• 제목/요약/키워드: wall decay

검색결과 96건 처리시간 0.019초

제한공간내 펄스가열에 기인한 열음향파의 전달특성에 관한 수치적 연구 (A Numerical Study on the Transmission of Thermo-Acoustic Wave Induced by Step Pulsed Heating in an Enclosure)

  • 황인주;김윤제
    • 설비공학논문집
    • /
    • 제14권11호
    • /
    • pp.914-922
    • /
    • 2002
  • Thermo-acoustic waves can be thermally generated in a compressible flow field by rapid heating and cooling, and chemical reaction near the boundary walls. This mechanism is very important in the space environment in which natural convection does not exist. Also this may be a significant factor for heat transfer when the fluids are close to the thermodynamic critical point. In this study, the generation and transmission characteristics of thermo-acoustic waves in an air-filled confined domain with two-step pulsed heating are studied numerically. The governing equations are discretized using control volume method, and are solved using PISO algorithm and second-order upwind scheme. For the purpose of stable solution, time step was set to the order of $1\times10_-9s,\;and\;grids\;are\;50\times2000$. Results show that temperature and pressure distributions of fluid near the boundary wall subjected to a rapid heating are increased abruptly, and the induced thermo-acoustic wave propagates through the fluid until it decays due to viscous and heat dissipation. Pressure waves have sharp front shape and decay with a long tail in the case of step heating, but these waves have sharp pin shape in the case of pulsed heating.

수동적 감마선분석에 의한 핵물질 농축도 측정 (Enrichment Measurement of Nuclear Materials by Passive Gamma-ray Analysis)

  • Hong, Jong-Sook;Cha, Hong-Ryul;Park, Hyoung-Nae;Lee, Byung-Doo;Park, Ho-Joon
    • Nuclear Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.233-240
    • /
    • 1991
  • 수동적 감마선분석에 의해 U-235의 농축도를 비파괴적으로 측정하였다. 측정차상이 되는 선원은 U-235의 알파붕괴시 방출되는 185.7 keV 감마선이다. 농축도 측정에 영향을 미치는 인자, 즉 시료구성, 시료용기의 두께변화에 따른 감쇠효과, 감마선의 집속 및 검출효율 등을 평가하였다. 최적계측시스템하에서 측정된 상대오차는 95%신뢰구간에서 Tag값과 비교했을 때 감손 UF$_{6}$ 실린더에 대해서는 ~8%, 감손 및 천연 $UO_2$분말에 대해서는 ~8%, ~1%로 각각 나타났다.

  • PDF

$AgInS_2$ 단결정 박막 성장과 광센서 특성 (Growth and Photosensor Properties for $AgInS_2$ Single Crystal Thin Film)

  • 홍광준;백승남
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.134-135
    • /
    • 2006
  • $AgInS_2$ single crystal thin filmsl was deposited on throughly etched semi-insulator GaAs(100) substrate by the Hot Wall Epitaxy (HWE) system. The source and substrate temperature were $680^{\circ}C$ and $410^{\circ}C$ respectively, and the thickness of the single crystal thin films is $6{\mu}m$. From the photocurrent spectrum by illumination of perpendicular light on the c-axis of the $AgInS_2$ single crystal thin film, we have found that the values of spin orbit coupling ${\Delta}So$ and the crystal field splitting ${\Delta}Cr$ were 0.0098 eV and 0.15 eV at 10 K, respectively. In order to explore the applicability as a photoconductive cell, we measured the sensitivity ($\gamma$), the ratio of photocurrent to darkcurrent (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time. The result indicated that the samples annealed in S vapour the photoconductive characteristics are best. Therefore we obtained the sensitivity of 0.98, the value of pc/dc of $1.02{\times}10^6$, the MAPD of 312 mW, and the rise and decay time of 10.4ms and 10.8ms respectively.

  • PDF

통합보존식 해석과 HCIB 법을 이용한 슬로싱 탱크 내부 갇힌 공기에 의한 압력 진동 모사 (Simulation of a Pulsating Air Pocket in a Sloshing Tank Using Unified Conservation Laws and HCIB Method)

  • 신상묵
    • 대한조선학회논문집
    • /
    • 제58권5호
    • /
    • pp.271-280
    • /
    • 2021
  • The code developed using a pressure-based method for unified conservation laws of incompressible/compressible fluids is expanded to handle moving or deforming body boundaries using the hybrid Cartesian/immersed boundary method. An instantaneous pressure field is calculated from a pressure Poisson equation for the whole fluid domain, including the compressible gas region. The polytropic gas is assumed for the compressible fluid so that the energy equation is decoupled. Immersed boundary nodes are identified based on edges crossing body boundaries. The velocity vector is reconstructed at the immersed boundary node using an interpolation along the assigned local normal line. The developed code is validated by comparing the time histories of pressure and wave elevation for sloshing in a rectangular and a membrane-type tank. The validated code is applied to simulate air cushion effects in a rectangular tank under sway motion. Time variations of pressure fields are analyzed in detail as the air pocket pulsates. It is shown that the contraction and expansion of the air pocket dominate the pressure loads on the wall of the tank. The present results are in good agreement with other experimental and computational results for the amplitude and the decay of the pressure oscillations measured at the pressure gauges.

