• 제목/요약/키워드: water environment

검색결과 13,287건 처리시간 0.04초

낙동강 백천 합류부 지점의 물환경측정망 대표성 검증 (Verification of Water Environment Network Representative at the Baekcheon Junction of the Nakdong River)

  • 안정민;임태효;김성민;김신;김경훈;권헌각;신동석;양득석
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.371-381
    • /
    • 2018
  • Multifunctional weirs constructed through the Four Major Rivers Restoration Project are operated as management water levels. The purpose of this study was to evaluate the effect of water level in the main stem on the tributary water level according to multifunctional weir operation, because the operation of multifunctional weirs for water level management influences the drainage of tributaries. In this study, water level pressure gauges were installed and spatial and temporal water quality was observed. The LOcally Weighted Scatterplot Smoothing (LOWESS) technique was applied to the Nakdong River and the Baekcheon Junction, both upstream of the Gangjeong-Goryeong weir, in order to analyze water quality trends. When considering the overall analysis and observations, it was found that the water quality forecasting point located at the Baekcheon estuary point should be transferred to the Dosung Bridge, which is located upstream of the Sunwon Bridge.

CE-QUAL-W2 모델을 이용한 임하호 선택배제시설의 효과분석 (Assessment of Selective Withdrawal Facility in the Imha Reservoir Using CE-QUAL-W2 Model)

  • 이상욱;김정곤;노준우;고익환
    • 한국물환경학회지
    • /
    • 제23권2호
    • /
    • pp.228-235
    • /
    • 2007
  • For efficient turbid water withdrawal in the Imha reservoir, a selective withdrawal facility was recently installed and operated during summer season of year 2006. In this research, CE-QUAL-W2 model was utilized to assess the efficiency of the selective withdrawal facility, in comparison with the original surface withdrawal, on turbid water management. Model calibration was carried out using data observed at four automatic monitoring stations in the reservoir. It was found that the model appropriately simulated, with the RMSE less than 5.2 NTU, the observed vertical and horizontal distributions of water temperature and turbidity as well as the location of maximum turbid water at each monitoring station. The analysis results showed that selective withdrawal is more effective in removing high turbid water than surface withdrawal as selective withdrawal contributed to reducing $35Mm^3$ of high turbidity water (> 100 NTU) in the reservoir by increasing outflows of high turbid water. Therefore, effective management of turbid water in the reservoir can be achieved by changing locations of intake depending on turbid water distribution conditions. The results of this study will provide some basic information for establishing better operation strategies to cope with turbid water problems.

물환경 종합평가의 현황과 선진화 방안 (Status and its Improvement of Comprehensive Water Quality Evaluation)

  • 최지용;이지현;이재관;김창수
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.748-756
    • /
    • 2006
  • Accurate and timely information on status and trends in the environment is necessary to shape sound water quality management policy and to implement water quality improvement programs efficiently. One of the most effective ways to communicate information on water quality trends to policy-makers, scientists, and the general public is with comprehensive water quality indices. The derivation and structure of a water quality index (WQI) for the classification of surface water quality is discussed. The WQI generally developed through the selection, transformation and weighting of determinants with rating curves based on legal standards and quality directives or guidelines. The representative pollutants should be included in the index, and the relationship between the quantity of these pollutants in the water and the resulting quality of the water should be based on scientific results. The WQI be simply and meaningfully formulated that nonscientifically trained users can easily become familiar with the framework of the system and use the output data to evaluate their own pollution problems.

다중회귀분석을 이용한 임하호 유입하천의 수온예측 (Water-Temperature Prediction of Streams Entering into Imha Reservoir using Multi-Regnssion Method)

  • 이용곤;이상욱;고덕구
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.919-925
    • /
    • 2006
  • The regression models for the water temperatures of Ban Byeon Stream and Yong Jeon stream were developed using multi-regression method. It was also investigated that the applicability of the stream temperature prediction to two-dimensional numerical simulation to predict the vertical water temperature in Imha Reservoir. Air temperature and dew point as independent variables were selected to be applicable to cases with the different variation of flow rates. The data division of water temperature using a cutoff flow rate of $20m^3/s$ was found to reduce the prediction error of the stream temperature. The mean absolute percent error of the numerical simulation results of the vertical water temperature in Imha Reservoir using the regression models was 11%, which was only 4.3% lager than the simulation result using the measured stream temperature. Therefore, the regression models of the stream temperatures using multi-regression method applied in this study could be applied to predict the vertical water temperature in Imha Reservoir with a good accuracy.

유역관리모형을 이용한 금강유역 유출특성 해석 (Analysis of Runoff Characteristics in the Geum River Basin using Watershed Management Model)

  • 류경식;황만하;맹승진;이상진
    • 한국물환경학회지
    • /
    • 제23권4호
    • /
    • pp.527-534
    • /
    • 2007
  • To operate scientifical and integrated management of water resources, it needs to identify clearly the quantitative variation and moving pathway of water resources in a basin. Moreover, it needs to also estimate more precisely the amount of runoff generating from the precipitation. Thus, in this study, to carry out more reliable hydrologic analyses, the runoff characteristics according to detailed runoff components and water balance in a basin are analyzed. As a result of yearly water balance analyses, during the period of drought year, the loss is bigger than that of 6-year mean loss and the return flow of groundwater is the most dominant component of runoff. During the period of flood year, the loss is smaller about 4% than that of 6-year mean loss and the subsurface water is the most dominant component of runoff. The loss due to the interception and evapotranspiration for 6-year mean loss is about 53% of the total rainfall, the mean runoff ratio is about 27% and the baseflow is about 22%.

