• Title/Summary/Keyword: wall-covering

Search Result 83, Processing Time 0.025 seconds

A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel (중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.91-98
    • /
    • 2011
  • This study is about fire resistance performance of wood framed lightweight wall including a middle lintel as a traditional wall form in Korea. The target wall is non-loadbearing system which constructed with $38{\times}89$ mm ($2"{\times}4"$) wood frame and fireproof gypsum board covering, including a middle lintel made of $150{\times}150$ mm section glue-laminated timber. As a test results, all specimens have showed fire resistant performance over 90 minutes and tests were maintained until flame occuring on Specimen-l, 2, 3 at 91 min, 97 min and 98 min respectively. Fire resistance of the heat side gypsum board was 45 minutes and charring rate of middle lintel was equivalant with that of usual timber. The wood stud inside wall system showed relatively quick combution characteristic when exposed to high temperature with no temperature rising delaying time caused by moisture evaporation because of the dehydration preceded during the early period of fire side gypsum board resist to heat.

A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack (흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구)

  • Park, Sang-Hui;Sin, Dae-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.9
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

Heat Loss Audit and Assessment of the Greenhouses Using Infrared Thermal Image Analysis (적외선 열화상 분석을 통한 온실의 열손실 진단 및 평가)

  • Moon, Jong-Pil;Yun, Nam-Kyu;Lee, Sung-Hyoun;Kim, Hak-Joo;Lee, Su-Jang;Kim, Young-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.2
    • /
    • pp.67-73
    • /
    • 2010
  • Unlike Urban building, horticultural facilities has a lot of heat loss through plastic or glass covering material which could be much influential to growing plant and consuming energy for heating greenhouse. In many cases, heat loss from a break of cover, a gap of joint sealing, the entrance to greenhouse and windows for ventilation are the main factors considered in calculating the heating load for horticultural facilities. however the normal observation through human eye and digital camera could not recognize where the heat loss occurred. but the infrared thermal image camera with detecting thermal difference could be very effective for noticing heat loss by analyzing infrared thermal image. In this study, greenhouse structure, covering material, internal and external provisions for Horticultural facilities were surveyed in different sites and Infrared thermal camera shooting and image analysis were performed for auditing heat loss from cultivation facilities The results from this study were that unexpected heat loss had been noticed in 7 representative cases of greenhouse such as side wall covered with single or double plastic, and the joint of horizontal thermal curtain, roof without horizontal thermal curtain, entrance to greenhouse, windows for ventilation. the most important factors for keeping heat energy were whether the horizontal thermal curtain with multifold thermal material was installed or not. The internal or external covering using multifold thermal curtain proved to be the most effective ways to keep heat energy from losing through heat transmission, heat radiation. from inside to outside the horticultural facilities.

Comparative Study on Seismic Performance of Masonry Wall Strengthened by FRP Sheet or Steel-Bar Truss System (FRP 시트 및 강봉 트러스 시스템으로 보강된 조적벽의 내진성능 비교 연구)

  • Lee, Hye-Ji;Kim, Sanghee;Yang, Keun-Hyeok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.1-9
    • /
    • 2022
  • In this study, the in-plane and out-of-plane seismic performance of the masonry wall strengthened using the steel bar truss system proposed by Hwang et al. (2021a, 2021b) or using FRP sheets were compared and evaluated. The maximum strength of the masonry wall reinforced with FRP sheets for the in-plane and out-of-plane loading was 71% and 85%, respectively, of that of the non-reinforced masonry wall. Meanwhile, the maximum strength of the masonry wall reinforced with the steel bar truss system was approximately 1.8 times higher than that of the non-reinforced masonry wall. Compared with the FRP sheet method, the steel bar truss system was excellent at improving the maximum load capacity, rigidity, and energy dissipation capacity. However, in the case of a masonry wall reinforced with FRP sheets, the masonry wall was overstrengthened with the FRP sheets covering the entire masonry wall, and it is considered that the overstrengthened specimen experienced sliding failure, resulting in a lower strength than the other specimens. A follow-up study is needed to compare the seismic performance of the specimen involving only a part of the masonry wall reinforced with the FRP sheets and the specimen reinforced using the steel bar truss system.

