• 제목/요약/키워드: waste glass bead

검색결과 8건 처리시간 0.02초

폐유리 경량골재의 표면 거칠기에 따른 모르타르의 미세구조적 특성 (Microstructural properties of mortar as a surface roughness of waste glass bead)

  • 편수정;김규용;최병철;김문규;지성준;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.139-140
    • /
    • 2023
  • This study aims to determine the microstructural characteristics of waste glass beads, a lightweight aggregate manufactured from waste glass powder, when incorporated into mortar in order to examine its usability depending on the particle shape.

  • PDF

악취 및 VOC를 함유한 폐가스의 광촉매 처리: 1. 처리효율에 대한 광촉매담체 다공성의 영향 (Treatment of Waste Air Containing Malodor and VOC: 1. Effect of Photocatalyst-carrying Media Porosity on the Photocatalytic Removal Efficiency of Malodor and VOC of Waste Air)

  • 이은주;박혜리;임광희
    • Korean Chemical Engineering Research
    • /
    • 제50권6호
    • /
    • pp.945-951
    • /
    • 2012
  • 광촉매반응기의 충전제로서 glass bead-광촉매담체를 control로 하고 다공성의 silica-based 광촉매담체를 사용하였을 때의 악취 및 VOC를 함유한 폐가스의 광촉매 처리효율에 대한 광촉매담체 다공성의 영향평가를 수행하였다. 다공성의 silica-based-광촉매담체의 광촉매 코팅량은 $1,716.3{\mu}g/cm^2$로서 nonporous glass bead(control)에 담지된 광촉매코팅량인 $670{\mu}g/cm^2$ 값의 약 250%이었다. Porous silica-based 담체가 충전된 광촉매반응기의 황화수소 및 톨루엔 제거효율은 각각 22% 및 82%로서, glass-bead 담체가 충전된 UV/광촉매반응기의 경우의 황화수소 및 톨루엔 제거효율인 각각 19% 및 53%와 비교하였을 때에 황화수소의 경우는 약 16% 증가하였고 톨루엔의 경우는 약 55% 증가하였다. 따라서 다공성의 silica-based 광촉매담체를 사용함으로써 황화수소와 톨루엔의 동시처리효율을 각각 제고하였고, 처리효율의 제고율은 황화수소보다 톨루엔의 경우가 3.4배 높았다.

악취 및 VOC를 함유한 폐가스의 광촉매 처리: 2. 광도의 폐가스 처리효율에 대한 영향 (Treatment of Waste Air Containing Malodor and VOC: 2. Effect of Light-intensity on the Photocatalytic Removal Efficiency of Malodor and VOC of Waste Air)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제50권6호
    • /
    • pp.952-959
    • /
    • 2012
  • 환형 광촉매반응기 외경지지체의 반사막에 의한 광촉매반응기시스템의 광도를 제고함으로써 개선된 광촉매반응기에 의한 악취성분 및 휘발성 유기화합물을 동시 포함한 폐가스의 처리를 수행하였다. 그리고 광도 제고가 각 운전조건에서의 폐가스처리효율에 미치는 영향을 조사하였다. 광촉매 코팅된 nonporous glass bead 담체와 porous silica-based 담체를 각각 광촉매반응기에 충전하였을 때에 반사필름이 부착된 개선된 광촉매반응기 외경에서 측정한 광도는, 반사필름이 부착되지 않아서 광도가 제고되지 않은 광촉매반응기보다 각각 30.1%와 28.5% 증가하였다. Porous silica-based 담체를 충전한 개선된 광촉매반응기의 제거효율에 대한 제고효과는 약 2~3%이었다. 그러나 glass-bead 담체를 충전했을 때에 개선된 광촉매반응기의 제거효율 제고효과는 미미하였다. Porous silica-based 담체가 충전된 개선된 광촉매반응기인 최적화 광촉매반응기의 경우의 황화수소 및 톨루엔 제거효율은 nonporous glass bead가 충전되고 반사막이 없는 광촉매반응기 경우의 제거효율인 각각 19%와 53%보다 각각 약 26%와 약 60%의 증가율을 보였다. 반사막 필름표면의 roughness가 종래의 상업용 거울의 roughness보다 4배 정도 컸으나, 향후 개선된 광촉매반응기의 반사막의 roughness를 개선할 경우에 광도 개선효과가 더욱 커져서 이에 따른 악취 및 VOC를 함유한 광촉매 처리효율이 더욱 제고되리라 예상된다.

