• Title/Summary/Keyword: water need

Search Result 1,945, Processing Time 0.032 seconds

Study on Evaluation Method of Thermal Potential of Unused Energy (미활용에너지의 열 포텐셜 평가 수법에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Environmental Science International
    • /
    • v.15 no.5
    • /
    • pp.493-501
    • /
    • 2006
  • The increase in environmental loads and energy consumptions has resulted in the need of developed new forms of energy for a sustainable use for the society. Recently, the viability of using unused energy has attracted a great deal of attention. From the view point of using unused energy, the most critical problem can be referred to as the distance between the heat source/sink and heat demand area. The water resource in the city water system was used to solve this distance problem with unused energy. The calculation method of the potential use unit was used to survey the potential of the water resource in the city water system. The amount of theoretical unused energy and energy savings in the model city were estimated using this method. It is estimated that the amounts of energy savings and $CO_2$ reduction correspond to 131.3 GWh and 29280[t-C], respectively, per annual basis.

Influence of Pipe Materials and VBNC Cells on Culturable Bacteria in a Chlorinated Drinking Water Model System

  • Lee, Dong-Geun;Park, Seong-Joo;Kim, Sang-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1558-1562
    • /
    • 2007
  • To elucidate the influence of pipe materials on the VBNC (viable but nonculturable) state and bacterial numbers in drinking water, biofilm and effluent from stainless steel, galvanized iron, and polyvinyl chloride pipe wafers were analyzed. Although no HPC (heterotrophic plate count) was detected in the chlorinated influent of the model system, a DVC (direct viable count) still existed in the range between 3- and 4-log cells/ml. Significantly high numbers of HPC and DVC were found both in biofilm and in the effluent of the model system. The pipe material, exposure time, and the season were all relevant to the concentrations of VBNC and HPC bacteria detected. These findings indicate the importance of determining the number of VBNC cells and the type of pipe materials to estimate the HPC concentration in water distribution systems and thus the need of determining a DVC in evaluating disinfection efficiency.

Climate Data Qualification for Water Quality Impact Assessment (수질영향평가의 신뢰수준 향상을 위한 기상자료의 검정)

  • Lee, Khil-Ha;Cho, Hongyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.5
    • /
    • pp.601-613
    • /
    • 2011
  • This study is focused on a climate data integrity to improve water quality assessment due to the social development projects. The study is in an attempt to calculate both extreme ranges of weather data measurements and partly provide means to assess qualification of data which fall within the extremes at the 23 meteorological weather stations. Generally speaking, maximum temperature, minimum temperature, relative humidity, dew point temperature are in the range of reasonable accuracy. However, there found some outliers of the brightness sunshine hours in Cheonan station. Also some years in Gwangju, Seoul, Wonju, Busan, and Jeju never reach to their upper limit and perhaps the calibration of the equipment is doubtful. The users need to take cautions in using the brightness sunshine hour data in preparation of water resources planning and management by estimating evapotranspiration and river discharge, and/or growth rate of the algae (phytoplankton).

Sediment in Agricultural Reservoir and Variation of Storage (농업용 저수지의 토사퇴적과 내용적 변화)

  • Park, Jae-Heung;Jeon, Doh-Cheol;Kim, Jae-Jin
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.74-79
    • /
    • 2005
  • Many reservoirs have been constructed for sustainable utilization of water resources in Korea. Effective management of water resources in Korea becomes very important in resent years. Especially, the dredging in reservoirs is important for effective water resources management and one in easy water resources security methods. According to "The reservoir dredging mid-long term planning investigation report", it was investigated that 1221 reservoirs need to dredge among 3,288 reservoirs managed by KARICO. And, KARICO made a survey of reservoirs for the sediment and storage change in $2002{\sim}2004$. In results, it was investigated total storage $1,406{\pm}10^6m^3$, effective storage $1,344{\pm}10^6m^3$ in mid-small 2,748 reservoirs and the storage ratio decreased total storage ratio 15.7%, effective storage ratio 4.4%.

