• Title/Summary/Keyword: water and wastewater management

Search Result 458, Processing Time 0.022 seconds

Design Methods of Intermittent Deep Draw Aeration System for Reservoir Water Quality Management (저수지의 수질 관리를 위한 간헐식 양수통형 인공 순환 장치의 설계 방법 개발)

  • Seo, Dongil;Song, Museok;Hwang, Hyundong;Lee, Eun-hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.445-452
    • /
    • 2004
  • Intermittent deep draw artificial circulation system is one of the most widely used destratification systems to control algal bloom in reservoirs in Korea. However, there have been neither theoretical background of design criteria nor operation guide line for efficient application of the system available for such systems. A design method was developed to calculate required compressor capacity and number of circulation units considering physical interactions between stratified water layers and plumes induced by the intermittent deep draw artificial circulation system. The program was tested with data observed in Yeoncho Lake. The results indicated that the developed method can applied in the fields successfully. Further validation processes would improve design and operation methods.

Algal Growth Potential Test (AGPT) in Streams and Embayment of the Okchon Stream Watershed, Korea (옥천천 유역의 하천과 만곡부에서 조류 생장 잠재력 측정)

  • Sin,Jae-Gi;Kim,Dong-Seop;Lee,Hye-Geun;Maeng,Seung-Jin;Hwang,Sun-Jin
    • ALGAE
    • /
    • v.18 no.2
    • /
    • pp.169-176
    • /
    • 2003
  • Algal growth potential test (AGPT) bioassay were conducted to evaluate the stream and reservoir water in the Okchon Stream Watershed during May to September 2002. The water quality of the stream water was clean in the upstream, deteriorating toward the downstream. In particular, SRP and $NH_4$ significantly increased due to treated wastewater. The average AGPT value of the Okchon Stream watershed was 22.4 mg dw ${\cdot}l^{-1}$, with the range of 0- 195.7 mg dw ${\cdot}l^{-1}$. AGPT value was the highest immediately after inflow of treated wastewater, averaging 91.3 mg dw${\cdot}l^{-1}$. AGPT was highly correlated with SRP, $NH_4$ and TIN factors, with P having the greatest effect on the growth of algae. Among N components, $NH_4$ was preferred to $NO_3$ for the growth of algae. Likewise, AGPT was closely linked to meteological and hydrological effects and development of natural phytoplankton. In survey stations, mesotrophic, eutrophic and hypertrophic conditions accounted for 43%, 21% and 36%, respectively. On the other hand, hypertrophic condition focused on the downstream reaches. AGPT was useful in determining not only the limiting nutrients but also the water fertility for the growth of algae. Based on the AGPT results, the management of point sources for water pollution in treated wastewater was important in the protection of aquatic environment in the stream and embayment.

Necessity of Refractory Organic Matters Management in Total Maximum Daily Loads (TMDLs) (수질오염총량관리제에서 난분해성 유기물질 관리 필요성 및 개선방안)

  • Park, Jae Hong;Park, Bae Kyoung;Lee, Jae Kwan;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.3
    • /
    • pp.393-399
    • /
    • 2013
  • To control organic matters, it needs to manage not only biodegradable organic matters but also refractory organic matters. Refractory organic matters from municipal wastewater, industrial wastewater, non-point sources and etc., have been continuously discharged to the near watersheds. It is estimated that the refractory organic matter ratios are continuously increased in waterbody. In watersheds of the Total Maximum Daily Loads (TMDLs), it was investigated that COD/BOD ratios increased in many unit watersheds of the 4 major river basins. The portions COD/BOD ratios increased were found to be a 97% of Geum River unit watersheds, a 81% of Yeongsan/Seumjin River unit watersheds, a 78% of Nakdong River unit watersheds, a 70% of Han River unit watersheds, respectively. Therefore, it has become important for establishment of effective management strategies to control refractory organic matter in watersheds of the Total Maximum Daily Loads (TMDLs). In order to properly manage organic matters including refractory organic matters, the present organic indicator (BOD) has to be converted to TOC (or COD). Compared to COD and BOD, TOC, as a organic matter indicator, is evaluated more appropriate.

