• Title/Summary/Keyword: wastewater reuse technology

Search Result 80, Processing Time 0.027 seconds

The Background and Direction of R&D Project for Advanced Technology of Wastewater Treatment and Reuse (하.폐수 고도처리 기술개발사업 추진배경과 개발방향)

  • Kim, Ji-Tae;Hwang, Hae-Young;Hong, Byung-Pyo;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.277-289
    • /
    • 2011
  • Since 1980s, wastewater treatment facilities in Korea have been rapidly expanded by 90 percent as the government invested them continuously. Considering social and environmental factors such as the needs of alternative water resources for water shortages, energy saving and new energy production sources for decrease of greenhouse gases, and the demand for the improvement of the water quality in rivers and lakes, advanced technologies in wastewater treatment are essential in the 21st century. In this aspect, new conceptual technology is systematically combined with the advanced treatment technology such as the control and treatment technology of hazardous and toxic material, customized reusing skill, and energy saving/recovery technology. The new R&D project for advanced technology of wastewater treatment and reuse will focus on these advanced technologies which will improve the water quality and foster the competitiveness in world environmental markets, building a solid foundation particularly in the market of developing countries. The project will be divided up into high quality reusing of wastewater, energy self-sufficiency, and integrated management system. It will be carried out for five years, 2011~2015, as Phase I.

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.

Reuse of treated wastewater from steel industry by reverse osmosis membrane: flux decline study

  • Kwon, Tea-Ouk;Lee, Jae-Wook;Moon, Il-Shik
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.199-202
    • /
    • 2004
  • Membrane technology is widely employed as a means of producing various qualities of water from surface water, well water, brackish water and seawater. This is also used in industrial wastewater treatment and its recycling process. A large volume of wastewater is generated by the steel industry. Presently, the treated wastewater from the steel industry cannot be recycled, because some of its components cause either direct or indirect problems.(omitted)

  • PDF

Reduction of waterborne microorganisms in treated domestic wastewater for reuse in agriculture: Comparison between floating media filter and sand filter

  • Semsayun, Chalanda;Chiemchaisri, Wilai;Chiemchaisri, Chart;Patchanee, Nopparat
    • Environmental Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.403-409
    • /
    • 2015
  • This study aims to investigate the use of a floating media filter (FMF) to eliminate waterborne microorganism in treated domestic wastewater for reuse in agriculture. A conventional sand filter (SF) was used concurrently to compare treated water quality. The total/fecal coliforms and somatic coliphage were employed as fecal indicators. The result showed that the FMF was fed with 3 times higher infiltration rate ($15m^3/m^2.h$) than that in the SF ($5m^3/m^2.h$), in which both filters gave similar coliform removal at 6 hours operation. The somatic coliphage elimination tended to increase with operational time for the FMF while that of the SF showed decreasing trend. When a 24 hour continuous operation was applied for the FMF, it showed better removal of somatic coliphage (78%), fecal coliforms (60%) and total coliforms (56%) than that of 6 hour operation. In conclusion, the FMF gave better performance than the SF did by producing a good quality of treated water for agriculture in terms of waterborne microorganisms including turbidity and suspended solids.

Water Quality Changes in Wastewater Effluent from the Unsaturated and Saturated Soil Aquifer Treatment(SAT) Columns Simulating Shallow Aquifer (얕은 불포화 및 포화 대수층을 모사한 SAT 토양칼럼에서의 하수처리장 방류수 처리 수질 변화)

  • Cha Woo-Suk;Kim Jung-Woo;Choi Hee-Chul;Won Jong-Ho;Kim In-Soo;Cho Jae-Weon
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.18-24
    • /
    • 2005
  • Water quality changes of wastewater effluent in the shallow aquifier condition was investigated using laboratory unsaturated and saturated SAT columns for over five months. Average DOC removal was 31.9% in the unsaturated SAT column whereas no removal occurred in the saturated SAT column. Under the shallow aquifer condition, nitrification was not completed in the unsaturated SAT column, releasing residual ammonium nitrogen into the saturated SAT column. Short retention time (one day) in the shallow unsaturated SAT column rendered DO of about 2 mg/L to the influent of the saturated SAT column. Phosphate was not removed at all in the unsaturated SAT column while complete removal was achieved in the saturated column. Consequently, organic and inorganic compounds were removed under the shallow aquifer condition as effectively as was in deep aquifer, except for the release of ammonium and relatively high DO into the saturated SAT column.

