• Title/Summary/Keyword: water intake

Search Result 1,546, Processing Time 0.034 seconds

An Experimental Study on the characteristic of Exhaust Emissions and the Engine Performacne with Intake Port Water Injection in Diesel Engine (흡기 포트 내 물 분사에 의한 디젤 기관의 배기 유해물 배출 및 기관 성능 변화에 관한 실험적연구)

  • 김기형
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.25-32
    • /
    • 1999
  • This study was carried out to reduce NOx emissions from diesel engine and to investigate the variation of engine performance using the water injection. In this study the water was extracted from the exhaust gas and injected directly into the intake port with the inlet charge. The water condensing system operated as a closed system without any supplementary water supply. The experimental parameters such as the revolution the torque and the water injection rate are varied and the result from this experiment found the significant NOx reduction whereas the smoke emission increases as water/air ratio increases as the cases like the EGR. In spite of increasing the quantity of the water injection the engine output was slightly decreased and the specific fuel consumption was increased as was anticipated. Especially the system was founded to be effective on the reduction of the NOx emissions at the high load region relatively.

  • PDF

The Role of Neuropeptide Y in the Central Regulation of Grass Intake in Sheep

  • Sunagawa, K.;Weisiger, R.S.;McKinley, M.J.;Purcell, B.S.;Thomson, C.;Burns, P.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.1
    • /
    • pp.35-40
    • /
    • 2001
  • The physiological role of brain neuropeptide Y (NPY) in the central regulation of grass intake in sheep was investigated through a continuous intracerebroventricular (ICV) infusion of NPY at a dose of $5{\mu}g/0.2ml/hr$ for 98.5 hours from day 1 to day 5. Sheep (n=5) were fed for 2 hours once a day, and water and 0.5 M NaCl solution were given ad libitum. Feed intake during ICV NPY infusion increased significantly compared to that during ICV artificial cerebrospinal fluid (CSF) infusion. Water and NaCl intake during ICV NPY infusion remained unchanged. Mean arterial blood pressure (MAP) and plasma osmolality during ICV NPY infusion were not significantly different from those during ICV CSF infusion. On the other hand, plasma glucose concentration during ICV NPY infusion increased significantly compared to that during ICV CSF infusion. The results suggest that brain NPY acts as a hunger factor in brain mechanisms controlling feeding to increase grass intake in sheep.

Seismic risk assessment of intake tower in Korea using updated fragility by Bayesian inference

  • Alam, Jahangir;Kim, Dookie;Choi, Byounghan
    • Structural Engineering and Mechanics
    • /
    • v.69 no.3
    • /
    • pp.317-326
    • /
    • 2019
  • This research aims to assess the tight seismic risk curve of the intake tower at Geumgwang reservoir by considering the recorded historical earthquake data in the Korean Peninsula. The seismic fragility, a significant part of risk assessment, is updated by using Bayesian inference to consider the uncertainties and computational efficiency. The reservoir is one of the largest reservoirs in Korea for the supply of agricultural water. The intake tower controls the release of water from the reservoir. The seismic risk assessment of the intake tower plays an important role in the risk management of the reservoir. Site-specific seismic hazard is computed based on the four different seismic source maps of Korea. Probabilistic Seismic Hazard Analysis (PSHA) method is used to estimate the annual exceedance rate of hazard for corresponding Peak Ground Acceleration (PGA). Hazard deaggregation is shown at two customary hazard levels. Multiple dynamic analyses and a nonlinear static pushover analysis are performed for deriving fragility parameters. Thereafter, Bayesian inference with Markov Chain Monte Carlo (MCMC) is used to update the fragility parameters by integrating the results of the analyses. This study proves to reduce the uncertainties associated with fragility and risk curve, and to increase significant statistical and computational efficiency. The range of seismic risk curve of the intake tower is extracted for the reservoir site by considering four different source models and updated fragility function, which can be effectively used for the risk management and mitigation of reservoir.

