• Title/Summary/Keyword: wall decay

Search Result 96, Processing Time 0.029 seconds

Germ Tube Formation of Ascospores of Two Terrestrial Higher Ascomycetes, Hypoxylon mammatum and H. truncatum

  • Lee, Yang-Soo;Han, Sang-Sub;Shin, Jong-Ho;Lee, Young-Mi;Song, Bong-Keun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.10-16
    • /
    • 2000
  • Two wood decay ascomycetes fungi identified as Hypoxylon mammatum and H. truncatum were isolated from backyard of Korea Research Institute of Chemical Technology (KRICT) in Korea. Hypoxylon truncatum is newly recorded as a wood degrader in Korea. Unusual germination mechanisms of ascospores in H. mammatum and H. truncatum are described and illustrated. The differences between two species were noticed on the process of germ tube formation. In the process of germ tube formation, the fast movement to pigmented ascospores activated from their perispores was termed as spore eclosion that was only found in H. mammatum. This sophisticated recognition mechanism indicated the existence of specific eclosion and germ tube formation due to the composition of cell wall layers and their preferable host derive, based on examined two species under a genus. The observation on present study postulates different composition of wall layers of ascospore and different nutrient composition for germination.

  • PDF

The Study of Growth and Photoconductive Characterization of $AgInS_2$ Single Crystal Thin Film by Hot Wall Epitaxy (Hot Wall Epitaxy(HWE) 방법에 의한 $AgInS_2$ 단결정 박막 성장과 광전도 특성)

  • 홍광준
    • Korean Journal of Crystallography
    • /
    • v.9 no.2
    • /
    • pp.96-106
    • /
    • 1998
  • 수평 전기로에서 AgInS2 다결정을 합성하여 HWE 방법으로 AgInS2 단결정 박막을 반절연성 GaAs(100) 위에 성장하였다. AgInS2 단결정 박막은 증발원과 기판의 온도를 각각 680℃, 410℃로 성장하였다. 이때 단결정 박막의 결정성이 10 K에서 측정한 광발광 스펙트럼은 597.8 nm(2.0741 eV) 근처에서 엑시톤 방출 스펙트럼이 가장 강하게 나타났으며, 또한 이중결정 X-선 요동곡선(DCRC)의 반폭치(FWHM)도 121 arcsec로 가장 작게 측정되어 최적 성장 조건임을 알 수 있었다. Hall 효과는 van der Pauw 방법에 의해 측정되었으며, 온도에 의존하는 운반자 농도와 이동도는 293 K에서 각각 9.35×1023개/㎥, 2.94×10-2㎡/V·s였다. AgInS2 단결정 박막의 광전류 단파장대 봉우리들로부터 10 K에서 측정된 ΔCr(crystal field splitting)은 0.15eV, ΔSo(spin orbit coupling)는 0.0089 eV였다. 광전도 셀로서 응용성을 알아보기 위해 감도(γ), pc/dc(photocurrent/darkcurrent), 최대허용소비전력(maximum allowable power dissipation: MAPD), 응답시간(response time)등을 측정한 결과, S 증기 분위기에 열처리한 광전도 셀의 경우 γ=0.98, pc/dc=1.02×106, MAPD=312 mW, 오름시간(rise time)=10.4 ms, 내림시간(decay time)=10.8 ms로 가장 좋은 특성을 얻었다.

  • PDF

Growth of CdSe thin films using Hot Wall Eptaxy method and their photoconductive properties (HWE에 의한 CdSe 박막의 성장과 광전도 특성)