Usefulness of Partial Muscle Flaps and Combination Method for Coverage of Prosthetic Material in Chest Wall Reconstruction (흉벽 재건에서 합성 물질의 피복을 위한 부분 근피판 조합의 효용성)

  • Ryoo, Suk-Tae;Pyon, Jai-Kyong;Lim, So-Young;Mun, Goo-Hyun;Bang, Sa-Ik;Oh, Kap-Sung
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.228-234
    • /
    • 2011
  • Purpose: Reconstruction of chest wall has always been a challenging problem. Muscle flaps for chest wall reconstruction have been helpful in controling infection, filling dead space and covering the prosthetic material in this challenge. However, when we use muscle flaps, functional and cosmetic donor site morbidities could occur. The authors applied and revised various partial muscle flaps and combination use of them to cover the prosthetic material for the chest wall reconstruction and evaluated the usefulness of partial muscle flaps. Methods: This study included 7 patients who underwent chest wall reconstruction using partial muscle flap to cover prosthetic material from 2004 to 2008. The pectoralis major muscle was used in anterior 2/3 parts of it leaving lateral 1/3 parts of it. The anterior 2/3 parts of the pectoralis major muscle were used while lateral 1/3 parts were left. In case of the rectus abdominis muscle flap, we used upper half of it, or we dissected it around its origin and then advanced to cover the site. The latissimus dorsi muscle flap was elevated with lateral portion of it along the descending branch of the thoracodorsal artery. If single partial muscle flap could not cover whole prosthetic material, it would be covered with combination of various partial muscle flaps adjacent to the coverage site. Results: Flap coverage of the prosthetic material and chest wall reconstructions were successfully done. There occurred no immediate and delayed post operative complications such as surgical site infection, seroma, deformity of donor site and functional impairment. Conclusion: When we use the muscle flaps to cover prosthetic material for chest wall reconstruction, use of the partial muscle flaps could be a good way to reduce donor site morbidity. Combination of multiple partial flaps could be a valuable and good alternative way to overcome the disadvantages of partial muscle flaps such as limitation of volume and size as well as flap mobility.

Muscle Flap Operation in Complicated Bone Tuberculosis Infection -A case report- (골감염을 동반한 결핵 감염에서의 근판 전이술 -치험 1례)

  • 허진필
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.89-91
    • /
    • 1998
  • Tuberculosis infection is wide spread disease and makes troublesome complications in some cases. A 50 - year old male visited Andong Hospital with coughing and sputum, dyspnea on exertion, bulging left anterior chest wall mass. Chest X-ray showed right pleural effusion, both side streaky infiltraion, and pleural thickness in apex. Chest CT scan showed bone destruction of left clavicle head, manubrium and large abscess pocket in pectoralis muscle. In May 1996 he underwent en bloc resection of left upper anterior chest wall including pectoralis major and minor muscle, left clavicle head, manubrium and covering infected skin, then contralateral pectoralis major muscle flap and skin graft was done. Patient shows no evidence of recurrence during follow up.

  • PDF

Left ventricular aneurysm (Two cases report) (좌심실에 발생한 진성심실류 (2례 보고))

  • 이철세
    • Journal of Chest Surgery
    • /
    • v.16 no.2
    • /
    • pp.175-183
    • /
    • 1983
  • Ventricular aneurysm which was first described by John Hunter on 18th century, has been experienced by many surgeons after successful using of cardiopulmonary bypass by Cooley on 1958. According to Gorlin, the definition of ventricular aneyrysm is portion of the ventricle which is not motile at systole (akinesis) or which has paradoxical dilatation at systole(dyskinesis). The ventricular aneurysm is classified to anatomical and functional. The anatomical ventricular aneurysm is devided into true or false again. Average age incidence is ranged from 49 to 60 and male predominance is reported. The cause is ischemic coronary artery disease in almost cases but hypertropoc cardiomyopathy, congenital abscence of myocardium, complication after mitral valvular replacement and trauma may also cause the ventricular aneurysm. Angina pectoris and congestive heart failure are most common clinical manifestations Ventricular tachycardia and systemic embolization are also complained. Using cardiopulmonary bypass, aneurysmectomy alone or combination with coronary artery revasculization are currently done for surgical treatment with steady improvenment of mortality. The first patient was 33 years old man who had true type of ventricular aneurysm on inferior wall the left ventricle near apex with protruded huge organized thrombus. The thromboembolic phenomenon was noted on both lower extremities. Under cardiopulmonary bypass, aneurysmectomy and thrombectomy were done. The aneurysmal orifice was repaired with Teflon buttless suture. The second patient was 30 years old female who had large true type of ventricular aneurysm on inferior wall of the left ventricle. Under cardiopulmonary bypass, aneurysmectomy with repair of aneurysmmal orifice defect by means of double layered Dacron patch was done with reinforce by outer silastic sheet covering. She was discharged from hospoital at post op. 15th day uneventfully.