Technology Trend on the Increase of Biogas Production and Sludge Reduction in Wastewater Treatment Plants: Sludge Pre-treatment Techniques (하수처리장 바이오가스 생산 증대와 슬러지 감량화에 관한 기술분석: 슬러지 전처리 기술)

  • Cho, Il Hyoung;Ko, In Beom;Kim, Ji Tae
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.413-424
    • /
    • 2014
  • The potential of using the biogas as energy source has long been widely recognised and current techniques are being developed to upgrade the technical quality and to enhance energy efficiency. The objective of this paper is to present efficient and effective pre-treatment methods of increasing the amount of produced biogas in anaerobic digestion of activated sludge treatment process. The paper also presents a review of the effect on biogas production between pre-treated and raw sludge, and also put forward the advantages and disadvantages of each pre-treatment method.

Rice Growth Response and Soil Quality by Domestic Wastewater Irrigation on Rice Paddy Field - Lysimeter experiment - (하수종말처리장 방류수를 논 관개용수로 처리시 벼 생육 및 토양환경 영향 조사 - 라이시미터 재배실험 -)

  • Cho, Jae-Young;Park, Seung-Woo;Son, Jae-Gwon;Park, Bong-Ju;Li, Long-Gen
    • Journal of Korean Society of Rural Planning
    • /
    • v.12 no.2 s.31
    • /
    • pp.49-56
    • /
    • 2006
  • The application of domestic wastewater on rice paddies results in the accumulation of sodium(Na$^+$) to the soil. Excessive concentration of sodium may cause the deterioration of the physical characteristics of the soil, change in the osmosis of the soil, destruction of soil aggregates as well as ion toxicity due to sodium accumulation. Using domestic wastewater as irrigation water should be preceded by measures to prevent or control the soil salinization caused by sodium. Agricultural reuse of domestic wastewater were found not to cause serious problems with food safety due to heavy metals. However, pre-treatment using ultraviolet or ozone is recommended to reduce the number of bacteria and gem and for public health reasons. Using domestic wastewater has shown that reducing the standard application of chemical fertilizers by as much as 50% reduced the harvesting index by only 10%. This study has shown that it is feasible to reuse domestic wastewater on rice paddies. In order to facilitate the application, it is deemed necessary to establish wastewater treatment technologies in the future, to review criteria for recycling domestic wastewater for agricultural purposes such as conditions of soil and cropping system and to resolve conflicts with farmers and public health issues.

Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents (하수방류수의 전처리 조건별 FO막의 운전성능평가)

  • Jeong, Junwon;Kim, Jihoon;Kim, Geonyoub;Park, Junyoung;Kim, Hyungsoo;Kim, Hyungsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.

A Study on the Estimation of the GHGs Emissions to the Reuse of De-ionized Water Production Process in Semiconductor Factory (반도체 생산용 초순수 제조공정의 농축수 재이용에 따른 온실가스 발생량 평가에 관한 연구)

  • Han, Jong-Min;Chung, Jin-Do;Kim, San
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.518-525
    • /
    • 2018
  • In the 21st century, human beings are becoming increasingly concerned about greenhouse gas emissions as the environment changes due to climate change become serious. The temperature of Korea has risen by approximately $1.5^{\circ}C$ from 1904 to 2000, and the climate is changing gradually to a subtropical climate. As a result, the frequency of floods and droughts increases, so that the water available to humans is decreasing every year, and the cost of using city water is rising every year. The reuse of wastewater that is normally abandoned is inevitable. This study examined the monthly data for 6 months of operation by installing a reuse system of concentrated wastewater (Re R/O System) that is generated during the process of manufacturing de-ionized water (DI-Water System) used in semiconductor processing. As a result of the survey, the city water supply saved approximately $2,767m^3$ per month. The average annual greenhouse gas emissions was $1,329.07kg-CO_2$ per month due to the electricity consumption of the water reuse system. On the other hand, because of the reduction in city water supply, the average monthly average of $918.64kg-CO_2$ was reduced, and the greenhouse gas emissions were increased to $410.43kg-CO_2$ per month. If it improves some processes in the water reuse system, the amount of greenhouse gas emissions can be reduced by an average of $254.41kg-CO_2$ per month.