• Title/Summary/Keyword: water environmental management

Search Result 2,968, Processing Time 0.026 seconds

Consideration on the Operation of water level management and Environmental Change Associated with Inner Dike Constructions in Saemangeum Reservoir (새만금호 방수제 공사에 따른 관리수위 운영과 환경변화에 관한 고찰)

  • Choi, Jung-Hoon;Oh, Chan-Sung;Cho, Young-Kweon;Ahn, Chi-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.4
    • /
    • pp.290-298
    • /
    • 2013
  • A Saemangeum Development Project, which is a national project in South Korea, has started with the objective of developing the reclaimed area mainly agricultural land use since the mid'80s. To develop a model of the global eco-reclamation, constructions of the eco-friendly counter facilities such as sluice gates and inner dikes, as well as environmental preservation measures for an estuary reservoir, have been carried out. However, reasonable measures of the water quality management for the Saemangeum area are required. Thus, the purpose of this study is to rigorously analyze and quantitatively evaluate the environmental problems due to the water level management associated with inner dike constructions. To achieve these objectives, the affecting factors on determination of water level management are described and a series of calibrated transient-state numerical simulations was performed to demonstrate the salinity distribution difference in the estuary before and after the construction of inner dikes. The overall salinity reduced about 2~5 psu, and the seawater intrusion was weakened by a well-regulated waterway after construction of the inner dikes compared to before construction of them.

Water quality management of Jeiu Harbor using material cycle model(I) - The Variation of Physical Oceanographic Environments in Jeiu Harbor - (물질순환모델을 이용한 제주항의 수질관리(I) - 제주항의 물리해양환경의 변화 -)

  • 조은일;이병걸;오윤근
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.25-32
    • /
    • 2002
  • In order to control of water quality in Jeju harbor, variation of physical oceanographic environments was estimated using material cycle model. It is composed of the three-dimensional hydrodynamic model for the simulation at water flow and material cycle model for the simulation of water quality. The three dimensional hydrodynamic model simulation of the circulation and mixing in Jeju Harbor has been conducted forced by Sanzi River Discharge, Tidal elevation, wind and Solar heat in case of August and November, 2000 and February and May, 2001, respectively. The results of numerical model and observation show that the model can produce realistic results of current in the harbor. The monthly variation of velocity pattern are not so much changed are found In Jeju Harbor. The residual current was forced by temperature, salinity, density, wind and tidal current. The residual current of August, 2000 are the strongest among four month. It can be explained that the density effect can be important role in residual current at Jeju Harbor. As the results of salinity distribution simulation, very low concentration of all levels were simulated in August, 2000. The flowrate of Sanzi river was investigated 77,760 ㎥ /d in August, 2000. Therefore, pollutant loadings from Sanzi river should be considered for water quality management in Jeiu harbor.

Wetland transformation through Water Resource Users Association; The case of Rwamuthambi Sub Catchment area, Kenya

  • Kumunga, Eunice Muthoni;Ndiwa, Titus Chemandwa;Muthama, Nzioka John
    • Journal of Wetlands Research
    • /
    • v.22 no.3
    • /
    • pp.200-216
    • /
    • 2020
  • Many studies conducted in Kenya regarding water resource governance have focused on the mandate of Water Resource Users Associations (WRUAs) with less attention being accorded to their effectiveness in conservation of wetlands. This study assessed the effectiveness of WRUA committees, and challenges faced in conservation of Rwamuthambi Sub-catchment. The study employed exploratory descriptive research design. Data was collected through questionnaires, semi-structured interviews, observations and review of secondary data. Chi square and descriptive statistics was used to analyze the data. The survey results revealed that only 15% of WRUA committee understood water resources management while 35% were aware of relevant legislations. Factors of wetland degradation showed significant association with existence of WRUA (χ2 (4, N=180) = 20.46, p< .01) where (χ2- chi square (degrees of freedom, N = sample size) = chi-square statistic value, p = p value), although WRUA contributions were perceived differently per agro-ecological zone (χ2 (8, N=147) = 15.51, p>.05). Challenges unearthed were inadequate financial and human resources, lack of understanding, ineffective collaborative governance, poor support from county government and private ownership of riparian land reserve. There is need for WRUAs to embrace collaborative governance for effective conservation of wetlands. Integration of sub catchment management plan with county land use plans and policy review is also required.