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

폐유리발포비드를 혼입한 고강도 시멘트 복합체의 수화 특성 (Hydration Properties of High-strength Cementitious Composites Incorporating Waste Glass Beads)

  • 편수정;김규용;이상수;남정수
    • 한국건설순환자원학회논문집
    • /
    • 제10권1호
    • /
    • pp.74-79
    • /
    • 2022
  • 본 연구에서는 고강도 콘크리트 및 시멘트 복합체의 밀실한 내부 구조로 인한 급격한 내부 습도 저하 및 수화도 저하 등의 영향을 파악하고자 하였다. 내부 Si 수화도 변화 검증을 위해 폐유리발포비드를 경량골재로 사용하였으며, 중장기에 걸쳐 내부 미반응 수화물의 저감 및 수화물 형성 경향을 파악하였다. 폐유리발포비드는 5, 10, 20 % 혼입되었으며 프리웨팅하여 사용하였다. 폐유리발포비드의 혼입률이 증가함에 따라 강도는 감소하는 경향을 보였다. 이와 함께 XRD 분석, TGA 분석 및 Si NMR 분석을 통해 프리웨팅된 폐유리발포비드의 혼입량이 내부에 증가할 때, 페이스트에 수분이 공급되는 것으로 내부 Si의 수화 정도는 달라지는 것으로 판단된다.

태양광/자외선/이산화티타늄($TiO_2$)을 이용한 에너지 절약형 광촉매 반응 처리시스템 개발 (Development of Wastewater Treatment System by Energy-Saving Photocatalyst Using Combination of Solar Light, UV Lamp and $TiO_2$)

  • 김현용;양원호
    • 한국환경보건학회지
    • /
    • 제29권1호
    • /
    • pp.51-61
    • /
    • 2003
  • Pollution purification using titanium dioxide (TiO$_2$) photocatalyst has attracted a great deal of attention with increasing number of relent environmental problems. Currently, the application of TiO$_2$ photocatalyst has been focused on purification and treatment of waste water. However. the use of conventional TiO$_2$ powder photocatalyst results in disadvantage of stirring during the reaction and of separation after the reaction. And the usage of artificial UV lamp has made the cost of photocatalyst treatment system high. Consequently, we herein studied the pilot-scale design to aid in optimization of the energy-saving process for more through development and reactor design by solar light/UV lamp/ TiO$_2$system. In this study, we manufactured the TiO$_2$sol by sol-gel method. According to analysis by XRD, SEM and TEM, characterization of TiO$_2$ sol were nano-size (5-6 nm) and anatase type. Inorganic binder (SiO$_2$) was added to TiO$_2$ lot to be coated for support strongly, and support of ceramic bead was used to lower separation rate that of glass bead The influences were studied of various experimental parameters such as TiO$_2$ quantity, pH, flow rate. additives, pollutants concentration, climate condition and reflection plate by means of reaction time of the main chararteristics of the obtained materials. In water treatment system, variable realtor as solar light/ or UV lamp according to climate condition such as sunny and cloudy days treated the phenol and E-coli(Escherichia coli) effectively.

공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구 (Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors)

  • 김진기;유성환;임봉수
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

염색산업단지 종합폐수처리용 재순환 통합시스템 (Recirculating Integrated System for the Treatment of Authentic Integrated-textile-dyeing Wastewater from Dyeing Industrial Complex)

  • 이은주;임광희
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.837-845
    • /
    • 2017
  • D염색공단의 폴리에스테르 알카리 감량폐수 및 호발폐수가 혼합된 실제 종합염색폐수를 처리하기 위하여 D염색공단의 종합폐수처리장 반송슬러지를 고정한 폐타이어담체를 충전한 재순환 유동상 바이오필터와 소성된 $TiO_2$ 코팅-glass bead를 광촉매담체로 적용한 UV/광촉매반응기를 결합한 재순환 통합시스템을 구축하여 운전하였다. 그 결과로서 재순환 통합시스템의 총 $COD_{cr}$ 제거율과 총 색도 제거율 추이는 각각 약 81% 및 55% 정도를 유지하였다. 이러한 재순환 통합시스템의 총 $COD_{cr}$ 및 총 색도 제거율의 제고효과는 각각 최대 약 7% 및 3%로 평가되었다. 재순환 통합시스템의 유동상 바이오필터 및 광촉매반응공정은 총 제거율에 대한 상대기여도로서 각각 총 $COD_{cr}$ 제거율의 약 94% 및 6%를 처리하고, 총 색도 제거율의 약 86% 및 14%를 처리하였다. 이와 같이 재순환 통합시스템의 광촉매반응공정에서는 총 제거율에 대한 색도 제거율의 상대기여도가 $COD_{cr}$ 제거율의 상대기여도보다 약 2.4배 정도 컸다. 따라서 본 연구의 재순환 통합시스템에서 광촉매반응공정은 $COD_{cr}$ 제거보다 아조결합과 같이 염료에서 색을 나타내는 화학결합을 깨는 역할에 더욱 효율성이 있었다. 또한 본 연구의 재순환 통합시스템에서 각 단위공정들의 $COD_{cr}$ 및 색도 제거율이, 재순환 통합시스템의 총 $COD_{cr}$ 및 색도 제거율에 미치는 영향에 대한 모델식과 대수적 상관관계를 구하고 분석하였다.