• 제목/요약/키워드: water hammer

검색결과 165건 처리시간 0.029초

수도관로 소수력발전설비에 수격작용으로 인한 고장대책 (Trouble and Measure Owing to Water-hammer in Small Hydropower Turbine System Of Waterpipe)

  • 이형묵;김기원;변일환;홍정조;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.671-672
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

전산유체해석(CFD)을 이용한 밸브의 급폐쇄에 따른 다중 배관 수격 현상에 관한 연구 (Study on a Multi-pipe Water Hammer Phenomenon by using CFD of Rapid Valve Closing)

  • 박노석;김성수;강문선;최종웅
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.479-487
    • /
    • 2013
  • This study was to investigate characteristics for the pressure wave propagation and the maximum pressure near a rapid closure valve which was installed the end of multi piping network. The multi piping network consists of one inlet and three outlet with straight pipes. The diameter of the pipes including the valve was 100 mm, 80 mm, 80 mm respectively. The valve was rapidly closed with the instantaneous time which was 0.023s in the level for the water hammer. For the simulation, the influence of the pipe thickness and deformation due to pressure-wave-propagation was not considered. CFD was conducted under the following condition : the initial pressure was 1bar in the inlet and the mass flow rate was 7.83 kg/s in the outlet(the velocity in the pipe with 100 mm diameter was 1 m/s). As the valve have conditions that were status with and without fluid flow in the pipe after valve closing, the maximum pressure change and the frequency analysis were examined. As the results, the case that was status with fluid flow appeared the higher maximum pressure than another's, the maximum frequency band was about 10 ~ 11 Hz.

수도관로 소수력발전설비에서의 수격작용으로 인한 고장대책 (Trouble and Measure Owing to Water-hammer In Small Hydropower Turbine System Of Waterpipe)

  • 이형묵;홍정조;이은웅;김경엽
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.61-64
    • /
    • 2006
  • Recently the development of small hydropower generation with using water pipes is revitalized by the water works facilities. However, when the tubine generator is in case of emergency stop by the internal and external accidents, it causes water hammer in water pipes and suspension of water supply. To prevent these problems of small hydropower generator, we has analyzed water supply patterns, installation position and water pipe systems.

  • PDF

Schmidt hammer 반발지수로 울산지역 퇴적암의 공학적 특성을 추정하기 위한 연구 (A Prediction of Engineering Properties of Ulsan Sedimentary Rocks with Schmidt Hammer Rebound Number)

  • 민덕기;문종규
    • 한국지반공학회논문집
    • /
    • 제22권10호
    • /
    • pp.139-150
    • /
    • 2006
  • 울산분지 퇴적암을 대상으로 Schmidt hammer 타격시험을 시행하여 일축 압축강도, 압열 인장강도, 탄성계수, 흡수율 및 간극율과의 상호 관계를 구명하였다. 기 연구된 결과는 여러 암종이 혼합된 결과로 실용적 적용에 어려움이 있어 지질학적 생성배경의 차이로 인한 원인을 배제하고 실용적 적용에 유용하도록 울산분지 퇴적암만을 대상으로 하여 연구를 시행하였다. Schmidt 햄머 반발지수와 각 실험결과상호간에 높은 상관성이 있으며 본 연구 결과 값으로 상호 교차검정을 한 결과도 만족할 수 있는 결과가 도출되었다.

과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안 (A Safety Plan for the Pumping Station by Hydraulic Transient Analysis and Demonstration)

  • 라병필;김진만;이동근;박종호;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.22-28
    • /
    • 2005
  • As the water supply facilities are recently getting larger, the domestic waterworks become multi-regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment plant and water supply/distribution facilities. Although the pumping stations and the pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. In this paper, the intake pumping station is guaranteed by both the computer simulation and the field test analysis. This study is contributed to the safe operation program for the pumping station in which results of the adjustment on the safety plan of the pumping station, the air valve and the valve closing time.

