• 제목/요약/키워드: water cooling tube

검색결과 196건 처리시간 0.024초

지하수정호와 결합한 복합지열시스템의 열교환 효율에 대한 실험적 연구 (Experimental Study on Heat Exchange Efficiency of Combined Well & Open-Closed Loops Geothermal System)

  • 송재용;이근춘;박남서
    • 대한건축학회논문집:구조계
    • /
    • 제34권5호
    • /
    • pp.43-50
    • /
    • 2018
  • The temperature of underground water generally remains constant regardless of the season. therefore, it is possible to get plenty of energy if we use characteristics of underground water for both cooling and heating. This study evaluates efficiency of real size coaxial and U-tube type complex geothermal system which is combined with underground water well. This study also evaluates relative efficiency/adaptability through comparison with existing geothermal systems(vertical closed loop system, open loop system(SCW)). The heat exchange capacity of complex geothermal system according to temperature difference between circulating water and underground water shows very high significance by increasing proportionally. The temperature change of underground water according to injection energy, shows very high linear growth aspect as injection thermal volume heightens. As a result of evaluation of heat exchange volume between complex geothermal system and comparative geothermal system, coaxial type has 26.1 times greater efficiency than comparative vertical closed type and 2.8 times greater efficiency than SCW type. U-tube type has 26.5 tims greater efficiency than comparative vertical closed type and 2.8 times greater than SCW type as well. This means complex geothermal system has extremely outstanding performance.

다관원통형 열교환기의 파울링 해석기법 개발 연구 (A Study on the Development of Fouling Analysis Technique for Shell-and-Tube Heat Exchangers)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권2호
    • /
    • pp.167-173
    • /
    • 2004
  • Fouling of heat exchangers is generated by water-borne deposits, commonly known as foulants including particulate matter from the air, migrated corrosion produces; silt, clays, and sand suspended in water; organic contaminants; and boron based deposits in plants. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. This paper describes the fouling analysis technique developed in this study which can analyze the thermal performance for heat exchangers and estimate the future fouling variations. To develop the fouling analysis technique fur heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose or verifying the fouling analysis technique, the routing analyses were performed for four heat exchangers in several nuclear power plants; two residual heat removal heat exchangers of the residual heat removal system and two component cooling water heat exchangers of the component cooling water system.

마이크로휜관 내 단상 냉각 유동 열전달 및 압력 강하 특성에 관한 실험적 연구 (Experiments on Single Phase Cooling Heat Transfer and Pressure Drop Characteristics in Microfin Tubes)

  • 이규정;한동혁
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.231-239
    • /
    • 2002
  • Experiments on the single phase cooling heat transfer and pressure drop with microfin tubes were performed using water as a test fluid. Experimental data were obtained in the range of Reynolds number 3000 ~40000 and Prandtl number 4-6. The data of microfin tubes presented the characteristics of rough surface tube in pressure drop and heat transfer Experimental data were compared with the heat transfer and friction factor correlations of smooth tubes. Heat transfer enhancements of microfin tubes were lower than pressure drop penalty factors. The helix angle is more significant parameter in both of the pressure drop and heat transfer than the relative roughness. The correlations of Nusselt number and friction factor were suggested for the tested microfin tubes. Maximum deviations between correlations and experimental data were within $\pm15$% for Nusselt number and $\pm10$% for friction factor.

공냉식 수직 흡수기의 열전달에 미치는 계면활성제의 영향 (Influence of surfactant on heat transfer of air-cooled vertical absorber)

  • 윤정인;권오경;문춘근
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.740-748
    • /
    • 1999
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different vertical tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare inner surface, groove inner surface, corrugated inner surface and spring inserted inner surface tubes. The additive concentration was about 0.08 mass%. The heat transfer coefficient was measured as a function of film Reynolds number in the range of 20~200. Experiments were tarried out at higher cooling water temperature of $35^{\circ}C$ to simulate an air cooling condition for several kinds of absorber testing tubes. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect which was generated by addition of the surfactant is observed in each test tube. Especially, it is clarified that the tube with an inserted spring has the highest enhancement effect.

