Effects of Relative Humidity and Temperature on the Transport of Chloride in the Concrete

  • Nam Jin-Gak;Hartt William H.;Kim Ki-Joon
    • 콘크리트학회논문집
    • /
    • 제17권5호
    • /
    • pp.821-828
    • /
    • 2005
  • To investigate the role of RH and temperature on the transport of chloride in the concrete, two groups of specimens were configured. For both groups, mix design was based on w/c=0.45, $400kg/m^3$ cement, $794kg/m^3$ fine aggregate and $858kg/m^3$ coarse aggregate. After specimen fabrication these were exposed to four different RH (35, 55, 75 and $95\%$ RH) and temperature (0, 20, 30 and $40^{\circ}C$) conditions. After 3 and 6 months $15\%$ NaCl exposure 5mm cores were taken. These cores were sliced and individual cores were ground to powder. In addition, to evaluate the effect of temperature on the chloride binding some powder samples were leached in the each of four temperature chambers. Chloride titration fur these was performed using FDOT acid titration method. Based upon the resultant data conclusions were reached regarding that 1) effective diffusion coefficient, $D_e$, increased with increasing exposure RH, suggesting that the size and number of water paths increased with elevated moisture content in the specimens, 2) $D_e$ increased with increasing temperature in the range of 0 to $40^{\circ}C$ possibly by elevated thermal activation of chloride ions and reduced chloride binding at higher temperature, 3) water soluble chloride concentration, $[Cl^-]_s$, increased with increasing temperature, and 4) chloride concentration profile for initially dry concrete specimens was higher than for the initially wet ones indicating pronounced capillary suction (sorption) occurred for the dry concrete specimens.

원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로- (The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.155-160
    • /
    • 1991
  • 전자선 측정에 사용되는 원통형 전리함의 유효 측정점 깊이에 관한 연구를 하였다. 물팬톰 속에서 Markus 평판형 전리함을 사용하여 여러 에너지(전자선 6MeV 및 9MeV, 12MeV, 20MeV) 방사선의 선량 백분율을 구하고, 이 값을 기준으로 하여 원통형 전리함으로(PW233643 내경 5.5mm 및 PR-05P 내경 4mm, PM30 내경 15mm) 구한 선량 백분율과 비하여 선량 백분율 곡선의 변위를 유효 측정점으로 계산하였다. 이 결과 전자선에서는 0.4~0.6r 만큼, $^{60}$Co 감마선에서는 0.3~0.7r 만큼 표면쪽으로 이동한 값을 측정점으로 정하여야 하는 것을 알았다.

  • PDF

Hemolysis of irradiated leukoreduced red blood cells during rapid warming: An in vitro experimental study

  • Lee, Sukyung;Lee, Sooho;Oh, Jong Eun;Shin, Won-Jung;Min, Won-Ki;Gwak, Mijeung
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제15권4호
    • /
    • pp.229-233
    • /
    • 2015
  • Background: Although water chambers are often used as surrogate blood-warming devices to facilitate rapid warming of red blood cells (RBCs), these cells may be damaged if overheated. Moreover, filtered and irradiated RBCs may be damaged during the warming process, resulting in excessive hemolysis and extracellular potassium release. Methods: Using hand-held syringes, each unit of irradiated and leukocyte-filtered RBCs was rapidly passed through a water chamber set to different temperatures (baseline before blood warming, $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$). The resulting plasma potassium and free hemoglobin levels were then measured. Results: Warming RBCs to $60^{\circ}C$ and $70^{\circ}C$ induced significant increases in free hemoglobin (median [interquartile ranges] = 60.5 mg/dl [34.9-101.4] and 570.2 mg/dl [115.6-2289.7], respectively). Potassium levels after warming to $70^{\circ}C$ ($31.4{\pm}7.6mEq/L$) were significantly higher compared with baseline ($29.7{\pm}7.1mEq/L$; P = 0.029). Potassium levels were significantly correlated with storage duration after warming to $50^{\circ}C$ and $60^{\circ}C$ (r = 0.450 and P = 0.001; r = 0.351 and P = 0.015, respectively). Conclusions: Rapid warming of irradiated leukoreduced RBCs to $50^{\circ}C$ may not further increase the extracellular release of hemoglobin or potassium. However, irradiated leukoreduced RBCs that have been in storage for long periods of time and contain higher levels of potassium should be infused with caution.

