• 제목/요약/키워드: water and wastewater management

검색결과 458건 처리시간 0.022초

Microbial population dynamics in constructed wetlands: Review of recent advancements for wastewater treatment

  • Rajan, Rajitha J.;Sudarsan, J.S.;Nithiyanantham, S.
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.181-190
    • /
    • 2019
  • Constructed wetlands are improvised man-made systems, designed for adopting the principle of natural wetlands for purifying wastewater - the elixir of life. They are used widely as a cost-effective and energy-efficient solution for treating greywater generated from different tertiary treatment sources. It provides an elaborate platform for research activities in an attempt to recycle earth's natural resources. Among the several organic impurities removal mechanisms existing in constructed wetland systems, the earth's active microbial population plays a vital role. This review deals with the recent advancements in constructed wetland systems from a microbiological perspective to (effect/ devise/ formulate) chemical and physical treatment for water impurities. It focuses on microbial diversity studies in constructed wetlands, influence of wetland media on microbial diversity and wetland performance, role of specific microbes in water reuse, removal of trace elements, some heavy metals and antibiotics in constructed wetlands. The impurities removal processes in constructed wetlands is achieved by combined interactive systems such as selected plant species, nature of substrate used for microbial diversity and several biogeochemical effected reaction cycles in wetland systems. Therefore, the correlation studies that have been conducted by earlier researchers in microbial diversity in wetlands are addressed herewith.

XP-SWMM을 이용한 도시화 유역에서의 유출 관리 방안 연구 (Management Scheme of Urbanization Runoff Using XP-SWMM)

  • 이범희;채준영
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.1167-1172
    • /
    • 2004
  • 최근 급격한 인구증가와 산업화, 도시화로 포장지역의 증가에 따른 불투수지역의 증가로 유역의 유출 특성의 변화를 유발시키고 있다. 도시화 유역의 효율적인 관리를 위해서는 유역에 내할 정확할 지형인자 및 수문 관련 인자들을 추출해야 한다. 본 연구에서는 GIS와 XP-SWMM을 이용하여 안양천유역의 유출분석을 수행하였다. 안양천 유역을 GIS를 이용하여 13개의 소유역으로 분할하고 입력자료를 구축하였다. GIS를 이용하여 지형도로부터 각각의 소유역에 대하여 면적, 경사도, 폭과 하천 각 구간의 길이, 경사도를 얻었고, 토지이용도와 토양도로부터 불투수비, 토지이용상태, 침투능에 내한 정보를 얻었다. 여기서 얻은 결과를 토대로, 안양천 유역에 도시유출 모형인 XP-SWMM을 적용하여 도시화유역의 관리방안을 제시하였다.

  • PDF

SED2D모형을 이용한 저수지 퇴사거동 모의-모의시간간격의 민감도를 중심으로 (Simulation of Sediment Deposition Behavior in a Reservoir using a SED2D model: Focusing on Sensitivity of Simulation Time Step)

  • 김대근
    • 상하수도학회지
    • /
    • 제26권1호
    • /
    • pp.87-95
    • /
    • 2012
  • In this study, the following conclusions were obtained from an investigation of the effect of the simulation time step on the simulation results of the two-dimensional, vertically averaged sediment transport model SED2D and an analysis of the deposited sediment distribution in suspended sediments of reservoirs according to grain size. The simulation time step has a significant effect on the deposited sediment distribution in a reservoir. In particular, if the simulation time step is set to be excessively large, physically invalid results are obtained. Additionally, in order to determine an appropriate simulation time step for SED2D, the selection of a simulation time step that will allow the analysis of the suspended sediment concentration profile at the main points of the simulation domain is necessary. The deposited sediment distribution in a reservoir according to grain size, including suspended sediments of clay, silt, and sand, was successfully simulated. Such information will prove valuable in application to the establishment of efficient management and reduction measures of reservoir sediment deposits.