  • PDF

A Study on the Korean traditional interior space and major elements in contemporary apartment (아파트 내부에 나타난 한국전통 실내 공간의 특성 및 구성 요소에 관한 연구)

  • 오혜경
    • Archives of design research
    • /
    • v.11
    • /
    • pp.72-81
    • /
    • 1995
  • The purpose of this study was investigate the consistency of Korean traditional space in apartment. Fifty-two apartments and its dwellers were selected for field survey research and questionnaire. The major findings were summarized as follows: First, the space layout which has its origin in Korean traditional house was found in contemporary apartment and favored than that of western apartment. Second, among the Korean traditional space characteristics, the openness and closeness were found between the living room and room, living room and dining room, dining room and kitchen. Third, the heating system has been being changed from radiator to on-dol. Also favored finishing materials were revealed on-dol wood flooring and picture window for the living room, jang-pan flooring and Korean lattice window for the master room, wall covering for every wall and ceiling.

  • PDF

Seismic response of combined retaining structure with inclined rock slope

  • Yu-liang, Lin;Jie, Jin;Zhi-hao, Jiang;Wei, Liu;Hai-dong, Liu;Rou-feng, Li;Xiang, Liu
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.591-604
    • /
    • 2022
  • A gravity wall combined with an anchoring lattice frame (a combined retaining structure) is adopted at a typical engineering site at Dali-Ruili Railway Line China. Where, the combined retaining structure supports a soil deposit covering on different inclined rock slopes. With an aim to investigate and compare the effects of inclined rock slopes on the response of combined retaining structure under seismic excitation, three groups of shaking table tests are conducted. The rock slopes are shaped as planar surfaces inclined at angles of 20°, 30°, and 40° with the horizontal, respectively. The shaking table tests are supplemented by dynamic numerical simulations. The results regarding the horizontal acceleration response, vertical acceleration response, permanent displacement mode, and axial anchor force are comparatively examined. The acceleration response is more susceptible to outer structural profile of combined retaining structure than to inclined angle of rock slope. The permanent displacement decreases when the inclined angle of the rock slope increases within a range of 20°-40°. A critical inclined angle of rock slope exists within a range of 20°-40°, and induces the largest axial anchor force in the combined retaining structure.

Influence of Air-tightness on Heat Energy Performance in Post and Beam Building with Exposed Wood Frame

  • Kim, Hyun-Bae;Kim, Se-Jong;Oh, Jung-Kwon;Park, Joo-Saeng;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Han-green building is one of the modernized Korean traditional buildings developed by Korea Forest Research Institute. This building was developed to increase the competitiveness of Korean traditional building using state-of-art technologies; hence Han-green building has the inherent characteristics of traditional building such as exposed wood frame in wall. Because of discontinuity in wall by the exposed wood frame, there is a concern on heat-air leaking in terms of energy performance. In this study, air-tightness of Han-green building was evaluated to investigate the influence of gaps between frames and in-fill walls. Blower door test was carried out to evaluate the air-tightness, and air-change rate (ACH50) was evaluated by averaging four set of pressurization and depressurization test. The air-change rate of Han-green house was 5.91 $h^{-1}$. To improve energy performance of Han-green house, thermal infrared images of Han-green house were taken in winter with heating to find out where the heat loss occurred. It was found that the building lost more heat through gaps between frames and in-fill walls rather than through other parts of this building. After covering all the gaps by taping, the blower door test was performed again, and the air-change rate was improved to 5.25 $h^{-1}$. From this analysis, it was concluded that the heated air can leak through the gaps between frames and walls. Therefore, when one designs the post and beam building with exposed frame, the detail design between frame and wall needs to be carefully dealt. However, Han-green building showed relatively high air-tightness comparing with other country research results.