초기우수 관거유입계수 산정 및 오염부하 기여도 평가 (Evaluation of First Flush Rainfall Inflow and Pollution Loads into Manhole against Combined and Sanitary Sewer Overflows)

  • 김홍태;신동석;김용석
    • 한국물환경학회지
    • /
    • 제31권1호
    • /
    • pp.67-70
    • /
    • 2015
  • Some data into combined and sanitary sewer system were collected in order to find out the characteristics of discharge from first flush rainfall inflow. The inflow ratios of combined and sanitary sewer system were 0.46 and 0.27 during rains from various survey data. The average inflow ratio 0.31 was appropriate for general application because many watersheds were not classified clearly as combined or sanitary sewage treatment areas. The percentage of first flush loads in the whole BOD load was about 10%. This result was thought some meaningful, comparing with similarity of first flush pollution load contribution previous surveyed by KECO (2004).

Organic Pollutant Transport in Unsaturated Porous Media by Atmospheric Breathing Processes( I ) - Partition Coefficient -

  • Ja-Kong;Lim, Jae-Shin;Do, Nam-Young
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1996년도 경북지부 결성 및 추계학술발표회 논문집
    • /
    • pp.50-53
    • /
    • 1996
  • This paper reports the experimental results for the determination of the overall partition coefficient of VOCs in unsaturated soil, A chromatographic method was used for the determination of gaseous partition coefficients to natural soil under various water content conditions. The equilibrium vapor pressure of water over saturated salt solution was used to fix the relative humidity of the air and control the water content of the soil systems. The transport behavior was studied for dichloromethane, trichloroethane and dichlorobenzene pollutants, with log octanol-water partition coefficients(log $K_{ow}$ ) which range from 1.25 to 3.39, or water to soil partitioning which varies by 135 times; water solubility constants which vary by 3 times; and vapor pressures which range from 1 to 362 torr. Water content of the soil had a pronounced effect on the effective partition coefficient(between gas and soil + water stationary phase) as well as on the effective dispersion coefficient.

  • PDF

갑천유역을 대상으로 SWAT 모형의 다 변수 및 다 지점 검.보정 (Multi-variable and Multi-site Calibration and Validation of SWAT for the Gap River Catchment)

  • 김정곤;손경호;노준우;장창래;고익환
    • 한국수자원학회논문집
    • /
    • 제39권10호
    • /
    • pp.867-880
    • /
    • 2006
  • 많은 수의 매개변수와 복잡한 구조를 가진 수문모형의 적용 시 세밀하고 강력한 모델 검 보정이 요구된다. 본 연구에서 금강유역에 위치한 갑천 소유역에 준 분포형 모형인 SWAT모형을 이용하여 다 목적 지점 검 보정 방법을 제시하였다. 모형의 보정 전 민감도 분석을 통한 각 소유역별로 특성 분석이 이루어 졌고, 유출에 민감한 매개변수들을 추정하였다. 그리고 최소한의 보정을 통한 모형의 유효성을 높이기 위해, 관측된 데이터로부터 매개변수 값을 선보정하는 과정을 거쳤다. 그 결과 각 소유역 별로 다른 매개변수들의 민감도가 나타났다. 관측유량에 대한 보정 단계에서 $R_{eff}$는 0.41-0.84, $R^2$은 0.5-0.86 값으로 신뢰성 있는 결과를 얻었다. Recursive digital filter로 추정된 기저 유출량을 약 2% 범위에서 산정하였다. 관측 지하수 수위와의 비교에서도 전체적으로 관측된 지하수 수위의 시간적 변동추이와 변동 폭을 잘 나타내었으며, $R^2$는 0.69로 만족스러운 결과를 보였다. 결론적으로, 다 목적 지점 방법의 사용은 모형기 구조와 추정된 매개변수들에 높은 신뢰도를 제공하였다.

SWAT 모델을 이용한 갑천유역에 대한 수문 특성 분석 및 도시화 영향 평가 (Evaluation of Urbanization Effect and Analysis of Hydrological Characteristics in the Gap River Catchment using SWAT)

  • 김정곤;손경호;노준우;장창래;고익환
    • 한국수자원학회논문집
    • /
    • 제39권10호
    • /
    • pp.881-890
    • /
    • 2006
  • SWAT 모형을 이용하여 대전 3대 하천 유역의 수문 분석 및 도시화에 따른 영향을 평가하였다. 물수지 분석결과에 의하면, 전체적으로 총 유출량 중 지하수 유출량이 44%정도, 중간 유출량이 6% 그리고 지표유출량이 50%이다. 도시화 영향 분석 결과 전체적으로 1975년에서 2000년까지 갑천유역의 약 5%가량의 도시화는 총 유출량의 변화에 있어서는 현저한 차이를 보이지 않았으나, 도시화 율이 32%정도 증가한 소유역의 경우 유출 성분 분석에서 첨두 유량의 경우 $25{\sim}66%$의 증가를 보였고, 지하수 유출량의 경우 $68{\sim}73%$의 감소를 확인 할 수 있었다. 그리고 도시화의 영향으로 토양수분량은 건기를 제외한 모든 시기동안 감소한 반면 침투량은 모든 시기동안 감소하였다. 도시화의 영향은 강우량이 적고, 증발량이 많은 갈수년에 더 크게 나타났다. 이 결과로부터 도시화의 영향으로 풍수기 동안의 홍수피해 폰가 및 갈수기 동안의 하천의 건천화 문제를 유추 할 수 있을 것이다. 결론적으로 본 연구에서 수행한 수문분석 및 도시화 영향분석 결과는 향후 대천 3대 하천의 생태하천복원을 위한 물순환 정상화 대책마련 및 하천의 유량확보방안 마련을 위한 기초자료로 사용될 수 있을 것이다.