분산형 저류시설의 실시간 네트워크 제어기술 적용시 고려 사항 (Methods for an application of real-time network control on distributed storage facilities)

  • 백현욱;류재나;오재일;김태형
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.711-721
    • /
    • 2013
  • Optimal operation of a combined sewer network with distributed storage facilities aims to use the whole retention capacity of all reservoirs efficiently before overflows take place somewhere in the considered network system. An efficient real-time network control (RTNC) strategy has been emerging as an attractive approach for reducing substantially the overflows from a sewer network compared to the conventional fixed or manually adjusted gate setting method, but the related concrete framework for RTC development has not been throughly introduced so far. The main goal of this study is to give a detailed description of the RTNC systems via reviewing several guidelines published abroad, and finally to suggest methods for the proper application of RTNC on distributed storage facilities. Especially, this study is focused on emphasizing the importance of hierarchical structure of RTNC system that consists of three control layers (management, global control and local control). Further, with regard to the global control layer which is responsible for the central overall network control, the wide-ranging details of two components (adaption and optimization layers) are also presented. This study can provide the valuable basis for the RTNC implementation in the particular sewer network with distributed multiple storage facilities.

Photodegradation stability study of PVDF- and PEI-based membranes for oily wastewater treatment process

  • Ong, C.S.;Lau, W.J.;Al-anzi, B.;Ismail, A.F.
    • Membrane and Water Treatment
    • /
    • 제8권3호
    • /
    • pp.211-223
    • /
    • 2017
  • In this work, an attempt was made to compare the effects of UV irradiation on the intrinsic and separation properties of membranes made of two different polymeric materials, i.e., polyvinylidene fluoride (PVDF) and polyetherimide (PEI). The changes on membrane structural morphologies and chemical characteristics upon UV-A exposure (up to 60 h) were studied by FESEM and FTIR, respectively. It was found that cracks and fractures were detected on the PVDF-based membrane surface when the membrane was exposed directly to UV light for up to 60 h. Furthermore, the mechanical strength and thermal stability of irradiated PVDF-based membrane was reported to decrease with increasing UV exposure time. The PEI membrane surface meanwhile remained almost intact throughout the entire UV irradiation process. Filtration experiments showed that the permeate flux of UV-irradiated PVDF membrane was significantly increased from approximately 11 to $16L/m^2.h$ with increasing UV exposure time from zero to 60 h. Oil rejection meanwhile was decreased from 98 to 85%. For the PEI-based membrane, oil rejection of >97% was recorded and its overall structural integrity was marginally affected throughout the entire UV irradiation process. The findings of this work showed that the PEI-based membrane should be considered as the host for photocatalyts incorporation if the membrane was to be used for UV-assisted wastewater treatment process.

한강수계 농업용저수지 관리방안 (Management Measures for the Control of Agricultural Reservoirs in Han River Watershed)

  • 김호섭;공동수;정동일;황순진
    • 한국물환경학회지
    • /
    • 제25권3호
    • /
    • pp.386-393
    • /
    • 2009
  • This study was carried out to assess water quality and to introduce the management measures for water quality improvement with the collected data from 87 agricultural reservoirs in Han river watershed. According to the water quality criteria (WQC) for lake based on the COD, TP, TN and chl.a concentration, 18, 16, 4 and 19 of 87 reservoirs exceed class IV, respectively. Based on the trophic state index (TSI) with chl.a concentration, 51 of selected reservoirs appeared to be eutrophic. Phosphorus was limiting nutrient on algal growth in 58 reservoirs. TP, chl.a and COD concentration in 23 of 49 agricultural reservoirs with chl.a concentration ${\geq}25{\mu}g/L$ and eutrophic exceed class IV by WQC. Also, the mean depth in 21 of 23 reservoirs was below 5m. Our results suggest that advanced wastewater treatment and crop land control in watershed of reservoirs with TP concentration ${\geq}0.1mg/L$ would be a effective tool to improve water quality. Dredging would to be effective measure in reservoirs with mean depth < 5 m and relatively old age. In reservoirs with chl.a concentration ${\geq}50{\mu}g/L$, application of technique such dissolved air flotation (DAF) and P inactivation be effective to improve water quality by removing particulate matters in water column. The management measure to control inflow such as sedimentation basin, Pre-dam and diversion would to be application in reservoirs with shallow depth, while large watershed and surface area.

