• 제목/요약/키워드: water main

검색결과 4,613건 처리시간 0.035초

상수관망의 자가세척 유속과 적정 플러싱 유속 평가 (The assessment of self cleaning velocity and optimal flushing velocity in water distribution system)

  • 배철호;최두용;김주환;김도환
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.441-451
    • /
    • 2014
  • The flushing is important to maintain good water quality in water main. It is a technique of using water velocity to remove sediments in water distribution system. The variety of water quality problems can occur in a distribution system, so too can a variety of benefits be gained by system flushing. In order to effectively perform the flushing, the contaminants to be removed to set up and it can be solved, it is necessary to ensure the proper flow rate. In this study, the removal of contaminants present in the inner water pipe attached loose deposits such as fine particles of granular activated carbon, sand and iron corrosion product sought to derive flow rates. Thus, the constant observation of using pilot plant scale water distribution plant for the movement of floating characteristics of particles were assessed.

정수처리공정의 THMs 생성과 농도변화에 관한 연구 (A Study on Formation and Concentration of Trihalomethanes in Water Treatment Process)

  • 조덕희;안승구
    • 한국환경보건학회지
    • /
    • 제23권2호
    • /
    • pp.28-34
    • /
    • 1997
  • This study was carried out to investigate the effects of prechlorination and algae growth on THMs generation. The sample water obtained from Paldang Dam which is a main source of raw water for the Seoul metropolitan area. THMs concentration in the sample water was investigated in water treatment process prechlorifiation, chemical coagulation, and sand filtration. And also, THMs concentration were analyzed in the water which cultured algae in laboratory. The results were as follows 1. The THMs concentration produced by prechlorination unit process were increased in control (not purified) but decreased in process of purification. 2. The THMs concertration can reduce by increasing the number of cleaning filters. 3. The main precursor in raw water for the THMs generation was supplied by algae growth. So as to reduce the THMs concentration in water supplying system, it is the best method to manage algae growth in water body of Paldang reservoir.

  • PDF

광주광역시 하천수의 수질 및 오염 (Water Quality and Pollutions of River waters in Gwangju City)

  • 오강호;고영구
    • 한국환경과학회지
    • /
    • 제12권3호
    • /
    • pp.287-297
    • /
    • 2003
  • To investigate water quality and pollution states of rivers in Gwangju city, total of 30 water samples were taken from the main stream of Yeongsan river, Hwangryong river and Gwangju stream in dry and flood seasons. Physico-chemical characteristics of above streams according to pH-Eh and Piper's diagrams we, typically, assigned to natural river water. In the streams, BOD, COD, T-N and T-P indicating water quality mostly increase toward downstream. Notably, water qualities in area near connection between the Gwangju stream and the main stream of Yeongsan river are polluted over V level in rivers and lakes water quality standard. The pollutions are influenced by lift and agricultural foul waters from Gwangju City and farming areas around upstream branches of the Yeongsan river, reasonably. Besides, heavy metals are below the standard in those streams. So, it is considered that the streams are polluted by not industrial but life/agricultural foul waters.

제주도 어승생 저수지 색도 원인 분석 (Analysis of chromaticity cause in Jeju Eoseungsaeng Lake)

  • 이정훈;이희남;김진근
    • 상하수도학회지
    • /
    • 제30권4호
    • /
    • pp.381-389
    • /
    • 2016
  • Jeju Eoseungsaeng lake which is a main water resource of Eoseungsaeng water treatment plant($Q=15,000m^3/d$) experienced high chromaticity(40 CU) and pH(9.46) in 2013. This could decline customer's confidence on drinking water quality unless proper identification and removal of chromaticity were implemented. To find cause of chromaticity, water monitoring on various water parameters including TOC, algal cell count, Chl-a, turbidity, SS, conductivity, etc. were implemented. Iron and manganese were excluded from the cause of chromaticity due to its low concentration (i.e., < 0.02 mg/L). Correlation among water parameters showed that relationship between algal cell count and chromaticity was the highest(R=0.43), which suggested that presumably the main reason of chromaticity occurrence in Jeju Eoseungsaeng lake was algae.

