• Title/Summary/Keyword: water influx rate

Search Result 32, Processing Time 0.029 seconds

A Study on the Water Circulation Enhancement inside Harbor Utilizing Wave Energy (파랑에너지를 이용한 항내 해수순환증진에 대한 연구)

  • 오병철;전인식;정태성;이달수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.3
    • /
    • pp.209-221
    • /
    • 2002
  • In the present paper, a method which enhances the circulation of harbor waters by using wave energy was investigated. The overflow levee was selected as a coastal structure helping the harbor circulation, and was applied to Jeju-outer-port site so as to estimate its effectiveness quantitatively in probabilistic point of view. It was assumed that sea water influx rate through the overflow levee into the harbor depended upon wave height and tidal level and a functional relationship among them was calculated using the results of hydraulic experiment. The probability distribution of water influx could be obtained from hindcasted wave data and measured tidal elevations at Jeju harbor. The Gamma distribution was appeared to best fit the estimated influx distribution, and the optimal location of the levee was discussed. Finally, water quality purification effect was investigated by computing the contaminant material dispersion according to whether the levee was or not.

Evaluation of Pollutant loads at Inflow Streams under Ara Waterway Basin

  • Han, Sangyun;Jung, Jongtai
    • Journal of Urban Science
    • /
    • v.10 no.1
    • /
    • pp.39-48
    • /
    • 2021
  • In this study, to evaluate the characteristics of the pollution in the major inflow tributaries and major environmental facilities in the watershed of Ara waterway, An inflow flow rate measurement and water quality analysis were conducted during dry and rainy seasons. In addition, the flow rate measurement, water quality analysis, and pollutant load at each monitoring point were compared and evaluated. Influx of BOD5, T-P and T-N into the tributaries of the ARA waterway watershed, excluding the Gulpo river watershed, during dry season were only 0.007%, 0.005% and 0.004% respectively of the incoming loads in the entire ARA waterway basin. In addition, it was confirmed that the discharge pollutant loads during rainfall event was about 440 times more for BOD5, about 545 times on T-P, and about 23 times on T-N in comparison to the pollutant loads during the dry days. When the Gulhyeon rubber dam was deflated, the discharged pollutant load during a rainfall was higher than the estimated load at the G7 monitoring point because the deposited pollutants from the upstream riverbed flowed down. Therefore, during a rainy season, it is necessary to manage the influx of high-load water pollutants from the overflow and deflation of the Gulhyun rubber dam as well as to find a strategy to reduce the pollutant loads in the Gulpo river watershed.

Tracing Water Pollution Source using FDC and Exceedance Rate in Cheongmicheon Watershed (FDC 및 초과율을 이용한 청미천 유역에서의 오염원 추적)

  • Kim, Yeon-Su;Kim, Sang-Ho;Lee, Chang-Hee
    • Journal of Wetlands Research
    • /
    • v.20 no.2
    • /
    • pp.136-144
    • /
    • 2018
  • The Ministry of the Environment conducts a water environment management plan and TMDL(Total Maximum Daily Load) for integrated watershed management, and determines whether the target water quality is achieved using water quality monitoring data. The concentration of monitoring points located in the downstream of the watershed is the outcome of complicated mechanisms such as influx of pollutants from the tributaries of the watershed and self-purification of river water. The purpose of this study is to analyze the effect of main stream and tributary water quality on the target water quality point using the water pollution source tracking and exceedance rate of watershed. In this study, FDC and exceedance rate analysis were performed on six water quality items including BOD and T-P, which are the targets of TMDL. Water quality items and points affecting the target water quality point were derived from flow rate. In this study, the pollution source tracking through FDC analysis and exceedance rate analysis will be able to establish more efficiently the water quality management strategy for each branch to achieve the target water quality.

