• Title/Summary/Keyword: waste treatment facilities

Search Result 192, Processing Time 0.025 seconds

Development of an Efficiency Calibration Model Optimization Method for Improving In-Situ Gamma-Ray Measurement for Non-Standard NORM Residues (비정형 공정부산물 In-Situ 감마선 측정 정확도 향상을 위한 효율교정 모델 최적화 방법 개발)

  • WooCheol Choi;Tae-Hoon Jeon;Jung-Ho Song;KwangPyo Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.471-479
    • /
    • 2023
  • In In-situ radioactivity measurement techniques, efficiency calibration models use predefined models to simulate a sample's geometry and radioactivity distribution. However, simplified efficiency calibration models lead to uncertainties in the efficiency curves, which in turn affect the radioactivity concentration results. This study aims to develop an efficiency calibration optimization methodology to improve the accuracy of in-situ gamma radiation measurements for byproducts from industrial facilities. To accomplish the objective, a drive mechanism for rotational measurement of an byproduct simulator and a sample was constructed. Using ISOCS, an efficiency calibration model of the designed object was generated. Then, the sensitivity analysis of the efficiency calibration model was performed, and the efficiency curve of the efficiency calibration model was optimized using the sensitivity analysis results. Finally, the radiation concentration of the simulated subject was estimated, compared, and evaluated with the designed certification value. For the sensitivity assessment of the influencing factors of the efficiency calibration model, the ISOCS Uncertainty Estimator was used for the horizontal and vertical size and density of the measured object. The standard deviation of the measurement efficiency as a function of the longitudinal size and density of the efficiency calibration model decreased with increasing energy region. When using the optimized efficiency calibration model, the measurement efficiency using IUE was improved compared to the measurement efficiency using ISOCS at the energy of 228Ac (911 keV) for the nuclide under analysis. Using the ISOCS efficiency calibration method, the difference between the measured radiation concentration and the design value for each simulated subject measurement direction was 4.1% (1% to 10%) on average. The difference between the estimated radioactivity concentration and the design value was 3.6% (1~8%) on average when using the ISOCS IUE efficiency calibration method, which was closer to the design value than the efficiency calibration method using ISOCS. In other words, the estimated radioactivity concentration using the optimized efficiency curve was similar to the designed radioactivity concentration. The results of this study can be utilized as the main basis for the development of regulatory technologies for the treatment and disposal of waste generated during the operation, maintenance, and facility replacement of domestic byproduct generation facilities.

Treatment of Malodorous Waste Air Containing Ammonia Using Biofilter System (바이오필터시스템을 이용한 암모니아 함유 악취폐가스 처리)

  • Lee, Eun Ju;Park, Sang Won;Nam, Dao Vinh;Chung, Chan Hong;Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.391-396
    • /
    • 2010
  • In this research the characteristics of ammonia removal from malodorous waste-air were investigated under various operating condition of biofiilter packed with equal volume of rubber media and compost for the efficient removal of ammonia, representative source of malodor frequently generated at compost manufacturing factory and publicly owned facilities. Then the optimum conditions were constructed to treat waste-air containing ammonia with biofilter. Biofilter was run for 30 days(experimental frequency of 2 times/day makes 60 experimental times.) with the ammonia loading from $2.18g-N/m^3/h$ to $70g-N/m^3/h$ at $30^{\circ}C$. The ammonia removal efficiency reached almost 100% for I through IV stage of run to degrade up to the ammonia loading of $17g-N/m^3/h$. However the removal efficiency dropped to 80% when ammonia loading increased to $35g-N/m^3/h$, which makes the elimination capacity of ammonia $28g-N/m^3/h$ for V stage of run. However, the removal efficiency remained 80% and the maximum elimination capacity reached $55g-N/m^3/h$ when ammonia loading was doubled $70g-N/m^3/h$ for VI stage of run. Thus the maximum elimination capacity exceeded $1,200g-N/m^3/day$(i.e., $50g-N/m^3/h$) of the experiment of biofilter packed with rock wool inoculated with night soil sludge by Kim et al.. However, the critical loading did not exceed $810g-N/m^3/day$ (i.e., $33.75g-N/m^3/h$) of the biofilter experiment by Kim et al.. The reason to exceed the maximum elimination capacity of Kim et al. may be attributed to that the rubber media used as biofilter packing material provide the better environment for the fixation of nitrifying and denitrification bacteria to its surface coated with coconut based-activated carbon powder and well-developed inner-pores, respectively.

