• Title/Summary/Keyword: water environmental management

Search Result 2,961, Processing Time 0.03 seconds

Analysis of Characteristics of NPS Runoff and Pollution Contribution Rate in Songya-stream Watershed (송야천 유역의 비점오염물질 유출 특성 및 오염기여율 분석)

  • Kang Taeseong;Yu Nayeong;Shin Minhwan;Lim Kyoungjae;Park Minji;Park Baekyung;Kim Jonggun
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.316-328
    • /
    • 2023
  • In this study, the characteristics of nonpoint pollutant outflow and contribution rate of pollution in Songya-stream mainstream and tributaries were analyzed. Further, water pollution management and improvement measures for pollution-oriented rivers were proposed. An on-site investigation was conducted to determine the inflow of major pollutants into the basin, and it was found that pollutants generated from agricultural land and livestock facilities flowed into the river, resulting in a high concentration of turbid water. Based on the analysis results of the pollution load data calculated through actual measurement monitoring (flow and water quality) and the occurrence and emission load data calculated using the national pollution source survey data, the S3 and S6 were selected as the concerned pollution tributaries in the Songya-stream basin. Results of cluster analysis using Pearson correlation coefficient evaluation and Density based spatial clustering of applications with noise (DBSCAN) technique showed that the S3 and S6 were most consistent with the C2 cluster (a cluster of Songya-stream mainstream owned area) corresponding to the mainstream of Songya-stream. The analysis results of the major pollutants in the concerned pollution tributaries showed that livestock and land pollutants were the major pollutants. Consequently, optimal management techniques such as fertilizer management, water gate management in paddy, vegetated filter strip and livestock manure public treatment were proposed to reduce livestock and land pollutants.

Impact of Seepage from Land Treatment of Pulp and Paper Effluent on Water Quality and Aquaculture

  • Wirojanagud, W.;Tantemsapaya, N.;Chalokpanrat, P.;Suwannakom, S.
    • Environmental Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.163-166
    • /
    • 2010
  • Pulp and paper mill wastewater has been treated by biological treatment, but the secondary effluent still contains high lignin, chemical oxygen demand, color and total dissolved solids. Tertiary treatment by land application, referred to as 'Project Green,' has been implemented to treat such high quantities of undesirable matters. The impacts of seepage from Project Green diffusing into receiving streams on the water quality and fish pen aquaculture were studied via the integration of technical and social approaches. The determination of the water quality was performed for 13 sampling stations along the receiving stream, including the Chot stream, Chot lagoon and the Pong River. The water quality was generally at normal levels, with the exception of total dissolved solids. The levels of matter were higher at the Chot stream, but became more diluted at the Chot lagoon and the Pong River, respectively. The social approach was conducted through the voluntary participation of the villagers as research assistants for the fish aquaculture study. Fish could grow at three fish pens within the study sites at the location of Project Green, the Chot lagoon and the Pong River. Fish growth at the Chot lagoon was better at the site of Project Green and the Pong River. The integration of technical and social approaches was a meaningful tool not only for the technical feasibility but in helping to solve the conflict between the community and industry.

Management of Water Quality of Embayments in Daechong Reservoir (대청호 정체수역의 수질예측과 관리)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.3 no.2
    • /
    • pp.33-45
    • /
    • 1994
  • Water quality of Chongju and Daejeon Water Intake Tower Region, embayments in Daechong Reservoir was found to be worse than that of main lake after analysis of water which were sampled during April, July, October in 1993. Concentration of COD and SS at those two water intake tower sites were 2.8-5.6 mg/l and 2.2-3.2 mg/l, higher than that of main lake. T-N concentration of those two sites was 1.1-1.9 mg/l similar to that of main lake, and T-P concentration of those two sites was 0.14-0.18 mg/l, higher than that of main lake. This study used water quality model of embayment which can analyse pollutant loads from stream and surrounding land use, advection, decay, and diffusion transport between embayment and main lake. The model can predict water quality of embayment according to the change of pollutant load, water elevation of embayment, quantity of water intake in order to suggest water quality management. This study suggests embayment water quality management alternatives, 1) construction of waste water treatment facilities at embayment and main lake for the decrease of pollutant loading, 2) water intake at main lake less polluted or eutrophicated than embayment, and 3) outflow elevation selection for polluted hypolimnion water outflow during stratification.