생애주기 에너지 분석을 이용한 상수관망의 생애주기 결정 (Life cycle determination of water distribution system using life cycle energy analysis)

  • 이승엽;유도근;김중훈
    • 상하수도학회지
    • /
    • 제29권1호
    • /
    • pp.11-21
    • /
    • 2015
  • When designing Water Distribution System (WDS), determination of life cycle for WDS needs to be preceded. And designer should conduct comprehensive design including maintenance and management strategies based on the determined life cycle. However, there are only a few studies carried out until now, and criteria to determine life cycle of WDS are insufficient. Therefore, methodology to determine life cycle of WDS is introduced in this study by using Life Cycle Energy Analysis (LCEA). LCEA adapts energy as an environmental impact criterion and calculates all required energy through the whole life cycle. The model is build up based on the LCEA methodology and model itself can simulate the aging and breakage of pipes through the target life cycle. In addition the hydraulic analysis program EPANET2.0 is linked to developed model to analyze hydraulic factors. Developed model is applied to two WDSs which are A WDS and B WDS. Model runs for 1yr to maximum 100yr target life cycle for both WDSs to check the energy tendency as well as to determine optimal life cycle. Results show that 40yr and 54yr as optimal life cycle for each WDS, and tendency shows the effective energy is keep changing according to the target life cycle. Introduced methodology is expected to use as an alternative option for determining life cycle of WDS.

불확실성을 고려한 통합유역모델링 (Integrated Watershed Modeling Under Uncertainty)

  • 함종화;윤춘경;다니엘 라욱스
    • 한국농공학회논문집
    • /
    • 제49권4호
    • /
    • pp.13-22
    • /
    • 2007
  • The uncertainty in water quality model predictions is inevitably high due to natural stochasticity, model uncertainty, and parameter uncertainty. An integrated modeling system under uncertainty was described and demonstrated for use in watershed management and receiving-water quality prediction. A watershed model (HSPF), a receiving water quality model (WASP), and a wetland model (NPS-WET) were incorporated into an integrated modeling system (modified-BASINS) and applied to the Hwaseong Reservoir watershed. Reservoir water quality was predicted using the calibrated integrated modeling system, and the deterministic integrated modeling output was useful for estimating mean water quality given future watershed conditions and assessing the spatial distribution of pollutant loads. A Monte Carlo simulation was used to investigate the effect of various uncertainties on output prediction. Without pollution control measures in the watershed, the concentrations of total nitrogen (T-N) and total phosphorous (T-P) in the Hwaseong Reservoir, considering uncertainty, would be less than about 4.8 and 0.26 mg 4.8 and 0.26 mg $L^{-1}$, respectively, with 95% confidence. The effects of two watershed management practices, a wastewater treatment plant (WWTP) and a constructed wetland (WETLAND), were evaluated. The combined scenario (WWTP + WETLAND) was the most effective at improving reservoir water quality, bringing concentrations of T-N and T-P in the Hwaseong Reservoir to less than 3.54 and 0.15 mg ${L^{-1}$, 26.7 and 42.9% improvements, respectively, with 95% confidence. Overall, the Monte Carlo simulation in the integrated modeling system was practical for estimating uncertainty and reliable in water quality prediction. The approach described here may allow decisions to be made based on probability and level of risk, and its application is recommended.

수계 유출가능성이 있는 유해화학물질 분류화 (Categorization of Hazard Chemicals Potentially Discharged into Water System)

  • 안윤주;남선화;이재관
    • 한국물환경학회지
    • /
    • 제24권2호
    • /
    • pp.247-259
    • /
    • 2008
  • The utilization of a variety of hazard chemicals bears risks to human health and ecosystem. The increasing usage of various chemicals indicates the greater emission of those chemicals to water system, and the subsequent deterioration of water quality. Water system is vulnerable to many pollutants, however, there are limitations of managing a range of hazard chemicals based on insufficient legal foundations. Therefore it is needed to select hazard chemicals that can be potentially discharged into water system, and subsequently to classify a wide range of existing chemicals for better management of those chemicals. In this study, the 259 candidate chemicals of concern were selected from the lists of the toxic released inventory chemicals (148), hazard concern candidate chemicals (106), and wastewater effluent standard candidate chemicals (116). We suggested the category 1, 2, 3 and 4 of hazard chemicals potentially discharged into water system. The assessment factors considered for the classification were hazard potential, persistence and emission to water body. This work was conducted as a part of the project entitled 'Development of integrated methodology for evaluation of water environment', and the results were used to develop the monitoring lists of hazard chemicals in four major rivers in Korea.

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.