Characteristics of Water Quality Change of Urban River according to Installation of Interceptors and Wastewater Treatment Plant  

Zhou, Juan Juan (Department of Environmental Engineering, Daejeon University)
Lim, Bong Su (Department of Environmental Engineering, Daejeon University)
Publication Information
Abstract
In this study, the characteristics of water quality change of the three streams in Daejeon were analyzed according to the expanded installation of interceptors and wastewater treatment plant (WTP). Gabcheon 5 (Singu Bridge) location showed the maximum difference of the highest and lowest concentrations in the last decade. However, the recent water quality of this location was worse than other locations, because of the impact of the effluent from the WTP. In the upstream of the WTP, the Daejeon stream was relatively better than the other locations in organic pollution reduction, and this was caused by the investment for the management of the interceptors in three streams of Daejeon. According to the water quality standard of the stream water quality, the recent water quality of the three streams in Daejeon was acceptable within them in the most of the water quality items, but because the total phosphorus concentration of the upstream such as Daejeon stream, Yudeng stream, Gabchen 3 location did not reach the standard values, a better management of the interceptor was required in the upstream of WTP than its downstream. The upstream of WTP also required a better management of the interceptor than the downstream. The operation and management of WTP was required a high efficiency because the water quality of the effluent from the WTP incurred an adverse effect to the target water quality in the location of the total water pollution load management system.
Keywords
Water Quality Standard of Urban Stream; Interceptor; Wastewater Treatment Plant; Operation and Management; Total Water Pollution Load Management System;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lim, B. S., Kim, T. E. and Chung, W. M., "Current state and improvement plan of water quality in Daejeon three streams," J. Region Develop. Daejeon Univ., 6, 73-96(1999).
2 Lee, G. Y., Kwon, D. Y., Kim, Y. A. and Han, C. K., "A Study on an environmental improvement plan of urban streams," J. Inst. Ind. Technol. Daejon Univ., 10(1), 49-62(1999).
3 Kwon, C. J., Kim, D. Y. and Lim, B. S., "Characteristics of water quality variation in gap stream lake park," J. Inst. Environ. Studies Daejeon Univ., 15, 83-99(2011).
4 Moon, Y. H., Evaluation on Importance and Satisfaction of Planning Elements of the Urban Waterfront : Focusing on Three Rivers of Daejeon City, Master Thesis, Paichai University, Daejeon(2014).
5 Ministry of Environment, http://www.me.go.kr/home/web/main.do(2014).
6 Yong, J. H., Condition of River and Wetland Design in Deajeon for Improvement Water Quality, Master Thesis, Chungnam National University, Daejeon(2008).
7 Water Information System, http://water.nier.go.kr/main/mainContent.do(2014).
8 Kim, S. T., Study on Daejeon Revised Environmental Standard and Establishing an Environmental Improvement Measures, Daejeon Green Environment Center, Daejeon(2013).
9 Daejeon Metropolitian City, The Famework Ordinance on Environmen, Article 10(2014).
10 Lim, B. S., Improvement of Interceptor Sewers and Sewer Facility in Daejeon Metropolitian City, Daejeon Green Environment Center, Daejeon, pp. 17-31(2013).
11 Daejeon Metropolitian City, The 2nd Stage Enforcement Plan for Total Water Pollution Load Management System in Daejeon City(2013).
12 Ryu, B. R., A study for Environment Friendly Management Plan of Daejeon 3 River, Daejeon Green Environment Center, Daejeon(2013).
13 Lee, E. H. and Seo, D. I., "Water Quality Characteristics and Management of Major Streams of Taejon City," In Proceedings of the spring meeting of Korean Society of Environment Engineers, KSEE, Seoul University, Seoul(1997).