Development of an Optimal Operation Model of Residual Chlorine Concentration in Water Supply System (송·배수시스템의 최적 잔류염소농도 관리 모델 개발)

  • Kim, Kibum;Hyung, Jinseok;Seo, Jeewon;Shin, Hwisu;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • This study aimed to develop a method to optimize residual chlorine concentrations in the process of providing water supply. To this end, this study developed a model capable of optimizing the chlorine input into the clearwell in the purification plant and the optimal installation location of rechlorination facilities, and chlorine input. This study applied genetic algorithms finding the optimal point with appropriate residual chlorine concentrations and deriving a cost-optimal solution. The developed model was applied to SN purification plant supply area. As a result, it was possible to meet the target residual chlorine concentration with the minimum cost. Also, the optimal operation method in target area according to the water temperature and volume of supply was suggested. On the basis of the results, this study derived the most economical operational method of coping with water pollution in the process of providing water supply and satisfying the service level required by consumers in the aspects of cost effectiveness. It is considered possible to appropriately respond to increasing service level required by consumers in the future and to use the study results to establish an operational management plan in a short-term perspective.

Performance Appraisal of Total Maximum Daily Loads: Performance on Development/Reduction Plan and Water Quality Status of Unit Watershed (수질오염총량관리제의 성과평가: 개발/삭감계획의 이행실적 및 단위유역의 수질 현황)

  • Park, Jae Hong;Park, Jun Dae;Rhew, Doug Hee;Jung, Dong Il
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.481-493
    • /
    • 2009
  • This study was conducted to performance appraisal of Total Maximum Daily Loads (TMDLs), especially in terms of performance on development & reduction plan and water quality status of unit watershed. Because load allocations for pollution sources were predicted redundantly by uncertainty of prediction, TMDLs master plan has been frequently changed to acquire load allocation for local development. Therefore, It need to be developed more resonable prediction techniques of water pollution sources to preventing the frequent change. It is suggested that the reduction amount have to be distributed properly during the planning period. In other words, it has not to be concentrated on the specific year (especially final year of the planning period). The reason why, if the reduction amount concentrate on the final year of the planning period, allotment loading amount could not be achieved in some cases (e.g., insufficiency of budget, extension of construction duration). If the development plan was developed including uncertain developments, it is necessary to be developed reduction plan considered with them. However, some of the plans in the reduction plan could not be accomplished in some case. Because, it is not considered financial abilities of local governments. Consequently, development plan must be accomplished to avoid uncertain developments, and to consider financial assistance to support the implementation of effective plan. Water quality has been improved in many unit watersheds due to the TMDLs, especially in geum river and yeongsang/seomjin river.

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

The Optimal Control Systems of Dilution Water and Point Sources for Water Quality Management in Stream (하천 수질관리를 위한 희석수량 및 점오염원의 최적 제어시스템)

  • Shim, Soon Bo;Han, Jae Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.295-305
    • /
    • 1993
  • The purpose of this study is to investigate the theoretical methodology for development of an water quality management system with the optimal control of dilution water and point sources in streams. For the development of objective function and constraints, the control vectors are defined with stream inflows and concentrations of effluents at water treatment plant, and the state vectors are defined with water quality parameters such as DO, $BOD_5$, COD and SS concentrations. The applied system solution technique is augmented Lagrangian technique. The developed water quality optimal management methodology was applied to a case study at the Musim stream in Cheong-ju city. The results of the application show that the methodology is suitable for the comprehensive analysis of polluted water systems, and will be utilized to more useful operation of limited water resources in Korean streams.

