• Title/Summary/Keyword: w-distance

Search Result 909, Processing Time 0.029 seconds

Effects on the Oxidation Rate with Silicon Orientation and Its Surface Morphology (실리콘배향에 따른 산화 속도 영향과 표면 Morphology)

  • Jeon, Bup-Ju;Oh, In-Hwan;Um, Tae-Hoon;Jung, Il-Hyun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.3
    • /
    • pp.395-402
    • /
    • 1997
  • The $SiO_2$ films were prepared by ECR(electron cyclotron resonance) plasma diffusion method, Deal-Grove model and Wolters-Zegers-van Duynhoven model were used to estimate the oxidation rate which was correlated with surface morphology for different orientation of Si(100) and Si(111). It was seen the $SiO_2$ thickness increased linearly with initial oxidation time. But oxidation rate slightly decrease with oxidation time. It was also shown that the oxidation process was controlled by the diffusion of the reactive species through the oxide layer rather than by the reaction rate at the oxide interface. The similar time dependency has been observed for thermal and plasma oxidation of silicon. From D-G model and W-Z model, the oxidation rate of Si(111) was 1.13 times greater than Si(100) because Si(111) had higher diffusion and reaction rate, these models more closely fits the experimental data. The $SiO_2$ surface roughness was found to be uniform at experimental conditions without etching although oxidation rate was increased, and to be nonuniform due to etching at experimental condition with higher microwave power and closer substrate distance.

  • PDF

The Study of Hydrothermal Vent and Ocean Crustal Structure of Northeastern Lau Basin Using Deep-tow and Surface-tow Magnetic Data (심해 및 표층 지자기 자료를 이용한 라우분지 북동부의 열수 분출구 및 해저 지각 구조 연구)

  • Kwak, Joon-Young;Won, Joong-Sun;Park, Chan-Hong;Kim, Chang-Hwan;Ko, Young-Tak
    • Economic and Environmental Geology
    • /
    • v.41 no.1
    • /
    • pp.81-92
    • /
    • 2008
  • Fonualei Rift and Spreading Center(FRSC) and Mangatolu Triple function(MTJ) caldera are located in northeastern part of Lau basin which is the active back-arc basin. Deep-tow and surface-tow magnetic surveys are carried out in FRSC. In deep-tow magnetic survey, to compensate for influence of uneven distance between bathymetry and sensor height, magnetic anomaly is continued upward to a level plane by using the Guspi method. We calculate crustal magnetization using Parker and Huestis's inversion algorithm, and try to find the hydrothermal vent and understand the structure of ocean floor crust. The result of deep-tow magnetic survey at FRSC showed that Central Anomaly Magnetization High(CAMH) recorded the max value of 4.5 A/m which is associated with active ridge. The direction of SSW-NNE corresponds with the direction of the principal spreading ridge in Lau basin. The low crustal magnetizaton$(174^{\circ}35.1'W,\;16^{\circ}38.4'S)$ of -4.0 A/m is supposed to correlate with submarine hydrothermal vent. Surface-tow magnetic data were collected in MTJ caldera$(174^{\circ}00'W,\;15^{\circ}20'S)$. The prevailing SSW-NNE direction of collapsing walls and the presence of CAMH at the center of caldera strongly indicate the existence of active spreading ridge in ancient times.

Linear Source for Evaporating Large Area CIGS Absorber Layer (대면적 CIGS 광흡수층 증착을 위한 선형증발원 개발)

  • Seo, J.H.;Jung, S.W.;Lee, W.S.;Choi, Y.S.;Choi, M.W.;Choi, J.C.;Jeong, K.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • In this paper, to develop linear source for evaporating $600{\times}1,200mm$ size of large area CIGS absorber layer, we simulated linear thermal source and obtained ${\pm}5%$ thickness uniformity with various nozzle sizes and regular nozzle distance. Flux density was confirmed linear source length. Using this linear source, we tested thickness uniformity of Copper, Indium single layer which was obtained Cu ${\pm}5%$ and In ${\pm}5%$ thickness uniformity. And then CIGS absorber layers were evaporated with In-line single-stage co-evaporation. Large area CIGS absorber layers were confirmed composition uniformity of $$Cu{\leq_-}5%$$, $$In{\leq_-}7%$$, $$Ga{\leq_-}4%$$, $$Se{\leq_-}3%$$ with 600 mm width by XRF. Uniform shape of CIGS absorber layers was confirmed by SEM. XRD showed peaks which indicate chalcopyrite structure of CIGS absorber layers. Thus, developed linear source is suitable for evaporating CIGS absorber layer.

Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays (Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율)

  • Kim, Wuon-Shik;Hah, Suck-Ho;Hwang, Sun-Tae;Oh, Jang-Jin;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Central axis percentage depth-doses, P(%), were measured at the points from the 2.5cm depth of reference point to 20 cm depth with 2.5 cm interval. Distance from the X-ray target to the water phantom($30{\times}30{\times}30cm^3$) surface was 1 m, and at this point three different beam sizes of $5cm{\phi},\;10cm{\phi},\;and\;15cm{\phi}$ were used. While the X-ray tube voltage varied from 150 to 250 kV, the tube current remained constant at 5 mA. Absorbed dose rate in water, $\dot{D}_w$, was determined using the air kerma calibration factor, $N_k$, which was derived from the exposure calibration factor, $N_x$, of the NE 2571 ion chamber. The reference exposure rate, $\dot{X}_c$, was measured using the Exradin A-2 ion chamber calibrated at ETL, Japan. The half value layers of the X-rays determined to meet ETL calibration qualities. The absorbed dose rates determined at the calibration point were compared to the values obtained from Burlin's general cavity theory, and the percentage depth-dose values determined from $N_k$ showed a good agreement with the values of the published depth dose data(BJR Suppl. 17).

  • PDF

Development Plan of R.O.K. Naval forces to prepare Tasks in the Arctic Ocean: Based on Operational Environment(SWOT) Analysis (한국 해군의 북극해 진출과 발전방안에 대한 고찰: 작전환경(SWOT) 분석을 중심으로)

  • Ji, Young
    • Maritime Security
    • /
    • v.1 no.1
    • /
    • pp.311-343
    • /
    • 2020
  • Because of the global warming, the Arctic Ocean is expected to be ice-free by the year 2035. When the Arctic Ocean will be opened, a number of national interests will become more salient as experiencing a shortened sailing distance and decreasing navigation expense, possibility of natural resources transport by sea from Arctic Circle, and indirect-profit making by building a herb port in Asia. To secure the national interests and support the free activities of people in this region, R.O.K government is trying to make advanced policies. In order to carry out the naval tasks in the Arctic Ocean, using the operational characteristics(mobility, flexibility, sustainability, presence of capabilities, projection) is necessary. To this end, ROK Navy should analyze the operational environment (O.E.) by its capability(weakness and strength), opportunity, and threat. R.O.K. Navy should make an effort over the following issues to implement the tasks in the Arctic Ocean: first, Navy needs to map out her own plan (Roadmap) under the direction of government policies and makes crews participate in the education·training programs in home and abroad for future polar experts. Third, to develop the forces and materials for the tasks in cold, far operations area, Navy should use domestic well-experienced shipbuilding skills and techniques of the fourth industrial revolution. Next, improving the combined operations capabilities and military trust with other countries in the Arctic region to cover the large area with lack of forces' number and to resolve the ports of call issues. Lastly, preparation in advance to execute a variety of missions against military and non-traditional threats such as epidemics, HA/DR, SOLAS, in the future operation area is required.

  • PDF

A Study on Facilities Damage Characteristics Caused by Forest Fire in Goseong-Gun (고성산불로 인한 시설물피해특성 연구)

