• Title/Summary/Keyword: water drawdown

Search Result 132, Processing Time 0.023 seconds

Case Study of Characteristic of Ground Deformation and Strut Axial Force Change in Long Span Deep Excavation(II) (장지간 깊은 굴착에서 지반변형 및 버팀보 축력변화 특성 사례연구(II))

  • Kim, Sung-Wook;Han, Byung-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.248-259
    • /
    • 2010
  • In the case of relatively good ground and construction condition in the deep excavation for the construction of subway, railway, building etc., flexible earth retaining systems are often used in an economical point of view. It is generally known that the mechanism of behavior in the flexible earth retaining system is relatively more complicated than the rigid earth retaining system. Moreover in the case of long span strut supporting system the analysis of strut axial force change becomes more difficult when the differences of ground condition and excavation work progress on both sides of excavation section are added. When deeper excavation than the specification or installation delay of supporting system is done or change of ground condition is faced due to the construction conditions during construction process, lots of axial force can be induced in some struts and that can threaten the safety of construction. This paper introduces one example of long span deep excavation where struts and rock bolts were used as a supporting system with flexible wall structure. The characteristics of ground deformation and strut axial force change, the measured data obtained during construction process, were analysed, the effects of relatively deeper excavation than the specification on one excavation side and rapid drawdown of ground water level on the other excavation side were deeply investigated from the viewpoint of mutual influences between ground deformations of both excavation sides and strut axial force changes. The effort of this article aims to improve and develop the technique of design and construction in the coming projects having similar ground condition and supporting method.

  • PDF

Groundwater Analysis for Jun Stream Basin in Donghae City using MODFLOW (MODFLOW를 이용한 동해시 전천유역의 지하수분석)

  • Kim, Sam Eun;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.342-351
    • /
    • 2021
  • The objective of this study is to evaluate the change of groundwater and its effect to hydraulic head or parameter sensitivity in order to predict the effect of a new groundwater well using MODFLOW. With the downstream area of the Jun stream basin in the Donghae city, two condition were simulated; (i) First simulation condition is to simulate natural steady-state and the groundwater heads for observation wells are calibrated. After the calibration, existing wells are simulated to find out the pure effect of the next simulation condition, (ii) Secondly, the design wells are planed and simulated for the solution of water shortage problem at Donghae city. As a result of the simulation, the maximum drawdown which is approximately 0.35m occurs in layer 1. This represents that there is no intrusion of salty water and the design plan is acceptable. Finally, the sensitivity analysis of each parameter in MODFLOW is accomplished. We found out that the sensitive parameters are initial head, anisotropic factor, hydraulic conductivity, and general head boundary

Application of the Artificial Recharge to Reduce the Ground-water Drawdown of the River Bank Filtration (강변여과수 취수시 과도한 지하수 하강을 저감시키기 위한 인공함양의 활용 방안)

  • Lee, Dong Kee;Park, Jae Hyeoun;Park, Chang Kun;Kim, Sang Jun;Nam, DoHyeoun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.236-240
    • /
    • 2004
  • 강변여과수의 과도한 취수는 제내지 지하수위 하강을 발생하게 되며 이로 인해서 제내지 농경지의 토양 건조도가 증가되어 과도한 관계용수의 보충이 필요할 뿐말 아니라 지하수위 하강으로 인한 기존 관정사용이 어려워져 더 깊은 새로운 관정을 개발해야만 한다.. 이러한 기하수위 하강을 저감시키기 위한 방안으로 제내 지측에 인공함양우물을 설치하는 방법 있다. 창원시 강변여과 시설에 적용한 결과 인공함양우물의 최적 위치는 취수정으로부터 세내지 측으로 200m 지점에 위치하며, 함양량을 취수량의 $5\%$를 유지하는 것이 지하수위를 저감하기위한 효과적인 조건으로 판단되었다.

  • PDF

Analysis of long-term water level change of Dongrae hot spring using time series methods (시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Lee, Cheol-Woo;Lee, Jong-Tae;Lim, Woo-Ri
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.529-544
    • /
    • 2018
  • Dongrae hot spring belongs to the residual magma type and has a long history of bathing since the Silla dynasty in Korea. Due to long development of hot spring water, it is expected that the amount of hot spring water in Dongrae hot spring has been changed. In this study, long-trem water level data of Dongrae hot spring were examined for recognizing the change of the hot spring. By the fluctuation analysis of the hot spring water level from January 1992 to July 2018, the maximum and minimum annual drawdowns of no. 27 well were 137.70 and 71.60 meters, respectively, with an average drawdown of 103.39 m. On the other hand, the maximum and minimum annual drawdowns of no. 29 well were 137.80 and 71.70 meters, with an average drawdown of 103.49 m. Besides, drawdown rate became bigger in recent years. As a result of analyzing autocorrelation of the two wells, the correlation coefficient ranged from 0.919 to 0.991, showing seasonal groundwater level fluctuation. The cross correlation analysis between water level and precipitation as well as water level and hot spring discharge resulted in the correlation coefficients of -0.280 ~ 0.256 and 0.428 ~ 0.553, respectively. Therefore, using Dongnae hot-spring water level data from 1992 to 2018, the Mann-Kendall test and Sen's test showed that the continuous decline of water level was mainly caused by the pumping of the hot spring water among various reasons.