Hazardous event analysis in drinking water production using aquifer storage transfer and recovery (대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석)

  • Lee, Sang-Il;Ji, Hyon-Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

A Study on Daily Water Demand Prediction Model (급수량(給水量) 단기(短期) 수요예측(需要豫測)에 대한 연구(硏究))

  • Koo, Jayoug;Koizwui, Akirau;Inakazu, Toyono
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.109-118
    • /
    • 1997
  • In this study, we examined the structural analysis of water demand fluctuation for water distribution control of water supply network. In order to analyze for the length of stationary time series, we calculate autocorrelation coefficient of each case equally divided data size. As a result, it was found that, with the data size of around three months, any case could be used as stationary time series. we analyze cross-correlation coefficient between the daily water consumption's data and primary influence factors. As a result, we have decided to use weather conditions and maximum temperature as natural primary factors and holidays as a social factor. Applying the multiple ARIMA model, we obtains an effective model to describe the daily water demand prediction. From the forecasting result, even though we forecast water distribution quantity of the following year, estimated values well express the flctuations of measurements. Thus, the suitability of the model for practical use can be confirmed. When this model is used for practical water distribution control, water distribution quantity for the following day should be found by inputting maximum temperature and weather conditions obtained from weather forecast, and water purification plants and service reservoirs should be operated based on this information while operation of pumps and valves should be set up. Consequently, we will be able to devise a rational water management system.

  • PDF

A study on operation efficacy and security improvement through structural modification of CCTV network for bansong water purification plant (반송정수장 CCTV망의 구조개선을 통한 운영효율화 및 보안성 개선사례에 관한 연구)

  • Park, Yeunchul;Choi, Hyunju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.2
    • /
    • pp.193-200
    • /
    • 2018
  • Owing to the development in information and communications technologies have improved the technology for high-speed transmission of massive data, which has changed closed-circuit television (CCTV) video transmission technology. In particular, digitization of the CCTV video format and streaming technology has made it possible to minimize transmission loss and integrate video transmission and camera control(pan/tilt). It has also become possible to provide additional services like remote emergency warning broadcasting with just Internet Protocol (IP). However, because of the structural problems of IP, these changes have also brought about the threat of hacking of CCTV monitoring systems. In this study, we propose a methode to optimize network management by examining cases of enhancement of operational efficiency and security by improving the structure of CCTV monitoring network.

The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas (대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책)

  • Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

Development of a system dynamics computer model to assess the effects of developing an alternate water source on the water supply systems management (상수도 시스템 운영에 대한 대체 상수원 개발의 효과를 모의하기 위한 시스템다이내믹스 컴퓨터 모델의 개발)

  • Park, Suwan;Jung, So-Yeon;Sahleh, Vahideh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.755-763
    • /
    • 2014
  • In this paper, a System Dynamics(SD) computer simulation model has been developed to assess the effects of developing and providing an alternate water source. A water service index was also developed to estimate the level of overall customer satisfaction on water supply service. Data from the Busan water supply service and the Korea Development Institute regarding the Nak Dong river bank storage development were utilized during the modeling processes. Some important indicators of the system under study were analyzed by the simulations of development of the alternate water source for Busan. The developed SD model and the water service index can be further utilized as a tool that can assess the extent and timing of an additional service improvement project.

Estimation method of natural rate of rise of leakage in water distribution system (배급수관망에서의 누수복원량 산정방법)

  • Jin, Saemmul;Kim, Kyoungpil;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.299-309
    • /
    • 2019
  • Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.

Auto Calibration of Water Quality Modeling Using NGIS (NGIS자료와 연계한 수질모의 결과의 자동보정)

  • Han, Kun Yeun;Lee, Chang Hee;Kim, Kang Mo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1400-1403
    • /
    • 2004
  • The current industrial development and the Increase of population along Nakdong River have produced a rapid Increase of wastewater discharge. This has resulted in problem of water quality control and management. Although many efforts have been carried out, water quality has not significantly improved. The goal of this study is to design a NGIS-based water quality management system for the scientific water quality control and management in the Nakdong River. For general water quality analysis, QULA2E model was applied to the Nakdong River. A sensitivity analysis was made to determine significant parameters and an optimization was made to estimate optimal values. The calibration and verification were performed by using observed water quality data for Nakdong River. A water qualify management system for Nakdong River was made by connecting the QUAL2E model to ArcView. It allows a Windows-based Graphic User Interface(GUI) to implement all operation with regard to water quality analysis. The modeling system in this study will be an efficient NGIS for planning of water quality management.

  • PDF