• Title/Summary/Keyword: waste treatment facilities

Search Result 192, Processing Time 0.023 seconds

Treatment of Malodorous Waste Air by a Biofilter Process Equipped with a Humidifier Composed of Fluidized Aerobic and Anoxic Reactor (폐가스 가습조(유동상호기 및 무산소조)를 포함한 바이오필터공정을 이용한 악취폐가스의 처리)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.85-95
    • /
    • 2018
  • In this research, a biofilter system equipped with a biofilter process and a humidifier composed of a fluidized aerobic and an anoxic reactor, was constructed to treat odorous waste air containing hydrogen sulfide, ammonia and VOC, frequently generated from pig and poultry housing facilities, compost manufacturing factories and publicly owned facilities. Its optimum operating condition was revealed and discussed. In the experiment of complex feed, the ammonia of fed-waste air was removed by ca. 75% and more than 20% at the stage of the humidifier and the biofilter, respectively. The toluene of the fed-waste air was removed by ca. 20% and more than 70% at the stage of the humidifier and the biofilter, respectively. Therefore the water-soluble ammonia and the water-insoluble toluene were treated mainly at the stage of the humidifier and the biofilter, respectively. In addition, hydrogen sulfide was almost absorbed at the stage of the humidifier so that it was not detected at the biofilter process. In the experiment of ammonia-containing feed, the ammonia of fed-waste air was removed by ca. 65% and 35% at the stage of the humidifier and the biofilter, respectively. Its removal efficiency of ammonia at the stage of the humidifier was 10% less than that in the experiment of complex feed, due to no supply of such carbon source as toluene required in the process of denitrification. In the experiments of complex feed, ammonia-containing feed with and without (instead, glucose) the addition of yeast extract, the absorption rates of ammonia-nitrogen were ca. 0.28 mg/min, 0.23 mg/min and 0.27 mg/min, respectively. The corresponding denitrification rates in the anoxic reactor were 0.42 mg/min, 0.55 mg/min and 0.27 mg/min, respectively. In addition, in the modeling of bubble column(the fluidized aerobic reactor of the humidifier) process, the value of specific surface area(a) of bubbles multiplied by enhanced mass transfer coefficient (E $K_y$) was evaluated to be 0.12/hr.

A Study on Investigate the Suitability of ${NH_4}^+$ Applications of Food Waste Water Instead of Urea in the Incineration of Municipal Solid Waste (생활폐기물 소각시 요구되는 요소수의 대체물질로 음식물 폐수 속의 암모니아 적용에 관한 연구)

  • Go, Sung Gyoo;Cho, Yong Kun;Lee, Young Shin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.97-105
    • /
    • 2012
  • This study examined for possibility of the food wastewater incineration treatment method as one of overland treatment method by incineration through liquefied spray of food wastewater when incinerating domestic wastes under operation and for the relationship, etc of air discharge material discharged in incineration, and the results of study are as follow: The food wastewater as one of overland treatment method was analysed 94-96% of moisture contents. Temperature of incinerator outduct during mixed incineration of food wastewater with MSW was average $897^{\circ}C$ and incineration of only MSW was $925^{\circ}C$. Temperature of the mixed incineration of food wastewater was dropped about $28^{\circ}C$ by incineration of only MSW. Concentration of nitrogen oxides(NOx) among air discharge gases was studied by 50ppm, 46ppm when inputting $200{\ell}/hr$, $300{\ell}/hr$ into the incinerator as the quantity of food wastewater. In the mixed incineration of food wastewater, generation speed of scales in the inside of a tubular exhaust gas boiler became rapid and the scale generation quantity became large but the exhaust gas boiler normally operated since scales were removed in cleaning of the tube with a compressive air cleaning facility and there was no opening clogging phenomena in a filter cloth of the filtering dust collector. The overland treatment method, not ocean dumping of food wastewater can be proposed as a technology since mixed incineration of food wastewater with MSW in the existing domestic waste incineration plant is possible, and operation costs of the incineration facility were reduced since use of chemicals such as ammonia and urinary hydrogen ion excretion, etc used in incineration facilities for removing nitrogen oxides(NOx).

Effect of Process By-products on Food Wastes Treatment Costs (공정부산물이 음식물쓰레기 처리비용에 미치는 영향 분석)

  • Yoo, Kee-Young;Yi, Sora
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.3
    • /
    • pp.110-116
    • /
    • 2002
  • The aim of this study was to analyze food waste treatment cost and to estimate effect of by-product, such as wastewater and foreign materials, on amount cost. In cost analysis, man power and facility capacity are fixed, whereas operation cost, by-product treatment and et, al. are varied by treatment methods. The rate of by-product treatment cost in amount cost are between 5% and 39%. The methods which consume large electric power or generate much wastewater showed higher rate of by-product treatment cost in range of 14 to 39%. On the other hand, the methods which have simple process showed lower rate in range of 5 to 11%. Thus, this study recommend that by-products should be treated in sewage treatment facilities or landfill sites to prevent illegal disposal of by-products or to reduce burden of by-product from private sectors.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Preliminary trials on effectiveness of MTR(Mass Transfer Reactor) system in aerating fish stocks