  • PDF

Managing Groundwater Resources in New Zealand to Account for Environmental Change

  • Davidson, Peter William
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.40-45
    • /
    • 2007
  • Water regulators in New Zealand have recognised the need to adapt water allocation regimes and water permit conditions to reflect the likelihood of lower catchment yield on the east coast from 2030 due to climate change. Water management mechanisms to protect the environment and maintain the reliability of other water users are currently being applied or assessed in Marlborough province. These include seasonal water quota based on spring aquifer status, linking water use to environmental triggers to avoid seawater intrusion or spring depletion; and redefining water permit entitlements to account for recharge variability.

  • PDF

A Study on integrated water management system based on Web maps

  • Choi, Ho Sung;Jung, Jin Young;Park, Koo Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.8
    • /
    • pp.57-64
    • /
    • 2016
  • Initial prevention activities and rapid propagation conditions is the most important to prevent diffusion of water pollution. If water pollutants flow into streams river or main stresm located in environmental conservation area or water intake facilities, we must predict immediately arrival time and the diffusion concentration to the proactive. National Institute of Environmental Research developed water pollution incident response prediction system linking dam and movable weir. the system is mathematical model which is updated daily. Therefore it can quickly predict the arrival time and the diffusion concentration when there are accident of oil spills and hazardous chemicals. Also we equipped with mathematical model and toxicity model of EFDC(Environmental Fluid Dynamics Code) to calculate the arrival time and the diffusion concentration. However these systems offer the services of an offline manner than real-time control services. we have ensured the reliability of data collection and have developed a real-time water quality measurement data transmission device by using the data linkage utilizing a mode bus communication and a commercial SCADA system, in particular, we implemented to be able to do real-time water quality prediction through information infrastructure of the water quality integrated management business created by utilizing the construction of the real-time prediction system that utilizes the data collected, the Open map, the visual representation using charts API and development of integrated management system development based on web maps.

Contamination Sources of Several Potentially Hazardous Compounds Found at the Gap Stream and the Miho Stream, Two Major Tributaries of the Geum River (금강 수계 주요지류인 갑천과 미호천에서 잠정유해물질 오염원 확인 연구)

  • Lee, Jun-Bae;Lee, Jay-Jung;Cho, Yoon-Hae;Yoon, Jo-Hee;Hong, Seoun-Hwa;Lee, Dae-Hee;Lee, Dae-Hee;Cho, Young-Hwan;Shin, Ho-Sang
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.15-23
    • /
    • 2016
  • BACKGROUND: Water quality is of concern to water utility operators, public health officials, and populations using the water. If any contaminant is released from a point of entry, it could be spread rapidly throughout the water stream. So the identification of the location of the points of entry and its release history are critical informations to establish the management strategy.METHODS AND RESULTS: Aniline, nonylphenol, pentachlorophenol and formaldehyde in 39 surface water samples were analysed using Gas chromatography-mass spectrometry (GC-MS) methods. Formaldehyde, aniline and nonylphenol were mainly detected in the near sites where industrial waste water and domestic sewage were discharged into stream. But pentachlorophenol was detected in the downstream samples where pulp manufacturing plants were operated.CONCLUSION: Results indicate that pentachlorophenol found in main stream of Guem river was mainly introduced from pulp manufacture industries. Otherwise, formaldehyde, aniline and nonylphenol were mainly contaminated from the industrial waste water and domestic sewage.