  • Yeom, Chanho;Lee, Si-young;Park, Houngsek;Kwon, Chungeun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.469-478
    • /
    • 2019
  • Purpose: In this studies we examine the facilities damage characteristics caused by forest fire. Therefore, we surveyed damaged facilities from forest fire which was occurred on Goseong-Gun on march 28 in 2019.(damaged areas was 40ha) The types of facilities uses were house, public facility, warehouse and so on. 17 facilities were destroyed. The purpose of this study was to for establishing a disaster safety village in rural areas where damage from a similar type of disaster occurs repeatedly by conducting the consciousness survey targeting at experts and disaster safety officials in a local government. Method: We surveyed meteorological factors(temperature, wind speed, wind direction, humidity) per a minute for analyzing weather condition on Goseong-Gun when forest fire was occurred, spread and extinguished. And we surveyed forest fire risk factors(a slope degree, a slope direction, a geographical feature, a distance between forest and facility, main species, the existence of crown fire ignition, the direction of facility, the main material of building) around 10 damaged facilities. Finally, we analyzed damage pattern of facilities using meteorological factor and forest fire reisk fator Result: The weather condition of Kanseonng AWS (No.517) was high temperature, arid and strong wind, when the forest fire was occurred and spread. An average wind speed was 4.1m/s and the maximum wind speed was 11.6m/s. The main direction of wind was W(225~315°). Damaged facilities were located on the steep slope area and on the mountaintop. The forest density around facilities was high and main species was korean red pine. The crown fire was occurred in the forest around damaged facilities. The average distance was 13.5m from forest to facilities. When the main matarial of building was made by fire resistance materials (for example, rainforced concrete), the damage was slightly. on the other hand, when by flammable material (for example, a Sandwich Panel), the facilities were totally destroyed Conclusion: The results of this research which were the thinning around house, making a safety distance, the improvement of main material of building and etc, will be helpful for establishing a counter measure for a forest fire prevention of facilities in wild land urban interface

Seasonal Development and Control of Parthenolecanium corni in Blueberry Shrubs (블루베리에 발생하는 말채나무공깍지벌레의 계절적 발육과 방제)

  • Lee, Seok-Min;Chung, Bu-Keun;Kang, Dong-Wan;Park, Kyung-Mi;Han, In-Young;Kwon, Jin-Hyeuk;Lee, Heung-Su
    • Korean journal of applied entomology
    • /
    • v.60 no.4
    • /
    • pp.403-415
    • /
    • 2021
  • Seasonal development of Parthenolecanium corni was observed from 4 Jun. 2019 (nymph) - 25 Jun. 2020 (1st Gen. nymph) in blueberry shrub in Sacheon city, Gyeongsangnam-do. To investigate their development, more than 5 twigs sprouted in 2018 were taken from the farm nearly weekly basis. The development of each scale were examined under the stereomicroscope and chemical control was conducted in the blueberry shrub with available three insecticides. The results on the development period and Centigrade Degree-Days accumulation (DDC) obtained are as follows: egg-laying period (peak): 12 -26 May 2020 (24 May)(DDC, 110.0-188.5 (173.6)); egg-hatching period (peak): 9 - 23 June 2020 (19 June)(DDC, 325.2-480.8(435.6); egg period: 26 days; nymph movement from overwintered adult to new leaves 16-25 June 2020 (DDC, 410,5-500.4); nymph movement from leaf to twig (peak) to become adult: 4-18 Feb. 2020 (8 Feb.). Eggs no. /adult (range): 956.8 ± 73.4 (13 - 3497). Size (mm) of egg, 0.29 ± 0.020(L), 0.15 ± 0.013(W); of egg-hatched nymph, 0.35 ± 0.018(L), 0.18 ± 0.007(W), 0.09 ± 0.007(eye distance); and of adult, 4.30 ± 0.893(L), 2.64 ± 0.520(W). The egg-hatched nymphs from the overwintered adult moved to the backside leaf of new shoot in which they found about 95% until leaf is falling by early February in next year. They overwintered as 2nd instar and occurred univoltine. For the control of the 1st instar crawler, three insecticides treated on 16 and 30 July at the registered dose for Ceroplastes japonicus. Acetamiprid 8WP showed 96.9% mortality at 21 days after 1st treatment.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

Population density of potato virus vectors In the Kwanghwal Area, Kimje-gun, Cholla-Pukto, on the western coast (씨감자 생산을 위한 매개 진딧물 조사 - 전북 김제군 광활면의 진딧물 분포상 -)