Water Quality Characteristics of the Major Tributaries in Yeongsan and Sumjin River Basin using Statistical Analysis (통계분석을 이용한 영산강·섬진강수계 주요 유입지천의 수질 특성)

  • Park, Jinhwan;Jung, Jaewoon;Kim, Daeyoung;Kim, Kapsoon;Han, Sungwook;Kim, Hyunook;Lim, Byungjin
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.2
    • /
    • pp.171-181
    • /
    • 2013
  • In this study, we report the water quality characteristics of pollutants for 4 major tributaries in the Yeongsan and Sumjin river basins using statistical analysis, such as regression equation and factor analysis. The flow rate and water qualtiy data collected from 4 sampling sites(Hwangryoung A, Jiseok A, Chooryeong A, Osu A) in the Yeonsan and Sumjin river basin during the past 3 years were analyzed for 11 parameters(flow rate, dissolved oxgen, pH, water temperature, electric conductivity, biochemical oxygen demand, chemical oxygen deman, total organic carbon, total nitorgen, total phosphorus, suspended solid). The results showed that the concentrations of BOD, COD, TOC, T-N, T-P in Hwangryoung A(HW) and Jiseok A(JS) of the Yeongsan river basin were decreased as the flow rate was increased. This means that rather than nonpoint soources, point sources affect water quality. In the cases of Chooryeong A(CR) and Osu A(OS) in the Sumjin river basin, howerever, nonpoint sources than point sources are an important factor that affects the water quality. Also, the factor analysis technique was employed to analyze principal component influencing on water quality. The results revealed that the first principal component in HW was correlated with EC, DO, T-N, water temperature. This "nitrogen influx according to seasonal pattern" factor may be interpreted. In JS, the first principal component was correlated with BOD, COD, TOC and is likely to represent "organic matter" processes. In CR and OS, BOD, COD, TOC, SS and T-P were significantly correlated and is considered as representing "Organic matter and adsorption of phosphorus on sediments influx". This study is expected to contribute to the effective pollution control/management of the surfac waters in the study sites.

Effects of Salinity, Temperature and Food Type on the Uptake and Elimination Rates of Cd, Cr, and Zn in the Asiatic Clam Corbicula fluminea

  • Lee, Jung-Suk;Lee, Byeong-Gweon
    • Ocean Science Journal
    • /
    • v.40 no.2
    • /
    • pp.79-89
    • /
    • 2005
  • Laboratory radiotracer experiments were conducted to determine assimilation efficiencies (AE) from ingested algal food and oxic sediment particles, uptake rates from the dissolved phase, and the efflux rates of Cd, Cr and Zn in the Asiatic clam Corbicula fluminea. Among three elements, AE from both algal and sediment food was greatest for Cd, followed by Zn and Cr. The AEs of tested elements from algal food (Phaeodactylum tricornutum) were consistently higher than those from sediments at a given salinity and temperature. The influence of salinity (0, 4 and 8 psu) and temperature (5, 13 and $21^{\circ}C$) on the metal AEs was not evident for most tested elements, except Cd AEs from sediment. The rate constant of metal uptake from the dissolved phase $(k_u)$ was greatest for Cd, followed by Zn and Cr in freshwater media. However, in saline water, the $(k_u)$ of Zn were greater than those of Cd. The influx rate of all tested metals increased with temperature. The efflux rate constant was greatest for Cr $(0.02\;d^{-1})$, followed by Zn $(0.010{\sim}0.017\;d^{-1})$ and $Cd\;(0.006\;d^{-1})$. The efflux rate constant for Zn in clam tissues depurated in 0 psu $(0.017\;d^{-1})$ was faster than that in 8 psu $(0.010\;d^{-1})$. Overall results showed that the variation of salinity and temperature in estuarine systems can considerably influence the metal bioaccumulation potential in the estuarine clam C. fluminea. The relatively high Cd accumulation capacity of C. fluminea characterized by the high AE, high dissolved influx rate and low efflux rate, suggested that this clam species can be used as an efficient biomonitor for the Cd contamination in freshwater and estuarine environments.

