• 제목/요약/키워드: water environment

검색결과 13,287건 처리시간 0.06초

수질오염총량관리제 시행에 따른 삽교호의 수질변화 예측 (Forecasting of changes in the water quality in Sapgyo-Lake in accordance with implementation of Total Water Pollutant Load Management System)

  • 김홍수;조병욱;박상현;이무규;김창기;최정호
    • 한국물환경학회지
    • /
    • 제35권3호
    • /
    • pp.209-223
    • /
    • 2019
  • Broadly speaking, in order to analyze the water quality improvement effects of the implementation of the Total Water Pollutant Management System in the Sapgy-Lake waterways, a reference was made to the [Plans for implementation of the Total Maximum Daily Load(TMDL)] in 3 cities (Cheonan, Asan, Dangjin). The results of the investigation into the plans to reduce the pollutant load show in that region show that there are plans to reduce pollution for a total of 16 reduction facilities. As for the result of the computation of the reduction in the load, these measurements were computed at the Gokgyo-stream basin and Namwon-stream basin, with BOD and T-P at the Gokgyo-stream basin reduced by 13.9 % and 13.3 %, respectively, while BOD and T-P at the Namwon-stream were reduced by 3.7 % and 3.3 %, respectively. In this way, thus using the results of the water quality forecast of Sapgyo-Lake in measures for the improvement of water quality (in accordance with the implementation of the TMDL), and using the QUAL-MEV model and EFDC model, it is noted that BOD will be improved by 26.4 % from 6.1 mg/L to 4.5 mg/L 0.0 %, T-P by 36.7 % from 0.168 mg/L to 0.107 mg/L and TOC by 26.4 % from 7.7 mg/L to 5.6 mg/L. However, it is forecasted that the targeted standards for the medium influence area will not be achieved. Evidently, Gokgyo-stream and Namwon-stream have been implementing the Total Water Pollutant Management System for the BOD items since January 1, 2019, but the Sapgyo-stream and Muhan-stream were excluded from being designated as subject regions. As such, it is noted now that it is necessary to implement the TMDL for the entire Sapgyo-Lake water systems including Sapgyo-stream and Muhan-stream in order to improve the water quality of Sapgyo-Lake, and likewise the T-P should be designated as the substance subjected to management in addition to BOD.

물 환경관리를 위한 불투수면 지표의 적용성 연구 (Applicability of Impervious Cover Index for Water Environment Management)

  • 최지용;김병익;박백수;정은성
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.767-772
    • /
    • 2008
  • Studies regarding the application of the impervious cover rate as a watershed management index have increased in number due to concerns over watershed management. The impervious cover rate is suggested as an index that can manage not only water quality but also water volume and the water ecosystem. This study intends to prove its applicability through the interconnection of the impervious cover rate and the water environment in Korea. Analysis of a selected watershed with reference to impervious cover rates showed that a watershed with an impervious cover rate of over 30% had a direct runoff in excess of 60% of precipitation, while a watershed with an impervious cover rate of 7% had a direct runoff of 39%. Watersheds with higher impervious cover rates were also found to have higher BOD, though different watersheds showed slightly different aspects in connection with BOD. Monitoring of benthic macroinvertebrates showed that species inhabiting clean water appear more frequently in areas with lower impervious cover rates than areas with higher impervious cover rates, and in mainstream areas, relatively larger numbers of species appeared in areas with lower impervious cover rates. This suggests that impervious cover rates can be appropriately used as an index for watershed management, as it effectively represents changes to the water environment.

하수관거 정비지역의 관거이송 유량 및 수질특성 변화 (Changes in Characteristics of Sewer Flow & Its Water Quality from the Sewer Rehabilitation Area)

  • 박준대;오승영;최윤호;김용석
    • 한국물환경학회지
    • /
    • 제31권2호
    • /
    • pp.196-208
    • /
    • 2015
  • This study analyzed the characteristics of sewer flow and its water quality, and investigated changes in the characteristics in three areas where the sewer rehabilitation projects have been carried out. In S1 area, the patterns of the flow became regular and the range of the fluctuation decreased after the sewer rehabilitation. The flow and its BOD concentration increased. The infiltration/inflow and exfiltration showed clear distinction before and after the sewer rehabilitation in this area. In S2 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased considerably after the sewer rehabilitation. Big decrement in stormwater inflow but small in exfiltration appeared in this area. In S3 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased in a small rate in this area.

