• Title/Summary/Keyword: wastewater reuse

Search Result 281, Processing Time 0.029 seconds

Process Development of Wastewater Containing Silicon Fine Particles by Ultrafiltration for Water Reuse -III. Permeation Characteristics of Pilot Scale Hollow Fiber Membrane Modules- (한외여과에 의한 Si 미립자 함유폐수 재이용 공정개발(III) -Pilot-Scale 중공사막 모듈에 의한 투과 특성)

  • 전재홍;함용규;이석기;박영태;남석태;최호상
    • Membrane Journal
    • /
    • v.9 no.3
    • /
    • pp.185-192
    • /
    • 1999
  • The ultrafiltration characteristics of wafer processing wastewater produced from semicon¬ductor industry was investigated for wastewater reuse. Using the pilot-scale ultrafiltration system con¬taining poly sulfone hollow fiber membranes (MWCO : 10,000, 20,000, 30,(00), the membrane performance, such as flux, rejection rate and concentration factor for flux was examined. The SDhs, turbidity, electrical conductivity and concentration of Si particles were measured, and the possibility of permeate reuse was validated from the experimental results. It was shown that the flux was recovered by the sweeping with air and water effectively. The permeate flux of 30,000 MWCO membrane was about 5 times higher than that of 10,000 and 20,000 MWCO membranes. The concentration of Si particle in the saw wastewater was analyzed 3.8-5.6 mg/$\ell$ and that of Si particle in the permeate was analyzed less than 0.2${\mu}g$/$\ell$. This means the rejection of silicon particle was over 96%.

  • PDF

A Study on the Treatment of Dyeing Wastewater Using the Supernatant after Treatment of Acidic Metal Wastewater (중금속 산폐수 처리 후의 상등액을 이용한 염색폐수처리 연구)

  • 신진명;박장진;김미자;주소영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • Traditionally the supernatant after chemical treatment of metal acid wastewater is discharged in environment. The supernatant can be used as a coagulant as it contains effective metals. The aim of this study is to investigate the feasibility of treatment of dyeing wastewater using the supernatant after treatment by magnesium hydroxide and dolomite($Ca{\cdot}Mg(CO_3)_2$), of acidic metal wastewater. In dyeing wastewater treatment with the supernatant, optimum pH and dosage were determined. COD, turbidity and color were analyzed to evaluate the performance of treatment. In the case of magnesium hydroxide, the optimum dosage was 10%(v/v) for supernatant A and 3%(v/v) for supernatant B. Color, turbidity and COD removal was 99~100%, 85~97% and 43~53%, respectively. In the case of dolomite, the optimum dosage was 10%(v/v) for supernatant A and 3% for supernatant B. Color, turbidity and COD removal was 96~99%, 62~9l% and 52~53%, respectively.

Determinant Factor Analysis for the Spread of Water Reuse (물재이용 활성화를 위한 결정요인분석)

  • Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • The purpose of this study was to survey Suwon citizens over the age of 20 in order to provide basic data on the extent of coverage of the city's water reclamation system and to set guidelines for a policy on water reuse. The survey used a questionnaire with two fields, rainwater use and wastewater recycling, for analyzing factors that influenced water reuse. A factor analysis of 19 questionnaires gave a Cronbach's alpha coefficient greater than 0.4. Factors that influenced rainwater use were environmental protection, water charges, and the risk of climate change. Of the total explanatory power, the share of rainwater use and environmental protection was 39.7% and 28.1% respectively. Environmental protection (explanatory power 24.2%) had an effect on the explanatory power of wastewater reuse. When factors influencing wastewater recycling, like cost of recycling, water management policy, climate change, and suspension of tap water supply were included, the explanatory power of each of these factors went up by 4.3%, 2.8%, 3.3%, and 1.1%, respectively. For more effective wastewater recycling, a water management policy that factors in the above is required, along with a campaign to educate citizens on water management and environment conservation. Additionally, it may be necessary to improve the reliability and the quality of water supply.