  • PDF

Removal of acetaminophen from wastewater by constructed wetlands with Scirpus validus

  • Phong, Vo Hoang Nhat;Koottatep, Thammarat;Chapagain, Saroj Kumar;Panuvatvanich, Atitaya;Polprasert, Chongrak;Ahn, Kyu-Hong
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.164-170
    • /
    • 2016
  • Since most of the existing wastewater treatment options lack the ability to treat micro-contaminants, the increased use of pharmaceuticals and personal care products (PPCPs) and release as human waste have become a serious concern in recent years. Constructed wetlands (CWs) are a low-cost technology for wastewater treatment, however, its performance in term of PPCPs removal has not yet been fully investigated. This study aimed to characterize the removal factors and efficiency of acetaminophen (ACT) removal by CWs. The results revealed the decreased concentrations of ACT with increasing hydraulic retention times (HRT) of 0, 3, 5 days. The contribution of removal factors was found to be varied with initial ACT concentration. At the low ACT concentration (i.e. 1 ppb), plant uptake was the dominant, followed by microbial and photolytic removal. In contrast, at the high ACT concentration (i.e. 100 ppb), microbial and photolytic removal were found as dominant factors. On the other hand, hydrogen peroxide ($H_2O_2$) concentration was found at higher level in the plant shoot than in the root probably due to occurrence of the Fenton reaction resulting in PPCPs removal.

Development of Impact Evaluation and Diagnostic Indicators for Sinkholes

  • Lee, KyungSu;Kim, TaeHyeong
    • International Journal of Contents
    • /
    • v.14 no.3
    • /
    • pp.53-60
    • /
    • 2018
  • Based on the previous studies on sinkholes and ground subsidence conducted until date, the factors affecting the occurrence of sinkholes can be divided into natural environmental factors and human environmental factors in accordance with the purpose of the study. Furthermore, to be more specific, the human environment can be classified into the artificial type and the social type. In this study, the assessment indices for assessing risks of sinkholes and ground subsidence were developed by performing AHP analysis based on the results of the study by Lee et al. (2016), who selected the risk factors for the occurrence of sinkholes by performing Delphi analysis targeting relevant experts. Analysis showed that the artificial environmental factors were of significance in affecting the occurrence of sinkholes. Explicitly, the underground factors were found to be of importance in the natural environment, and among them, the level of underground water turned out to be an imperative influencing factor. In the artificial environment, the underground and subterranean structures exhibited similar importance, and in the underground structures, the excessive use of the underground space was found to be an important influencing factor. In the subterranean ones, the level of water leakage and the erosion of the water supply and sewage piping system were the influential factors, and in the surface, compaction failure was observed as an imperative factor. In the social environment, the regional development, and above all, the groundwater overuse were found to be important factors. In the managemental and institutional environment, the improper construction management proved to be the most important influencing factor.

A Study on Runoff Characteristics of Combined Sewer Overflow(CSO) in Urban Area Using GIS & SWMM

  • Kim, Jae-Hoon;Paik, Do-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.467-474
    • /
    • 2005
  • The runoff characteristics of combined sewer overflow(CSO) in the urban area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model) and GIS. From August to November 2004, investigations on two rainfall events were performed and flowrate, pH, BOD, COD, SS, T-N and T-P were measured. these data were used for model calibration. Using GIS technique, watershed characteristics of study area were calculated. that is, divide into sub_basin, total width, slope, make soil map etc. On the basis of the measured data and the simulation results by SWMM, it could be known that the $80-90\%$ of pollution load are discharged in early-stage storm runoff. SMC(site mean Concentration) for combined sewer system area were BOD 28.1, COD 31.5, SS 186 ppm etc. this is shown that during the rain fall, high concentration of waste was loaded to receiving water. Unit loads of combined sewer system area were BOD 306, COD 410, SS 789, T-N 79, T-P 6.8 kg/ha/yr.