A Study on Adsorption Characteristics of the Heavy Metals using Melting Slag of Incinerator Ash (소각재 용융슬래그를 이용한 중금속 흡착특성에 관한 연구)

  • Yoo, Seung-Chol;Kim, Hwan-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.413-420
    • /
    • 2008
  • In order to utilize cinder melting slag as a filter media to control the quality of early rainwater, its environmental stability was verified by heavy metal elution experiment and improved by pre-treatment. Possibilities of improving its function as an absorbent was considered. Absorption characteristics of melting slag before and after the pre-treatment were analyzed by heavy metal equilibrium and stationary-phase column experiments, which in turn were analyzed by comparison experiment with activated carbon. As a result of heavy metal elution experiment, every metal item existed in a much lower amount than the criteria or was not detected, implying that there is no problem recycling it. Absorption equilibrium experiment showed that the time for pre-treatment melting slag to reach the equilibrium was reduced, while the absorbed amount was greatly increased. Stationary-phase column experiment assures us that the elimination rate was not changed much by influx rate, pH and the change in packing volume rate, indicating that this melting slag can be used not only as a filter media to control the quality of early rainwater but also in many areas of water-processing.

The Effects of Changing of Hydraulic Retention Time and Charging Media on the Removal of Nitrogen and Phosphorus in the Up-flow Anaerobic/Anoxic Reactor and Water-mill for Sewage Treatment (상향류식 혐기성조, 무산소조 및 수차호기조를 이용한 하수처리시 수리학적 체류시간의 변화와 메디아 충진이 질소 및 인 제거에 미치는 영향)

  • Shin, Myoung-Chul;Lee, Young-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.1
    • /
    • pp.64-70
    • /
    • 2009
  • The aims of this study is to examine the effects of the changes in HRT(Hydraulic Retention Time) and media charge in a water-mill, among other operation factors, on the nitrogen and phosphorus removal in order to use up-flow anaerobic reactors, anoxic reactors and water-mill aerobic reactors for sewage treatment. The extension of HRT improved the nitrogen removal efficiency, however the removal pattern was constant regardless of HRT. The removal of phosphorus was constant (80%-90%) regardless of the change in HRT. The removal rate with change in influx load varied such that at the OLR (Organic Load Rate) of 1-3 kg/d, the T-N removal efficiency was 80.7%-88.9% and the T-P removal efficiency was 82.9%-89.3% while at the NLR (Nitrogen Loading Rate) of 0.108-0.156 kg/d the removal efficiencies were 80.7-88.9% (T-N) and 82.9-89.3% (T-P). The analyses of the nitrogen and phosphorous removal characteristics with the C/N and C/P ratio showed that the mean T-N removal rate was 88% at the C/N ratio of 1.2-2.6, and that the mean T-P removal rate was 86% at the C/P ratio of 7.2-14.1. Also, the analysis of nitrogen and phosphorous removal characteristics were analyzed in relation to media charge. The comparison between with and without media charge in the water-mill showed that while the nitrogen removal efficiencies were 86-94% and 85-89% respectively, the difference of phosphorous removal efficiencies were between the two conditions was not significant, thus it suggested that the media charge has less effect on the removal efficiency of phosphorous compared to that of nitrogen.

Variation of Corrosion Properties on the Steel Surface by Environmental Changes in Shihwa Lake (시화호 환경 변화에 따른 강재 표면의 부식특성 변화)

  • Park, Jun-Mu;Lee, Seung-Hyo;Woo, Sang-Kyun;Chu, In-Yeop;Lee, Myeong-Hoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.5
    • /
    • pp.316-324
    • /
    • 2018
  • Harsh seawater environment is subdivided into marine atmosphere, splash zone, tidal zone, submerged zone and bottom of sea depending on the exposed part. Since corrosion rate depends on the conditions of the exposed parts, proper protection and maintenance for each parts are essential for long-term use of steel structures in seawater environment. For steel structures which were installed in Shiwha Lake, a special maintenance system is required to guarantee its long-term durability and safety. As the tidal power plant has recently been operated, the salinity has risen due to the rapid influx of seawater upstream into Sihwa Lake and the corrosion tendency of the structure is variable according to the water level fluctuation. In this study, corrosion properties of steel structures under water level fluctuation was evaluated by corrosion rate measurement, visual inspection and natural potential measurement and their durability and life management were discussed in view of the effect of variation in of seawater level fluctuations in Shihwa Lake.