  • Paik Woon Hah
    • Korean journal of applied entomology
    • /
    • v.7
    • /
    • pp.5-13
    • /
    • 1969
  • Present system of seed potato production in Korea has several weak points and consequently has difficulties in covering annual shortage of 60,000 tons of seed potatoes. The author has an opinion that this so called 'High land system' of seed potato production adopted by the Government should be replaced by the 'Coastal area system' which is proposed by the author and has many advantages over present 'High land system'(2). In coastal areas where enormous acreage of rice paddies are spread, mostly around the villages. the primary host plants of the vectors are found. Therefore, the only source of aphid vectors are limited to the villages. The farmer's houses scattered more sparsely also have minor importance. In the previous paper(2), the author reported that the aphid vector populations were lower in the coastalareas than at Taegwanryong where the Alpine Experiment Station for the production. of seed potatoes is located. However, the number to vectors at Okku showed rather high density, where the trap was placed at the distance of 200 m from a village where peach and Hibiscus trees, the primary hosts of Myzus pesrsicae and Aphis gossypii were grown. To clarify the flight distance from the source of the aphid vectors, a trial was carried out in the Kwanghwal area, Kimje-gun, Cholla-pukto. on the western coast. 13 traps were placed at four directions and the distances between the traps were 250 m. (Fig. I) The traps 'Were operated from June 21 to October 31. The results are shown in Table 1. A total of some 70 species of aphids were found, including 5 speceis of potato virus vectors. The vectors are as follows: I. Myzus persicae (Sulzer) 2. Aphis gossypii Glover 3. Aulacorthum solani (Kaltenbach) 4. Lipaphis erysimi (Kaltenbach) 5. Macrosiphoniella sanborni (Gillette) Out of a total of 12,797 aphids, 5,187$(48\%)$ vectors were found. The trap catches at the 13 locations are shown in Fig. 2 and the numbers of the vectors at each location for each vector, except Macro-siphoniella sanborni. of which only a single individual was caught, are shown in Fig. 3-6. Number of vectors at C (3,279) (Centre of the village) is considerably higher than that at Suwon (763); however, EI. SI. WI and NI. where the distanecs from Care 250 m, showed lower numbers of vectors than that at Taegwanryong (347). The number of vectors at NI was rather than at the other 3 locations at the distance of 250m from the village. This was because C was in the southern part of the village. Consequently NI was much closer to the village than the other 3 locations of the same distance from C. Numbers of catches of the most important vector. Myzus persicae, are shown in Fig.3. The distribution pattern is typical except $S-2\;and\;W_3$, where several farmer's houses were found. If only the rice paddies were found in these locations. the numbers of the vectors would be small as the distances increase. Numbers of catches of the other 3 vectors are shown in Fig. 4-6. From these results. the author has drawn the following conclusions: 1. The aphid vector sources at the rice paddy belt in the western coast are the villages. 2. The vector densities at the locations where the distances are 250 m from the centre of the village are lower than that at Taegwanryong. 3. The vector densities become gradually lower as the distances from the centre of village increase. However. depending on the host plant situation at each location, the vector densities are variable. These minor sources of aphid vectors may be eliminated so that seed potatoes can be grown. 4. Thus. under the direction of specialists, fields suitable for seed potato production can be found in the coastal areas.

  • PDF

Evaluation of Groundwater Quality Characteristics around Uncontrolled Closed Valley Landfill (사용종료 비위생매립지 주변 지하수의 수질변화 특성)

  • Park, Joung-Ku;Kim, Tae-Dong;Choi, Dong Hyuk;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.3
    • /
    • pp.75-80
    • /
    • 2007
  • This study evaluated groundwater quality around an uncontrolled landfill in W sity, Korea, which was monitored for about two years (2005-2006). Parameters of concern include redox-sensitive indicators such as pH, DO, EC, ORP, DOC (dissolved organic carbon), NH3, NO3 and SO4. About 10 years have elapsed after closing dumping of municipal wastes in the landfill. Leachates showed widely varying concentrations in COD(136${\sim}$263 mg/L), T-N(121${\sim}$186 mg/L), and NH3-N(14${\sim}$369 mg/L). Groundwater at the immediate downgradient of the landfill showed weakly acidic pH condition but very high levels of EC (3,000-4,000 ${\mu}S/cm$), which indicated that the groundwater was largely affected by the landfill leachate. Cl, a conservative ion, showed over 200 mg/L at the landfill border, but a gradually decreasing level with distance from the landfill, representing dispersion and dilution (natural attenuation) due to mixing with surrounding groundwater and replenished rainwater. Redox potential showed negative value at the landfill border but it increased up to 350 mV at downgradient wells, which indicated conversion of redox condition from reducing oxic ones. Ammonia, was largely enriched at most of the monitoring wells and its level greatly exceeded drinking water standard. In summary, all the parameters evidenced occurrence of natural attenuation with distance and with time but further monitoring is still required.