진동대 시험을 통한 Fill Dam의 내진 안정성 평가 (Evaluation of the Seismic Stability of Fill Dam by Shaking Table Tests)

  • 윤원섭;채영수;박면규
    • 한국지반신소재학회논문집
    • /
    • 제10권4호
    • /
    • pp.81-92
    • /
    • 2011
  • 본 연구에서는 흙 댐 구조물의 지진저항 특성을 파악하기 위하여 3가지 대표단면을 기초로 하여 축소모형의 비율에 해당하는 상사법칙을 고려하여 각각 1:100, 1:70, 1:50으로 토조를 제작하였다. 그리고 국내 설계기준에 준하여 장주기인 Hachinohe파, 단주기인 Ofunato파, 인공지진파를 가진하여 각 단면에 대해 가속도변화, 과잉간극수압, 수직 및 수평변위를 측정하고, 측정된 결과를 통하여 지반-구조물-유체의 상호작용에 따른 안정성을 평가하였다. 시험결과 시험 대상 단면의 변위는 지진 시 허용변위량 300mm에 비해 비교적 작은 변위로 지진 시 안정성을 확보하였다. 가속도 계측결과 Hachinohe파, Ofunato파는 할증률 20%정도로 평가되었지만 인공지진파는 할증률 30%정도로 평가되었다. 과잉간극수압비 측정결과 액상화 평가기준인 과잉간 극수압비 1이하로 모형단면은 액상화에 대해 안정성을 확보하였다.

Bottom Ash를 활용한 Chemical Compaction Pile의 주변 지반 개량 특성 평가 (Evaluation on the Characteristics of Weak Soil Adjacent to Chemical Compaction Pile of Using Bottom Ash)

  • 김상철;박경태;성익현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권1호
    • /
    • pp.163-170
    • /
    • 2007
  • 본 연구에서는 개발한 Chemical Compaction Pile(이하 CCP)공법의 연약지반 개량의 적용성을 평가하기 위하여 모형 아크릴 토조와 CCP 전용 토조를 제작하였으며, CCP를 구성하는 주재료인 Bottom Ash, 생석회 및 첨가재의 배합비를 실험변수로 하여 지반의 종류에 따른 함수비, 전단강도의 변화를 측정하였다. 실험결과, 지반의 함수비 감소나 강도증진효과는 생석회의 함유량이 많을수록 크게 나타났으며, 지반개량효과도 짧은 시일 내에 나타나는 것이 확인되었다. 또한, 지반개량에 따른 전단강도의 증진과 함수비의 변화는 지반의 종류에 따라서도 영향을 받는 것으로 나타났다. 그 외에도 개발된 CCP는 충분한 지지력도 확보하고 있어 연약지반개량과 함께 지지말뚝으로써의 기능성이 있는 것으로 평가되었다.

물흡수선량 표준에 기반한 $^{192}Ir$ 근접치료 선원 교정 시 원통형 이온함의 이온함 간 변화 (Chamber to Chamber Variations of a Cylindrical Ionization Chamber for the Calibration of an $^{192}Ir$ Brachytherapy Source Based on an Absorbed Dose to Water Standards)

  • 김성훈;허현도;최상현;김찬형;민철희;신동오;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.7-13
    • /
    • 2009
  • 본 논문은 물 흡수선량 표준에 기반하여 근접치료 선원인 $^{192}Ir$을 교정하는 것에 대한 예비적 연구를 위한 것이다. 이온함을 사용하여 물흡수선량 표준에 기반하여 근접치료 선원을 교정하기 위해선, 빔 선질 교정인자인 $k_{Q,Q_0}$가 필요하다. 본 연구에선 일차 표준을 사용하여 지정된 거리에서의 흡수선량를 측정하는 데 있어서의 현실적인 어려움 때문에 몬테칼로 전산모사와 반실험적인 방법을 통하여 $k_{Q,Q_0}$를 결정하였다. 본 연구를 위해 PTW30013 이온함 5개를 선택하였다. 포괄적 $k^{gen}_{Q,Q_0}$ 값의 경우엔 이온함간 변화가 최대 4.0%에 이른 반면, 개별적 $k^{ind}_{Q,Q_0}$ 경우엔 이온함간 변화가 최대 0.5% 이내였다. 이 결과는 물 흡수선량에 기반하여 근접치료 선원인 $^{192}Ir$을 교정시에 이온함을 왜 개별적으로 교정해야 하는지, 개별적인 교정이 얼마나 중요한 지를 보여 준다. 가까운 장래에 공기커마 세기 대신에 사용자가 근접치료 선원을 고에너지 광자빔과 전자빔의 교정에서처럼 치료에서 관심있는 물리량인 물흡수선량의 관점에서 교정할 수 있기를 희망한다.