A Feasibility Study on Sewage Discharge Water Treatment for Water Reuse by Direct Contact Membrane Distillation (하수처리수 재이용을 위한 직접접촉식 막증발법 적용 가능성 연구)

  • Choi, Yongjun;Choi, Jihyuck;Shin, Yonghyun;Cho, Hyeongrak;Sohn, Jinsik;Lee, Sangho
    • Membrane Journal
    • /
    • v.26 no.1
    • /
    • pp.70-75
    • /
    • 2016
  • The reuse of wastewater is being diffused to manage and develop the water resources. Generally, the treated wastewater is discharged to the river after being treated to meet the effluent quality standard or reused for diverse uses through the reprocessing. And recently, as the reuse of the treated wastewater is activated, the technologies to utilize for the high quality water resources such as industrial water by reusing the wastewater with Membrane Distillation (MD) are under development. In this study, the direct contact membrane distillation (DCMD) process has been applied to treat sewage discharge water for water reuse. The laboratory scale experiment was performed by using a hydrophobic PVDF membrane with the pore size of $0.22{\mu}m$. The influence of operating parameters, such as feed temperature, feed flow rate, feed concentration, on the permeate flux and rejection has been investigated. All filtration tests were conducted till the feed volume reached a concentration factor of 3.0. Thus, the operating period ranged between 19 hr and 49 hr depending on filtration performance. The results showed that above 92% of TN, TP, COD and TOC in the feed could be rejected regardless of an operating condition. The water flux was ranged from 13.8 to 20.3 LMH. The lowest flux was obtained at the operating condition with the feed temperature of $50^{\circ}C$ and feed flow velocity of 500 mL/min while the highest one was measured with $60^{\circ}C$ and 900 mL/min. When the concentration factor reached 3.0, water flux declined by approximately ranged from 14.5% to 33.3%. But the fouling in MD is almost fully reversible, with more than 90% recovery of permeate water flux following a DI water rinse without the addition of chemical cleaning reagents.

Fundamental Study on the Wastewater Reuses for Agriculture (하수처리수의 농업용수 재이용에 관한 기초 연구)

  • Kang, Moon-Seong;Park, Seung-Woo;Kim, Sang-Min
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.393-396
    • /
    • 2002
  • The objectives of the paper are to develop the infra-technologies for reclaiming the effluents from wastewater treatment plants and reusing for agriculture water. The Suwon wastewater treatment plant has been selected for wastewater reuse tests and the water quality and treatment efficiencies are investigated. Three levels of wastewater treatments that are the effluent from the plant, sand filtering, and ultra-violet treatment are applied in the pilot system. The randomized block method was applied to wastewater application to paddy rice with five treatments, three blocks, and two replica. The control was the plots with groundwater irrigation, the other treatments are to use polluted stream flow by pumping, in addition to three wastewater treatments. The block test plots and field plots have been monitored for the water quality, soil pollution, and health hazards during the crop stages.

  • PDF

Treatment of Domestic Wastewater by the Application of Electrochemical Membrane Bioreactor and Generation of Bioelectricity

  • Yadav, Saurabh;Kamsonlian, Suantak;Pal, Shubham
    • Applied Chemistry for Engineering
    • /
    • v.33 no.5
    • /
    • pp.532-537
    • /
    • 2022
  • The need for obtaining treated wastewater that meets high quality standards for discharge or reuse necessitates the use of highly efficient wastewater treatment techniques. In the present study, experiments have been carried out to reduce the concentration level of biological oxygen demand (BOD), chemical oxygen demand (COD), and total dissolved solids (TDS) from the wastewater sample. Treatment of sample of a real municipal wastewater collected from a sewage treatment plant (STP) was carried out in an electrochemical membrane bioreactor (EMBR). The EMBR was operated continuously for five days, and readings were taken at regular intervals. This paper has experimental results conducted in EMBR that indicate reduction of BOD, COD, and TDS levels of up to 32.25%, 29.25%, and 31.93%, respectively. Further, it was observed that a current of magnitude of 0.00752 mA was generated due to the metabolic activities of bacteria present in municipal wastewater, which gradually decreased day by day due to the decay of bacteria.

Safety Evaluation of a Wastewater Reuse for the Farmland Irrigation in Jeju Island (제주지역 하수처리수의 농업용수 재이용 안전성 평가)

  • Son, Yeong Kwon;Rhee, Han-Pil;Kim, Haedo;Choi, Sun Wha;Kim, Jeong Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.21-29
    • /
    • 2015
  • Safety of reclaimed wastewater irrigation needs to be evaluated to promote public health. Quantitative microbial and toxic risk assessment was conducted to identify the level of risk for farmland workers who use reclaimed wastewater and groundwater in Jeju island. Microbial risk through inhalation and ingestion exposure was below acceptable level (less than $10^{-3}$) of $7.07{\times}10^{-6}$ for reclaimed wastewater and $9.99{\times}10^{-8}$ for groundwater irrigation worker. Aggregate exposure risk of Ni, As and Cu was most contributable to overall risk in both reclaimed wastewater and groundwater irrigation plot. High cumulative exposure risk was estimated through non-dietary soil ingestion and dermal contact of soil, due to the high concentration of As, Cu and Ni in farmland soil. Overall toxic risk was $2.68{\times}10^{-4}$ for reclaimed water and $2.39{\times}10^{-4}$ for groundwater irrigation, which could not meet acceptable toxic risk level of $10^{-6}$. Further efforts, such as provide personal protective equipments or public health education, need to be implicated to reduce adverse health risk.

