• Title/Summary/Keyword: wall panels

Search Result 237, Processing Time 0.027 seconds

Field Survey on the Structure and Manure Treatment of Two-Storey and Sawdust Pig Houses in Korea (국내 2층 돈사와 톱밥돈사의 구조 및 분뇨처리 실태조사)

  • Jeong J. W.;Yoo Y. H.;Song J. I.;Kim T. I.;Jeon B. S.;Yang C. B.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2005
  • The farm house structure, ventilation system and manure treatment of two-storey buildings and sawdust pig houses were surveyed and analyzed. Based on the data for ten selected farms in five provinces during eight months, the goal is to eventually establish a standard two-storey pig house. Manure treatments were composting, slurry and activated sludge in two-storey pig houses, while fermentation method was done in sawdust pig house. The depth of sawdust as a litter material were 10 to 60cm, with a duration of 1/2, 1, 3 and 6 months, respectively. The ventilation systems were the mechanical type in two-storey pig houses and natural system in the sawdust pig house. Side wall in the two-storey pig house was enclosed with insulation materials such as block, colored metal sheet and sandwich panels. The minimum ceiling height in the first floor of the two-storey pig house was 2.0m and the maximum was 3.0m. On the second floor, ceiling height ranged from 2.0 to 2.7m. The construction cost in the two-storey systems were $700\~140$, and sidewall curtain systems were $30\~40$ thousand Won/pyung.

  • PDF

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.

The Development of Steel-plate Concrete Panels with Preplaced Lightweight Aggregates Concrete (프리플레이스트 경량골재 콘크리트를 사용한 합성형 구조모듈 제작 및 성능 평가)

  • Yoon, Jin Young;Kim, Jae Hong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2017
  • The steel-plate concrete(SC) is used in a form of module assembly construction in the outer wall of nuclear-power plant and LNG containment. Since the steel-plate concrete modules are generally manufactured from the plant, the weight of SC has significantly effect on the total construction cost in the aspect of shipment. Therefore, the use of lightweight aggregates concrete(LWAC), which fill the inside of SC module can be a solution. However, the amount of used lightweight aggregates(LWA) is limited in the use of current concrete mixing process due to the concrete quality problems and it also determines the allowable minimum density of LWAC. In this research, the preplaced casting method is applied because of increasing the volume fraction of LWA significantly, which results from the producing process of pre-packing the LWA in the formwork and filling the interstitial voids between LWA using cement paste grout. The density and compressive strength of selected preplaced LWAC were $1,600kg/m^3$ and 30MPa and it was applied for the mock-up specimens of SC panel. It was used for the 3-point bending test for evaluating its structural performance. The results show that the preplaced LWAC can reduce the density of concrete with the adequate mechanical and structural performance.

Effect of Compaction Method on Induced Earth Pressure Using Dynamic Compaction Roller (진동롤러에 의한 다짐방법이 인접구조물의 다짐토압에 미치는 영향)

  • Roh, Han-Sung
    • International Journal of Highway Engineering
    • /
    • v.3 no.4 s.10
    • /
    • pp.127-136
    • /
    • 2001
  • To increase the structural integrity of concrete box culvert good compaction by the dynamic compaction roller with bi9 capacity is as effective as good backfill materials. It is needed for effective compaction that a compaction roller closes to concrete structure with high frequency. However structural distress of the culvert could be occur due to the excessive earth pressure by great dynamic compaction load. To investigate the characteristics of Induced stress by compaction, a box culvert was constructed with changing cushion materials and compaction methods. Two types of cushion material such as tire rubber chip and EPS(Expanded Polystyrene) were used as cushion panels and they are set on the culverts before backfill construction. Laboratory test result of cushion material says that the value of dynamic elastic modulus of rubber is lesser than that of EPS. On the other hand, material damping of rubber material is greater than that of EPS. In most case, dynamic compaction rollers with 10.5 ton weights were used and vibration frequency was applied 30Hz for the great compaction energy. This paper presents the main results on the characteristics of dynamic earth pressures during compaction. The amounts of induced dynamic pressures$(\Delta\sigma\;h)$ by compaction are affected with construction condition such as compaction frequency, depth of pressure cell, distance between roller and the wall of culvert and roller direction. Based on the measured values dynamic lateral pressure on the culverts, it could be said that orthogonal direction of roller to the length of culvert is more effective to compaction efficiency than parallel direction.

