• 제목/요약/키워드: water and wastewater management

검색결과 458건 처리시간 0.026초

혐기-호기 상향류 필터 공정에서 양식배출수의 질산화 및 탈질 연구 (Nitrification and Denitrification of Land-based Fish Farm Wastewater using an Anaerobic-Aerobic Upflow Biological Aerated Filter)

  • 박노백;이현영;김성민;이준상
    • 한국수산과학회지
    • /
    • 제47권5호
    • /
    • pp.622-629
    • /
    • 2014
  • This study induced biological denitrification and nitrification via a biofiltration process with the view of removing nitrogen from land-based fish farm effluent. To achieve this, we operated an aquaculture nitrogen-removal system that includes a denitrification and nitrification reactor [working volume 40 L, flow rate 64.8 L, HRT (hydraulic retention time) 14.8 h, HRT considering recycling of NOx 7.4 h]. In the continuous process, the nitrification rate of ammonium nitrogen exceeded 90% at a steady state and the denitrification efficiency exceeded 80% with recycling to a pre-anoxic reactor. In addition, the pH in the final effluent was lower with a low influent water alkalinity averaging 100 mg/L (as $CaCO_3$). For effective denitrification reactions, carbon must be supplied via particulate organic matter (POM) hydrolysis because of the low C/N (carbon/nitrogen) ratio in the water.

미세 플라스틱의 종합적 고찰: 근원, 경로 및 시사점 (A comprehensive review of microplastics: Sources, pathways, and implications)

  • ;;;전민수;김영철;김이형
    • 한국습지학회지
    • /
    • 제22권2호
    • /
    • pp.153-160
    • /
    • 2020
  • 미세플라스틱 관련 대부분의 연구에서는 미세플라스틱(MP)을 5mm 미만의 플라스틱 입자로 정의하고 있다. 미세플라스틱은 자연계에 광범위하게 분포함으로써 인간과 환경에 잠재적 위험성이 높아지고 있는 물질이다. 특히 미세플라스틱은 인간을 포함하여 살아있는 생명체에게 물리적 영향을 줄 뿐만 아니라 신진대사와 호르몬 등과 같은 생태적 기능에 심각한 영향을 줄 수 있다. 따라서 본 연구는 환경에서 미세플라스틱의 근원, 경로 및 영향에 대한 이해를 돕기 위해 수행되었다. 미세플라스틱은 본질적으로 1 차 및 2 차 미세플라스틱으로 분류되며, 물리적 및 화학적 특성에 따라 분류되기도 한다. 미세플라스틱의 주요 경로는 강우유출수와 폐수를 통한 배출이며, 하천과 하구역을 거쳐 해양과 같은 대규모 수역으로 이동한다. 미세플라스틱은 폐수 처리 과정에서 크게 제거되기 때문에 폐수처리장 유출수의 미세플라스틱 농도는 강우유출수 내 농도보다 상대적으로 낮게 나타난다. 그러나 폴리머의 분포 측면에서는 폐수가 강우유출수보다 다양한 폴리머 종류를 포함하고 있는 것으로 나타났다. 폐수와 강우유출수에서 발견되는 일반적인 폴리머 유형은 폴리프로필렌(PP), 폴리염화비닐(PVC), 폴리스티렌(PS), 폴리에틸렌(PE) 및 폴리에틸렌테레프탈레이트(PET) 등으로 나타났다. 환경에서 지속적으로 배출이 증가하고 있는 미세플라스틱의 수는 인간과 다른 생명체에게 미래 위험을 줄 수 있다. 그 동안 미세플라스틱에 대한 연구 결과물의 수가 증가함에도 불구하고 환경에 미치는 영향을 완화하기 위한 구체적 규제 및 관리 전략을 수립하기에는 많은 추가 연구가 필요한 것으로 나타났다.

오존접촉조 설계를 위한 소독 기준 (Ozone disinfection criteria for contactor design)

  • DumeauC;BoisdonV
    • 수도
    • /
    • 제24권6호통권87호
    • /
    • pp.23-31
    • /
    • 1997
  • Ozonation is an effective process in providing microbiologically safe drinking water. The operation of the ozonation stage is often based on disinfection criteria which include security factors, such as the CT criterion. This type of ozonation management, which mat include large safety margins, will no longer be possible, since formation of ozonation byproducts has to be avoided. In order to reduce the security factor, a computerized tool to predict with more accuracy inactivation of micro-organisms in the ozonation process has been developed.

