics of sensor wire in synthetic ground water were investigated using the electrochemical methods and constant load SCC tests. The polarization tests were used to study the electrochemical behavior of sensor wire. The sensor wire was passivated at temperatures ranging from 25 to $95^{\circ}C$. However, the applied sensing current larger than passive current resulted in breakdown of passive film. The constant load SCC tests were performed to investigate the effects of applied current and load on the fracture behavior. Stress-corrosion cracks initiated at pits that were produced by sensing current. The growth of the pit involves a tunnelling mechanism, which leads to ductile fracture.

배급수 계통에서 부식억제제 적용에 따른 부식과 적수와의 상관관계 (Correlation between Corrosion Rate and Red Water on Application of Corrosion Inhibitor in Drinking Water Distribution System)

  • 우달식;구성은;이병두;김주환;문광순
    • 상하수도학회지
    • /
    • 제19권1호
    • /
    • pp.68-77
    • /
    • 2005
  • This study was performed to evaluate the application of corrosion inhibitor and to examine the correlation between corrosion rate and red water in a series of batch tests and a test using auto corrosion monitoring system at A water treatment plant in Gyeonggido. The corrosion study in the auto corrosion monitoring system indicated that Fe concentration decreased by 30~50% and corrosion rate also reduced remarkably with corrosion inhibitor at $1.8mg\;PO_4/L$. After addition of corrosion inhibitor, it was indicated the effective adsorption of the inhibitor on the surface of the pipe line forming a protective film. The corrosion rate increases with the increase in Fe concentration. With $1.8mg\;PO_4/L$ of corrosion inhibitor, the corrosion rate decreased remarkably. Fe concentration had correlation to not only red water problems but also the corrosion rate that actually dissolved into the water, primarily due to the deposition of oxidized iron or other compounds as a scale, which serves as a large reservoir of corrosion by-product. Therefore, corrosion rate can be estimated by Fe concentration. For these reasons, an effective corrosion inhibitor is also an effective red water control reagent. The effect of the corrosion inhibition can last for some time even the application the corrosion inhibitor is discontinued. For the cost effective and efficient corrosion control, the concentration and timing of corrosion inhibitor addition must be determined properly.

임베디드 프로그램으로 재구성한 윈도우 기반 지하관망 모니터링 시스템의 구현 (Implementation of Windows Based Underground Pipe Network Monitoring System Reproduced with Embedded Program)

  • 박준태;홍인식
    • 한국멀티미디어학회논문지
    • /
    • 제14권8호
    • /
    • pp.1041-1049
    • /
    • 2011
  • 사회의 발전과 함께 사회 기반을 구성하는 시설물들의 관리에 대한 연구가 지속되고 있으며, 사회 각 분야에서는 다양한 아이디어를 바탕으로 새로운 시스템을 구축하여 왔다. 그 중 상수도 관망 관리를 위해서 현재 시공되어 운영되고 있는 RTD-1000은 누수 및 파손 등을 원격으로 감지하는 기기로써, PC 기반의 시스템 형태를 가지고 있다. 하지만 PC 기반에서 오는 리소스 소비, 발열, 소비전력이 크다는 취약점이었다. 본 논문에서는 RTD-1000의 취약점을 보완한 개량된 시스템인 RTD-2000을 제안한다. 이 시스템은 WinCE 기반의 ARM9 개발 킷과 LCD가 제거된 TDR만으로 설계 및 구현되었다. RTD-1000에 탑재되었던 윈도우 기반의 각종 감지 프로그램들은 ARM9 기반의 전용 임베디드 S/W로 대체하였고, 성능 비교를 위하여 시뮬레이션 및 평가를 수행하였다.

EPANET을 이용한 상수도 관망의 잔류염소 거동 예측 (Chlorine Residual Prediction in Drinking Water Distribution System Using EPANET)

  • 유희종;김주원;정효준;이홍근
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2003
  • In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.

구제역 가축매몰지 인근 지하수 관측정 수질 모니터링 (Water Quality Monitoring through Tube-Well Survey at Foot-and-mouth Disease Carcass Disposal Sites)

  • 허인량;김계월;최금종;이택수
    • 한국환경보건학회지
    • /
    • 제40권1호
    • /
    • pp.47-54
    • /
    • 2014
  • Objectives: The purpose of this study is to evaluate the characteristics of leachate discharged from livestock burial sites in Gangwondo resulting from foot-and-mouth disease by monitoring the water quality at the survey tube-wells installed near livestock burial sites in order to investigate the effect of the leachate on the quality of nearby underground water and suggest a water pollution level in accordance with water quality evaluation criteria. Methods: To minimize the secondary environmental pollution damage caused by leachate at burial sites of livestock killed by foot-and-mouth disease, this study analyzed the leachate directly discharged from burial sites and installed survey tube-wells within 300 meters of livestock burial sites and investigated water quality as a means to ascertain the environmental effect of the leachate from the burial sites. In accordance with environmental management guidelines on livestock burial sites, this research investigated the water quality in the survey tube-wells in fifty five burial sites in Gangwondo. The elements investigated were $NH_3$-N, $Cl^-$, $NO_3$-N, conductivity, and E. coli. Water quality was monitored from 2011 to 2013. Results: The water quality from the drain pipe at the location of leachate from livestock burial sites showed BOD 37,209 mg/L, COD 8,829 mg/L, $NH_3$-N 3,633 mg/L, and $Cl^-$ 580 mg/L. According to the monitoring results of water quality ($Cl^-$, $NH_3$-N, conductivity) at the survey tube-wells, there was suspicion that 13 out of 55 burial sites discharged leachate, five sites discharged highly concentrated leachate (13%): one in Gangneung, one in Wonju, and three in Cheorwon. Conclusion: It was judged that out of thirteen observation wells which showed a possibility of discharged leachate, three survey tube-wells have established the discharge effect of leachate at burial sites up to recently. Therefore, it is judged that it is necessary to continue monitoring them and devise additional measures.