• Title/Summary/Keyword: water permeability of joint test

Search Result 9, Processing Time 0.027 seconds

The permeability charateristic of Z-type sheet pile joints under water sealing conditions (Z형 강널말뚝의 오염물질 차단효과)

  • Hong, Seung-Seo;Lee, Yong-Soo;Chung, Ha-Ik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1283-1288
    • /
    • 2009
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

Permeability Evaluation of OPC and GGBFS Concrete with Cold Joint (콜드조인트를 가진 OPC 및 GGBFS 콘크리트의 투수성 평가)

  • Choi, Se-Jin;Kim, Seong-Jun;Moon, Jin-Man;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.435-441
    • /
    • 2015
  • Concrete, as a porous media, has permeability and it is considered as a major parameter for durability evaluation. Cold joint caused by delayed placing of concrete accelerates water permeation and intrusion of harmful ions. In the paper, concrete specimens containing GGBFS (Ground Granulated Blast Furnace Slag) and OPC (Ordinary Portland Cement) are prepared with cold joint section, and water permeability and water flow at the age of 91 days are measured for 2 weeks. Sound concrete with GGBFS shows decreased permeability to 89% for sound concrete with OPC and 0.86 of decreasing ratio is evaluated in GGBFS concrete with cold joint. Through WPT (Water Penetration Test), the effects of mineral admixture and cold joint on water permeability are evaluated, and variation in water behavior via cold joint is analyzed through probabilistic method as well.

The Permeability Characteristic of Z-Type Sheet Pile Joints under Water Sealing Conditions (지수조건에 따른 Z형 강널말뚝 연결부의 투수특성)

  • Chung, Ha-Ik;Lee, Yong-Soo;Hong, Seung-Seo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • In general steel sheet piles are used in the containment system, which are vertical barrier systems for waste disposal and landfill purposes, and roads in excavation for temporary structure. This paper presents case study of the use of an interlocking sheet pile for water and containment. Cut-off Z-type sheet pile joints are investigated to determine their permeability from the field test. Four different joint sealing materials are used in field test. The results showed joint permeability is significant time-dependent and joint-dependent. These are explored and conclusions on permeability characteristics of different sealants are noted. A case study gives a design example as well as suggestion on permeability and water tightness can be implemented in using the sheet pile barrier in civil and environment works. From the test results, the effective sealing programs of sheet pile interlocks are suggested.

  • PDF

An Experimental Study on the Roof Exposure Waterproofing Method of Tenon Jointing Type used Shiplap Rubberized Asphalt Color Sheet (반턱 고무 아스팔트 칼라 시트를 이용한 접합부 맞춤식 옥상 노출 방수공법에 관한 실험적 연구)

  • Lee, Jung-Hoon;Lee, Sun-Gyu;Kwak, Hyo-Ya;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.73-77
    • /
    • 2008
  • In this study, we would like to study on the application of roof exposure waterproofing method of joint stability through shiplap rubberized asphalt color sheet to complement problem of fracture, exfoliation and water leakage by existing roof exposure sheet waterproofing material joint weakness. Accordingly, examined basis performance and stability for joint that shiplap rubberized asphalt color sheet through test of that tensile strength, bonding strength, water permeability after bonding, peel resistance after bonding, lengthen resistance after bonding and hang resistance after bonding. The results of this study, waterproofing method to using shiplap rubberized asphalt color sheet is judged to solved fracture, exfoliation and water leakage problems happened in joint by problem was joint of exposure sheet by minimizing gap of joint being integration by shiplap.

  • PDF

Estimating of water pressure to avoid hydraulic fracturing in water pressure test

  • Amnieh, Hassan Bakhshandeh;Masoudi, Majid
    • Computers and Concrete
    • /
    • v.19 no.2
    • /
    • pp.171-177
    • /
    • 2017
  • Water pressure test operation is used before the grouting to determine the rate of penetrability, the necessity and estimations related to grouting, by the penetration of water into the borehole. One of the parameters which have the highest effect is pressure of water penetration since the application of excessive pressure causes the hydraulic fracture to occur in the rock mass, and on the other hand, it must not be so small that prevents from seeing mechanical weaknesses and the rate of permeability. Mathematical modeling is used for the first time in this study to determine the optimum pressure. Thus, the joints that exist in the rock mass are simulated using cylindrical shell model. The joint surroundings are also modeled through Pasternak environment. To obtain equations governing the joints and the surroundings, energy method is used accompanied by Hamilton principle and an analytical solution method is used to obtain the maximum pressure. In order to validate the modeling, the pressure values obtained by the model were used in the sites of Seymareh and Aghbolagh dams and the relative error rates were measured considering the differences between calculated and actual pressures. Modeling in the sections of Seymareh dam showed 4.75, 3.93, 4.8 percent error rates and in the sections of Aghbolagh dam it rendered the values of 22.43, 5.22, 2.6 percent. The results indicate that this modeling can be used to estimate the amount of pressure for hydraulic fracture in water pressure test, to predict it and to prevent it.

