• Title/Summary/Keyword: water distribution system reliability

Search Result 75, Processing Time 0.035 seconds

A Study on Standardization of the Electric Facilities for distribution & Translations - Focused on the Electric Facilities in Subway Stations - (수변전설비의 표준화에 관한 연구 - 지하철 역사전기설비를 중심으로 -)

  • Cho, Sung-Pil;Kang, Cha-Nyeong;Kim, Hak-Lyun
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.838-843
    • /
    • 2006
  • In our modern society, such electric facilities as lighting, elevators, water supplies, drainages, waste water treatments and landscape lighting are being more enlarged, diversified and technology-intensive owing to outstanding technological development, while they require reliable and safe electricity. On the other hand, as more electric energy is consumed with more complicated systems operated, any accident from a personal electric system is likely to have wider spreading effects. In particular, the electric receivers and transformers installed for such public facilities as subway stations require highest safety, reliability and economy, but such requirements tend to be less considered than such financial requirements as budget conditions, much less their safety and reliability. In such a circumstance, this study was aimed at suggesting some standards for safe, reliable and economic subway electric systems in terms of their scale, location and uses. Specifically, this study put forwards the ways to optimize and standardize the electric systems including receivers and transformers for subway stations in order to make them safer, more reliable and economic.

  • PDF

Distributed control system architecture for deep submergence rescue vehicles

  • Sun, Yushan;Ran, Xiangrui;Zhang, Guocheng;Wu, Fanyu;Du, Chengrong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.274-284
    • /
    • 2019
  • The control architectures of Chuan Suo (CS) deep submergence rescue vehicle are introduced. The hardware and software architectures are also discussed. The hardware part adopts a distributed control system composed of surface and underwater nodes. A computer is used as a surface control machine. Underwater equipment is based on a multi-board-embedded industrial computer with PC104 BUS, which contains IO, A/D, D/A, eight-channel serial, and power boards. The hardware and software parts complete data transmission through optical fibers. The software part involves an IPC of embedded Vxworks real-time operating system, upon which the operation of I/O, A/D, and D/A boards and serial ports is based on; this setup improves the real-time manipulation. The information flow is controlled by the software part, and the thrust distribution is introduced. A submergence vehicle heeling control method based on ballast water tank regulation is introduced to meet the special heeling requirements of the submergence rescue vehicle during docking. Finally, the feasibility and reliability of the entire system are verified by a pool test.

A new approach to design isolation valve system to prevent unexpected water quality failures (수질사고 예방형 상수도 관망 밸브 시스템 설계)

  • Park, Kyeongjin;Shin, Geumchae;Lee, Seungyub
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1211-1222
    • /
    • 2022
  • Abnormal condition inevitably occurs during operation of water distribution system (WDS) and requires the isolation of certain areas using isolation valves. In general, the determination of the optimal location of isolation valves considered minimization of hydraulic failures as isolation of certain areas causes a change in hydraulic states (e.g., flow direction, velocity, pressure, etc.). Water quality failure can also be induced by changes in hydraulics, which have not been considered for isolation valve system design. Therefore, this study proposes a new isolation valve system design methodology to prevent unexpected water quality failure events. The new methodology considers flow direction change ratio (FDCR), which accounts for flow direction changes after isolation of the area, as a constraint while reliability is used as the objective function. The optimal design model has been applied to a synthetic grid network and the results are compared with the traditional design approach. Results show that considering FDCR can eliminate flow direction changes while average pressure and coefficient of variation of pressure, velocity, and hydraulic geodesic index (HGI) outperform compared to the traditional design approach. The proposed methodology is expected to be a useful approach to minimizing unexpected consequences by traditional design approaches.

Development of Smart Remote Terminal Unit for Water Treatment SCADA System (상하수도 원격감시제어 시스템 구현을 위한 스마트 RTU의 개발 및 적용)

  • Jang, Sang-Bok;Lee, Ho-Hyun;Hong, Sung-Taek;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.24-30
    • /
    • 2014
  • In this paper, a new remote terminal unit(hereafter RTU) is proposed to manage a wide range of applications and a variety of sensors (eg, pressure, water quality, temperature and humidity sensors, the amount of pollutants, $CO_2$, etc.) to monitor and control the facility such as water treatment plant, intake and effluent pumping station, water tank and distribution network. Fault status of local sensor devices and network are alerted by using the embedded fault handling capabilities of the RTU in the system and also sent to the fault handling server, by which fault can be easily monitored to users. The developed system was applied to one of K-water branch offices in Geoje city and improved its reliability and stability for controlling and monitoring water facility.