소양댐 상류 유역 내 어류상의 시⋅공간 분포와 부유성 퇴적물 영향 (Spatio-temporal Distribution and Suspended Sediment Effects on Fish Flora in the Upper Basin of Soyang-Dam)

  • 유은진;안종호;이문환;전동진
    • 한국물환경학회지
    • /
    • 제39권4호
    • /
    • pp.329-342
    • /
    • 2023
  • Turbid water and suspended sediment (SS) load are having negative consequences such as water quality degradation and ecological damage, thus necessitating the establishment of management guidelines to reduce their impact. The present work investigates the spatio-temporal distribution of fish species and the effects of turbid water from 2011-2016 in the upper reaches of Soyang-Dam. The family Cyprinidae is the largest population in the study area, among which Zacco platypus and Zacco koreanus are the dominant species. The diversity of species is relatively abundant in the upper watershed, while the seasonal effect on the population distribution remains unclear. Using two main common components of the empirical orthogonal function (EOF) analysis, the distribution characteristics of 27 species at five survey sites are revealed. Zacco koreanus is found to be predominant at the upstream A-Naerincheon, while Zacco platypus and Rhinogobius brunneus are found to be predominant at the upstream B-Bukcheon. Disturbance of an aquatic ecosystem has a relatively greater impact in the downstream, as-compared to the upper area-the high proportion of forest area is decreased whereas that of agricultural and urbanized areas is increased. The patterns of representative species are changed according to the mid- to long-term effects of turbid water and SS. Accordingly, the significant correlation between the SS load and fish distribution EOF analysis indicates that it should be considered as a potential alternative that can overcome the limitations of impact assessment on turbid water to the Fish Assessment Index (FAI). A comprehensive study examining the long-term effects of SS load to the fish ecosystems with a systematic statistical analysis of sufficiently accumulated data at the national level is needed as future research.

공동주택 지하저수조 내 침전된 부유성 고형물의 발생원인 및 제어방안 (Investigating the Causes and Control Measures for Precipitated Suspended Solids in the Underground Reservoir Tank in an Apartment)

  • 장준영;김주원;김기팔;신현상;임병란
    • 한국물환경학회지
    • /
    • 제39권2호
    • /
    • pp.153-161
    • /
    • 2023
  • The reservoir tank in an apartment is crucial for maintaining the quality of drinking water after it has undergone treatment. Investigating the water quality and potential contaminants in the reservoir tank is essential to ensure the safety of the drinking water. This study examined the water quality and precipitated suspended solids that accumulate at the bottom of the reservoir tanks in four apartments located in Gyeonggi province. As a result of the water quality investigation, turbidity increased proportionally to the distance from the water treatment plant (WTP) to the household. Heavy metals were also detected in the reservoir tank inlet but not in the water supplied from the WTP. The precipitated suspended solids (SS) in the reservoir tank contain high levels of heavy metals and total organic carbon (TOC). The precipitated SS mainly consists of Al, Mn, and Fe, which are expected to be a combination with turbidity-inducing substances. The X-ray diffraction (XRD) analysis revealed the presence of γ-FeO(OH), MnO2, and β-Fe2O3 in the SS. Additionally, F-EEM analysis indicates that the dissolved organic matter in the SS is mainly derived from a natural water source and microorganism activities, including metal-oxidizing bacteria and biofilms that can absorb metal ions. Based on these findings, several countermeasures can be taken to prevent the inflow of SS into the household, including regularly cleaning the reservoir tank, replacing or cleaning old pipes in the water supply system, and implementing monitoring and filtering systems to manage the SS.