수변계획을 위한 계절별 수질오염 분석 (Analyses of Seasonal Water Quality Pollution for Side Planning)

  • 이양규;한중근;홍창선
    • 상하수도학회지
    • /
    • 제20권3호
    • /
    • pp.347-355
    • /
    • 2006
  • Anyang Stream including its main branch is the biggest branch stream of Han River in Korea. The geological and geomorphological characteristics were investigated to the affected area of Anyang Stream, in which rainfall characteristic was analyzed. The water quality surveyed that the analysis of water pollution used to biotic index and biological water pollution. The rainfall pattern in this area was like to that of typical Korea, but the rate of trigger and runoff during summer season(June~August) is more higher than mean of Korea. Before 2003, a dried stream is severe status, which was due to abundant runoff, but this status are improved. After 1997, water quality of stream is recovering status such as water pollution of stream steeply decreased. Especially after 2003, this trend is more quickly improved. Although, owing to the increasing of a T-N and SS at upstream wastewater were due to bad collection of industrial factories, livestock's and mans living, the water quality worsted at upstream. Water quality in total section of main stream was severely contaminated that water-quality limit is 5 with polysaprobic by water self-purification. That of main branch was 1~3limits with ${\alpha}$- and ${\beta}$-mesosaprobic in Anyang city area, But water quality in all area about another branch of Anyang stream except Anyang city area was almost under of 3 grades. Though trying of Anyang city for recover movement(completion of 2nd Sewage Treatment Plant and Water supply pipe system) on Anyang stream, water pollution states of upper branch in Anyang stream was not better than its of 2002 because it may be difference of control area on other cities.

하나로 핵연료 시험장치의 주냉각수 계통 상온기능시험 (The Cold Function Test of a Main Cooling Water System for a Nuclear Fuel Test Loop Installed in HANARO)

  • 박용철;이용섭;지대영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2505-2510
    • /
    • 2008
  • A nuclear fuel test loop (after below, FTL) is installed in IR1 of an irradiation hole in HANARO for testing neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. When HANARO is normally operated, the fuel loaded in the irradiation hole has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain an operation condition of the test fuel, a main cooling water system (MCWS) is installed in the OPS of the FTL. This paper describes the cold function test results of the MCWS. It was confirmed through the test results that the system met the design requirements under a cold operation condition.

  • PDF

Memtrane SEparation of Activated Sludge for Waste Water Treatment and Water Recycle

  • Miyano, O-Tadadki;Yohgi Inoue;Toyozo Hamada;Shuji Nakatsuka
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 Energy Saving Membrane Separtion Systems 에너지 절약형 막분리 시스템
    • /
    • pp.39-39
    • /
    • 1999
  • Membrane separation technology has become a more attractive technology on waste water treatment and water recycle in recent years. On this application, membrane does not take main part of treatment, such as decomposition or handling of organic matter in the waste water, but it is very important supporting method in the total system. Activated sludge is most popular method as main part. In the system , membrane works as a separator to obtain clear water after biological treatment, by which the permeate could be released, recycled or applied to further additional treatment, instead of conventional sedimentation, coagulation and sand filtration. We would like to introduce our system cases for waste water treatment and water recycle, in which membrane separation technology works. In most of cases, membranes are applied to solid- liquid separation of activated sludge. Our experiences will be introduced as following items.

  • PDF

Institutional Improvement of Irrigation Management System in Korea

  • Chung, Sang-Ok
    • 한국농공학회지
    • /
    • 제44권7호
    • /
    • pp.74-82
    • /
    • 2002
  • There are two major operation and management (O & M) systems in Korea, one by the Korea Agricultural and Rural Infrastructure Corporation (KARICO), a government corporation, and the other by non-KARICO, which includes Irrigation associations (IAs) and individual farmers under the supervision of city or county authorities. Main issues and constraints in the irrigation facility management are: (1) The dual system of the irrigation water management system; management by KARICO and that by IAs, and (2) From the commencement of KAICO in 2000, farmers were exempted from water charge. This is opposite to the international trend, which follows' user pay principle: Main specific strategies to improve irrigation management system are: (1) Introduction of water metering for water charge as well as water conservation, (2) Adoption of demand-oriented irrigation rather than supply-oriented to reduce waste of water, (3) To augment farmer's participation by forming water user associations, (4) To maintain consistency of government policy, (5) To promote roles of local governments, and (6) To reestablish the role of KARICO.