• Title/Summary/Keyword: w-distance

Search Result 907, Processing Time 0.028 seconds

Implementation of Software for the Brake Test in the Vehicle using the LabView (LabView를 이용한 자동차 제동시험 S/W 구현)

  • Kang, Jun-Hwan;Kim, Sun-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.752-757
    • /
    • 2008
  • In this paper, studied Measuring Equipment for Brake Test provided to test a braking distance and stability on various conditions while at stop/drive. It ensures an objectivity, repeatability and reproducibility for a brake test, which may be applied to various types of braking distance and stability tests anywhere in the world. With Measuring S/W for Brake Test mounted on the vehicle while at stop/drive, braking distance and stability were examined under conditions specified of NCAP and vehicle manufactures A and B's own test, which was available under all conditions and even harder ones to confirm this measuring S/W for brake test be applicable for any changed conditions for the future.

Estimation of Earthquake Magnitude-Distance Combination Corresponding to Design Spectrum in Korean Building Code 2016 (우리나라 건축물 설계 스펙트럼에 상응하는 지진규모와 진앙거리의 추정)

  • Jeong, Gi Hyun;Lee, Han Seon;Hwang, Kyung Ran
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • In this study, to estimate the combination of earthquake magnitude ($M_w$) and distance (R) corresponding to the design spectrum defined in Korean Building Code (KBC) 2016, the response spectra predicted from the attenuation relationships with the variation of $M_w$ (5.0~7.0) and R (10~30km) are compared with the design spectrum in KBC 2016. Four attenuation relationships, which were developed based on local site characteristics and seismological parameters in Southern Korea and Eastern North America (ENA), are used. As a result, the scenario ground motions represented by the combinations of $M_w$ and R corresponding to the design spectrum for Seoul defined in KBC 2016 are estimated as (1) when R =10 km, $M_w=6.2{\sim}6.7$; (2) when R = 15 km, $M_w=6.5{\sim}6.9$; and (3) when R = 20 km, $M_w=6.7{\sim}7.1$.

The Effects of Electrode Distance on the Formation of $(ZnS)_{1-x}(SiO_2)_x$ Protective Films in Phase Change Optical Disk by R.F. Sputtering Method (R.F. Sputtering 방법에 의한 상변화형 광디스크의 $(ZnS)_{1-x}(SiO_2)_x$ 보호막 형성에 미치는 전극거리의 영향)

  • Lee, Jun-Ho;Kim, Do-Hun
    • Korean Journal of Materials Research
    • /
    • v.9 no.12
    • /
    • pp.1245-1251
    • /
    • 1999
  • Phase-change optical disk very rapid recording, high densification of data, resulting in high feedback rate and good C/N(carrier to noise) ratio of a feedback signal. However, repetitive thermal energy may cause the deformation of a disk or the lowering of an eliminability and a cyclability of the recording. The lowering of the cyclability can be reduced by insertion of thin layer of ZnS-$SiO_2$ dielectric thin film in appropriate disk structure between the upper and lower part of the recording film. Using the Taguchi method, optimum conditions satisfying both the optimized quality characteristic values and the scattering values for film formation were found to be the target R.F. power of 200W, the substrate R.F. power of 20W, the Ar pressure of 6mTorr, and the electrode distance of 6cm. From the refractive index data, the existence of the strong interaction between the electrode distance and Ar pressure was confirmed, and so was the large effect of the electrode distance on transmittance. According to the analysis of TEM and XRD, the closer the electrode distance was, the finer was the grain size due to the high deposition rate. However, the closer electrode distance brought the negative effect on the morphology of the film and caused the reduction of transmittance. AFM and SEM analyses showed that the closer the electrode distance was, the worse was the morphology due to the high rate of the deposition. Under optimum condition, the deposited thin film showed a good morphology and dense microstructure with less defects.

  • PDF

GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy (GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정)

  • Lee, Byung Koo;Lim, Hyun Soo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

Study on Thermal Analysis for Optimization LED Driver ICs

  • Chung, Hun-Suk
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.59-61
    • /
    • 2017
  • This research was analyzed thermal characteristics that was appointed disadvantage when smart LED driver ICs was packaged and we applied extracted thermal characteristics for optimal layout design. We confirmed reliability of smart LED driver ICs package without additional heat sink. If the package is not heat sink, we are possible to minimize package. For extracting thermal loss due to overshoot current, we increased driver current by two and three times. As a result of experiment, we obtained 22 mW and 49.5 mW thermal loss. And we obtained optimal data of 350 mA driver current. It is important to distance between power MOSFET and driver ICs. If the distance was increased, the temperature of package was decreased. And so we obtained optimal data of 3.7 mm distance between power MOSFET and driver ICs. Finally, we fabricated real package and we analyzed the electrical characteristics. We obtained constant 35 V output voltage and 80% efficiency.

