• Title/Summary/Keyword: water and wastewater management

Search Result 459, Processing Time 0.031 seconds

Development of a Concentration Prediction Model for Disinfection By-product according to Introduce the Advanced Water Treatment Process in Water Supply Network (고도정수처리에 따른 상수도 공급과정에서의 소독부산물 농도 예측모델 개발)

  • Seo, Jeewon;Kim, Kibum;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.421-430
    • /
    • 2017
  • In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.

Development of the ultra/nano filtration system for textile industry wastewater treatment

  • Rashidi, Hamidreza;Sulaiman, Nik Meriam Nik;Hashim, Nur Awanis;Bradford, Lori;Asgharnejad, Hashem;Larijani, Maryam Madani
    • Membrane and Water Treatment
    • /
    • v.11 no.5
    • /
    • pp.333-344
    • /
    • 2020
  • Advances in industrial development and waste management over several decades have reduced many of the impacts that previously affected ecosystems, however, there are still processes which discharge hazardous materials into environments. Among industries that produce industrial wastewaters, textile manufacturing processes play a noticeable role. This study was conducted to test a novel continuous combined commercial membrane treatment using polyvinylidene fluoride (PVDF), ultrafiltration (UF), and polyamide (PA) nanofiltration (NF) membranes for textile wastewater treatment. The synthetic textile wastewater used in this study contained sodium silicate, wax, and five various reactive dyes. The results indicate that the removal efficiency for physical particles (wax and resin) was 95% through the UF membrane under optimum conditions. Applying UF and NF hybrid treatment resulted in total effective removal of dye from all synthetic samples. The efficiency of sodium silicate removal was measured to be between 2.5 to 4.5% and 13 to 16% for UF and NF, respectively. The chemical oxygen demand in all samples was reduced by more than 85% after treatment by NF.

Adsorption kinetics and isotherms of phosphate and its removal from wastewater using mesoporous titanium oxide

  • Lee, Kwanyong;Jutidamrongphan, Warangkana;Lee, Seokwon;Park, Ki Young
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.161-169
    • /
    • 2017
  • The adsorption of phosphate onto mesoporous $TiO_2$ was investigated in order to reduce phosphorus concentrations in wastewater and provide a potential mode of phosphorus recovery. Three equilibrium isotherms were used to optimize and properly describe phosphate adsorption ($R^2$>0.95). The maximum capacity of phosphate on the adsorbent was found to be 50.4 mg/g, which indicated that mesoporous $TiO_2$ could be an alternative to mesoporous $ZrO_2$ as an adsorbent. A pseudo-second order model was appropriately fitted with experimental data ($R^2$>0.93). Furthermore, the suitable pH for phosphate removal by $TiO_2$ was observed to be in the range of pH 3-7 in accordance with ion dissociation. In contrast, increasing the pH to produce more basic conditions noticeably disturbed the adsorption process. Moreover, the kinetics of the conducted temperature study revealed that phosphate adsorption onto the $TiO_2$ adsorbent is an exothermic process that could have spontaneously occurred and resulted in a higher randomness of the system. In this study, the maximum adsorption using real wastewater was observed at $30^{\circ}C$.

A Study on the Development of Optimal Renewal Planning Model in Water Supply Facilities Connected to Future Financial Plan of Water Providers (수도사업자의 장래 재정계획과 연계한 상수도시설의 최적 개량계획 수립 모델 개발 연구)