Analysis of Drying Efficiency for Circulating and Falling Movements on Indirected Drying Process of Food Waste (음식물류폐기물 간접건조과정에서의 순환 및 낙하이동에 따른 건조효율 평가)

  • Kim, Byung Tae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.106-117
    • /
    • 2012
  • Indirected heating dryer is used as one of the food waste treatment technologies for the production of the drier material supplied to the recycling facilities or end user. This study investigated the effect on drying efficiency for the operation of rotating screw with the circulating and falling movements on indirected drying process of food waste. The screw operating condition showed higher drying efficiency despite of the shorter drying time compared to the screw non-operating condition. The moisture content decreased to 14.4% from the initial moisture content of 77.1% after drying 5 hours in the screw operating condition. On the other hand, in the screw non-operating condition, the moisture content decreased slightly to 35.6% after drying 16 hours. During the drying process, variations of the water evaporation rate and particle size showed different tendencies depending on the moisture content regions. In the higher moisture content region above the glue zone(moisture content of about 50%-60%), the particle size increased and the water evaporation rate reached the highest peak. In the range of glue zone, the particle size maximized while the water evaporation rate decreased sharply. In the lower moisture content region below the glue zone, the water evaporation rate and particle size both decreased at the same time. The particle size distribution was widely ranged from 25.0mm to 0.25mm in the screw operating condition while it was narrowly distributed in the screw non-operating condition from 25.0mm to 3.56mm, especially highly concentrated to 25.0mm. It was regarded that the hygroscopic, capillary and gravitational water evaporated more easily from the intra-particle during the circulating and falling movement caused by the rotating of the screw and the difference of the cohesional force of water within intra-particle depending on the moisture content regions. Comparing the effect of the circulating and falling movement on drying efficiency, the water evaporation rates per time and per weight of dry solid in the screw operating condition were higher about 364% and 356%, respectively, than those of the screw non-operating condition.

Characteristics of organic pollutants in discharged industrial waste in Korea - Focuse on metallic and plastic manufacturing processes and wastewater treatment plants - (국내 사업장 폐기물 중 유기오염물질의 배출특성 연구 - 금속과 플라스틱 제조공정 및 폐수처리시설 중심으로 -)

  • Yeon, Jin-Mo;Kang, Young-Yeul;Kim, Woo-Il;Shin, Sun-Kyoung;Jeong, Seong-Kyeong;Cho, Yoon-A;Kim, Na;Kim, Min-Sun
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.421-428
    • /
    • 2012
  • In this study, PCDD/PCDFs, PAHs and PCBs in wastes from metal, plastic and wastewater treatment facilities were analyzed. The concentrations of PCDD/PCDFs ranged from 7.37~432.20 ng-TEQ/kg in fly ash, 0.51~855.01 ng-TEQ/kg in incinerated ash and 0.37~385.81 ng-TEQ/kg in dust. Dioxin content was lower, compared to data in foreign countries. PAHs concentration was in the range of 0.0075~2.9225 mg/kg for process sludge and 0.0035~1.6716 mg/kg for wastewater sludge, which satisfied all of the two standards (Nap, Ant, B(a)F:4/0.8, Phen, B(a)A:5/1, Flt:10/2.5, B(a)P:4.5/0.9) of the Marine Environment Management Act. PAHs concentration in process sludge and wastewater sludge were slightly lower than those abroad. According to the analysis of seven types of PCBs (in comparison with the first standard, 0.15 mg/kg), concentration was found in the range of 0.0~0.65 mg/kg, while PCB-52, PCB-101, PCB-138, PCB-153 and PCB-180 isomers were detected in excessive value in some machine oil and hydraulic fluid.

A Study on the Medical Services Satisfaction of Cancer Patients in Busan Area (부산지역 암환자의 의료서비스 만족도에 관한 연구)

  • Kim, Byeong-Gun;Yang, Jong-Hyun;Chang, Dong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.1
    • /
    • pp.236-246
    • /
    • 2012
  • Hospital out-shopping by local patients has become more popular. In particular, many cancer patients have visited hospitals in the capital area to get better medical services regardless of how far the hospitals are from their home. However this kind of hospital out-shopping may discontinue medical treatment and cause a waste of medical resources including manpower. In addition, it creates additional economic and social expenses such as caretakers' transportation and lodging expenses. It is necessary to study patients who would take the medical treatment in Busan go to Seoul for better medical services are more satisfied based on objective data. For this, a questionnaire survey has been performed against 223 cancer patients who had a surgery in Busan and 187 patents who had an operation in Seoul. According to the survey, the patients who had an operation in the capital area(Group A) were more satisfied than the patients who had a surgery in Busan(Group B) in terms of convenience facilities, doctors' competence. However the Group A was very dissatisfied in terms of accessibility and satisfaction on overall medical services.

