• Title/Summary/Keyword: wastewater sampling

Search Result 99, Processing Time 0.025 seconds

Bioindicator at $A_2O$ Wastewater Treatment Plant ($A_2O$ 공법 처리장의 Bioindicator)

  • Lee, Chan-Hyung;Moon, Kyung-Sook
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2005
  • The occurrence and abundance of protozoa at advanced wastewater treatment plant were compared with operating parameters and effluent quality using statistical procedures. In correlation analysis between the distribution of protozoa and operating parameters, the distribution of protozoa was showed the operating condition of plant. Regression analysis between the distribution of protozoa and effluent quality up to 7 days, showed the R-square values of most regression equation were more than 0.6 and constant was higher than slope and could indicate effluent quality from sampling day to 7 days. Once enough data concerning protozoa, operating parameters and effluent has been gathered, the operator has a valuable tool for predicting plant performance and near-future effluent quality based on microscopic examination. Plant operator manipulates operating conditions if he knows near-future data of effluent is deteriorating. Perhaps more importantly it can be used to actually control the plant to adjust the operating conditions to obtain the protozoal populations that have been shown to provide the best effluent quality.

Verification and Calribration of Hydraulic Analysis of Water Supply System Using Fluoride Tracer (불소를 이용한 상수관망 수리해석의 검증 및 보정)

  • Joo, Dae-Sung;Park, No-Suk;Park, Heekyung;Oh, Jung-Woo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.2
    • /
    • pp.76-82
    • /
    • 1998
  • It is necessary to calculate the accurate velocity from the hydraulic model for the reliable prediction of water quality changes in water supply system. To verify the hydraulic analysis of the water supply system, fluoride was used as a tracer to calculate the travel time from the injection point to the sampling points. Results from this field experiment indicate that fluoride can be a good conservative tracer while it showed a little longitudinal dispersion along the pipe lines. And the velocity from the model was verified by these travel times and calibrated by changing the ratio of the unaccountable water. When the ratio of the unaccountable water. When the ratio of the unaccountable water was 20%, the error between the estimation of hydraulic model and the real travel time was minimum.

  • PDF

Study on Sludge Concentration Change in Batch Column (Batch Column에서의 슬러지농도변화에 대한 연구)

  • Park, Suk Gyun;Kang, Seon-Hong;Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.3
    • /
    • pp.443-450
    • /
    • 2006
  • For understanding sludge concentration profile as a function of time, sludge was sampled at each sampling port. When sludge concentration was 3g/L, the vertical sludge concentration distribution was similar to that of 2g/L of sludge concentration. During the early stage of sludge settling, sludge concentration increased remarkably as the sludge interface height in batch column became lower. The higher sludge concentration became, the worse sludge setteability became. Also, the type of sludge settling was influenced with sludge concentration gradient in batch column. In the same concentration, the greater sludge concentration gradient was, the faster sludge interface settled down. And the changing sludge concentrations in a batch settling or a continuous settling were simulated by using the equation of sludge interface height change model.

A study on characteristics analysis of autotrophic denitrification microbial community using sulfur granule (황입자를 이용한 독립영양탈질 미생물 군집분포 특성분석에 관한 연구)

  • Yoon, Su-chul;Joo, Jae-young;Nam, Duck-hyun;Park, Chul-hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.673-679
    • /
    • 2008
  • The representative microorganism of autotrophic denitrification using sulfur granule, oxidizes the reduction from S and performs denitrification by reducing $NO_3{^-}-N$ to $N_2$ gas. The sampling of autotrophic denitrification microorganisms has been performed from foreshore sludge, condensed sludge, and active sludge, but the analysis of autotrophic denitrification microbial community characteristics has been lacking. Based on the separation and identification of each sample using the PCR and DGGE methodologies, many types of sulfuric microorganisms and autotrophic denitrification microorganisms were found.