  • Lim, Sanghyun;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.149-159
    • /
    • 2017
  • It is considered necessary to renewal a considerable number of water supply facilities in Korea because they began to be intensively buried in the period of rapid economic growth. Accordingly, local water providers are required to take measures against this situation, but they have currently been caught in a vicious circle of the lack of budget spent in renewing water supply facilities because county-based small-scale local water supply cannot afford to cover annual expenditures with their revenues from water rates. Therefore, this study developed an optimal renewal planning model capable of achieving a balance of financial revenue and expenditure in local water supply using nonlinear programming and furthermore of minimizing the total cost incurred during the analysis. To this end, this study selected the water supply area located in County Y as a research area to build the financial revenue and expenditure and used Solver function provided by Microsoft Excel to use nonlinear programming. As a result, this study developed an optimal renewal planning model minimizing incurred costs in consideration of 6 items in the financial revenue and expenditure. The optimal renewal plan was modeled according to the available annual budget. As a result, this study proposed SICD, a scenario to minimize total costs from the perspective of water suppliers, and SITS, a scenario to minimize the increase in water rates from the perspective of consumers. It can be said that the method proposed in this study is the core of the optimal financial and renewal plans as a final stage of asset management for water supply facilities. Therefore, it is considered possible for local water providers to use the method proposed in this study according to circumstances for the asset management of water supply facilities.

Management of Nonpoint Sources in Watershed - with reference to Daechong Reservoir in Korea (수계의 비점오염원 관리 - 대청호를 중심으로)

  • Lee, Jong-Ho
    • Journal of Environmental Impact Assessment
    • /
    • v.9 no.3
    • /
    • pp.163-176
    • /
    • 2000
  • The purpose of this study is to analyze the pollutant loads and its distribution, and to suggest the management of nonpoint sources in Daechong Reservoir. The loads from point and nonpoint sources such as population, industry, livestock and land use were calculated per stream or river with topography(1:25,000) of the watershed of Daechong Reservoir. The generating pollutant loads were obtained through multiplication of pollutant sources by generating pollutant quantity per unit pollutant source. The effluent point sources loads is defined as loads from wastewater treatment facilities such as domestic, industrial and livestock wastewater treatment facilities, which were calculated through multiplication of effluent flowrates by water quality constituents concentration. Untreated point sources loads were estimated to be 35 % of total point sources loads. The effluent nonpoint sources pollutant loads were obtained through the multiplication of generating nonpoint sources loads by effluent ratios based on previous studies. The effluent nonpoint sources loads have the ratio of 26.2% of total BOD effluent loadings, 20.1% of total T-N effluent loadings, and 10.5% of total T-P effluent loadings. For the reduction of nonpoint sources loads in Daechong Reservoir, silviculture, artificial wet land, and grassed waterways could be applied. And untreated livestock waste scattered can result in nonpoint loadings, so required the livestock wastes treatment facilities and purifying facilities together with the management of shed, pasture, livestock waste storage site and composting site. Finally, remote sensing and GIS should be applied to the identification of distribution of water quality, watershed, the location and scale of nonpoint sources, effluent process during rainfall, for more detailed analysis of nonpoint sources.

  • PDF

A Study for Protocol for Heterogeneous Interface in Sensor Networks within Water Restore Facilities (수질복원시설물 내 센서 네트워크 이기종간 인터페이스용 프로토콜에 관한 연구)

  • Kim, Chan;Shin, Jaekwon;Cha, Jaesang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.5
    • /
    • pp.255-260
    • /
    • 2012
  • Currently, the management system of wastewater treatment facility has magnified due to the stringent regulations for the protection of the environment. However, wastewater treatment system is insufficient in wastewater quality monitoring technology in specialized. Above all it aim one-to-one data transmission instead of one-to-n data transmission through sensor and network. And then, it lack compatibility toward communication system between different. Mainly it has observed detecting system of manual system. In this paper, we studied protocol technology about efficient data transmission between sensor and integration interface of water quality detecting interface for automated sensor network integration interface in water restoration facility. Therefore, we proved the possibility of efficient data transmission from communication system of different type through monitoring implementation of sensor network integration interface.