An Experimental Study of Ground Water Source Two Well Type Geothermal Heat Pump System (지하수 열원 복수정 지열 열펌프 시스템의 성능에 관한 실험적 연구)

  • Lim, Hyo-Jae;Kwon, Jeong-Tae;Kim, Chang-Eob;Kong, Hyoung-Jin;Park, Seong-Koo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.468-474
    • /
    • 2009
  • Ground water source heat pump system is the oldest one of the ground source heat pump systems. Despite of this, little formal design information has been available until recently. The important design parameters for open system are the identification of optimum ground water flow, heat exchanger selection and well pump. In this study, the capacity of 50 RT system of two well type ground water heat pump system was used. As a result, static water level was -7 m and the level during the heating operation was -32 m, cooling operation was -40 m. The initial static water level recovered within 48 hrs. The temperature of ground water is $15.6^{\circ}C$ for heating season and $16.2^{\circ}C$ for cooling season and does not depend on the outdoor temperature. Operation efficiency of the system shows that, COP 3.1 for heating and COP 4.2 for cooling.

Analytical Evaluation of Interference and Ratio of River Water at Riverbank Filtration Pumping Wells (강변여과 취수정의 간섭효과와 하천수 비율에 대한 해석적 평가)

  • Park, Namsik
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.8
    • /
    • pp.685-691
    • /
    • 2014
  • River bank filtration techniques seek to improve river water quality via natural processes occurring when river water is induced to a river bank. When water is pumped from multiple wells, phenomenon known as well interference affect pumping rates. Pumping wells of a bank filtration facility are connected by pipelines. In theses cases well interference is caused not only by groundwater drawdown but also by pipe headloss which depend on flow rates. In this work a comprehensive analytical method which handles groundwater flow and pipe flow is used to evaluate interferences and ratios of river water in pumping wells. A realistic case was used as an example.

Value of Ensemble Streamflow Forecasts for Reservoir Operations during the Drawdown Period (이수기 저수지 운영을 위한 앙상블 유량예측의 효용성)

  • Eum, Hyung-Il;Ko, Ick-Hwan;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.3 s.164
    • /
    • pp.187-198
    • /
    • 2006
  • Korea Water Resources Corporation(KOWACO) has developed the Integrated Real-time Water Management System(IRWMS) that calculates monthly optimal ending target storages by using Sampling Stochastic Dynamic Programming(SSDP) with Ensemble Streamflow Prediction(ESP) running on the $1^{st}$ day of each month. This system, however, has a shortcoming: it cannot reflect the hydrolmeteorologic variations in the middle of the month. To overcome this drawback, in this study updated ESP forecasts three times each month by using the observed precipitation series from the $1^{st}$ day of the month to the forecast day and the historical precipitation ensemble for the remaining days. The improved accuracy and its effect on the reservoir operations were quantified as a result. SSDP/ESP21 that reflects within-a-month hydrolmeteorologic states saves $1\;X\;10^6\;m^3$ in water shortage on average than SSDP/ESP01. In addition, the simulation result demonstrated that the effect of ESP accuracy on the reduction of water shortage became more important when the total runoff was low during the drawdown period.

The Analysis of the Slope Stability in Embankment(I) (제체의 사면안정 해석(I))

  • 최기봉
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.134-142
    • /
    • 1997
  • The stability of an embankment Impounding a water reservoir is highly depend upon the location of seepage line with the embankment. To evaluate the accurate safety factor of an embankment, it is important to illustrate the seepage phenomenon. Of particular interest is the stability following a rapid change (drawdown) of reservoir level Seepage forces in embankments are easily determined if frictional forces are expressed in relation to hydraulic gradient Ⅰ. If a piezometer is inserted into a body of embankment, the level to which free water rises is a measure of the energy at that point. From model test result, it is possible to calculate safety factors of earth embankment. To assure the validity of this research, tests were conducted with numerical experimental models. And the experiment models were constructed with slopes of 1:1.0, 1:1.5, 1:2.0, 1:2.5. Analysis of experimental results, seepage force was analyzed according to downstream time, internal friction angle and cohesion, respectively.

  • PDF

A Study of Unsteady Seepage in Embankments for a Parallel Water Flow (제체(堤體)의 평행(平行)흐름에 대한 비정상침투(非正常浸透) 연구(研究))

  • Shin, Bang Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.8 no.3
    • /
    • pp.101-111
    • /
    • 1988
  • This thesis investigated the variation of the seepage line of earth structure when the water level rises and drawdowns and compare this with the hither to published formula. And, analysised by a vector in embankment model's seepage velocity of followed rises and drawdowns. And, by the experimental method find difference point per follow drawdown and rises in the same model.

  • PDF

Ground Deformation involving drawdown of the water table in deep excavation - Numerical Investigation (지하굴착시 지하수저하에 따른 지반침하 - 수치해석 연구)

  • Choi, Go-Ny;Yoo, Chung-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.13-20
    • /
    • 2010
  • This paper presents the results of a numerical investigation on the ground deformation in deep excavation with emphasis on the groundwater lowering. Using the stress-pore pressure coupled analysis Consideration to the effect of ground excavation and groundwater interaction were carried out and a series of two-dimensional finite element model was employed to perform a parametric study on a wide range of soil profile and initial ground water table condition.

  • PDF