Characteristic of Odorous Compounds Emitted from Livestock Waste Treatment Facilities Combined Methane Fermentation and Composting Process (메탄발효와 퇴비화 공정이 연계된 가축분뇨 처리시설에서 발생되는 악취물질 특성 조사)

  • Ko, Han Jong;Kim, Ki Youn;Kim, Hyeon Tae;Ko, Moon Seok;Higuchi, Takasi;Umeda, Mikio
    • Journal of Animal Science and Technology
    • /
    • v.50 no.3
    • /
    • pp.391-400
    • /
    • 2008
  • Odor management is significantly concerned with sustainable livestock production because odor nuisance is a primary cause for complaint to neighbors. This study was conducted to measure the concentration of odorous compounds, odor intensity, and odor offensiveness at unit process in animal waste treatment facility combined composting and methane fermentation process by an instrumental analysis and direct olfactory method. Ammonia, sulfur-containing compounds, and volatile fatty acid were analyzed at each process units and boundary area in summer and winter, respectively. Higher concentration of odorants occurred in the summer than in the winter due to high ambient temperature. The maximum concentration of odorants was detected in composting pile when mixed manure was being turned followed by inlet, curing, outlet, and screen & packing process. Highest concentration of detected odorous compounds was ammonia ranging from 3.4 to 224.7 ppm. Among the sulfur-containing compounds measured, hydrogen sulfide was a maximum level of 2.3 ppm and most of them exceeded reported odor detection thresholds. Acetic acid was the largest proportion of VFA generated, reaching a maximum of 51 to 89%, followed by propionic and butyric acid at 1.9 to 35% and 1.8 to 15%, respectively. Malodor assessment by a human panel appeared a similar tendency in instrumental analysis data. Odor quotient for predicting major odor-causing compounds was calculated by dividing concentrations measured in process units by odor detection thresholds. In the composting process, hydrogen sulfide, ammonia, dimethyl sulfide, and methyl mercaptan were deeply associated with odor-causing compounds, while the major malodor compounds in the inlet process were methyl mercaptan, hydrogen sulfide, and butyric acid.

Study on Ammonia Emission Characteristic of Pig Slurry (양돈 슬러리의 암모니아 발생 특성에 관한 연구)

  • Lee S.H.;Yun N.K.;Lee K.W.;Lee I.B.;Kim T.I.;Chang J.T.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.1
    • /
    • pp.7-12
    • /
    • 2006
  • Ammonia emission from swine production process originates from three major sources: manure storage facility, swine housing, and land application of manure. Most of the ammonia gas that are emitted from swine production operations is the by-product of aerobic or anaerobic decomposition of swine waste by microorganism. Knowing the ammonia emission rate is necessary to understand how management practices or alternative manure handling process could reduce impacts of this emission on the environment and neighbors. Ammonia gas emission from pig slurry is very difficult to predict because it is affected by many factors including wind speed of slurry surface, temperature or pH of the swine slurry, sort breed differences and classes, and diets. This study was carried out to effects of pH and temperature on ammonia gas emission from growing-finishing pig slurry. Treated far slurry in this study were pH and temperature. Results showed that pH of slurry variable changes 5, 6, 7, 8 upon an addition of NaOH and $HNO_3$, respectively. The temperature of the slurry which was contained in a water bath maintained at increasing levels ranging from 10 to $35^{\circ}C$. Ammonia emission rate of influenced pH and temperature such that the increase in pH or temperature resulted to an increase in ammonia emission. The ammonia gas was not detected at pH 5 and 6. Moreover, at a slurry of pH 8, the ammonia ranged from 28 to 60ppm and 8-29 ppm at slurry pH of 7 while temperature was 13 to $33^{\circ}C$. When slurry pH was>6, the ammonia emission was significantly increased according to rise in temperature in contrast to acid treatment of the pH. There was also a significantly increase in ammonia emission relative to slurry pH of 7 to 8. The above findings showed that to effectively reduce ammonia emission from slurry of growing-finishing pigs, the pH and temperature should be maintained a low levels.