  • PDF

물-공기 지열 멀티형 열펌프 시스템 실증연구 (Verification Experiment of a Water-to-air Ground Source Multi-heat Pump System)

  • 김철우;김병국;이평강;임효재;강신형;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2010
  • The aim of this study is to verify the performance of water-to-air multi-heat pump system with a vertical U-tube GLHX(U-tube system) and a double tube GLHX(double tube system), which were installed in a school building located in Asan. For analyzing the performance of the GSHP system, we monitored various operating da~ including the water temperature of inlet and outlet of the ground heat exchanger, mass flow rate, and power consumption. Daily average COP of the single U-tube system and the double tube system were 4.5 and 4.2 at cooling mode and were 3.5 and 3.8 at heating mode. As a result, We know that performance of water-to-air multi-heat pump unit is reliable at actual condition operated in a part load conditions for all day.

흡착식 냉동기의 흡착탑에서 열 및 물질전달에 관한 수치적 연구 (A Numerical Study for the Heat and Mass Transfer in Silica gel/Water Adsorption Chiller's Adsorber)

  • 권오경;윤재호;김종하;김용찬;주영주
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.341-346
    • /
    • 2005
  • Nowadays, adsorption chillers have been receiving considerable attentions as they are energy-saving and environmental1y benign systems. A Fin & tube type heat exchanger in which adsorption/desorption take place is required more compact size. The adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objectives of this paper are to investigate the effect of fin pitch of fin & tube on the adsorption performance and to develop an optimal design fin & tube heat exchanger in the silica gel/water adsorption chiller. Previous study concluded that optimal particle size selected 0.5mm, type HO silica gel, and fundamental heat transfer & mass transfer experiments carried out. From the numerical results, the adsorption rate for the fin pitch 2.5mm is the highest than that for the fin pitch 5mm, 7.5mm and 10mm. Also cooling water & hot water temperature affect the adsorption rate.

  • PDF

가정용 보일러의 급탕시설 개선방안에 관한 연구 (A Study on the Improvement of the Water System in Domestic Boiler)

  • 한규일;박종운
    • 수산해양기술연구
    • /
    • 제34권2호
    • /
    • pp.200-211
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성 (Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube)

  • 유태근;김대희;손창효;오후규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF

PEFP DTL 가속장치의 공진주파수 제어를 위한 펌프장치의 설계 및 성능에 관한 연구 (A Study on the Design and Performance of a Prototype Pumping Skid for Resonant Frequency Control in the PEFP DTL)

  • 김경렬;박준;김형균;김희섭;황운하;윤종철;이몽수;조은별
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2064-2069
    • /
    • 2008
  • The Resonance Control Cooling System (RCCS) prototype installed in KAERI site has been designed to control the resonant frequency of the normal conducting drift tube linac (DTL) for the Proton Engineering Frontier Project (PEFP). The RCCS water pumping skid is composed of two channels as a by-passing the cooling water and a plate heat exchanger. The required temperature can be achieved by mixing both channels in order to control its the resonant frequency at 350 MHz. The temperature controlled water pumping skid operates in combination with the Low Level Radio Frequency (LLRF) system. We have discussed the design, modeling with each components, control scheme, fabrication and test results of the water pumping skid for resonant frequency control of the DTL cavity. In conclusion, the fabricated RCCS prototype through the optimization of modeling has corresponded with the design requirement and concept.

  • PDF

수용액 분사에 의한 아이스 슬러리의 제조에 관한 실험적 연구 (An experimental study on ice slurry creation by injection of an aqueous solution)

  • 이용구;오철
    • 한국항해항만학회지
    • /
    • 제34권1호
    • /
    • pp.71-75
    • /
    • 2010
  • 아이스슬러리의 생성을 위하여 냉각평판에 작동수를 분사하는 실험을 수행하여 그에 대한 영향에 대하여 영향을 평가하였다. 실험에 사용된 에틸렌글리콜 수용액은 10~20wt%의 수용액을 사용하였다. 실험장치는 슬러리아이스 저장탱크, 브라인 탱크, 브라인 순환장치, 유량계 및 온도기록계로 구성되어 있다. 실험조건은 평균유속 1.0~2.0m/s, 냉각온도 $-17{\sim}-10^{\circ}C$의 조건 하에 실험을 수행하였다.