  • PDF

마른멸치 저장중의 수분활성과 비효소적 갈변반응 (NON-ENZYMATIC BROWNING REACTIONS IN DRIED ANCHOVY WHEN STORED AT DIFFERENT WATER ACTIVITIES)

  • 한성빈;이종호;이강호
    • 한국수산과학회지
    • /
    • 제6권1_2호
    • /
    • pp.37-43
    • /
    • 1973
  • In this paper, non-enzymatic browning reactions as a factor of self stability of boiled and dried anchovy were studied to discuss the effect of water activity to the discoloring reaction and the preservative moisture content. The development of rancidity of the fish meat was also mentioned since the fish is fatty and the lipid oxidation is a functional deteriorative reaction. Fresh anchovies were boiled in $10\%$ salt solution immediately after the catch, sun dried, and stored at room temperature ($20^{\circ}C$) for two months in humidistat chambers maintaining different levels of water activity as described in Table 1. The pigments formed by non-enzymatic browning reations were extracted in two fractions, those were chloroform-methanol soluble and water dialyzed fraction, and analyzed spectrophotometrically at the wavelength of 460 nm. These two fractions were considered, respectively to be the brown pigments formed by lipid oxidation reactions for the formler and for the latter, to be the pigments developed by sugar-amino or Maillard reaction. The oxidation of lipid in anchovy meat during the storage was measured as the changes in Peroxide value and the color development of thiobarbituric acid reaction. It is summarized from the results that the rate of both reactions, lipid oxidation and browning, was affected by water activity levels. In regard to the changes in peroxide and TBA value during the storage, the propagation of lipid oxidation was obviously accelerated at lower humidities whereas the development of browning progressed at the higher. These two reactions occurring simultaneously and contrary in activity resulted in that the rate of deterioration occurring oxidatively or by browning, was the minimum at the water activity of 0.32-0.45 which were $7-9\%$ as moisture content and slightly higher value than that of monolayer (Aw=0.21, $5.11\%$ as moisture content). It is also noted that the lipid oxidative browning was presumed to dominate sugar-amino reactions so that the rate of browning of the meat was ultimately depended on the development of rancidity although sugar-amino reactions initiated earlier than the other at the first ten days of storage, particulary at higher humidity. At the lower humidity sugar-amino reactions were occurred gradually but lower levels in color development in contrast to the consistent increase in lipid oxidative browning.

  • PDF

평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구 (Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber)

  • 라정은;신동오;박소현;정호진;황의중;안성환;임영경;김동욱;윤명근;신동호;이세병;서태석;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제20권2호
    • /
    • pp.97-105
    • /
    • 2009
  • 물 흡수선량표준을 기반으로 하는 선량측정 프로토콜에서는 전자선의 선질결정 지표는 $R_{50}$이며, 선량측정의 정확성을 향상시키기 위하여 전자선의 기준 에너지가 $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV)인 고에너지 전자선에서 표준기관에 소급성이 있는 원통형이온함의 물흡수선량교정계수을 이용한 평행평판형이온함의 교차교정을 권고하고 있다. 그러나 이러한 조건을 만족하는 고에너지 전자선은 모든 치료기관에서 보유하기가 어려운 실정이다. 따라서 본 연구에서는 평행평판형이온함의 교차교정 시 16 MeV 이상의 고 에너지 전자선뿐 아니라 12 MeV 이하의 전자선 에너지에서 얻은 평행평판형이온함의 교정계수를 이용하여 선량차이를 각각 비교하였다. 전자선 선량측정은 PTW 30013, Wellhofer FC65G의 Farmer형 원통형이온함과 PTW 34001, Wellhofer PPC40의 Roos형 평행평판형이온함을 이용하였으며 물팬텀내 기준깊이 $Z_{ret}=0.6R_{50}-0.1$(cm)에 원통형이온함과 평행평판형이온함을 같은 위치에 놓고 교차교정을 실시하였다. 교차교정 선질 20 MeV에서 결정된 교정계수를 적용한 물 흡수선량과 전자선에너지 12, 16 MeV에서의 물 흡수선량 차이는 0.2% 이내로 비교적 잘 일치하는 연구결과를 보였다. 그러므로 교차교정 선질 차이에 의한 흡수선량 값 상호 비교한 결과는 측정 불확도내에서 잘 일치하고 있어 각 기관에서 보유하고 있는 의료용가속기의 최고 전자선 선질에서의 교차교정도 유효하다고 사료된다.