  • PDF

Emission Characteristics of Carbonyl Compounds Depending on Different Finishing Materials in a Wooden House (목조주택 내 마감자재에 따른 카르보닐화합물의 방산특성)

  • Lee, Hee-Young;Park, Sang-Bum;Kang, Young-Suk;Lee, Sang-Min;Park, Jong-Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.12-18
    • /
    • 2009
  • This study was attempted to investigate indoor air quality of a wooden house. Emission characteristics of carbonyl compounds from indoors whose interiors were finished using ecofriendly materials were detected. From the results of the examination, the carbonyl compounds mostly consisted of formaldehyde, acetaldehyde, and hexaldehyde. Especially, formaldehyde accounted for the largest portion of the compounds at 25.6~30.5%. All the rooms except for R2-2 contained formaldehyde less than criteria of indoor air quality of newly-constructed houses. In addition, all the rooms except for room R1-3, contained acetaldehyde more than the level of $48{\mu}g/m^3$ recommended by Japan's Ministry of Health, Labour and Welfare. As a results of the different wall covering, the room R1-1 of Hwangto emitted relatively higher levels of carbonyl compounds than the room R2-1 of phytoncide. In addition, the room R2-2 of the bamboo charcoal panels emitted more carbonyl compounds than the room R1-2. The living room R1-3 of Japanese cypress (Cryptomeria Japonica) emitted lower levels of carbonyl compounds than other rooms.

A Study on the Evaluation and Analysis of Convenient Facilities in Social Welfare Hall through Consideration of the Disabled Person Use (장애인 이용을 고려한 사회복지관 편의시설 평가 및 분석에 관한 연구)

  • Jung, Rye-Hwa;Lee, Wan-Geon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.3
    • /
    • pp.114-121
    • /
    • 2009
  • The number of the disabled is increasing every year. Growing interest in social welfare, but still the disabled person in places is restricted on the activities are due to obstacles. This study proposes an improvement direction through an research and analysis of installation status of convenient facilities in social welfare halls was planned after that the law of increase of convenience for the disabled person is enforced in 1998. This study analyzed nine social welfare halls of seoul including Yongsan-gu(GW), Guro-gu(GD, HW), Yeongdeungpo-gu(SG), Seodaemun-gu(SD), Dobong-gu(DB), Nowon-gu(NS), Seongbuk-gu(WG) and Dongdaemun-gu(JG). The evaluation criteria for the installation of convenient facilities for the disabled person in each social welfare hall based on the law of increase of convenience for the disabled person, and referred to other data. Also, review the criteria for the installation of convenient facilities, and grasp the present situation through the survey of convenient facilities in social welfare halls, and provides the installation standards of convenient facilities. The result are as followings. There were many problems to be improved in approach of the intermediate space, parking lot, entrance of the inside space and corridor that must be installed for the convenience of the disabled. In the intermediate space, the slope of the ramp, curb, induction handle etc. for a safety must be installed. Parking spaces for the disabled must be located closest to the main entrance, an induction marker or the handle, and the attachment of a directional sign etc. must be improved. In the inside space, it is convenient for the disabled person use to install an automatic door and swing door simultaneously at the main entrance. And, the height of the door handle, an induction block, a braille display panels of the appropriate height in the entrance, a braille display in start and end of the stairs handle, the handle of the side wall, the stairs to prevent slippage etc. must be improved in the corridors. The case of the sanitation which is a recommendation item is equipped formally with disabled toilets are difficult to use. Information and other convenience facilities for the disabled person in all the social welfare halls were not considered.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.