과도수리현상 해석과 실증을 통한 펌프장 안정성 확보방안 (The Plan of Safety for Pump Station through Hydraulic Transient Analysis & Demonstration)

  • 라병필;김진만;박종호;김경엽
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.199-207
    • /
    • 2004
  • Water supply facilities are recently getting larger according as domestic waterworks become multi regional water supply system. Large water supply facilities generally consist of the intake pumping station, water treatment station and water supply & distribution facilities. Although pumping stations and pipeline systems are used to pump up water, it often happens pipeline damage and flooding accident by the water hammer. As a result of this study, a pumping station is guaranteed by the computer simulation and field test analysis. Therefore these are contributed safety operation in pumping station through adjustment of the pumping station safety plan, air valve and valve closing time.

  • PDF

급수용 급속공기밸브의 성능특성에 관한 실험적 연구 (Experimental Study on Performance Characteristics of High Speed Air Valve for Water Works)

  • 이선곤;강세호;양철수;우창기
    • 한국안전학회지
    • /
    • 제29권5호
    • /
    • pp.1-6
    • /
    • 2014
  • When the fluid energy convert into kinetic energy due to water hammer, the propagation velocity of pressure wave appear. The propagation velocity of pressure wave(1050 m/s) of very fast could be damage to the pipeline system. If the occurrence of water hammer is due to down-pressure, the faster the air exhaust or supply device is needed. it is high Speed Air Valve. In this paper, Each 3.12, 3.13, 3.72, $3.74kg/cm^2$ pipeline pressure were setting, and then executed pressure rapid drop for obtaining a high Speed Air Valve Operating time and pressure change data. the result was that pipe line pressure stabilization time were each 0.98, 1, 1.22, 1.25 sec. In other words, that pressure drop experimental results pipe line pressure was equal to atmospheric pressure without negative pressure After about one second. The study result would be useful to pipe line system stability design because this data could be foresee pressure stabilization time.

Examination of Cavitation-Induced Surface Erosion Pitting of a Mechanical Heart Valve Using a Solenoid-Actuated Apparatus

  • Lee, Hwan-Sung;Hwang, Sung-Won;Katsuyuki Yamamoto
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1339-1348
    • /
    • 2003
  • Several factors, including peak dp/dt of the ventricular pressure and maximum closing velocity of leaflet have been studied as indices of the cavitation threshold. In the present study, just before closing velocity of the leaflet has been studied as indices of the cavitation threshold, and cavitation erosion on the surface of a mechanical valve was examined by focusing on squeeze flow and the water hammer phenomenon during the closing period of the valve. A simple solenoid-actuated test device that can directly control the valve closing velocity was developed, and opening-closing tests of 3,000 and 40,000 cycles were performed at various closing velocities. There was a closing velocity threshold to occur erosion pitting of valve surface, and its value was about 0.4 m/s in this study. Cavitation-induced erosion pits were observed only in regions where squeeze flow occurred immediately before valve closure On the other hand, the number of the pits was found to be closely related to an area of water hammer-induced pressure wave below the critical pressure defined by water vapor pressure. Therefore, it was concluded that cavitation is initiated and augmented by the two pressure drops due to squeeze flow and water hammer phenomenon, respectively.

콘덴서 냉각수 계통내의 수격현상 에 관한 수치해석 (Numerical Analysis of Water Hammer in Condenser Cooling Water Systems)

  • 장효환;정회범
    • 대한기계학회논문집
    • /
    • 제9권5호
    • /
    • pp.638-646
    • /
    • 1985
  • 본 논문에서는 펌프가 동시에 전원차단 되었을 때 송출밸브의 운전조건(개도, 폐쇄속도), 계통의 기하학적 형상(취수 및 배수관로의 길이, 단면적, 재질, 콘덴서의 높이등)과 해면상태(간막의 차에 의한 수위, 파도)의 변화가 계통내 수격현상에 미치 는 영향에 대하여 수치해석 하였다.