• Title/Summary/Keyword: water heating

Search Result 1,969, Processing Time 0.042 seconds

Effect of Ohmic Heating on Characteristics of Heating Denaturation of Soybean Protein (옴 가열이 대두 단백질의 열변성에 미치는 영향)

  • Cha, Yun-Hwan
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.4
    • /
    • pp.740-745
    • /
    • 2011
  • Ohmic heating uses electric resistance heat which occurs equally and rapidly inside food when an electrical current is passed throught. In this study, we observed the physical & chemical characteristics changes which occurs in soybean protein during heating denaturation by using ohmic and conventional heating. After the ohmic heating process, we could not find any change of the primary protein structure in the denaturated soy protein samples. However, the rate of imbibed water(RIW) of the ohmic samples was 2 times faster than that of the conventional samples. Also the ANS-surface hydrophobicity was decreased, which is very closely related to RIW. In the differential scanning calorimeter(DSC) analysis result, all 7S soyprotein fraction samples were completely denaturated by ohmic and conventional heating. However, the 11S samples were completely denatured only by ohmic heating. According to the DSC result, we decided that soyprotein was damaged by temperature and electrical current during ohmic heating. The damage of electrical current was a cause of the characteristic changes.

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Power Generation and Control System Using Differential Pressure of District Heating Pipeline in a Substation (지역난방 사용자기계실 내 열수송관 차압을 이용한 발전 및 제어 기술)

  • Kim, Kyung Min;Park, Sung Yong;Oh, Mun Sei
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.90-96
    • /
    • 2017
  • When the hot water is supplied through the district heating (DH) pipeline, a pressure differential control valve (PDCV) protects the DH user equipment from the high pressure DH water and helps to supply DH water to long distance. It also controls the temperature and adjust the pressure in the main district heating pipeline. However, cavitation occurs in PDCV due to the use of high pressure DH water. It causes frequent failures and many problems. It also causes energy loss and complaints to both operators and users. In order to solve these problems, we will introduce the energy saving technology to replace the primary side PDCV with hydraulic turbine, convert the differential pressure into electricity, and utilize electricity as the power of the secondary side pump.

Optimization Design of Solar Water Heating System based on Economic Evaluation Criterion using a Genetic Algorithm (유전알고리즘 이용 경제적 평가기준에 따른 태양열급탕시스템 최적화 설계에 관한 연구)

  • Choi, Doosung;Ko, Myeongjin;Park, Kwang-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.73-89
    • /
    • 2016
  • To assure maximum economic benefits and the energy performance of solar water heating systems, the proper sizing of components and operating conditions need to be optimized. In recent years, a number of studies to design optimally solar water heating systems have been tried. This paper presents a design method for optimizing the various capacity-related and installation-related design variables based on life cycle cost using a genetic algorithm. The design variables considered in this study included the types and numbers of solar collector and auxiliary heaters; the types of storage tanks and heat exchangers; the solar collector slope; mass flow rates of the fluid on the hot and cold sides. The suggested method was applied for optimizing a solar water heating system for an elementary school in Seoul, South Korea. In addition, the effectiveness of the proposed optimization method was assessed by analyzing the obtained optimal solutions of six case studies, each of which was simulated with different solar fractions. It is observed that a trade-off between the equipment cost and the energy cost results in an optimal design that yields the lowest life cycle cost. Therefore, it could be helpful to apply the optimal solar water heating system by comparing the various design solutions obtained by using the optimization method instead of the engineer's experience and intuition.

Studies on the Processing of Rapid- and Low Salt-Fermented Liquefaction of Sardine (Sardinops melanoslicta)(III) - Effect of Pretreatment Method on Water Adding, Heating, and NaCl Added to the Fermented Liquefaction of Chopped Whole Sardine - (저식염 속성 정어리 발효 액화물 가공에 관한 연구(III) - 마쇄육의 발효 액화에 미치는 가수.가온 전처리 및 식염첨가 방법의 영향 -)

  • Park, Choon-Kyu
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.2
    • /
    • pp.95-100
    • /
    • 2000
  • This study was attempt to improve the quality of rapid- and low salt-fermented liquefaction of sardine (Sardinops melanoslicta). Effect of pretreatment methods such as water adding, heating, and intermittent NaCl adding on fermented liquefaction of chopped whole sardine were investigated. The divisions of the experimental samples by pretreatment methods were as follows; Sample A (water adding and heating): chopped whole sardine adding 20% water and then adding 3 and 5% NaCl consecutively at the intervals of 3 and 6 hrs during heating for 9 hrs at $50^{\circ}C$ and then fermented at $33^{\circ}C$ for 90 days. Sample B (preheating): chopped whole sardine with 8% NaCl and heating at $50^{\circ}C$ for 9 hrs and then fermented at $33^{\circ}C$ for 90 days. Sample C (control): neither pretreatment methods of water adding nor preheating on chopped whole sardine with 13% NaCl and then fermented at $33^{\circ}C$ for 90 days. Comparison of the appropriate fermentation period, yield of hydrolysate, chemical composition of fermented liquefied products were carried out. The highest content of amino nitrogen appeared at 60 days in the sample A, 75 days in the sample B, and 90 days in the sample C during the fermentation period. The appropriate fermentation period of the sample A was shorten 15 days than the sample B and 30 days than the sample C in the processing of sardine. The product A was lower NaCl (8.5%) and lower histamine content (25mg/100g) than the sample B and C. Possibly, three kinds of pretreatment methods such as water adding, heating, and intermittent NaCl adding, might be recommend as the processing of rapid- and low salt-fermented liquefaction product of chopped whole sardine.