  • PDF

The TRS Terminal for Wireless Remote Corrosion Monitoring System (무선 원격 부식모니터링용 TRS 단말기)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.544-547
    • /
    • 2003
  • The owner of water pipeline has a burden of responsibility for the protection of corrosion and the prevention against leakage of water. So, they have been installed a CP(Cathodic Protection) System in odor to protect corrosion. And they also have been measured and analyzed the data about P/S(Pipe to Soil) potential of water pipeline. The P/S potential is basic data of evaluation for water pipeline corrosion. They need remote automatic corrosion monitoring system for easy maintenance. In this paper, The communication method was studied mainly. And the specifications of proposed TRS (Truncked Radio System ) terminal for corrosion monitoring are introduced briefly.

  • PDF

Estimation of irrigation water need using net water consumption concept in Jeju Island (순물소모량 개념에 의한 제주도 농업용수 수요량 산정)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.297-297
    • /
    • 2016
  • 유역 수자원 관리의 관점에서, 경작지에서 필요한 수량은 경작지에서의 작물생산을 극대화하기 위해 공급해야 할 수량으로 볼 수 있으며, 이는 작물 경작상태의 최대증발산량에서 경작이전상태의 실제증발산량을 감한 수량으로 추정할 수 있다. 즉, 작물 경작으로 인하여 증가된 물소모량을 순물소모량이라 정의하며, 우리나라에서는 1977년 낙동강유역 하구조사 기술보고서에서 처음 도입된 이후, 제3차 수자원장기종합계획(1991-2011), 21세기를 바라보는 수자원전망(1993), 수자원개발 가능 지점 및 광역배분계획 기본조사(1996) 등에서 유역규모의 수자원 부존량 해석, 수자원관리계획 수립을 위해서 유역 물수지 방법에 의한 순물소모량 개념의 접근방법이 적용되어 왔다. 본 연구에서는 제주도 지역에 순물소모량 개념을 적용하여 4개 시험유역(한천, 천미천, 강정천, 외도천) 및 제주도 전역에 대한 지역별 수요량을 산정하였다. 또한, 향후 예상되는 작물재배면적 변화에 따른 순물소모량의 변화를 검토하고, 기존 제주특별자치도 수자원관리종합계획(2013-2022)에서 제시하고 있는 필요수량 개념의 수요량과 비교하였다.

  • PDF

A Status of Agricultural Water Quality and Improvable Countermeasure in Korea (우리나라 농업용수 수질오염 현황과 개선대책)

  • Baeg, Cheong-Oh;Kang, Sang-Gu;Lee, Kwang-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.15 no.4
    • /
    • pp.506-519
    • /
    • 1996
  • The water quality in the rural areas is degrading due to a variety of causes such as the increase of the urban sewage and industrial wastes, the disposal of solid wastes, the growth of livestock waste, the growth of leisure facilities, the establishment of agricultural industry estates and etc. The water pollutants are scarce while the effluent is increasing from wide scattered sources. The technology specifically designed for the rural wastes water treatment plant needs to be implemented with improvement of agricultural water quality. 1. An integrated management measures against water pollution sources. The prevention of water pollution is the best measures in the environmental pollution. Hence, the most effective measures needs to be against the sources. Small-scale water treatment plants needs to be constructed in each village in the rural areas. As for the industrial effluent, the effluent discharge needs to be strictly monitored. Government subsidy for the establishment of treatment plant for livestock wastes is necessary. 2. The establishment of national-wide network for agricultural water quality. The network for agricultural water quality have been operated to conserve the agricultural water quality, and to develop management policies by the assessment of water pollution in the rural areas. The results of agricultural water quality network indicates that the water quality is degrading not only around urban areas but also in the distant rural areas, and the water quality at the pumping stations and weirs is worse than that of reservoirs. 3. The legal, systematic, and technical approaches for the agricultural water quality management. The actions currently implemented for the improvement of agricultural water quality involve temporary measures such as the improvement of irrigation facilities. These contingency measures are not effective in the long-term, and sometimes bring secondary pollution. Therefore, integrated measures covering the whole water environment such as the flow, quality, river morphology, aquatic ecosystem, and the surrounding environment, need be invented and implemented. Besides, the legal, systematic, and technical frameworks for the management are not fully established so far. The technology for the treatment of rural water pollution should be refined afterwards, and the research for the development of rural waste water treatment plant should be carried out.