An Improvement of Distance Relay Technique Reliability using Elman Network (Elman Network를 이용한 거리계전기법의 신뢰성 향상)

  • Jung, H.S.;Lee, J.J.;Shin, M.C.;Lee, B.K.;Park, C.W.;Jang, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.212-214
    • /
    • 2000
  • The distance relay technique used for transmission line protection operates overreach and underreach to the self protection region because the power system becomes complex and fault conditions are different. To solve these problems, this paper describes new technique to set the reliable self protection lesion. The trip region of the quadrilateral distance relay is set by training of multi layer recurrent elman network. The proposed network is able to reach the trip zone for the fault impedance, fault initial angle and source impedance variance correctly.

  • PDF

2-D object recognition using distance transform on morphological skeleton (형태학적 골격에서의 거리 변환을 이용한 2차원 물체 인식)

  • 권준식;최종수
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.7
    • /
    • pp.138-146
    • /
    • 1996
  • In this paper, w epropose a new mehtod to represent the shape and to recognize the object. The shape description and the matching is implemented by using the distance transform on the morphological skeleton. The employed distance transform is the chamfer (3,4) distance transform, because the chamfer distance transform (CDT) has an approximate value to the euclidean distance. The 2-D object can be represented by means of the distribution of the distance transform on the morphological skeleton, the number of skeletons, the sum of the CDT, and the other features are employed as the mtching parameters. The matching method has the invariant features (rotation, translation, and scaling), and then the method is used effectively for recognizing the differently-posed objects and/or marks of the different shape and size.

  • PDF

Standardization of Cautious blasting (정밀발파의 표준화)

  • Huh Ginn
    • Explosives and Blasting
    • /
    • v.8 no.3
    • /
    • pp.3-13
    • /
    • 1990
  • First ot of all, under given condition such as bit gage of 36mm Drill bit with right class of jack-leg-experimental test carried out from two face of Bench, firing of each hole brought 90 degree Angle face and them measured length of Burden and charged ammount of powder as following. $ca=\frac{A}{SW}$ A=Activated Area A=nd i=m S=Peripheral length of charged, room Ca=Rock Coeffiecency d: di=Hole diameter When constructed subway of Seoul in 1980 the blasting works increased complaint of ground vibration, in order to prevent the damage to structures. Some empirical equations were made as follows on condition with Jackleg Drill (Bit Gage 36mm) and within 30 meter distance between blasting site and structures. $V=K(D/W)^{-n}$ N=1.60 - 1.78 K= 48 - 138 Project is one of contineous works to above a determination of empirical equation on the cautious blasting vibration with Crawler Drill (70-75mm) in long distance. $V=41(D/\sqrt[3]{W})^{-1.41}$ $30m\le{D}\le{100m}$ $V=124(D/\sqrt[3]{W})^{-1.66}$ $100m\le{D}\le{285m}$.

  • PDF

Demosaicing Method for Digital Cameras with White-RGB Color Filter Array

  • Park, Jongjoo;Jang, Euee Seon;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.164-173
    • /
    • 2016
  • Demosaicing, or color filter array (CFA) interpolation, estimates missing color channels of raw mosaiced images from a CFA to reproduce full-color images. It is an essential process for single-sensor digital cameras with CFAs. In this paper, a new demosaicing method for digital cameras with Bayer-like W-RGB CFAs is proposed. To preserve the edge structure when reproducing full-color images, we propose an edge direction-adaptive method using color difference estimation between different channels, which can be applied to practical digital camera use. To evaluate the performance of the proposed method in terms of CPSNR, FSIM, and S-CIELAB color distance measures, we perform simulations on sets of mosaiced images captured by an actual prototype digital camera with a Bayer-like W-RGB CFA. The simulation results show that the proposed method demosaics better than a conventional one by approximately +22.4% CPSNR, +0.9% FSIM, and +36.7% S-CIELAB distance.