Optimum design of direct spring loaded pressure relief valve in water distribution system using multi-objective genetic algorithm (다목적 유전자 알고리즘을 이용한 상수관망에서 스프링 서지 완화 밸브의 최적화)

  • Kim, Hyunjun;Baek, Dawon;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.115-122
    • /
    • 2018
  • Direct spring loaded pressure relief valve(DSLPRV) is a safety valve to relax surge pressure of the pipeline system. DSLPRV is one of widely used safety valves for its simplicity and efficiency. However, instability of the DSLPRV can caused by various reasons such as insufficient valve volume, natural vibration of the spring, etc. In order to improve reliability of DSLPRV, proper selection of design factors of DSLPRV is important. In this study, methodology for selecting design factors for DSLPRV was proposed. Dynamics of the DSLPRV disk was integrated into conventional 1D surge pressure analysis. Multi-objective genetic algorithm was also used to search optimum design factors for DSLPRV.

Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law (Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지)

  • Youn, Byeng D.;Jang, Beom-Chan;Kim, Hee-Soo;Bae, Yong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

Spatial distribution and uncertainty of daily rainfall for return level using hierarchical Bayesian modeling combined with climate and geographical information (기후정보와 지리정보를 결합한 계층적 베이지안 모델링을 이용한 재현기간별 일 강우량의 공간 분포 및 불확실성)

  • Lee, Jeonghoon;Lee, Okjeong;Seo, Jiyu;Kim, Sangdan
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.10
    • /
    • pp.747-757
    • /
    • 2021
  • Quantification of extreme rainfall is very important in establishing a flood protection plan, and a general measure of extreme rainfall is expressed as an T-year return level. In this study, a method was proposed for quantifying spatial distribution and uncertainty of daily rainfall depths with various return periods using a hierarchical Bayesian model combined with climate and geographical information, and was applied to the Seoul-Incheon-Gyeonggi region. The annual maximum daily rainfall depth of six automated synoptic observing system weather stations of the Korea Meteorological Administration in the study area was fitted to the generalized extreme value distribution. The applicability and reliability of the proposed method were investigated by comparing daily rainfall quantiles for various return levels derived from the at-site frequency analysis and the regional frequency analysis based on the index flood method. The uncertainty of the regional frequency analysis based on the index flood method was found to be the greatest at all stations and all return levels, and it was confirmed that the reliability of the regional frequency analysis based on the hierarchical Bayesian model was the highest. The proposed method can be used to generate the rainfall quantile maps for various return levels in the Seoul-Incheon-Gyeonggi region and other regions with similar spatial sizes.

1-D Modeling of Heater Surface Temperature Distribution in EHC-based Urea-SCR System (EHC 기반 Urea-SCR 시스템 히터 표면온도 분포의 1-D 모델링)

  • Park, Sunhong;Son, Jihyun;Moon, Seoksu;Oh, Kwangchul;Jang, Sungwook;Park, Sungsuh
    • Journal of ILASS-Korea
    • /
    • v.27 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • In upcoming Post Stage-V and Tier 5 regulations of construction machineries, nitrogen oxide (NOx) emissions are strictly limited in cold start conditions. In response to this, a method of improving NOx conversion efficiency has been applied by installing an electric heating catalyst (EHC) in front of conventional urea-SCR systems so that the evaporation and thermal decomposition of urea-water solution can be promoted in cold start conditions. In this strategy, the evaporation and thermal decomposition of urea-water solution and corresponding NOx conversion efficiency are governed by temperature conditions inside the EHC. Therefore, characterizing the temperature distribution in the EHC under various operating conditions is crucial for the optimized operation and control of the EHC in Urea-SCR systems. In this study, a 1-D modeling analysis was performed to predict the heater surface temperature distribution in EHC under various operating conditions. The reliability of prediction results was verified by comparing them with measurement results obtained using an infrared (IR) camera. Based on 1-D analysis results, the effects of various EHC operation parameters on the heater surface temperature distribution were analyzed and discussed.

