• 제목/요약/키워드: wall decay

검색결과 96건 처리시간 0.025초

Snap back testing of unbonded post-tensioned concrete wall systems

  • Twigden, Kimberley M.;Henry, Richard S.
    • Earthquakes and Structures
    • /
    • 제16권2호
    • /
    • pp.209-219
    • /
    • 2019
  • Unbonded Post-Tensioned (UPT) precast concrete systems have been shown to provide excellent seismic resistance. In order to improve understanding of the dynamic response of UPT systems, a series of snap back tests on four UPT systems was undertaken consisting of one Single Rocking Wall (SRW) and three Precast Wall with End Columns (PreWEC) systems. The snap back tests provided both a static pushover and a nonlinear free vibration response of a system. As expected the SRW exhibited an approximate bi-linear inertia force-drift response during the free vibration decay and the PreWEC walls showed an inertia force-drift response with increased strength and energy dissipation due to the addition of steel O-connectors. All walls exhibited negligible residual drifts regardless of the number of O-connectors or the post-tensioning force. When PreWEC systems of the same strength were compared the inclusion of further energy dissipating O-connectors was found to decrease the measured peak wall acceleration. Both the local and global wall parameters measured at pseudo-static and dynamic loading rates showed similar behaviour, which demonstrates that the dynamic behaviour of UPT walls is well represented by pseudo-static tests. The SRW was found to have Equivalent Viscous Damping (EVD) between 0.9-3.8% and the three PreWEC walls were found to have maximum EVD of between 14.7-25.8%.

배급수계통에서 잔류염소 및 THMs 분포 예측에 관한 연구 (Modeling Residual Chlorine and THMs in Water Distribution System)

  • 안재찬;이수원;노방식;최영준;최재호;김효일;박태준;박창민;박현;구자용
    • 대한환경공학회지
    • /
    • 제29권6호
    • /
    • pp.706-714
    • /
    • 2007
  • 본 연구에서는 배급수계통에서 잔류염소와 THMs의 분포를 예측하는 방안을 제시하였다. 잔류염소와 THMs의 등의 수질변화에 대해 현장조사를 실시하였고, 수체와 관벽에 대한 잔류염소 감소계수와 THMs의 생성계수를 산출하여 관망해석에 의한 수질모델링에 적용하였다. 병실험을 통해 잔류염소 병렬 1차 수체 반응계수를 구하고, 5개 관벽 감소 모델을 비교 평가하여 1차 관벽 감소계수 산출하고 적용했을 때 잔류염소 현장 측정값과 관망 수질모델링에 의한 예측간의 평균절대오차 및 평균제곱근오차가 각각 0.03, 0.037 mg/L로 가장 작았다. 또한 병실험에 의한 THMs생성량을 비선형 회귀분석으로 1차 생성계수를 구하고 현장 측정값과 비교하였다. 그 결과, 9월의 현장 측정값과 예측값의 결정계수 $R^2$는 0.98, 11월에는 0.82로 예측이 가능하였다.

소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계 (Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR)

  • 김낙현;이사용;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

A Control Volume Scheme for Three-Dimensional Transport: Buffer and Matrix Effects on a Decay Chain Transport in the Repository

  • Lee, Y.M.;Y.S. Hwang;Kim, S.G.;C.H. Kang
    • Nuclear Engineering and Technology
    • /
    • 제34권3호
    • /
    • pp.218-231
    • /
    • 2002
  • Using a three-dimensional numerical code, B3R developed for nuclide transport of an arbitrary length of decay chain in the buffer between the canister and adjacent rock in a high- level radioactive waste repository by adopting a finite difference method utilizing the control- volume scheme, some illustrative calculations have been done. A linear sorption isotherm, nuclide transport due to diffusion in the buffer and the rock matrix, and advection and dispersion along thin rigid parallel fractures existing in a saturated porous rock matrix as well as diffusion through the fracture wall into the matrix is assumed. In such kind of repository, buffer and rock matrix are known to be important physico-chemical harriers in nuclide retardation. To show effects of buffer and rock matrix on nuclide transport in HLW repository and also to demonstrate usefulness of B3R, several cases of breakthrough curves as well as three- dimensional plots of concentration isopleths associated with these two barriers are introduced for a typical case of decay chain of $^{234}$ Ulongrightarrow$^{230}$ Thlongrightarrow$^{226}$ Ra, which is the most important chain as far as the human environment is concerned.

미동정 부후균에 의한 소나무재의 Lignin 분해와 주사전자현미경(SEM)을 이용한 관찰 (Lignin Degradation of Pine Wood by Unidentified Decay Fungi and Observation by Scanning Electron Microscope)

  • 박헌;민경희
    • Journal of the Korean Wood Science and Technology
    • /
    • 제31권4호
    • /
    • pp.71-80
    • /
    • 2003
  • 목재의 주성분 중 가장 분해가 어려운 리그닌을 분해하는 균주를 선발하기 위해 산림지역에서 채취한 부후목과 자실체로부터 균을 분리하였다. 리그닌 분해능은 활엽수보다 미생물 분해가 어렵다고 알려진 침엽수인 소나무재에 미생물을 처리하여 Klason 리그닌 정량을 통해 조사하였다. 또한 선발균에 의한 소나무재의 분해과정과 부후정도를 주사전자현미경(Scanning Electron Microscope ; SEM)을 이용해 조사하였다. 선발 균주 중 CJ-6에서 소나무 리그닌의 분해율이 49.48%로 가장 높았으며, 이것은 리그닌 분해 우수 균주로 알려진 Trametes versicolor의 40.58%와 비교해 보았을 때 리그닌 분해력이 더 우수하였다. 균주들 중 리그닌 분해력이 좋게 나타난 2개의 균주를 대상으로 부후에 의한 목재조직의 변화를 관찰하였는데 두 균주의 부후형이 비슷한 경향을 나타내었다. 부후 20일 경과에서는 균사의 침입은 있었으나 아직 목재는 건전한 상태를 유지하고 있었으며, 60일 간의 부후에서는 부후가 어느 정도 진행되어 가도관 벽과 방사조직의 세포벽의 일부가 분해되어 있음을 알 수 있었다. 100일간 부후가 진행된 경우에는 부후가 상당히 진행되어 가도관 세포벽 안쪽이 분해가 많이 진행되어 있었으며, 방사조직의 세포벽이 많이 분해되어 있어 세포간의 구별이 어려웠다.