  • PDF

Greenhouse Heating Technology Development by using Riverbank Filtration Water (강변여과수를 이용한 온실난방기술 개발)

  • Moon, Jong-Pil;Lee, Sung-Hyoun;Kwon, Jin-Kyung;Kang, Youn-Ku;Ryou, Young-Sun;Lee, Su-Jang
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.6
    • /
    • pp.145-152
    • /
    • 2011
  • In order to heat greenhouse nearby river channel, riverbank filtration water source heat pump was developed for getting plenty of heat flux from geothermal energy. Recharging well, thermal storage tank with separating insulation plate and filtering tank for eliminating iron, manganese were mainly developed for making the coefficient of performance (COP) of heat pump higher. Heating system using riverbank filtration water source heat pump was installed at a paprika greenhouse in the Jinju region where a single fold of vinyl cover and 2 layers of horizontal thermal curtain were installed as a part of temperature keeping and heat insulation with a greenhouse area of 3,185 $m^2$. 320,000 kcal/h was supplied for performing a site application tests. A greenhouse heating test was performed from Feb. 1, 2011 to Apr. 30, 2011. As the result of that, COPh of the heat pump was measured in the range of 4.0~4.5, while COPS of the system was represented as 2.9~3.3. COP measured of the heat pump was very good and well responded to indoor heating temperature of the environment control system of a greenhouse.

A Study on the Greenhouse Heating Performance of Heat Pump System (온실난방을 위한 히트펌프의 성능에 관한 연구)

  • 윤용철;서원명;이석건
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.3
    • /
    • pp.94-102
    • /
    • 1998
  • This experiment was carried out to study on the effect of greenhouse heating by water-to-water heat pump system employing heating water tank(ground water) as the heat source. Followings are the results obtained from this study ; 1. The heat amount absorbed from evaporator and the heat amount rejected from condenser were approximately 9, 000~ 12, 000kcal/h and 13, 000~ 17, OOOkcal/h, respectively. 2. The heat efficiencies of evaporator and condenser used in this experiment were approximately 79% and 83%, respectively. 3. The maximum heating load estimated for the experimental greenhouse was about 18, 000 ~ 25, OOOkcal/h, which was found to be about 28 ~ 32% higher than the heating capacity of the heat pump system adopted for this experiment. 4. The coefficients of performance(COP) for the heat pump and the total heat pump system were approximately 2.9~3.5 and 1.5~2.4, respectively. 5. The coefficient of performance(COP) calculated from the Mollier Diagram was about 3.2 ~ 3.4, which was reasonably close to the COP estimated on the basis of measured values. 6. The temperature of experimental greenhouse heated by the heat pump system could be maintained about 12~15 。C higher than that of a control greenhouse.

  • PDF

A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System (태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究))

  • Lee, Young-Soo;Lee, Ki-Woo
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

A Fuel Feasibility Study of Sewage Sludge by Melting of Thermoplastic Polyethylene

  • Lee, Byeong-Kyu;Jeong, Wang-Seok
    • Journal of Environmental Science International
    • /
    • v.19 no.1
    • /
    • pp.9-16
    • /
    • 2010
  • This pilot study evaluated fueling feasibility of sewage sludge, which contains a large amount of water content, by applying melting of thermoplastic polyethylene (PE). This study has identified a simultaneous achievement of drying and heating value improvement of the sewage sludge. The sewage sludge collected from a sewage sludge treatment plant during a winter period had a water content of 83.7 wt%, a combustible volatile content of 12.5 wt%, and an ash content of 3.8 wt%. The higher heating value (HHV) of the dried sewage sludge, before impregnation or coating of PE, was 4,600 kcal/kg. The collected sewage sludge was immersed into the melted PE solution, which had a HHV of 11,070 kcal/kg, and kept immersing with increasing reaction time. As the reaction (immersing or coating or impregnation) time increased, the water content of the sludge decreased. However, the HHV of the sludge increased with increasing the reaction time. The HHVs of the sewage sludge immersed or dipped into the melted PE solution for 15 min ranged from 6,780 to 8,170 kcal/kg with water content less than 7 wt%. This result indicates the melted PE solution can be utilized as an improvement technology for dryness and heating value of the sewage sludge with high water content. The sewage sludge impregnated or coated with melted PE can be utilized as potential fuel or energy resources.

A Study on the Solar Water Heating System in the Military Facilities (병영시설의 태양열급탕시스템에 관한 연구)

  • Kim, Doo-Chun;Seo, Jin-Seok
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.4
    • /
    • pp.6-18
    • /
    • 1982
  • The performance of two typical types of solar hot water heating system was tested in Seoul. Types of systems studied are single-tank internal external heat exchanger system and single-tank internal heat exchanger system. Comparing to experimental results, a transient system simulation program was made to analyze the performance of the selected system. The climate data, Standard Weather Year for Seoul, required for the simulation was provided. Computer simulations were used to estimate the effect of significant parameters upon system performance. The followings are obtained. 1. In the domestic solar water Heating system, the value $20-40kg/m^2\;h$ for flow rate through the collector is much better than the recommended value $72kg/m^2\;h$ in the solar heating system. 2. The effectiveness of collector heat exchanger and storage tank size are found to have only a small effect upon system performance. 3. The hot water draw pattern has a significant effect on system performance. A higher system efficiency achieved when draw-off occurred around noon than when it occurred around early morning. Using the above results, the reference solar hot water system which provides $300\ell$ of hot water per day, was selected as a guide for designer. And simplified graphical method was developed based on the modified f-chart method to determine required collector area. When the system design parameters of the proposed system differs from the reference system, required collector area can be calculated from area adjustment factors.

  • PDF