Treatment of natural rubber wastewater by membrane technologies for water reuse

  • Jiang, Shi-Kuan;Zhang, Gui-Mei;Yan, Li;Wu, Ying
    • Membrane and Water Treatment
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2018
  • A series of laboratory scale experiments were performed to investigate the feasibility of membrane separation technology for natural rubber (NR) wastewater treatment and reuse. Three types of spiral wound membranes were employed in the cross-flow experiments. The NR wastewater pretreated by sand filtration and cartridge filtration was forced to pass through the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membranes successively. The UF retentate, which containing abundant proteins, can be used to produce fertilizer, while the NF retentate is rich in quebrachitol and can be used to extract quebrachitol. The permeate produced by the RO module was reused in the NR processing. Furthermore, about 0.1wt% quebrachitol was extracted from the NR wastewater. Besides, the effluent quality treated by the membrane processes was much better than that of the biological treatment. Especially for total dissolved solids (TDS) and total phosphorus (T-P), the removal efficiency improved 53.11% and 49.83% respectively. In addition, the removal efficiencies of biological oxygen demand (BOD) and chemical oxygen demand (COD) exceeded 99%. The total nitrogen (T-N) and ammonia nitrogen (NH4-N) had approximately similar removal efficiency (93%). It was also found that there was a significant decrease in the T-P concentration in the effluent, the T-P was reduced from 200 mg/L to 0.34 mg/L. Generally, it was considered to be a challenging problem to solve for the biological processes. In brief, highly resource utilization and zero discharge was obtained by membrane separation system in the NR wastewater treatment.

The Background and Direction of R&D Project for Advanced Technology of Wastewater Treatment and Reuse (하.폐수 고도처리 기술개발사업 추진배경과 개발방향)

  • Kim, Ji-Tae;Hwang, Hae-Young;Hong, Byung-Pyo;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.277-289
    • /
    • 2011
  • Since 1980s, wastewater treatment facilities in Korea have been rapidly expanded by 90 percent as the government invested them continuously. Considering social and environmental factors such as the needs of alternative water resources for water shortages, energy saving and new energy production sources for decrease of greenhouse gases, and the demand for the improvement of the water quality in rivers and lakes, advanced technologies in wastewater treatment are essential in the 21st century. In this aspect, new conceptual technology is systematically combined with the advanced treatment technology such as the control and treatment technology of hazardous and toxic material, customized reusing skill, and energy saving/recovery technology. The new R&D project for advanced technology of wastewater treatment and reuse will focus on these advanced technologies which will improve the water quality and foster the competitiveness in world environmental markets, building a solid foundation particularly in the market of developing countries. The project will be divided up into high quality reusing of wastewater, energy self-sufficiency, and integrated management system. It will be carried out for five years, 2011~2015, as Phase I.

Application of Coagulation-UF Hybrid Membrane Process for Reuse of Secondary Effluent (하수 2차 처리수 재이용을 위한 hybrid 응집-UF 막분리 공정의 적용)

  • Lee, Chul-Woo;Shon, Jung-Ki;Shon, In-Shik;Han, Seung-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.5
    • /
    • pp.605-612
    • /
    • 2005
  • The objective of this study was to evaluate the factors affecting the optimization of coagulation hybrid UF membrane processes for the reuse of secondary effluent from sewage treatment plant. The experimental results obtained from the UF membrane process showed that organic colloids in the size range of $0.2{\mu}m{\sim}1.0{\mu}m$ caused the most substantial influence on the fouling of UF membrane. When using a coagulation pretreatment to UF membrane, alum dosage of 50mg/L resulted in the least reduction in membrane permeate flux. Also, for the rapid mixing process, in-line mixer type was more efficient for organic removal than back mixer type. Therefore, it may be concluded that coagulation-UF hybrid membrane process comparing to UF alone process showed not only higher removal efficiency of organic matter, but also substantial improvement of permeate flux of UF membrane.