  • You, Sang-Ha;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.344-348
    • /
    • 2004
  • The CdSe thin films wee grown on the Si(100) wafers by a hot wall epitaxy method(HWE). The source and substrate temperature are $600^{\circ}C\;and\;430^{\circ}C$ respectively. The crystalline structure of epilayers was investigated by double crystal X-ray diffraction(DCXD). Hall effect on the sample was measured by van der Pauw method and studied on the carrier density and mobility dependence on temperature. From Hall data, the mobility was increased in the timperature range 30K to 150K by impurity scatering and decreased in the temperature range 150K to 293K by the lattice scattering. In order to explore the applicability as a photoconductive cell, we measured the sensitivity($\gamma$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time. The results indicated that the photoconductive characteristic were the best for the samples annealed in Cu vapor compare with in Cd, Se, air and vacuum vapour. Then we obtained the sensitivity of 0.99, the value of pc/dc of $1.39{\times}10^7$, the MAPD of 335mV, and the rise and decay time of 10ms and 9.5ms, respectively

  • PDF

Growth and optoelectrical properties for $Cd_{1-x}Zn_xS$ thin films byg Hot Wall Epitaxy method (HWE에 의한 $Cd_{1-x}Zn_xS$ 박막의 성장과 광전기적 특성)

  • Lee, Sang-Youl;Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.304-308
    • /
    • 2004
  • The $Cd_{1-x}Zn_xS$ thin films were grown on the Si(100) wafers by a hot wall epitaxy method(HWE). The source and substrate temperature are $600^{\circ}C\;and\;440^{\circ}C$ respectively. The crystalline structure of epilayers was investigated by double crystal X-ray diffraction(DCXD). Hall effect on the sample was measured by the van der Pauw method and studied on the carrier density and mobility dependence on temperature. In order to explore the applicability as a photoconductive cell, we measured the sensitivity($\gamma$), the ratio of photocurrent to darkcurrent(pc/dc), maximum allowable power dissipation(MAPD), spectral response and response time. The results indicated that the photoconductive characteristic were the best for the $Cd_{0.53}Zn_{0.47}S$ samples annealed in Cu vapor compare with in Cd, Se, air and vacuum vapour. Then we obtained the sensitivity of 0.99, the value of pc/dc of $1.65{\times}10^7$, the MAPD of 338mW, and the rise and decay time of 9.7ms and 9.3ms, respectively

  • PDF

THERMAL AND STRUCTURAL ANALYSIS OF CALANDRIA VESSEL OF A PHWR DURING A SEVERE ACCIDENT

  • Kulkarni, P.P.;Prasad, S.V.;Nayak, A.K.;Vijayan, P.K.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.469-476
    • /
    • 2013
  • In a postulated severe core damage accident in a PHWR, multiple failures of core cooling systems may lead to the collapse of pressure tubes and calandria tubes, which may ultimately relocate inside the calandria vessel forming a terminal debris bed. The debris bed, which may reach high temperatures due to the decay heat, is cooled by the moderator in the calandria. With time, the moderator is evaporated and after some time, a hot dry debris bed is formed. The debris bed transfers heat to the calandria vault water which acts as the ultimate heat sink. However, the questions remain: how long would the vault water be an ultimate heat sink, and what would be the failure mode of the calandria vessel if the heat sink capability of the reactor vault water is lost? In the present study, a numerical analysis is performed to evaluate the thermal loads and the stresses in the calandria vessel following the above accident scenario. The heat transfer from the molten corium pool to the surrounding is assumed to be by a combination of radiation, conduction, and convection from the calandria vessel wall to the vault water. From the temperature distribution in the vessel wall, the transient thermal loads have been evaluated. The strain rate and the vessel failure have been evaluated for the above scenario.

Micromorphological Characteristics of Buddhist Temple Woods Treated with Eire-retardant (방염 처리 고목재의 미생물 분해의 미시형태적 특징)