Development and Application of Reliability Index based on Hydraulic Uniformity in Water Distribution Networks (상수관망의 수리학적 균등성을 이용한 신뢰도 지표의 개발 및 적용)

  • Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.6-6
    • /
    • 2019
  • 상수관망시스템은 공급원으로부터 수요처까지의 용수공급을 위해 구축된 관수로 기반의 사회기반시설물로서, 주로 생활 및 산업 용수를 공급하므로 대규모 사회 경제적 피해를 방지하기 위해서는 안정적인 용수공급 능력이 요구된다. 네트워크의 다양한 특성에 의해 표현되는 상수관망시스템의 신뢰도(reliability)는 크게 시스템 내 구성요소의 안정성(mechanical reliability)과 용수공급의 기능적 안정성(hydraulic reliability)으로 구분할 수 있다. 특히, 시스템의 용수공급 안정성에 주목한 수리학적 신뢰도 연구는 많은 연구자들에 의해 지속적으로 수행된 바 있으며, 다양한 평가방법 및 지표들이 제시되어 활용 중에 있다. 기존의 수리학적 신뢰도 지표들은 주로 수요절점(demand node)에서의 공급가능 수량 및 수압을 바탕으로 산정되었다. 그러나, 절점(node)에서의 공급 상태는 결과에 해당하며, 원인 분석을 위해서는 관로(pipe)의 배치 및 규격을 분석해야 하는 번거로움이 존재한다. 이러한 단점을 보완하기 위해, 본 연구에서는 직접 관로(pipe)의 공급 특성을 분석하여 네트워크의 신뢰도를 평가함으로써, 신뢰도 저하의 원인 분석 및 시스템 개선에 효율적으로 활용할 수 있는 신뢰도 지표를 산정하고자 하였다. 본 연구에서는 상수관로 내 수리학적 기울기가 전반적으로 균등할수록 설계 비용대비 공급 신뢰도, 즉 용수공급 효율이 개선되는 특징을 바탕으로, 네트워크 내 총 에너지 손실로부터 각 관로의 길이, 유량 등의 특성을 고려한 등가 수리경사(Equivalent hydraulic gradient)를 유도하여 모든 관로의 적정 수리경사로 제안하였다. 따라서 각 관로의 실제 수리경사를 대상으로 관로별 수리학적 균등성 지수(pipe hydraulic uniformity index)를 산정하였으며, 더 나아가 전체 시스템의 균등성 지수(system hydraulic uniformity index)를 산정하였다. 제안된 신뢰도 지표는 가상의 네트워크에서 지역 내 용수 사용량이 증가하는 등 용수공급 안정성을 저해하는 몇 가지 시나리오를 바탕으로 검증하였으며, 또한 기존 지표들의 신뢰도 평가 결과와 비교, 분석하였다. 본 연구는 향후 네트워크 최적 설계의 목적함수로 활용하거나, 네트워크의 보강계획 수립에 기여할 것으로 기대된다.

  • PDF

Optimal Design of Irrigation Pipe Network with Multiple Sources

  • Lyu, Heui-Jeong;Ahn, Tae-Jin
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.2
    • /
    • pp.9-18
    • /
    • 1997
  • Abstract This paper presents a heuristic method for optimal design of water distribution system with multiple sources and potential links. In multiple source pipe network, supply rate at each source node affects the total cost of the system because supply rates are not uniquely determined. The Linear Minimum Cost Flow (LMCF) model may be used to a large scale pipe network with multiple sources to determine supply rate at each source node. In this study the heuristic method based on the LMCF is suggested to determine supply rate at each source node and then to optimize the given layout. The heuristic method in turn perturbs links in the longest path of the network to obtain the supply rates which make the optimal design of the pipe network. Once the best tree network is obtained, the frequency count of reconnecting links by considering link failure is in turn applied to form loop to enhance the reliability of the best tree network. A sample pipe network is employed to test the proposed method. The results show that the proposed method can yield a lower cost design than the LMCF alone and that the proposed method can be efficiently used to design irrigation systems or rural water distribution systems.

  • PDF