A study on Water Quality Changes in Distribution System (Factor analysis of deterioration of water quality & Modelling of free chlorine) (상수도 배관망에서의 수질변화에 관한 연구 (수질악화의 영향인자 분석과 잔류염소 모델링))

  • Lee, Hyun Dong;Chung, Won Sik;Moon, Sook Mi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.59-66
    • /
    • 1997
  • Although it produces well-treated water in water treatment plant, water quality at the tap can be changed depending on the state of pipes. It is because water quality deteriorates as plant water passes through pipeline networks. Therefore, the improvement of not only water treatment technology but also O & M of water pipelines is required to supply good water to consumers. The purpose of the study was to obtain the basic data of control technology for water quality in pipes through investigating water quality in distribution system. We selected 11 sampling sites and investigated water quality from plant to endpoint of distribution system. we also simulated decreasing tendency of free chlorine through pipeline network. As the result of water quality test, all parameters were below allowable levels, but some parameters had the possibility of being over levels. So there must be more work to set up proper countermeasure for violable parameters.

  • PDF

Characteristics of Mixing and Coagulation in an Inline Coagulant Mixing System (인라인 응집제 혼화시스템의 혼화 및 응집특성)

  • Yang, Hei-Cheon;Park, Sang-Kyoo;Wang, Seung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3139-3143
    • /
    • 2007
  • The objective of this paper was to investigate the mixing characteristics of an three-stage inline coagulant mixing system experimentally. Wastewater samples of pH 8.5 and initial turbidity 1,000NTU were taken from a site of tunneling work. At the constant dosage, 0.36mL/L, of polymer as coagulant aids, the coagulation efficiency with the dosage of PAC as coagulant was about 4${\sim}$6% at 10 minutes after sampling. In the case of 2 different velocity gradient conditions, the efficiency of turbidity removal was increased about 6.5${\sim}$8% with increasing the dosage of coagulant while, the efficiency was increased about 20${\sim}$21.5% with increasing the dosage of coagulant aids. The efficiency of turbidity removal with the settling time after sampling was about 90% after 1 minute, and the efficiency was about 95% after 5 minutes.

  • PDF

Detection of Polyhydroxyalkanoate-Accumulating Bacteria from Domestic Wastewater Treatment Plant Using Highly Sensitive PCR Primers

  • Huang, Yu-Tzu;Chen, Pi-Ling;Semblante, Galilee Uy;You, Sheng-Jie
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.8
    • /
    • pp.1141-1147
    • /
    • 2012
  • Polyhydroxyalkanoate (PHA) is a class of biodegradable plastics that have great potential applications in the near future. In this study, the micro-biodiversity and productivity of PHA-accumulating bacteria in activated sludge from a domestic wastewater treatment plant were investigated. A previously reported primer set and a self-designed primer set (phaCF1BO/phaCR2BO) were both used to amplify the PHA synthase (phaC) gene of isolated colonies. The new primers demonstrated higher sensitivity for phaC, and combining the PCR results of the two primer sets was able to widen the range of detected genera and raise the sensitivity to nearly 90%. Results showed that 85.3% of the identified bacteria were Gram-negative, with Ralstonia as the dominant genus, and 14.7% were Gram-positive. In addition, Zoogloea and Rhizobium contained the highest amounts of intracellular PHA. It is apparent that glucose was a better carbon source than pentone or tryptone for promoting PHA production in Micrococcus. Two different classes, class I and class II, of phaC were detected from alphaproteobacteria, betaproteobacteria, and gammaproteobacteria, indicating the wide diversity of PHA-accumulating bacteria in this particular sampling site. Simultaneous wastewater treatment and PHA production is promising by adopting the high PHA-accumulating bacteria isolated from activated sludge.