  • Mock Huh;Kim, Boo-Gil
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.1
    • /
    • pp.23-31
    • /
    • 1999
  • An advanced mobile technology is described for saturating water with oxygen. The MTR(Mass Transfer Reactor) is 2~10 times more effective in dissolving oxygen in water compared to most other systems used in aquaculture, because it can generate extremely small(0.005~0.05mm) bubbles. New fish farming facilities could make use of this technology to build deeper ponds for raising multiple species with optimized conditions for DO(dissolved oxygen), food, light, etc. The proposed technology offers higher DO levels with minimal operating costs. It is easy to use and maintain, with a high reproducibility. Accordingly, the MTR can be industrially applied in the treatment of fish waste and reduction of water consumption during fish farming.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Priority Assessment for Remediation of Heavy Metals Closed/Abandoned Mine Areas Using Pollution Indexes

  • Kim Hee-Joung;Yang Jae-E.;Park Byung-Kil;Kong Sung-Ho;Lee Jai-Young;Jun Sang-Ho
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.183-193
    • /
    • 2006
  • Several metalliferous and coal mines, including Seojin and Okdong located at the Kangwon province, were abandoned or closed since 1989 due to the mining industry promotion policy and thus disposed an enormous amount of mining wastes without a proper treatment facilities, resulting in water and soil pollution in the downstream areas. However, no quantitative assessment was made on soil and water pollution by the transport of mining wastes such as acid mine drainage, mine tailing, and rocky waste. In this research, total and fractional concentrations of heavy metals in mining wastes were analyzed and accordingly the degree of water and soil pollutions in the stream area were quantitatively assessed employing the several pollution indices. Concentrations of Ni, Cd, and Pb in soils near the abandoned coal mine areas were 1,240.0, 25.0 and 1,093.0 mg/kg, respectively, and these concentrations were higher than those in soils near the closed metalliferous mine areas. Also Cu concentrations in soils near the tailing dams were about 1967 mg/kg, which is considered as very polluted level. Results demonstrated that soil at the abandoned mine areas were highly contaminated by AMO, tailing, and effluents of the mining wastes. Therefore, a prompt countermeasure on the mining waste treatment and remediation of the codntaminated water and soil should be made to the abandoned or closed metalliferous and coal mines located at the abandoned mine area.

  • PDF

Recycling of Hydroponic Waste Solution for Red Pepper (Capsicum annum L.) Growth (고추재배를 위한 시설하우스 폐양액의 재활용)

  • Park, Chang-Jin;Kim, Kyung-Hee;Yoo, Kyung-Yoal;Ok, Yong-Sik;Yang, Jae-E.
    • Korean Journal of Environmental Agriculture
    • /
    • v.24 no.1
    • /
    • pp.24-28
    • /
    • 2005
  • Waste of the hydroponic solution from the plastic film house cultivation was recycled to grow the red pepper(Capsicum annum L.) in upland fields as supplement for plant nutrients and irrigation sources. Application of hydroponic waste solution increased the pH and EC of the soils, coupled with the increases in the concentrations of exchangeable cations(Ca, Mg, and K), total nitrogen, $NH_4-N,\;and\;NO_3-N$. Growth and yield of red pepper were highest when the treatment of chemical fertilizer(70%) was combined with hydroponic waste solution(30%). Amounts of the daily producing hydroponic waste solution were 2,880 L $ha^{-1}\;day^{-1}$ from the experimental facilities and this could irrigate $409.86m^2$ of area to compensate for the amount of water loss by evapotranspiration(3%). The overall results demonstrated that hydroponic waste solution could be recycled as plant nutrients and irrigation water resources for enhancing soil fertility and environmental quality.

Principle and Application of Biofiltration (바이오필터 기술의 원리와 적용에 관한 고찰)

  • Namkoong, Wan;Park, Joon-Seok;Lee, Noh-Sup
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.1
    • /
    • pp.60-68
    • /
    • 2000
  • Biofiltration is an environmentally-sound technology for elimination of VOCs and odorous compound from low-concentration, high-volume waste gas streams because of its simplicity and cost-effectiveness. It can be appled to the treatment of gases from publicly owned treatment works, composting facilities, landfill sites, and soil vapor extraction systems. The ability to design an effective biofilter system involves a combination of fundamental biofilter knowledge, practical experience, and bench- and pilot-scale testing. The objective of this paper was to review principle, design parameters, operational conditions, case studies, and economy of biofiltration through literature.

  • PDF

The Cultural and Environmental Unsoundness of the Chinese Public Squatting-Type Toilet: A Case Study toward a Sustainable Excreta Treatment System

  • Chang, Jin-Soo
    • Environmental Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.131-138
    • /
    • 2014
  • The inconvenient truth of sustainable public squat toilet culture varies among nationalities. This culture may be comfortable to the people of China, yet uncomfortable to the non-Chinese, according to the adequate environmental management in Yanbian Korean Autonomous Prefecture (YKAP), northern China. We conducted a series of field surveys and individual interviews (Chinese n = 1,000 and non-Chinese [foreign visitors] n = 100) on several aspects of the public squat toilet: structural properties, waste disposal methods, important factors, and overall satisfaction level. The significant factors in response to the public squat toilets were cleanliness, odor, toilet paper, temperature, soap, other facilities, and presence of cubicles. These factors should be policy priorities of the local government. In addition, 66.2% of Chinese and 91% of foreign visitors desired type E toilets (two full-high partition walls and a door). The results illustrate the nature of a sustainable and beautiful approach to the culturally and environmentally sound management of various types of public squat toilet in YKAP. The government needs to focus on the future-oriented and excreta treatment management of the sustainable toilet culture for residents and visitors of YKAP.