  • PDF

온도상승 환경 처리가 논토양과 용수에서 탄소량 변화와 벼 생육에 미치는 영향 (Elevated Temperature Treatment Induced Rice Growth and Changes of Carbon Content in Paddy Water and Soil)

  • 홍성창;허승오;최순군;최동호;장은숙
    • 한국환경농학회지
    • /
    • 제37권1호
    • /
    • pp.15-20
    • /
    • 2018
  • 상승온도 처리에 따른 논토양 탄소의 변동과 벼 생육을 조사한 결과를 요약하면 다음과 같다. 소형 상부개방형 챔버를 이용하여 대기온도 보다 $0.4^{\circ}C$, $0.5^{\circ}C$, $0.9^{\circ}C$ 상승온도 환경을 조성하여 상승온도를 처리할 수 있었다. 사각챔버의 내부온도는 대기보다 평균온도와 최고온도가 높고 최저온도는 낮은 특징을 나타내었다. 상승온도 처리구의 포트 내 표면수의 TOC 농도는 대조구 보다 상승온도 처리구에서 높았고 시간이 경과함에 따라 점차 낮아졌다. 벼 재배후 토양의 TOC 함량은 대조구 보다 상승온도 처리구에서 낮았다. 상승온도 처리로 벼 식물체의 탄소함량은 감소하고 질소함량은 증가하여 C/N 율은 감소하는 경향을 나타내었다. 상승온도 처리로 대조구 보다 벼의 줄기 길이와 줄기무게가 유의하게 증가하였으나 이삭수와 벼 낱알 무게는 유의한 차이를 나타내지 않았다.

고 에너지 광자선의 표준측정법에 대한 선량 교정 프로그램 개발 (Development of a Dose Calibration Program for Various Dosimetry Protocols in High Energy Photon Beams)

  • 신동오;박성용;지영훈;이창건;서태석;권수일;안희경;강진오;홍성언
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.381-390
    • /
    • 2002
  • 목적 : 고 에너지 광자선에 대한 기준점에서의 물 흡수선량 계산을 절차상 또는 계산상의 오류를 피하기 위해 공기커마(혹은 조사선량) 교정정수에 토대를 두고 있는 IAEA TRS-277과 AAPM TG-21 및 최근 발표된 새로운 개념의 물 흡수선량 교정정수에 토대를 두고 있는 IAEA TRS-398과 AAPM TG-51 표준측정법에 기초한 고 에너지 광자선의 선량 교정 프로그램을 개발하고자 한다. 대상 및 방법 : 현재 국내외에서 널리 사용되고 있는 고 에너지 광자선에 대한 흡수선량 표준측정법은 IAEA TRS-277과 AAPM TG-21로서 공기커마(혹은 조사선량) 교정정수에 토대를 두고 있어 수식 체계가 복잡하고, 사용된 물리량에 대한 불확정도가 커서 선량측정의 정확성을 향상시키는데 한계가 있다. 최근 국제원자력기구와 미국의학물리학회에서는 새로운 개념의 물 흡수선량 교정정수에 토대를 두고 있는 IAEA TRS-398과 AAPM TG-51을 발표하였다. 개발된 네 종류의 선량 교정 프로그램은 이들 표준측정법에서 사용되고 있는 수식체계와 물리적인 매개변수를 엄격하게 적용하였고, 선량계에 대한 정보 및 물리적인 값에 대한 표와 그래프 값은 수치화하여 데이터베이스화하였다. 이들 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 $C^{++}$ 언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 결과 : 네 종류의 표준측정법에 대하여 개발된 고 에너지 광자선에 대한 선량 교정 프로그램은 사용자가 병원에서 사용하고 있는 표준측정법을 선택하여 선량측정 절차에 따라 선량계, 선질 특성 및 측정 조건에 관한 정보와 측정 결과를 입력하고, 순차적으로 수행하도록 되어 있어 절차상 혹은 선량 계산에 있어서 사용자간의 오차 및 실수를 최소화할 수 있었다 또한 서로 다른 개념의 네 종류의 표준측정법에 대한 기준점에서의 선량값을 상호 비교할 수 있었다. 결론 : 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스함으로써 수작업으로 각 프로토콜의 수행 절차상 혹은 사용자간의 발생할 수 있는 개인적인 실수 및 오차를 줄일 수 있었다. 또한 이 프로그램은 사용자 편의성을 고려하였고, 모든 보정계수와 물흡수선량을 정확하게 계산할 수 있기 때문에 각 표준측정법에 대한 주요한 차이점을 비교 분석할 수 있어 사용자가 적당한 표준측정법을 선택하여 수행하므로써 고 에너지 광자선 선량 교정에 이용시 매우 유익할 것으로 사료된다.