  • PDF

강원도 태백지역 2008년 가뭄의 원인분석 연구 (A Root Cause Analysis for Drought in Taeback City, Kangwon-do in 2008)

  • 김주환;최계운;박상우
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.351-359
    • /
    • 2010
  • 최근 들어, 기상이변 및 국지성 집중호우로 인한 침수피해가 계속적으로 발생하고 있다. 따라서 재해 피해 저감을 위한 대책을 수립할 시에 풍수해 관리 분야에 있어 대부분이 홍수피해에 집중되고 있는 실정이다. 그러나 가뭄 재해 또한 홍수피해에 못지 않은 규모의 피해를 발생시키고 있으며, 가뭄 피해는 그 발생빈도가 아직 크지 않으나 점차 증가하고 있다는 부분에 주목할 필요가 있다. 강원도 태백시는 2008년 가을부터 2009년 봄까지 심한 가뭄 피해를 입어 심각한 물부족에 시달린 중요한 예시이다. 따라서 본 연구에서는 이 지역에 대한 물 부족 요인을 파악하기 위하여 수문기상학적 분석을 통한 가뭄빈도를 분석하였으며, 광역상수도 공급원인 광동댐의 운영과 수요-공급 분석을 통하여 물 부족 원인에 대하여 분석하였다. 그 결과, 갈수우량의 빈도 분석을 통한 태백지역 가뭄은 20년 빈도에 해당하는 것으로 나타났으며, 이를 바탕으로 광동댐 저수지에는 저수율이 약 52% 만 확보 가능한 것으로 나타났다. 또한, 갈수기의 강우량은 평년에 비하여 작게 발생하였다. 그러나 피해 발생 시 태백시의 상수도 수요는 평년에 비하여 많았던 것으로 판단되었다. 본 연구를 통하여, 가뭄시 물 부족 원인을 분석하였으며, 이는 가뭄시 물 부족 대책 마련을 위한 기초자료로 활용될 수 있을 것으로 예상된다.

주성분분석(PCA) 방법을 이용한 금강 수질의 주요 오염원 영향 평가 (Evaluation of significant pollutant sources affecting water quality of the Geum River using principal component analysis)

  • 레게세 나트나엘 시페로;김재영;서동일
    • 한국수자원학회논문집
    • /
    • 제55권8호
    • /
    • pp.577-588
    • /
    • 2022
  • 본 연구는 금강의 조류 성장에 대한 제한영양소와 수질에 영향을 미치는 주요 지류를 파악하고 수질개선을 위한 관리대안을 제시하는 것을 목적으로 수행되었다. 금강 대청댐 하류에 위치한 5개 수질측정소에서 약 8년간(2013~202) 환경부의 물환경정보시스템(water.nier.go.kr)과 수자원관리정보시스템(wamis.go.kr)에서 14개의 수질항목의 자료를 분석하였다. 금강의 4대강 수중보 수문 개방 시 TP(총인)와 수온은 하천 하류의 조류 성장에 큰 영향을 미친다. 본 연구에는 수질변수간의 상관관계를 규명하고 금강의 조류 성장에 영향을 미치는 중요인자를 파악하고자 하였다. 최하류에 위치한 백제보수질측정소(WQ5)에서 TP와 수온은 Chl-a와 특별히 높은 상관관계를 보여 조류 번식에 상당한 영향을 미친다는 것을 나타냈다. 또한 본 연구에서는 금강의 양대 지류인 갑천과 미호천의 주요 오염원을 식별하고 우선순위를 지정하기 위해 주성분분석(Principal Component Analysis, PCA) 방법을 이 적용하였다. PCA방법을 이용하여 갑천과 미호천의 수질에 영얗ㅇ을 미치는 3대 오염원을 각각 파악하였다. 갑천의 경우 폐수처리장과 도시·농업 오염이 주요 오염원으로, 미호천의 경우 농지, 도시, 산림이 주요 오염원으로 각각 확인되었다. PCA는 금강 및 그 지류의 수질오염원을 구체적으로 파악하는 데 효과적인 것으로 판단되어 수질관리 전략의 효율을 제고하는 데에, 활용될 수 있을 것으로 보인다.

중권역 대표지점의 목표수질 달성도 평가 - TOC를 중심으로 - (Evaluation of Attainment Ratio on Water Quality Goal of the Mid-watershed Representative Station)

  • 이재호;이승현;이수형;이재관
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.525-530
    • /
    • 2017
  • The attainment ratios of the water quality goals of the 114 mid-watershed representative stations, examined during the period2011 to 2015, were evaluated in the study. Of the four major river basins, the attainment ratio on water quality goal of the Geum River basin turned out to be the lowest. As a result of formal evaluation of the attainment ratios of BOD, COD and TOC, it was found that the attainment ratio of COD was much lower than that of BOD and TOC (I a circumstance thought to be caused by the higher COD/BOD and COD/TOC ratios of the water quality of the river than those of the environmental water quality standard). As well, higher COD/BOD and COD/TOC of wastewater discharged from point and non-point sources (other than those of the environmental water quality standards) might possibly represent one of the reasons. We also compared attainment ratio between the main stream and tributaries, which indicated that the higher attainment ratio was present in the main stream. The attainment ratio is also documented as more significant in the winter season than the summer season, possibly due to the contribution of non-point pollutants swept in by rain during the summer season during documented periods of high precipitation. Thus, water quality management in summer season and improvement of water quality of the tributaries might be important as a means of increasing attainment ratio on water quality goal.

