• 제목/요약/키워드: water environmental management

검색결과 2,961건 처리시간 0.028초

Putting Climate Change into Water Resource Management: Adaptation Efforts in the U.S., U.K., Canada, Australia, and the Netherlands

  • Chang, Hee-Jun;Franczyk, Jon;Bae, Deg-Hyo
    • 환경정책연구
    • /
    • 제5권4호
    • /
    • pp.19-49
    • /
    • 2006
  • 기후변화가 지역의 수자원에 영향을 미칠 것으로 예상됨에 따라 수자원 관리자들은 이에 대응한 적응전략을 수립하는 것이 필요하다. 이에 본고에서는 미국, 영국, 캐나다, 오스트렐리아, 네덜란드의 적응관리의 실태를 검토하였다. 이들 나라들은 현재의 수자원 관리관행, 제도적 장치, 기후변화의 잠재적 수자원 영향에 따라 매우 상이한 적응관리를 하고 있다. 이들 나라들의 비교연구를 통하여 기후변화에 따른 한국에서의 지속 가능한 수자원 관리를 위한 정책적 관련성을 도출하였다.

  • PDF

한국에서의 환경영향평가와 환경측정 (Environmental Impact Assessment and Environmental Monitoring in Korea)

  • 강인구;김명진
    • 환경영향평가
    • /
    • 제4권3호
    • /
    • pp.31-39
    • /
    • 1995
  • Environmental Impact Assessment (EIA) is composed of various procedures, such as screening, scoping, inventory survey, prediction, assessment, alternative assessment, mitigation measures, and post management. Environmental monitoring data for air quality or water quality, etc. is applied in the EIA process, especially in prediction and post management. As an effective tool of environmental monitoring, the remote sensing method, introduced recently, was used in collecting nationwide data concerning ecosystem and land use. This article explains the current monitoring status in Korea. Monitoring factors include air quality, water quality, soil, ocean, odor, noise, and ecosystems. This report explains the organization of the environmental monitoring system managed by the Ministry of Environment in Korea. Furthermore, it shows the environmental criteria and environmental policies applied to EIA in Korea.

  • PDF

수질오염총량관리제에서 난분해성 유기물질 관리 필요성 및 개선방안 (Necessity of Refractory Organic Matters Management in Total Maximum Daily Loads (TMDLs))

  • 박재홍;박배경;이재관;류덕희
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.393-399
    • /
    • 2013
  • To control organic matters, it needs to manage not only biodegradable organic matters but also refractory organic matters. Refractory organic matters from municipal wastewater, industrial wastewater, non-point sources and etc., have been continuously discharged to the near watersheds. It is estimated that the refractory organic matter ratios are continuously increased in waterbody. In watersheds of the Total Maximum Daily Loads (TMDLs), it was investigated that COD/BOD ratios increased in many unit watersheds of the 4 major river basins. The portions COD/BOD ratios increased were found to be a 97% of Geum River unit watersheds, a 81% of Yeongsan/Seumjin River unit watersheds, a 78% of Nakdong River unit watersheds, a 70% of Han River unit watersheds, respectively. Therefore, it has become important for establishment of effective management strategies to control refractory organic matter in watersheds of the Total Maximum Daily Loads (TMDLs). In order to properly manage organic matters including refractory organic matters, the present organic indicator (BOD) has to be converted to TOC (or COD). Compared to COD and BOD, TOC, as a organic matter indicator, is evaluated more appropriate.

수질오염총량관리 단위유역 유량측정자료를 이용한 유황곡선 작성 (Development of a Flow Duration Curve with Unit Watershed Flow Data for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권2호
    • /
    • pp.224-231
    • /
    • 2012
  • It is necessary to develop flow duration curve (FDC) on each unit watershed in order to analyze flow conditions in the stream for the management of Total Maximum Daily Loads (TMDLs). This study investigated a simple method to develop FDC for the general use of the curve. A simple equation for daily flow estimation was derived from the regression analysis between the 8-day interval flow data of a unit watershed and the daily flow monitoring data of an adjacent upstream region. FDC can be prepared with the calculation of daily flow by the equation for each unit watershed. An annual and a full-period FDC were drawn for each unit watershed in Guem river basin. Standard flow such as low and ordinary flow can be obtained from the annual FDC. Major percentile of flow such as 10, 25, 50, 75 or 90% can be obtained from the full-period FDC. It is considered that this simple method of developing FDC can be utilized more widely for the calculation of standard flow and the assessment of water quality in the process of TMDLs.