충돌제트로 인한 회전원판 위의 벽제트유동에 관한 실험적 연구 (Experimental Study on the Wall Jet Flow Induced by Impinging Circular Jet on Arotating Disk)

  • 강형석;유정열
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3386-3394
    • /
    • 1994
  • An experimental study has been performed on the flow over a rotating disk, where the diameter of the disk is 500 mm and the maximum vertical deviation of the upper surface is $50 \mu{m}$ for the whole range of the angular velocity up to 3400 rpm. The flow visualization experiment for the wall jet flow induced by impinging circular jet is carried out using schlieren system and measurements are made by 3-hole and 5-hole pitot tubes. Schlieren photographs show that as the rotating speed increases the wall jet flow becomes more stable and the size of the largest eddies becomes smaller. Measurements for impinging jet flow on the stationary disk verify the accuracy of the present experiment, and those for free rotating disk flow display the existence of transition region from laminar to turbulent flows. Measurements for impinging jet flow on the rotating disk exhibit the interaction between the wall jet and the viscous pumping effect, which explains the decay in size of turbulent eddies illustrated by the schlieren photographs.

Hydrodynamic coupling distance between a falling sphere and downstream wall

  • Lin, Cheng-Chuan;Huang, Hung-Tien;Yang, Fu-Ling
    • Coupled systems mechanics
    • /
    • 제7권4호
    • /
    • pp.407-420
    • /
    • 2018
  • In solid-liquid two phase flow, the knowledge of how descending solid particles affected by the presence of downstream wall is important. This work studies at what interstitial distance the velocity of a vertically descending sphere is affected by a downstream wall as a consequence of wall-modified hydrodynamic forces through a validated dynamic model. This interstitial distance-the hydrodynamic coupling distance ${\delta}_c-is$ found to decay monotonically with the approach Stokes number St which compares the particle inertia to viscous drag characterized by the quasi-steady Stokes' drag. The scaling relation ${\delta}_c-St-1$ decays monotonically as literature below the value of St equal to 10. However, the faster diminishing rate is found above the threshold value from St=10-40. Furthermore, an empirical relation of ${\delta}_c-St$ shows dependence on the drop height which clearly indicates the non-negligible effect of unsteady hydrodynamic force components, namely the added mass force and the history force. Finally, we attempt a fitting relation which embedded the particle acceleration effect in the dependence of fitting constants on the diameter-scaled drop height.

상수관망내 잔류염소농도 분포 예측 (Prediction of Chlorine Residual in Water Distribution System)

  • 주대성;박노석;박희경;오정우
    • 상하수도학회지
    • /
    • 제12권3호
    • /
    • pp.118-124
    • /
    • 1998
  • To use chlorine residual as an surrogate parameter of the water quality change during the transportation in the water distribution system(WDS), the correct prediction model of chlorine residual must be established in advance. This paper shows the procedure and the result of applying the water quality model to the field WDS. To begin with, hydraulic model was calibrated and verified using fluoride as an tracer. And chlorine residual was predicted through simulation of water quality model. This predicted value was compared with the observed value. With adjusting the bulk decay coefficient(kb) and the wall decay coefficient(kw) according to the pipewall environment, the predicted chlorine residual can represent the observed value relatively well.

  • PDF

2次元 亂流 Stepped Wall Jet 의 流動特性 (Flow Characteristics of Two-Dimensional Turbulent Stepped Wall Jet)

  • 부정숙;김경천;박진호;강창수
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.732-742
    • /
    • 1985
  • 본 논문에서는 이 2차원 재부착분류(본문에서는 stepped wall jet라 명명함) 유동장을 재부착상류 부분, 재부착점 근방, 재부착 이후의 재발전 벽면분류 지역의 세 영역으로 구분하여 재부착 길이, 평균속도, 벽면정압을 측정하고 on-line에 의한 디지 틀 데이터 처리기법을 이용하여 난류강도, 레이놀즈 전단응력, 속도의 3승적(triple velocity product), integral length scale, Taylor's microscale 등을 실험적으로 구 하여 재부착 상류 부분에서는 자유분류와 비교하고, 재부착 이후에서는 2차원 벽면분 류와 비교하기로 한다.그리하여 초기 교란을 받는 분류가 벽면에 재부착하여 2차원 벽면분류로 재발전되어 가는 과정에 있어서의 평균 유동장과 급격한 변화를 갖는 난류 특성을 상세히 조사하여, 보다 일반적으로 적용될 수 있는 난류모델을 개발함에 있어 서 실험적인 자료를 제공하고자 한다. Fig. 1은 본 실험의 유동장에 대한 개약도를 보여주고 있다.

주택의 실내공기질 개선 평가 방법 (Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence)

  • 양원호;손부순;임성국
    • 한국환경보건학회지
    • /
    • 제33권4호
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.