A study on the characteristic of adhesion on the low temperature concrete of self adhesive waterproofing sheet using interface leakage test. (계면 누수를 통한 자착형 방수시트의 저온 부착 특성에 관한 연구)

  • Choi, Su-Young;Kim, Meong-Ji;Lee, Jung-Hoon;Choi, Sung-Min;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.234-235
    • /
    • 2014
  • Recently, waterproof construction used to self adhesive waterproofing sheet in the actual field in winter for reduce cost and term. However self adhesive waterproofing sheet's quality is declined in low temperature condition. So, this study was to confirm on the low temperature condition of concrete substrate effecting the adhesion of self adhesion waterproofing sheet using interface leakage test. As a result of this study, self adhesion waterproofing sheet must not be used at temperature below 5℃. Also, adhesion between waterproofing sheet and concrete is declined in low temperature.

  • PDF

Development of High-Frequency Induction Heating Method Using Adhesive Waterproofing Sheet Laminated with Aluminum Sheet (알루미늄 박판 점착 복합 방수시트를 이용한 고주파 유도가열 방수공법 개발 평가 연구)

  • Kim, Yun Ho;Kim, Dong Bum;Park, Jin-Sang;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.111-114
    • /
    • 2011
  • Waterprooping Method with sheet need to study technology and multilateral verification considering the arctic conditions as low temperature and humidity, which is the result only considered of material aspects without environmental condition in construction But there are no measures up until now. To solve this problem by using high frequency induction heating method developed waterproof sheets, cold (5 ℃ or less) can be applied in a more stable environment, water-resistant materials and construction methods were studied for development. The results of the test showed that high frequency induction heating method is effective for usability in low temperature condition and securement of proper quality than existing Waterprooping Method with sheet need.

  • PDF

Trends in Predicting Groutability Based on Correlation Analysis between Hydrogeological and Rock Engineering Indices: A Review (수리지질 및 암반공학 지수 간 상관분석을 통한 절리암반 내 그라우트 주입성 예측 연구 동향: 리뷰논문)

  • Kwangmin Beck;Seonggan Jang;Seongwoo Jeong;Seungwoo Jason Chang;Minjune Yang
    • The Journal of Engineering Geology
    • /
    • v.33 no.2
    • /
    • pp.307-322
    • /
    • 2023
  • Rock-mass grouting plays a crucial role in the construction of dams and deep caverns, effectively preventing seepage in the foundations, enhancing stability, and mitigating hazards. Most rock grouting is affected by hydrogeological and rock engineering indices such as rock quality designation (RQD), rock mass quality (Q-value), geological strength index (GSI), joint spacing (Js), joint aperture (Ap), lugeon value (Lu), secondary permeability index (SPI), and coefficient of permeability (K). Therefore, accurate geological analysis of basic rock properties and guidelines for grouting construction are essential for ensuring safe and effective grouting design and construction. Such analysis has been applied in dam construction sites, with a particular focus on the geological characteristics of bedrock and the development of prediction methods for grout take. In South Korea, many studies have focused on grout injection materials and construction management techniques. However, there is a notable lack of research on the analysis of hydrogeological and rock engineering information for rock masses, which are essential for the development of appropriate rock grouting plans. This paper reviews the current state of research into the correlation between the grout take with important hydrogeological and rock engineering indices. Based on these findings, future directions for the development of rock grouting research in South Korea are discussed.

Grouting Improvement through Correlation Analysis of Hydrogeology and Discontinuity Factors in a Jointed Rock-Mass (절리 암반의 수리지질 및 불연속면 특성 간 상관분석을 통한 그라우팅 계획 수립의 개선 방안)

  • Kwangmin Beck;Seonggan Jang;Seongwoo Jeong;Minjune Yang
    • The Journal of Engineering Geology
    • /
    • v.34 no.2
    • /
    • pp.279-294
    • /
    • 2024
  • Large-scale civil engineering structures such as dams require a systematic approach to jointed rock-mass grouting to prevent water leakage into the foundations and to ensure safe operation. In South Korea, rock grouting design often relies on the experience of field engineers that was gained in similar projects, highlighting the need for a more systematic and reliable approach. Rock-mass grouting is affected mainly by hydrogeology and the presence of discontinuities, involving factors such as the rock quality designation (RQD), joint spacing (Js), Lugeon value (Lu), and secondary permeability index (SPI). This study, based on data from field investigations of 14 domestic sites, analyzed the correlation between hydrogeological factors (Lu and SPI), discontinuity characteristics (RQD and Js), and grout take, and systematically established a design method for rock grouting. Analysis of correlation between the variables RQD, Js, Lu, and SPI yielded Pearson correlation (r) values as follows: Lu-SPI, 0.92; RQD-Lu, -0.75; RQD-Js, 0.69; RQD-SPI, -0.65; Js-Lu, -0.47; and SPI-Js, -0.41. The grout take increases with Lu and SPI values, but there is no significant correlation between RQD and Js. The proposed approach for grouting design based on SPI values was verified through analysis and comparison with actual curtain-grouting construction, and is expected to be useful in practical applications and future studies.