  • PDF

Experimental Investigation of Horizontal Buoyant Discharges from a Rosette-type Riser Using LIF System

  • Kwon, Seok Jae;Seo, Il Won;Kim, Ho Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.463-467
    • /
    • 2004
  • Rosette-type diffusers with four-ports per riser are constructed in relatively shallow water in Korea. However, the trajectorial bending phenomena due to lower-pressure inside the surrounded buoyant jets on the riser was not considered in most models and was not observed without any experimental results. The buoyant jet behavior affected by the bending effect where there have been growing interests need to be verified experimentally and need to be preceded in the analysis of the characteristics of the buoyant jets oil a riser. The hydraulic model experiments have been carried out to investigate the characteristics of the behavior of horizontal buoyant jets discharged from a Rosette-type riser with four ports as well as single port over a certain range of the experimental conditions including initial momentum and initial buoyancy using LIF (Laser Induced Fluorescence) system to obtain concentration fields. The intensity of the fluorescent light in each pixel on the images obtained from LIF system with the tracer of Rhodamine H was converted to the local dye concentration with a set of calibration procedures to account for the non-uniform distribution of light intensity and the attenuation of light energy by water medium. The experimental results shows that the trajectories from Your ports tend to bend more and more to the inner side with the increase of the densimetric Froude number while the buoyant jet from a single port rises up without any bending phenomena. The previous models, VISJET and Seo et al. (2002), do not simulate the trajectories well except the region before the bending section. This study will focus on the analysis of the behavior of the buoyant jets for mainly a Rosette-type riser by conducting hydraulic model experiments using LIF system.

  • PDF

Long-term Trends of Summer Season of Water Quality in Lake Doam (도암호에서 하절기 수질의 장기적인 경향)

  • Kwak, Sungjin;Bhattrai, Bal Dev;Lee, Changkeun;Heo, Woomyung
    • Korean Journal of Ecology and Environment
    • /
    • v.46 no.1
    • /
    • pp.128-134
    • /
    • 2013
  • In the summer season (June~August) during the study period of Lake Doam, average concentrations of major water quality parameters, COD, SS, TN, and TP were 4.0, 16.2, 3.129 and $0.077mg\;L^{-1}$, respectively, and Chl-a was $11.8mg\;m^{-3}$. The result has indicated that Lake Doam was a meso-eutrotrophic lake. Lake Doam data from the summer season (June~August), precipitation from 2001 to 2012, and water quality (COD, SS, TN, TP, Chl-a etc.) of seven years (2001, 2002, 2004 and 2009~2012), were statistically analyzed for long-term trends by Mann-Kendall test and Sen's slope estimator methods. The statistical results showed that precipitation, SD, COD, TN, $NO_3-N$, $NH_3-N$ and Chl-a had decreasing trends, and EC, turbidity, SS, TP and DIP had increasing trends. Suspended solids and total phosphorus were directly affected by precipitation. In the case of suspended solids, more aggressive and constructive plans need to be implemented than the current turbidity reduction project to achieve the targeted water quality ($5mg\;L^{-1}$ of SS) in Lake Doam. In particular, we need to specify a project that considers the steep topographic characteristics of high, land farming areas and precipitation conditions of the Lake Doam watershed, which can increase the efficiency of a turbidity reduction project.

A Study on the Energy and Water Consumption and their Patterns as Vertical Locations of Apartment Housing Units (아파트 단위 세대의 수직 위치 별 에너지 및 물 사용 규모와 패턴에 관한 연구)

  • Song, Dong-Hun;Kim, Kyung-Tae;Lee, Seung-Jun;Shin, Hyun-Ik
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.53-63
    • /
    • 2017
  • The purpose of this study is to present an integrated analysis for energy use and its patterns as vertical locations of the dwelling units in apartment buildings which are located in an urban area and constructed by a renowned contractor. In order to enhance the effectiveness of the method, the original data of electricity, water, and gas bills which directly reflect the energy use are sorted and analyzed into several groups as vertical locations in each building. And also, by use of comparing and contrasting the data on a monthly and yearly basis, the accuracy of analyses for seasonal energy use and its patterns is strengthened. Comparative analyses used in this study describe the results that vertical locations of dwelling units do not have much influence on electricity and water usage, but are closely related with gas usage for a heating season. According to the analysis of gas usage, the units on the ground and right above pilotis need enhancement in the insulations for heating to mitigate energy loss. Also, the analysis for the middle floor units in each group describe the fact that the gas usage of the units on the ground is consumes 1.5 times greater than that of the typical floors. Therefore, enhanced insulation strategies need to be considered against the adverse condition that the heat loss increases as the wall facing the outside air increases or as the wind velocity increases through the pilotis.