Economic Evaluation of Integrated Operation & Management through Operation Performance Analysis of Sewage Facilities (하수도시설 통합운영 성과분석을 통한 통합운영관리의 경제성 평가)

  • Shin, Jungsub;Chung, Seokhyun;Cho, Byoungog;Lee, Kwanhyung;Kang, Seonhong;Kim, Yongdae;Yoon, Joonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • For economic evaluation of integrated operation to sewage facilities, benefit-cost analysis was performed to watershed sewage works project in 7 watershed areas, 156 facilities. In this study, the cost before and after integrated operation was compared and benefits are calculated from the reduction of operators, increasement treated pollution loads, reduction cost through operation convenience, reduction water consumption through effluent reuse, and improvement of life benefit. The result showed that cost was 8,500million won and benefit was 16,747million won, so benefit was 49% higher than cost. B/C analysis result showed that B/C ratio was 1.97 and it is similar to other researches. The benefits of integrated operation included convenience of data management, increase of emergency response, decrease of complains with sewage which was not reflected numerically, so the benefits of integrated operation were expected much greater than this result

Investigation and Analysis of Water Quality Environmental for Preparing a Natural Learning and Experimental Area in Bukchun and Boundary (북천지역 자연학습 체험단지 조성을 위한 수질 환경성 조사 및 분석)

  • 정종현;최석규;이종현;정덕영;이강우
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.11-22
    • /
    • 2002
  • This study analyzes the river system and water quality conditions of Bukchun in order to establish a basic plan for Preparing a natural learning and experimental area of environmental ecosystem in Bukchun, Gyeongju. It also tries to establish an integrated plan for water management of Bukchun stream based on water contaminants. In addition, after analysing the water quality at 13 points during the non-rainy season, the effluent of municipal wastewater was of relatively better quality with I ~ II grade, below the water quality standard of the river, except in points near Samsung apartments. However, analysing the Hyeongsangang and the effluent of Bomunho and Duckdongdam in rainy season, the water quality was II ~ III grade according to environmental standard. The water Quality of those samples was strongly dependent of non-point source.

Ability and Willingness to Pay for Waste Water Management Services: A Case Study in Lampung Province, Indonesia

  • DJAYASINGA, Marselina
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.8
    • /
    • pp.29-36
    • /
    • 2021
  • This study aims to estimate and calculate the ability to pay (ATP) and the willingness to pay (WTP) of households for wastewater management services (IPAL), the relationship between ATP and WTP, and factors that affect WTP. The location of IPAL construction is in the area of Lampung Province, Indonesia. There are 158 selected households for this study. The study employs a purposive sampling method in which the characteristics of households are classified into 3 categories - former households, newcomer households who had come to this area and have no experience of using water supply services, and newcomer households who have experience of using water supply services such as PDAM. The results of this study are, ATP and WTP values were not always in the same direction. The highest ATP was for newcomer households with experience of water supply services but the WTP was the lowest, on the contrary, the lowest ATP was for former households, but the WTP was the highest. Furthermore, experience and cognitive reference are positively correlated with WTP. Service quality perception, education/knowledge of respondents about environmental conservation, and level of income correlate with WTP.

The control system of sludge amount inspection and discharge materials of outlet water and affiliated water-purification tank (오수/합병정화조의 배출물 제어시스템 연구)

  • 박주식;김건호;오지영;임총규;강경식
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.11a
    • /
    • pp.193-202
    • /
    • 2001
  • The individual rotten water purification tank recently discharges wastewater and sewage through the outlet without purification ability. The outlet water and affiliated water purification tank with microorganism cultivator tank cultivates microorganism and then drops the value BOD, COD of sewage and discharges the quality of water into the outlet. The blower and water pump operating continuously prompts the waste of energy and deterioration of equipment. Each room of deposition tank, foaming tank, microorganism cultivator tank is equipment with the sludge detection senses so it can detect the density of each room. The power-drive plant of the blower and water pump which ate the system cultivating the microorganism must be made as fuzzy controlization (If the sludge amount of each room become higher, the rate of operation of blower and water pump must heighten, on the contrary, in case of row sludge amount, the total handling amount and microorganism handling amount of each room of control. Tank reducing the rate of operation must be DB. At present, the blower amount in proportion to the sludge and oxygen demanding amount has to control. Each mom must be checked outlet level of the outlet, also each room must flow backward discharge materials, and must operate feed-back control until we want to be come as a below value of BOD/COD(10PPM ; KS).

  • PDF