Characteristics of Pollutant Concentration from Livestock Wastewater Effluent Combined with Stormwater Runoff (강우시 및 건기시 축산지역에서 배출되는 오염물질의 유출특성 비교)

  • Tobio, Jevelyn Ann S.;Maniquiz-Redillas, Marla C.;Lee, Yuwha;Kim, Lee-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.896-901
    • /
    • 2012
  • In this research, the levels of concentrations from the junction of effluent from wastewater treatment plant during dry days and combined with runoff from the surrounding 11 ha livestock catchment area during wet days were determined to investigate the relationships of the concentration of various pollutants such as particulates, nutrients and organics originating from point and nonpoint sources. Manual sampling was conducted from October 2008 to December 2011 during dry and wet days. Based on the results, the flow rates and concentrations of most pollutant parameters were increased during wet days. It was found out that the effluent wastewater combined with stormwater runoff has low BOD to TN/TP ratio and high TN/TP to BOD ratio. Therefore, it is needed to employ other treatment methods to effectively manage the wastewater and reduce the pollutant discharge to receiving water bodies.

Spatial Characterization of Water Pollution in the Urban Stream Watershed (Gap Stream), Korea (도시하천(갑천) 유역에서 수질오염의 공간적 특성)

  • Lee, Heung-Soo;Hur, Jin;Jeong, Seon-A;Hwang, Soon-Jin;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.943-951
    • /
    • 2006
  • Spatial distribution of water pollution in the Gap Stream was investigated from October to November, 2005. Sampling was conducted three times including effluents discharged from a wastewater treatment plant (WWTP) and a dam reservoir during the low-flow period. As a typical urban stream, total nitrogen and inorganic nitrogen concentrations increased toward downstream. Ammonia concentration was the highest in the treated water of the wastewater treatment plant and the lowest nitrate concentration was found in the effluent of the dam reservoir. A part of soluble reactive phosphorous (SRP) in total phosphorous was 22~54% in the upstream reach of WWTP in the Gap Stream whereas 68~73% in the downstream reach. Mean chlorophyll-a concentration ranged from 1.6 to $11.0{\mu}g/L$ and it tends to increase toward downstream except for WWTP effluent. As expected, untreated wastewater and WWTP effluent were suggested as the major sources of water pollution in the Gap Stream. In this study, the water pollution of the Gap Stream is a significant undergoing typical eutrophication, caused by excessive phosphorus and nitrogen nutrients from WWTP located in the watershed. As a result, the critical factor for the water pollution was evaluated to dissolved inorganic nitrogen and phosphorus nutrients. Particularly, SRP is a most important for the eutrophication. It suggest that may occur in the most urban streams of Korean peninsula. Therefore, because the necessity of water pollution management in the urban stream, inorganic N and P nutrients should be included as an essential component of water quality criteria in the advanced water quality project of Korean Government by enforcing of water quality assessment and total maximum daily loads (TMDLs).

Distribution of Fecal Sterols and Nonylphenolic Compounds in Sediments from Busan Suyeong Estuary, Impacted by Wastewater Treatment Plant Effluents (하수처리장 방류수역에서 분변계스테롤과 노닐페놀류의 분포 특성)

  • Baek, Seung-Hong;Yoon, Sera;Lee, In-Seok;Hwang, Dong-Woon;Choi, Minkyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.6
    • /
    • pp.1006-1013
    • /
    • 2014
  • Wastewater organic compounds, that is, nonylphenolic compounds (NPs) and fecal sterols, were measured in surface sediments from Busan Suyeong Estuary, where two wastewater treatment plants (WWTPs) are located, to assess contamination from municipal effluents. The NPs analyzed were nonylphenol, and nonylphenol mono- and di-ethoxylates, all synthetic endocrine disruptors. The fecal sterols analyzed were coprostanol (COP), cholestanol, and epicoprostanol. Concentrations of NPs in the sediments ranged from 146 to 3,723 ng/g, and those of COP ranged from 366 to 13,018 ng/g. Their detection in all of the sediments analyzed indicates widespread pollution by municipal effluents. The highest concentrations of NPs and COP were detected at stations close to outfalls of WWTPs. Their levels in sediments are categorized in the higher range of those previously reported in Korean coastal areas. Moreover, in comparison with screening values of NPs in the Netherlands, Norway, and Canada, more than 50% of the sampling stations exceeded the guidelines. This indicates that the estuary may be adversely influenced by municipal effluents.