Hot Wall Epitaxy(HWE)법에 의한 MnAl2S4 단결정 박막 성장과 광전도 특성 (Growth and optical conductivity properties for MnAl2S4 single crystal thin film by hot wall epitaxy method)

  • 유상하;이기정;홍광준;문종대
    • 한국결정성장학회지
    • /
    • 제24권6호
    • /
    • pp.229-236
    • /
    • 2014
  • 수평 전기로에서 $MnAl_2S_4$ 다결정을 합성하여 HWE(Hot Wall Epitaxy)방법으로 $MnAl_2S_4$ 단결정 박막을 반절연성 GaAs(100)기판에 성장시켰다. $MnAl_2S_4$ 단결정 박막의 성장 조건은 증발원의 온도 $630^{\circ}C$, 기판의 온도 $410^{\circ}C$였고 성장 속도는 $0.5{\mu}m/hr$였다. 이때 $MnAl_2S_4$ 단결정 박막의 결정성의 조사에서 이중결정 X-선 요동곡선(DCRC)의 반폭치(FWHM)도 132 arcsec로 가장 작아 최적 성장 조건임을 알 수 있었다. $MnAl_2S_4$/SI(Semi-Insulated) GaAs(100) 단결정 박막의 광흡수를 293 K에서 10 K까지 측정하였다. 광흡수 스펙트럼으로부터 band gap $E_g(T)$는 Varshni 공식에 따라 계산한 결과 $E_g(T)=3.7920eV-(5.2729{\times}10^{-4}eV/K)T^2/(T+786K)$였다. $MnAl_2S_4$ 단결정 박막의 응용소자인 photocell로 사용할 수 있는 pc/dc 값이 가장 큰 광전도셀은 S 증기분위기에서 열처리한 셀로 $1.10{\times}10^7$이었으며, 광전도 셀의 감도(sensitivity)도 S 증기분위기에서 열처리한 셀이 0.93로 가장 좋았다. 또한 최대 허용소비전력(MAPD)값도 S 증기분위기에서 열처리한 셀이 316 mW로 가장 좋았으며, S 증기분위기에서 열처리한 셀의 응답시간은 오름시간 14.8 ms, 내림시간 12.1 ms로 가장 빠르게 나타나, $MnAl_2S_4$ 단결정 박막을 S 분위기에서 $290^{\circ}C$로 30분 열처리한 photocell이 상용화가 가능할 것으로 여겨진다.

기능성 소재가 코팅된 골판지상자의 감귤의 신선도 유지 효과 (Freshness Extension of Corrugated Fiberboard Box coated with Functional Materials)

  • 박형우;김동만;김윤호;이선아
    • 한국포장학회지
    • /
    • 제8권2호
    • /
    • pp.27-31
    • /
    • 2002
  • 제주산 감귤을 기존의 골판지와 이골판지에 특성이 다른 선도 유지기능성 소재 3종을 상자 내면에 코팅하여 여기에 감귤을 넣고 $25^{\circ}C$에 8일간 저장하면서 선도 유지효과를 조사하였다. 중량은 모든 포장구에서 2.6-3.7%가 감소하였고 산도와 당도는 포장구간에 차가 없었으며 비타민 C 함량은 대조구 보다 R-Box와 Y-Box가 10% 높게 유지되고 있었다. 부패율도 R-Box는 4%였으나 나머지 포장구는 8-11%의 감귤이 부패되었으며 외관도 R-Box가 가장 양호하였다.

  • PDF

A correlation between moisture and compressive strength of a damaged 15-year-old rammed soil house

  • Preciado, Adolfo;Santos, Juan Carlos;Ramirez-Gaytan, Alejandro;Ayala, Karla;Garcia, Jose de Jesus
    • Geomechanics and Engineering
    • /
    • 제23권3호
    • /
    • pp.227-244
    • /
    • 2020
  • Earthen structures have an excellent bioclimatic performance, but they are vulnerable against earthquakes. In order to investigate the edification process and costs, a full-scale rammed soil house was constructed in 2004. In 2016-2019, it was studied its seismic damage, durability and degradation process. During 2004-2016, the house presented a relatively good seismic performance (Mw=5.6-6.4). The damaged cover contributed in the fast deterioration of walls. In 2018 it was observed a partial collapse of one wall due to recent seismicity (Mw=5.6-6.1). The 15-year-old samples presented a reduced compressive strength (0.040 MPa) and a minimum moisture (1.38%). It is estimated that the existing house has approximately a remaining 20% of compressive strength with a degradation of about 5.4% (0.0109 MPa) per year (considering a time frame of 15 years) if compared to the new soil samples (0.2028 MPa, 3.52% of moisture). This correlation between moisture and compressive strength degradation was compared with the study of new soil samples at the same construction site and compared against the extracted samples from the 15-year-old house. At 7-14-days, the specimens presented a similar compressive strength as the degraded ones, but different moisture. Conversely, the 60-days specimens shown almost five times more strength as the existing samples for a similar moisture. It was observed in new rammed soil that the lower the water content, the higher the compressive/shear strength.