  • PDF

Developing Evaluation Index and Item for Water Environment Improvement of Gyeongin ARA Waterway (경인 아라뱃길의 물환경 개선을 위한 오염원인 평가항목 및 지표 개발)

  • Lee, Kyung-Su;Kim, Tae-Hyeong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.469-482
    • /
    • 2018
  • This research has developed the criteria and index for systematically and objectively assessing the quality of river water by fixing the various factors that affect Gyeongin ARA waterway's water quality through analysis with the Delphi Technique and analytic hierarchy program (AHP) Method. Based on the results, the highest criteria are, in order of importance, physical and environmental factors 28%, administrative factors 26%, natural fixed factors 26% and finally, cultural and social factors 20%. The three dimensions of the criteria show that for the internal physical and environmental factors, the most important are the loss of self-purification capacity, and the external factors are Gulpocheon and the sludge deposit due to Gyulhweon-weir the bridge. The facility factor in management was affected by the coagulation and waste water disposal facilities. The problem for the policy and institutional factors was seen in the regulatory area. The aquatic ecology/ point pollution source for the natural fixed factors show that it is due to the polluted water of Gulpo-cheon and the living environment/ non-point pollution source is shown through the inflow water from other rivers. Cultural and social factors show that the economical causes were due to the cargo and passenger flight operations and the external factors of having a lack of sewage treatment equipment have an importance effect. In order to estimate the order of priority through logical evidence and objectivity, future research must be continued on the evaluation indexes to measure the specific methodology and technique needed to improve the Gyeongin ARA Waterway.

Evaluation of Offshore Water Quality by Bioassay Using the Gametes and Embryos of Sea Urchins (성게 알을 이용한 생물검정에 의한 연안해수 수질평가에 관한 연구)

  • Yu, Chun-Man
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.3 no.3
    • /
    • pp.170-174
    • /
    • 1998
  • The water quality of offshore waters around the Korean coast was evaluated by bioassay using gametes, embryoss and early development systems of a sea urchin species Hemicentrotus pulcherrimus. The results show that despite the inflows of several river systems, the west coast maintain the grade II water. This is thought to be due to the decrease in pollutant input resulting from the purification of inflow rivers (e.g., the control of waste water discharge and the construction of sewage treatment facilities), and the dilution of pollutants by a strong tidal mixing with a large difference between the ebb and flood tides. However, Asan, Hampyong and Chonsu bays, where circulations of water are relatively poor, and the Kunsan and Mokpo harbors which are influenced by pollutants from neighboring cities have shown the grade III water. The south coast has maintain the grade II or III because developments of sea urchins were moderately or strongly inhibited. Also, Kangjin, Duekryang, Kwangyang, Masan, and Jinhae bays where water circulations are relatively poor, show the grade III water, with strong inhibitions of the early development of sea urchins. The east coast has maintained the grade I and II due to monotonous coastlines and smooth circulation of sea water. However, Chongcho Lake shows the worst water quality due to the breakwater which is constructed to maintain port functions.

  • PDF

A Fundamental Study on the Adsorption Capacity of Heavy Metals by Earthworms Cast (지렁이 분변토의 중금속흡착능에 관한 기초연구)

  • Son, Hee-Jeong;Kim, Hyeong-Seok;Song, Young-Chae;Sung, Nak-Chang;Kim, Soo-Saeng
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.2
    • /
    • pp.55-62
    • /
    • 1996
  • The purpose of this study is the evaluation of adsorption capacity of casts for heavy metals comparing with the activated carbon. The casts was obtained from vermicomposting of the mixed organic sludges which were generated from the treatment facilities for leather wastewater and cattle wastewater. The physico-chemical characteristics of cast was investigated. Also, the batch adsorption experiments of cast and activated carbon for heavy metals were carried out, and the results were analyzed by Freundlich isotherm. The buffering capacity to the acidic wastewater was founded in the cast, and the cation exchange capacity of cast impling adsorption capacity for soluble substances was evaluated as about 55me/100g. Those were implied that the cast have a large potential as a good adsorbent for soluble pollutants in wastewater. From the results of batch experiments, the removal efficiencies of tested various heavy metals including Pb, Cu, Cd, and Cr were very high value as 89-98% for the activated car-bon, and 80~95% for the casts except for Zn. The adsorption equilibriums for the two materials were achieved within 90 minutes. The order of preferable metals in the adsorption was found to be Pb>Cu>Cd>Cr>Zn on the cast and to be Pb>Cd>Cu>Cr>Zn on the activated carbon, respectively. From the above results, it might be con-cluded that cast is effectively available as a good adsorbent to treating the heavy metal bearing wastewater.

  • PDF