차집관로와 하수처리시설의 설치에 따른 도시하천의 수질변화 특성 (Characteristics of Water Quality Change of Urban River according to Installation of Interceptors and Wastewater Treatment Plant)

  • 주연연;임봉수
    • 대한환경공학회지
    • /
    • 제36권12호
    • /
    • pp.813-820
    • /
    • 2014
  • 대전 3대하천을 대상으로 차집관로와 하수처리시설 증설로 인한 도시하천의 수질변화의 특성을 분석하였다. 지난 10년 동안 최고 수질에서 최저 수질의 차이가 가장 큰 하천지점은 하수처리시설 하류부인 갑천5(신구교) 지점이다. 반면에 최근 수질은 이 지점이 다른 지점보다 수질이 불량한 것은 하수처리시설의 방류수 영향이다. 하수처리시설 상류부에서는 대전천이 유기물질의 오염감소에서 다른 지점보다 비교적 양호한 지점인데 이는 차집관로의 유지관리 투자에 기인한 것으로 보인다. 최근 3대하천 수질은 하천수질기준치와 비교하였을 때 대부분 수질항목은 기준치 이내로 적합하였으나 상류지점인 대전천, 유등천, 갑천3 지점의 총인은 기준치에 못 미치므로 하수처리시설 상류부가 하류부보다 차집관로의 유지관리가 더 필요하다. 하수처리시설의 방류수 수질이 하천 수질오염총량관리 지점의 목표수질에 악영향을 주기 쉬우므로 하수처리시설 유지관리의 효율성이 적극 요구된다.

강우유출오염부하를 고려한 호수수질모델링 (Lake Water Quality Modelling Considering Rainfall-Runoff Pollution Loads)

  • 조재현;강성효
    • 환경영향평가
    • /
    • 제18권2호
    • /
    • pp.59-67
    • /
    • 2009
  • Water quality of the Lake Youngrang in the Sokcho City is eutrophic. Jangcheon is the largest inflow source to the lake. Major pollutant sources are stormwater runoff from resort areas and various land uses in the Jangcheon watershed. A storm sewer on the southern end of the lake is also an important pollution source. In this study, water quality modelling for Lake Youngrang was carried out considering the rainfall-runoff pollution loads from the watershed. The rainfall-runoff curves and the rainfall-runoff pollutant load curves were derived from the rainfall-runoff survey data during the recent 4 years. The rainfall-runoff pollution loads and flow from the Jangcheon watershed and the storm sewer were estimated using the two kinds of curves, and they were used as the flow and the boundary data of the WASP model. With the measured water quality data of the year 2005 and 2006, WASP model was calibrated. Non-point pollution control measures such as wet pond and infiltration trench were considered as the alternative for water quality management of the lake. The predicted water quality were compared with those under the present condition, and the improvement effect of the lake water quality were analyzed.

Copper and Lead Concentrations in Water, Sediments, and Tissues of Asian Clams (Corbicula sp.) in Bung Boraphet Reservoir in Northern Thailand (2008)

  • Netpae, Tinnapan;Phalaraksh, Chitchol
    • Environmental Engineering Research
    • /
    • 제15권1호
    • /
    • pp.35-40
    • /
    • 2010
  • Bung Boraphet is the largest freshwater reservoir in Thailand. This study examined the accumulation of copper (Cu) and lead (Pb) in water, sediment and tissues of Asian clams (Corbicula sp.) within Bung Boraphet to assess the possible polluting effect of soil erosion and the dissolution of water soluble salts from the Nan River. Samples were collected from 12 study sites within Bung Boraphet between February and December 2008. The physicochemical parameters of the water including temperature, pH, turbidity, ammonia nitrogen, nitrate nitrogen, orthophosphates, biochemical oxygen demand, dissolved oxygen, Cu, and Pb were measured. The water in Bung Boraphet was found to be medium clean according to the surface water quality standard of Thailand. The levels of Cu and Pb in the water were low but heavy metals were detected at higher levels in the sediment and tissues of Corbicula sp. In the near future, management practices and regulator approaches for Cu and Pb contamination will be needed to protect the water in Bung Boraphet.