Environmental Indicators of Water Quality (수질환경척도)

  • Park, Jae-Hong;Choi, Euiso;Kong, Dong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.109-117
    • /
    • 2005
  • Understanding the condition of our nation's water resources, identifying what caused problems, and determining how to solve these problems are essential but difficult undertakings. The natural water cycle is itself intricate, and the addition of human activities increased this complexity. Consequently, answering the basic question "How clean and safe is our water?" is not easy. One way to present the condition of our water resources and the impacts of related human activities is to develop understandable measures, or indicators, that singly or in combination provide information on water quality. Managers and scientists can then use this information to develop effective solutions and make sound decisions to protect our water resources. It is important to note that environmental indicators can be used to measure a variety of phenomena. Indicators can present information on status or trends in the state of the environment, can measure pressures or stressors that degrade environmental quality, and can evaluate society's responses aimed at improving environmental conditions.

Application of Korean Water Quality Index for the Assessment of River Water Quality in the Basin of Daecheong Lake (대청호 유역의 수질평가를 위한 종합수질지수의 적용)

  • Chung, Se Woong;Park, Jae Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.470-476
    • /
    • 2005
  • The Korean Water Quality Index (K-WQI) was applied to the rivers located in the watershed of Daecheong Lake to assess the status of river water quality, and propose potential target constituents for better water quality management in the watershed. The estimated K-WQI value for each river was varied from 70 to 90, and Youngdongcheon showed the worst score while Mujunamdeachen showed the best score. The total nitrogen (TN) and total coliform bacteria were identified as the most significant constituents that degrade the K-WQI values in the rivers. The correlation coefficients (r) were determined between K-WQI and the delivered specific load ($kg/km^2/yr$) of BOD, TN, and TP to justify potential target constituents that have a great influence on the improvement of K-WQI values. The results showed that TN (r=-0.86) and TP (r=-0.85) have a strong negative relationships with K-WQI, but BOD have almost no effect. This implies that BOD, the surrogate parameter for organic pollutants, is no more a feasible water quality variable for the water quality management in the study site.

Improvement and Implementation to Enhance the Effectiveness of the Total Pollution Load Control System (수질오염총량관리제 실효성 제고를 위한 제도개선 및 추진 방향)

  • Seok-Gyu Kim;Seung-Young Oh;Su-Young Park;Eun-Hye Na;Yong-Seok Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.343-355
    • /
    • 2023
  • After the implementation of the total pollution load control system, the effect of improving river water quality by expanding investments in basic environmental facilities, inducing operational efficiency, and reducing the load of various pollutants was clear. However, since the implementation of the system, the management of non-point pollutants has been neglected; management focused on specific substances (biochemical oxygen demand (BOD) and total phosphorus (T-P)) and lacked specific cause analysis and action plans, failed to establish a relationship between water quality and pollution load, failed to reflect stakeholder demands for river water quality management, and failed to apply technical conditions. Therefore, to overcome the limitations raised and achieve a practical and efficient advanced total pollution system, the current system was partially improved and will continue to be improved. This study analyzed the performance and limitations of the total pollution system and introduced recent improvements and the contents that are being improved. The main contents included reducing emissions and reduction monitoring, using water quality tele-monitoring system (TMS) data and self-measurement data, adding population-inducing facilities, and adjusting regional development projects from 20 to 30 multi-family housing units, currentizing each pollutant source according to the roadmap. If the system is improved in a developmental direction and responds to various changes, it will be a more practical and effective policy.

A study on dissolved air flotation (DAF) process control using decision algorithm (의사결정 알고리즘을 이용한 DAF 공정 제어에 관한 연구)

  • Jung, Woosik;An, Ju-Suk;Park, Ji-Young;Oh, Hyun-Je
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.409-414
    • /
    • 2017
  • In this study, we divided the process operation scenarios into three categories based on raw water temperature and turbidity. We will select and operate the process operation scenario according to the characteristics of the raw water. The number of algae in the DAF treated water has been analyzed to be less than 100 cells/mL. These results indicated that the DAF process is effective in removing the algae. In addition, the scenario of the integrated management decision algorithm of the DAF process was developed. DAF pilot plants ($500m^3/day$) process has shown a constantly sound performance for the treatment of raw water, yielding a significantly low level of turbidity (DAF treated water, 0.21~1.56 NTU).