A case of syncope in a villager with hypertrophic cardiomyopathy after hydrogen sulfide exposure by an unauthorized discharge of wastewater

  • Hyeonjun Kim;Seunghyeon Cho;Inho Jung;Sunjin Jung;Won-Ju Park
    • Annals of Occupational and Environmental Medicine
    • /
    • 제35권
    • /
    • pp.34.1-34.8
    • /
    • 2023
  • Background: Hydrogen sulfide is a toxic substance that humans can be exposed to occupationally, and cases of hydrogen sulfide poisoning of workers in industrial sites are commonly reported. However, there have been no cases of poisoning of the public due to an unauthorized discharge of wastewater, so it is important to describe this incident. Case presentation: In a small village in Jeollanam-do, Republic of Korea, accounts of a terrible stench had been reported. A 26-year-old man who lived and worked in a foul-smelling area was taken to the emergency room with a headache, dizziness, nausea, and repeated syncope. A subsequent police and Ministry of Environment investigation determined that the cause of the stench was the unauthorized discharge of 9 tons of wastewater containing hydrogen sulfide through a stormwater pipe while the villagers were sleeping. The patient had no previous medical history or experience of symptoms. Leukocytes and cardiac markers were elevated, an electrocardiogram indicated biatrial enlargement, left ventricular hypertrophy, and corrected QT interval prolongation. Myocardial hypertrophy was detected on a chest computed tomography scan, and hypertrophic cardiomyopathy was confirmed on echocardiography. After hospitalization, cardiac marker concentrations declined, symptoms improved, and the patient was discharged after 7 days of hospitalization. There was no recurrence of symptoms after discharge. Conclusions: We suspect that previously unrecognized heart disease manifested or was aggravated in this patient due to exposure to hydrogen sulfide. Attention should be paid to the possibility of unauthorized discharge of hydrogen sulfide, etc., in occasional local incidents and damage to public health. In the event of such an accident, it is necessary to have government guidelines in place to investigate health impact and follow-up clinical management of exposed residents.

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

APID공정 내 공정진단을 위한 dynamic $\bar{x}$-R 관리도의 적용 (Application of Dynamic $\bar{x}$-R Control Chart for Advanced Phase Isolation Ditch (APID) Process)

  • 안상우;곽성근;정영욱;정무근;박재우
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.704-712
    • /
    • 2009
  • Advanced Phase Isolation Ditch (APID) process was studied to develop economic retrofitting technology, for the plants where retrofitting of common activated sludge process is required. In this study, to evaluate and monitor the effluent water quality ($BOD_5$, SS, T-N, and T-P) and operating conditions (Influent, SVI, SRT, and HRT) as process capable and stable parameters for treating municipal wastewater, a demonstration plant was installed and operated in the existing sewage treatment plant of P city. During this study, the average effluent $BOD_5$, SS, T-N, and T-P concentrations were 7.7, 5.6, 10.8, and 1.6 mg/L. Trend analysis of influent $BOD_5$, SS, T-N, and T-P in APID process were illustrated that APID process need for more strong APID process management on the winter session, such as developing new intermediated aeration mode, operating methods, and managements strategy. At the application of control chart, the signal of uncommon effects at APID process was determined much higher existing control chart tntr conventional control chart in this study. These results indicate that conventional control chart has been collected and determined cleary signal at only stable situation. Therefore, newly developed APID process of dynamic control chart can be one of the useful tool for monitoring and management process.

점 오염원 조사를 통한 목포 내항의 수질관리 (Management of Water Quality by the Point Source in Mokpo Inner Bay)

  • 김도희
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.273-283
    • /
    • 2006
  • 2004년 강수량이 많았던 8월 목포 주변해역의 8개 지점에서 COD를 조사한 결과, 북항 앞바다에서 6.80 ppm, 영산강 하구둑 부근 해역에서 4.42 ppm, 신안비치 호텔 앞 해역에서 4.60 ppm으로 나타나 해양환경 기준치의 3등급을 초과하고 있었고 나머지 지점에서는 2-3등급 수준을 보였다. 총질소 농도는 1.23-3.56 ppm으로 전 지점에서 3등급 이상이었고, 총인의 농도는 0.07-0.12 ppm으로 2-3등급의 수질을 보였다. 이와 같은 수질은 수산생물의 서식, 양식 및 해수욕 등의 해양레저 활동을 하기에 부적합하며 공업용수와 선박의 정박 등에 이용 할 수 있는 수질 상태를 보였다. 육상으로부터의 목포 내항으로 유입되는 12개 지점의 점원 유입 부하량과 그 기여율을 조사한 결과, 전체 유입양 중 영산강으로부터 유입되는 총질소의 양이 70-93 %, 총인의 유입량도 31-91%를 차지하고 있어 목포 내항의 수질개선을 위해서는 영산강의 수질개선이 급선무이며, 다음으로 북항 하수처리장, 임암천, 남해 하수처리장 순으로 방류수 중의 질소와 인을 우선적으로 제어해야 될 것으로 판단되었다.

  • PDF