통계분석 및 수질지수를 이용한 남한강 하류 유역의 수질 평가 (Assessment of Water Quality in the Lower Reaches Namhan River by using Statistical Analysis and Water Quality Index (WQI))

  • 조용철;최현미;류인구;김상훈;신동석;유순주
    • 한국물환경학회지
    • /
    • 제37권2호
    • /
    • pp.114-127
    • /
    • 2021
  • Water pollution in the lower reaches of the Namhan River is getting worse due to drought and a decrease in water quantity due to climatic changes and hence is affecting the water quality of Paldang Lake. Accordingly, we have used a water quality index (WQI) and statistical analysis in this study to identify the characteristics of the water quality in the lower reaches of the Namhan River, the main causes of water pollution, and tributaries that need priority management. Typically, 10 items (WT, pH, EC, DO, BOD, COD, SS, T-N, T-P, and TOC) were used as the water quality factors for the statistical analysis, and the matrix of data was set as 324 × 10·1. The correlation analysis demonstrated a strong correlation between Chemical Oxygen Demand (COD) and T-P with a high statistical significance (r=0.700, p<0.01). Furthermore, the result of principal component analysis (PCA) revealed that the main factors affecting the change in water quality were T-P and organic substances introduced into the water by rainfall. Based on the Mann-Kendall test, a statistically significant increase in pH was observed in SH-1, DL, SH-2, CM, and BH, along with an increase in WQI in SH-2 and SM. BH was identified as a tributary that needs priority management in the lower reaches of the Namhan River, with a "Somewhat poor" (IV) grade in T-P, "Fair" grade in WQI, and "Marginal" grade in summer.

상수관망 블록의 대표적인 용수사용 유형에 대한 최소 용수사용 시간의 결정 (Determining the Time of Least Water Use for the Major Water Usage Types in District Metered Areas)

  • 박수완;정소연
    • 상하수도학회지
    • /
    • 제29권3호
    • /
    • pp.415-425
    • /
    • 2015
  • Aging water pipe networks hinder efficient management of important water service indices such as revenue water and leakage ratio due to pipe breakage and malfunctioning of pipe appurtenance. In order to control leakage in water pipe networks, various methods such as the minimum night flow analysis and sound waves method have been used. However, the accuracy and efficiency of detecting water leak by these methods need to be improved due to the increase of water consumption at night. In this study the Principal Component Analysis (PCA) technique was applied to the night water flow data of 426 days collected from a water distribution system in the interval of one hour. Based on the PCA technique, computational algorithms were developed to narrow the time windows for efficient execution of leak detection job. The algorithms were programmed on computer using the MATLAB. The presented techniques are expected to contribute to the efficient management of water pipe networks by providing more effective time windows for the detection of the anomaly of pipe network such as leak or abnormal demand.

수질오염총량 단위유역별 LDC(Load Duration Curve, 부하지속곡선) 적용을 통한 수질관리 대안 모색 - 금호강 유역 대상 (Water Quality Management Measures for TMDL Unit Watershed Using Load Duration Curve)

  • 윤소영;류재나;오재일
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.429-438
    • /
    • 2013
  • This study was to develop effective water quality management measures using LDC (Load Duration Curve) curves for TMDL (Total Maximum Daily Loads) unit watershed. Using LDC curves, major factors for BOD and T-P concentration loads generation (i.e. point source or non-point source) in the case study area (Geumho river basin) were found for different hydrologic conditions. Different measures to deal with the pollutant loads were suggested to establish BMPs (Best Management Practices). It was found that the target area has urgent T-P management methods especially at moist and midrange hydrologic conditions because of point source pollutants occurred in developed areas. One example measure for this could be establishment of advanced treatment facility. This study proved that the use of LDC was a useful way to achieve TWQ (Target Water Quality) on the target watershed considered. It was also expected that the methodology applied in this study could have a wider application on the establishment of watershed water management measures.