Marine Environmental Change Due to Waterfront Development

  • Lee, Moon-Ock;Lee, Sam-No
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제3권1호
    • /
    • pp.33-39
    • /
    • 1999
  • A two-dimensional numerical experiment and field observations were conducted to evaluate changes in sea water movement and the water quality environment related to comprehensive projects of waterfront development around Kwangyang Bay on the south coast of Korea. Tidal flow velocities, especially in the western part of the bay, were considerably slower as a result of the development projects. Accordingly, the seawater exchange ratio reduced from 38.7% to 26.3%. The impact of dredging work on the water quality environment was much stronger than expected. Furthermore, after the completion of the industrial parks and container-exclusive wharfs, COD from the waste water treatment plant will be dispersed extensively into the adjacent water at a level of less than 0.1 mg/l for up to 142.5 $\textrm{km}^2$. Therefore, consistent monitoring and management of the water quality environment is strongly recommended.

  • PDF

염수환경을 고려한 섬유강화 복합재의 내구성 평가 (Durability of Fiber Reinforced Composites under Salt Water Environments)

  • 윤성호;황영은
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.391-396
    • /
    • 2005
  • Salt water spray test and salt water immersion test were experimentally conducted in order to investigate the durability of fiber reinforced composites under salt water environment. The specimens were made of glass fabric reinforcement and phenolic resin. Mechanical test was performed to obtain mechanical properties such as tensile properties, flexural properties, and shear properties by varying with exposure times. Also dynamic mechanical test and FTIR were conducted to investigate a change in chemical structure as well as thermal analysis properties such as storage shear modulus, loss shear moduls, and tan ${\delta}$. According to the results, salt water environment has effected on mechanical properties and thermal analysis properties and especially the durability of glass fabric/phenolic composites were severely affected on salt water immersion environment rather than salt water spray environment.

  • PDF

Evaluatinon of the Surface Water in Southwest Area of Vietnam

  • Thai, Thanh Luom
    • 환경영향평가
    • /
    • 제18권6호
    • /
    • pp.445-452
    • /
    • 2009
  • This study surveys the surface water environment in Southwest sea areas of Vietnam in order to evaluate the current environment. It collects and analyzes experimental results of programs, scientific subjects, and international projects relevant to ecological areas and coastlines of Kien Giang province. The methods analyzed and discussed by specialists are evaluated according to pollution coefficients established by the World Health Organization (WHO), sampling methods, and case study analyses. Comparison between the scale of pollution levels and the surface water quality in experimental areas of Long Xuyen Quadrangle shows a light-moderate pollution level. In Ca Mau Peninsula, the surface water source is only slightly polluted. Sea areas and islands are also light-moderately polluted. Computing results from water quality indices (WQI) show the level of pollution in experimental sites. Activities such as constructing infrastructures for tourism, exploiting minerals, and increasing population accelerate environmental pollution by deteriorating inherently sensitive ecosystems like corals, sea grass, mangrove swamps, and Melaleuca forests. Surveying and evaluating the present situation of surface water are fundamental solutions for environmental protection in the Southwest sea areas of Vietnam.

대형건축물 저수조의 수질실태 및 개선방안에 관한 연구 (A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area)

  • 이지헌;이해훈;김환범;안길원;박귀님;김양기;배주순;문희;박철웅;오은하;박송인;서윤규
    • 환경위생공학
    • /
    • 제15권4호
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

금호강 유역의 대장균 부하지속곡선 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geumho River)

  • 정강영;임태효;김경훈;이인정;윤종수;허성남
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.890-895
    • /
    • 2012
  • Duration curves describe the percentage of time that a certain water quality (total/fecal coliform (=TC/FC)) or discharge is exceeded. The curves methodology are usually based on daily records and are useful in estimating how many days per year and event will be exceeded. The technique was further applied to estimated TC/FC loading to the Geumho River, using the daily mean flow rate and TC/FC concentration data during January, 2001 and December, 2011 for the Geumhogang6 (=Seongseo water level station) where an automated monitoring station is located in Gangchang-bridge. Low flow of the Seongseo (=11.1 cms) was equivalent to 75.3% on an exceedance probability scale. Load Duration curve for TC/FC loading at the Seongseo was constructed. Standard load duration curve was constructed with the water quality criteria for class III (TC/FC concentration = 5000/1000 CFU/ 100 mL). By plotting TC/FC observed load duration curve with standard load duration curve, it could be revealed that water quality do not meet the desired water quality for 68.8/11.2% on an exceedance probability scale. IF linear correlation between flow rate and coliform concentration is assumed, it can be interpreted that water quality exceed desired criteria when daily average flow rate is over 11.9/109.9 cms.