Estimating Freshwater Fish Intake for Human Health Risk Assessment Using Korea National Health and Nutrition Examination Survey (국민건강영양조사를 활용한 담수어패류 섭취량 산정: 위해성 평가를 위한 파라메타 도출)

  • Kwak, Jin Il;Oh, Kyungwon;Kweon, Sanghui;An, Youn-Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.2
    • /
    • pp.165-169
    • /
    • 2013
  • Freshwater fish intake is a critical parameter for deriving water quality criteria and water quality standards for protection of human health based on human health risk assessment. Although the freshwater fish intake parameter should be accurate and representative of Korean fish consumption for the water quality criteria to be reliable, data are limited in Korea and have low reliability. In this study, Korean National Health and Nutrition Examination Survey data from 2008-2010 were analyzed to reevaluate freshwater fish consumption. Based on these results, an average consumption rate of 3.0 g/day per person, a $90^{th}$ percentile consumption rate of 0.0 g/day per person, an average consumption rate of 65.7 g/day per fish consumer, and a $90^{th}$ percentile consumption rate of 153.4 g/day per fish consumer were proposed for derivation of water quality criteria using a conservative approach and various exposure scenarios.

Influence of Panax Ginseng upon Water and Food Intake in Rats (인삼이 흰쥐의 물 및 먹이 섭취에 미치는 영향)

  • Chung, Hyung-Keun;Choi, Soo-Hyun;Suh, Chung-Min
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.21-23
    • /
    • 1973
  • To see if the Panax Ginseng has any influence upon the amount of water and food intake, an experiment was carried out using 30 male rats. The animals were divided equally into the ginseng and the saline groups. For 5 days, animals belonging to the ginseng group received every day 0.5 ml/100g body weight of ginseng extract (4 mg of ginseng alcohol extract in 1 ml of saline), while animals belonging to the saline group received the same amount of saline. After the last medication on the 5th day, each animal was accommodated in a cage which was provided with a food well and a water supplier made of glass tube bent $30^{\circ}$ at the tip. The amounts of water and food consumed in the daytime (from 6 a.m. to 6 p.m.) and at night (from 6 p.m. to 6 a.m. next morning) were measured for 2 days. The ginseng group tended to consume water and food slightly more than the saline group did. However, the difference between the 2 group was far from reaching significancy. The influence of Panax Ginseng upon water and food intake was not evident.

  • PDF

Liquid Intake of Female High School Students by Self-Recording Method for 3-days in Daejeon (3일간의 자기 기입식 기록법을 적용한 대전지역 여고생의 액체수분 섭취실태)

  • Kim, Young Ah;Kim, Youngnam
    • Journal of Korean Home Economics Education Association
    • /
    • v.30 no.4
    • /
    • pp.83-91
    • /
    • 2018
  • This study was performed to measure the liquid intake and the liquid intake difference by obesity, exercise frequency, and salty food intake score in female high school students. A total of 235 students in Daejeon area were participated, and the liquid intake was recorded for 3-days(2 weekdays and 1 weekend) by self-recording. The T-test, F-test, Pearson's correlation, and Scheffe test were exercised. The results of this study are as follows. The amount of total liquid intake was 838.5 ㎖/d. Among the 13 kinds of beverages, water was the highest 611.6 ㎖/d, 72.9% of liquid intake total, followed by carbonated drink(65.7 ㎖/d), milk(41.6 ㎖/d), fruit drink(32.8 ㎖/d), and fruit·vegetable juice(25.4 ㎖/d). The other beverages' intake were very small, ≤13.0 ㎖/d. Carbonated drink, milk, and coffee's intake were higher during weekend than weekday. There were sig. difference in water and total liquid intake by the obesity, student of BMI≥23.0 was higher than students of BMI<23.0. And only carbonated drink was sig. different by exercise frequency and salty food intake score. Exercise frequency of ≥3 d/week and salty food intake score of ≥7(very dangerous) consumed more carbonated drink than the lower counterparts. Total liquid intake of female high school students was not reach to 900 ㎖/d, the Adequate Intake in Dietary Reference Intake for Koreans 2015. The amount of milk intake was 41.6 ㎖/d, far less than the Recommended Intake of 2 serving, 400 ㎖/d. Education and promotion program may necessary to increase the liquid intake amount and to choose the nutritious beverage.