  • Wi, Seung Gon;Kim, Ik-Joo;Park, Young Man;Kim, Yoon Soo
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.27-34
    • /
    • 2001
  • Following the recommendations made by the cultural authorities the wooden cultural properties (WCP) had been treated with fire-retardants for fire protection. However, visual inspections of some of the WCPs treated with fire-retardants showed microbial decay. The work was extended to examine the micromorphological characteristics of the WCPs in a Buddhist temple which had been treated with fire-retardant. Microscopic examination showed the presence of typical soft rot cavities along the length of microfibrils in the secondary wall. Bacterial attack was also observed by scanning and transmission electron microscopy. It is interesting that the decay patterns observed in the Buddhist temple were very similar to those observed in the waterlogged woods. Presumably chemicals in the fire-retardants used rendered the wood susceptible to attack by soft-rot and bacterial decay by causing an increase in the moisture content of wood. Further studies are needed to investigate the effect of fire-retardants used currently on the hygroscopicity and the strength of wood materials in the WCPs. Microbial attacks caused degradation of the secondary cell walls and in some cases also of the middle lamella. In addition, the cell walls in the outer parts of wood were also degraded due to weathering, and cell separation occurred from total disintegration of the middle lamella.

  • PDF

Slab Thickness Calculations on Hot Cell

  • Ha, Yung-Joon;Kim, Seong-Yun;Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.26-36
    • /
    • 1978
  • Numerical computations of radioactivities and decay energies in a spent fuel have been carried out for designing of a hot cell. Optimum wall and window thicknesses that can preserve spent fuel rods for experimental purposes are estimated with burnup rate of 33,000 MWD/T(U) which is nearly maximum from a pressurized water reactor such as the Go-Ri Unit 1. Before putting the spent fuels into a hot cell, it is assumed for thickness estimates of shield materials that they are cooled in a storage tay for several lime intervals. Considered are various types of shield materials through which changing the distances from a source to an observation point is also made.

  • PDF

Comparison of pollutant removal efficiency according to the locations of the supply and exhaust (격리병실내 급배기구 위치에 따른 오염물 제거효율 비교)

  • Won, An-Na
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.

Electron Microscopic Observation on the Decay of the Waterlogged Woods Excavated from Higokri, Pyungtaek (평택 희곡리 출토목재 부후형태의 전자현미경적 관찰)

  • Kim, Soo-Chul;Park, Won-Kyu
    • Journal of Conservation Science
    • /
    • v.23
    • /
    • pp.67-72
    • /
    • 2008
  • This study was conducted to examineboth the type of wood decay and the degree of degradation for the waterlogged woods (Alnus spp. and Fraxinus spp., about 5,700~5,900 year old), which were excavated at Higokri, Pyungteak in the west-coastal region of Korea. The transmission electron microscope (TEM) observation indicated the degradations by soft rot and bacteria were common in both woods. Erosion bacteria attacked gradually and irregularly from the secondary layer to compound middle lamella and often produced the cavity which was similar to soft-rot cavity but much smaller ones. Tunneling bacteria decomposed mainly $S_2$ layer. Though of highly degraded walls, the cells almost kept the original form with intact lignin-rich middle lamella, which were saturated by water. No marine borer's trace indicated that the sealine rise in the western coast of Korean peninsula during the climate optimum period in the holocene might not be high enough to submerge the Higokri area which locates about 2 km from the present sealine.

  • PDF

Combustion Stability Analysis on Hot-firing Test Results of Regenerative Cooling Combustion Chamber (재생냉각 연소기 연소시험의 연소안정성 분석)

  • Ahn, Kyu-Bok;Lim, Byoung-Jik;Lee, Kwang-Jin;Han, Yeoung-Min;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.5
    • /
    • pp.15-20
    • /
    • 2009
  • Hot-firing tests were performed on two 30 tonf-class regenerative cooling combustion chambers, with different injector distribution and wall cooling method. In the paper, the combustion stability test results were analyzed and presented. The pressure fluctuation and stability rating test(SRT) results of the combustion chambers were examined to evaluate combustion stability. The combustion chambers exhibited satisfactory results on combustion stability. The RMS values of the chamber pressure fluctuation were less than 3% of the chamber pressure and the decay time of artificial pressure peaks was measured to be around 10% of the reference decay time. It is interesting that the RMS values of pressure fluctuation in the combustion chamber with film cooling are smaller than those in the chamber with cooling injectors at the periphery row.