자외선램프을 이용한 유수처리장치 설계 시뮬레이션 (Simulation Method for the Flowing Water Purification with UV Lamp)

  • 정병호;이강연
    • 조명전기설비학회논문지
    • /
    • 제23권9호
    • /
    • pp.17-23
    • /
    • 2009
  • 자외선 살균기술을 바탕으로 한 수처리 분야에 대한 관심이 최근 증가하고 있다. 수처리분야에서 살균처리방식의 효율은 유체 살균챔버나 살균강도 그리고 미생물의 불활성역학에 따라 수처리 성능이 결정된다. 광산화법에 이용되는 빛은 주로 자외선이 이용되며 매우 깨끗하고 높은 에너지를 가지고 있어 화학살균방법에 비해 잔류물이 없고 높은 안정성으로 최근 관심이 높아지고 있다. 그러나 자외선살균방식은 조사시간과 조사량에 직접적인 영향을 받아 이를 위한 최적의 설계가 이루어져야 한다. 본 연구에서는 유수살균장치의 챔버 내의 자외선 램프와 유수에 대한 3D-CFD discrete ordinates model 모델을 제시하고 이를 시뮬레이션을 통해 설계방식의 최적화 여부를 검증하고 향후 유수형 자외선살균방식의 시뮬레이션방법을 제안하고자 한다.

Sensitivity Analyses for Maximum Heat Removal from Debris in the Lower Head

  • Kim, Yong-Hoon;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.395-409
    • /
    • 2000
  • Parametric studies were performed to assess the sensitivity in determining the maximum in-vessel heat removal capability from the core material relocated into the lower plenum of the reactor pressure vessel (RPV)during a core melt accident. A fraction of the sensible heat can be removed during the molten jet delivery from the core to the lower plenum, while the remaining sensible heat and the decay heat can be transported by rather complex mechanisms of the counter-current flow limitation (CCFL) and the critical heat flux (CHF)through the irregular, hemispherical gap that may be formed between the freezing oxidic debris and the overheated metallic RPV wall. It is shown that under the pressurized condition of 10MPa with the sensible heat loss being 50% for the reactors considered in this study, i.e. TMI-2, KORI-2 like, YGN-3&4 like and KNGR like reactors, the heat removal through the gap cooling mechanism was capable of ensuring the RPV integrity as much as 30% to 40% of the total core mass was relocated to the lower plenum. The sensitivity analysis indicated that the cooling rate of debris coupled with the sensible heat loss was a significant factor The newly proposed heat removal capability map (HRCM) clearly displays the critical factors in estimating the maximum heat removal from the debris in the lower plenum. This map can be used as a first-principle engineering tool to assess the RPV thermal integrity during a core melt accident. The predictive model also provided ith a reasonable explanation for the non-failure of the test vessel in the LAVA experiments performed at the Korea Atomic Energy Research Institute (KAERI), which apparently indicated a cooling effect of water ingression through the debris-to-vessel gap and the intra-debris pores and crevices.

  • PDF

Comparison of retention characteristics of ferroelectric capacitors with $Pb(Zr, Ti)O_3$ films deposited by various methods for high-density non-volatile memory.

  • Sangmin Shin;Mirko Hofmann;Lee, Yong-Kyun;Koo, June-Mo;Cho, Choong-Rae;Lee, June-Key;Park, Youngsoo;Lee, Kyu-Mann;Song, Yoon-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권3호
    • /
    • pp.132-138
    • /
    • 2003
  • We investigated the polarization retention characteristics of ferroelectric capacitors with $Pb(Zr,Ti)O_3$ (PZT) thin films which were fabricated by different deposition methods. In thermally-accelerated retention tests, PZT films which were prepared by a chemical solution deposition (CSD) method showed rapid decay of retained polarization charges as the thickness of the films decreased down to 100 nm, while the films which were grown by metal organic chemical vapor deposition (MOCVD) retained relatively large non-volatile charges at the corresponding thickness. We concluded that in the CSD-grown films, the thicker interfacial passive layer compared with the MOCVD-grown films had an unfavorable effect on retention behavior. We observed the existence of such interfacial layers by extrapolation of the total capacitance with thickness of the films and the capacitance of these layers was larger in MOCVD-grown films than in CSD-grown films. Due to incomplete compensation of surface polarization charges by the free charges in the metal electrodes, the interfacial field activated the space charges inside the interfacial layers and deposited them at the boundary between the ferroelectric layer and the interfacial layer. Such space charges built up an internal field inside the films, which interfered with domain wall motion, so that retention property at last became degraded. We observed less imprint which was a result of less internal field in MOCVD-grown films while large imprint was observed in CSD-grown films.