Effect of Water Induction on the Performance and Exhaust Emissions in a Diesel Engine (II)

  • Ryu, Kyunghyun;Oh, Youngtaig
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.9
    • /
    • pp.1640-1647
    • /
    • 2004
  • This study was to investigate the effects of water induction through the air intake system on the characteristics of combustion and exhaust emissions in an IDI diesel engine. The fuel injection timing was also controlled to investigate a method for the simultaneous reduction of smoke and NOx when water was injected into the combustion chamber. The formation of NOx was significantly suppressed by decreasing the gas peak temperature during the initial combustion process because the water played a role as a heat sink during evaporating in the combustion chamber, while the smoke was slightly increased with increased water amount. Also, NOx emission was significantly decreased with increase in water amount. A simultaneous reduction in smoke and NOx emissions was obtained when water was injected into the combustion chamber by retarding more 2$^{\circ}C$A of the fuel injection timing than without water injection.

Analysis of Seawater Intake System using the RNG k-𝜖 Algorithm (RNG k-𝜖 알고리즘을 이용한 해수취수시스템 분석)

  • Kim, Ji-Ho;Kim, Tae-Won;Lee, Seung-Oh;Park, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6447-6454
    • /
    • 2013
  • Seawater intake systems have significant problems due to seawater pollution, suspended solids, unstable intake and maintenance etc. An underground type seawater intake system was newly developed to overcome the existing weaknesses and was facilitated in Gyukpo port. In this study, to check the performance of the new system, the samples for water quality and the 3-D numerical modeling test were conducted. The five times test included the COD, total nitrogen, total phosphorus, pH, and suspended solid for the intake system. The analyses show that the COD, total nitrogen, total phosphorus, PH showedminor changes before and after. On the other hand, the change in suspended solids was significant and water was purified below 5 mg/l, first level fisheries water, after. The numerical model adopted the RNG $k-{\epsilon}$ algorithm and the CFX model based on the finite volume method. The porosity algorithm was used to reproduce filtered-sand, outer diameter, and thickness. The numerical results showed that the double pipe is advantageous in that it provides a uniform pressure between the inner and outer pipe for the flow to be stable. In addition, the use of multiple intake pipes did not interfere with the discharge reduction of 0.98 at the both intake pipes compared with the central intake pipe.

A study on the flow characteristics around a suction pipe of circulation water pump in thermal power plant (화력발전소 순환수펌프 흡입관 주위에서의 유동특성에 관한 연구)

  • Choi, Sung-Tyong;Ahn, Jung-Hyeon;Moon, Seung-Jae;Lee, Jae-Heon;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.201-204
    • /
    • 2008
  • Vortex and swirl occurring in a pump suction intake sump normally reduce the performance and disturb the safe operation of the circulation water pump in thermal power plants. This paper presents a case study of one particular intake sump design via a CFD analysis and a hydraulic model testing. The physical experiments and numerical analysis were performed under two flow and three level variation conditions. The vortex patterns around the pump suction pipe have been predicted by a commercial CFD code with the k-${\varepsilon}$ model. The model tests were conducted on a 1/10 model for a practical intake sump. The location, number and general pattern of the free surface vortex and submerged vortex predicted by CFD simulation were found to be a good agreement with those observed in the model testing.

  • PDF

Modifications to Hydraulic Structures for Anti-submerged Vortex in a Multi Pump Intake using CFD simulation Technique (수리구조 개선을 통한 다중 펌프 흡수정에서 발생하는 보텍스 방지 대책 수립에 관한 연구)

  • Park, No-Suk;Kim, Seong-Su;Jeong, Woo-Chang;Kim, Jong-Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.31-39
    • /
    • 2011
  • In order to suggest the methodology for achieving anti-vortex device within multi pump intake well, CFD(Computational Fluid Dynamics) simulation were conducted for two alternative suggestions. Multi-intake sump model with anti-vortex device basins were designed and the characteristics of submerged vortex were investigated in the flow field by numerical simulation. From the results of simulations, to install the horizontal plate and vertical cross plates within basins were effective for preventing air-induction vortex.