An Evaluation of Cooling of Core Debris and Impact on Containment Transient Pressure under Severe Accident Conditions (극심한 사고시 노심 냉각 및 격납용기 과도압력에 미치는 영향)

  • Jong In Lee;Jin Soo Kim;Byung Hun Lee
    • Nuclear Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.256-266
    • /
    • 1983
  • An evaluation of containment transient pressure due to the particulate debris/water/concrete interaction under severe accident conditions is presented for a pressurized water reactor with a large dry containment building. A particulate debris/water/concrete model is developed and incorporated into the MARCH computer code. Comparisons with the existing MARCH molten debris/concrete model were performed for the TMLB' and S$_2$D sequences. The results yield a much slower concrete decomposition rate and release less gases into the containment atmosphere. Contrary to the molten debris model, the particulate debris model exhibits a strong interaction with water and causes a higher containment pressure. The effect of gas influx on the debris bed heat transfer was found to be insignificant.

  • PDF

Influence of Soil Texture and Bulk Density on Root Growth Characteristics and Nutrient Influx Rate of Soybean Plant (토성(土性)과 용적밀도(容積密度)가 대두(大豆)의 뿌리 생장특성(生長特性)과 양분흡수기능(養分吸收機能)에 미치는 영향(影響))

  • Jung, Yeong-Sang;Lim, Hyung-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.22 no.3
    • /
    • pp.221-227
    • /
    • 1989
  • This study was conducted to understand the influence of soil compaction on root growth and nutrient uptake characteristics of the soybean roots grown in two soils with different texture. Tap root elongation was measured on young seedling grown in cores compacted to different bulk densities of 1.2, 1.4 and $1.6/cm^3$ with different soil water retention in laboratory. The soil used were Samgag sandy loam and Baegsan loam soils. The wet and dry weight, total length, average radius and total surface area of roots were measured on soybean plants grown in 1/5000 a Wagner pots compacted to different bulk density of 1.2 and $1.4g/cm^3$. The nutrient uptake of soybean shoot was measured and evaluated with the unit surface area of roots at the 7th, 17th and 27th days after germination. The results were as follows: 1. The tap root elongation rate was faster in the loam soil with low bulk density than in the sandy loam soil with high bulk density. The elongation rates were remarkedly decreased when soil water was lower than the retention of 4 bars in loam soil and that of 1 bars in sandy loam soil. 2. Tap root elongation rate sharply decreased as increased soil strength higher than $2kgf/cm^2$ measured by ELE penetrometer showing curvillinear regression. However, it was low regardless of soil strength when soil water retention was 10 bars in sandy loam soil. 3. From the pot experiment, the total length of roots were longer in loam soil than in sandy loam soil and was longer in the soils with lower bulk density. The average radius of fine roots grown in sandy loam soil was larger than that grown in loam soil. The total surface area of roots was greater in the loam soil with low bulk density than in the sandy loam soil with high bulk density as the total length of roots. 4. The amounts of nutrient uptake by soybean shoots were greater in loam soil primarily due to more production of dry matter than in sandy loam soil. The nitrogen influx rates through the unit surface area were 597 to $753nmoles/day-cm^2$ in loam soil and 222 to $365nmoles/day\;cm^2$ in sandy loam soilshowing higher value in higher bulk density. The potasium influx rates were 99 to $175nmoles/day-cm^2$, and those of phosphate were 26 to $46nmoles/day\;cm^2$. Those of Ca and Mg were 175 to 246 and 163 to $205nmoles/day\;cm^2$. The difference in nutrient influx rates between bulk densities of these elements were lower than that of nitrogen.

  • PDF