• Title/Summary/Keyword: w-distance

Search Result 910, Processing Time 0.023 seconds

Analysis on Improving Power of Thermal Radiation Shield in Low Pressure Chamber of AMTEC (AMTEC내 저압용기에서의 열복사차단막 형상에 따른 발전량 향상 해석)

  • Chung, Won-Sik;Chi, Ri-Guang;Lee, Wook-Hyun;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.54-62
    • /
    • 2016
  • The most efficient system for converting heat to electricity, AMTEC (Alkali Metal Thermal-to-Electric Convertor), is a device that directly converts heat energy to electricity using an alkali metal (sodium) as the working fluid. The AMTEC consists of a low pressure chamber, high pressure chamber, BASE (Beta-Alumina Solid Electrolyte), and artery wick. The main heat loss of the AMTEC system occurs in the low pressure chamber. A high power generation rate is thought to be obtainable by using a high temperature in the BASE. Therefore, to reduce the radiation heat loss, 6 types of radiation shields were examined to reduce the radiative heat loss in the low pressure chamber. The power generation rate of the AMTEC varied depending on the shape of the radiation shield. CFD (Computational Fluid Dynamics) analyses were carried out to optimize the shape of the radiation shield. As a result, the optimum radiation shield was found to consist of a curvature formed at the vertical point, in which case the dimensionless temperature (condenser temperature/BASE temperature) is approximately 0.665 and the maximum power generated is calculated to be 17.69W. Increasing the distance beween the BASE and condenser leads to an increase in the power generated, and the power generated with the longest distance was 17.58 W. The shields with multiple holes and multiple horizontal layers showed power reduction rates of 0.91 W and 2.06 W, respectively.

Data Transmission System from Distant Area Using SD-Card and Ethernet (SD 카드와 이더넷을 이용한 원격지 데이터 전송시스템)

  • Jo, Heung-Kuk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.381-385
    • /
    • 2010
  • An aging Society solitary life old mans are increasing. The nurses have to visit old mans and must confirm their disease, because they do not act well. It is very difficult to take care old man, because the number of Nurses are small. This problem is solved by collection of data about condition of old mans from long distance. Data communication with Ethernet have benefit to collection of measurement of old man's condition. The Data storage system an long distance place are storaged data and after several day data was transmitted to the DB over the Ethernet. For Miniaturization of such system the system must be OS-less Embedded Ethernet Server system. Such system manages the file management system only with H/W. The Storage device is used SD-card. SD Card is small size and operates with small power. By using 512MB sd memory card, it is possible to storage during 5~6 years, 10 byte of temperature value per second. In this paper, we make a Embedded Ethernet Server using W3100A, Atmega128 MCU and data stroage device using SD-Card. This system operates with O/S-less Embedded Ethernet Server. We talk about file System, Storage and Ethernet. We explained about MCU Atmega128, Interface between LAN LSIand W3100A, Interface between W3100A and Phyceiver RTL8201, data I/O between MCU and SD-Card and File System. We shows the experiment device and result of monitoring.

  • PDF

A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region (최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구)

  • Kim, J.K.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF

Study on the Structures of the Nozzle for the Spray (분무기용(噴霧機用) Nozzle의 구조(構造)에 관한 연구(硏究))

  • Lee, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.18 no.2
    • /
    • pp.100-109
    • /
    • 1993
  • The aim of this study was to provide the reasonable data for design of the nozzle which produces finer droplets on the same level of the effective travel distance or which transports droplets to the farther target on the reasonable atomization in comparison with the commercial nozzles being used much in Korean rural areas. Newly designed twin-fluid atomizers with some commercial nozzles were tested in this study, and their results were as follows : 1. The characteristics of the spray deposit distribution of No.1 nozzles for farther target were nearly same in the near or nearer travel distance less than 8m. Therefore it was reasonable to combine the characteristics of the spray deposit distributions of No.2 and No.3 nozzles to those of No.1 nozzle. 2. The effective travel distance was increased with increase of the sectional area of the jet ligament, and the maximum effective travel distance was reached to about 17m. 3. The droplet size was increased with increase of the sectional area of the jet ligament, and the maximum droplet size was produced in the front of the point of the maximum spray deposit distribution. 4. The atomization was excellent in the twin-fluid atomizer in comparison with the hydraulic atomizer and also the effective travel distances were nearly same level in both atomizers.

  • PDF

Near-IR TRGB Distance Modulus of Dwarf Irregular Galaxy IC 1613

  • Jung, M.Y.;Chun, S.H.;Chang, C.R.;Han, M.;Lim, D.;Han, W.;Sohn, Y.J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.421-424
    • /
    • 2009
  • The $JHK_S$ magnitudes of the red giant branch tip (TRGB) and the distance moduli of the nearby dwarf irregular galaxy IC 1613 have been determined from the near-infrared luminosity functions (LFs) of the resolved stars in the galaxy. Applying a Savitzky-Golay filtering, we derived the second derivatives of the LFs, and estimated the apparent magnitudes of the TRGB as $m_J\;=\;19.1$, $m_H\;=\;18.4$, and $m_{Ks}\;=\;18.0$. The mean values of the theoretical absolute magnitudes of the TRGB were measured by using the Yonsei-Yale isochrones with a metallicity range of -2.1 < [Fe/H] < -0.5 and age of 12 Gyr. The derived values of near-infrared TRGB distance moduli for IC 1613 are (m - M) = $24.12{\pm}0.25$, $24.20{\pm}0.44$, and $24.00{\pm}0.52$ for J, H, and $K_S$ bands, respectively.

Comparison of Experimental and FDS Data for Calculating Heat-Affected Range in Forest Fires (산불 열영향 범위 산정을 위한 실험 및 FDS 데이터 비교)

  • Kim, H.S.;Kang, Y.J.;Kim, J.H.;Kim, K.H.;Lee, B.D.;Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • This research deals with the combustion experiment of pine trees, which are the most representative species in Korea. Experimental data are compared with theoretical ones using Fire Simulation Program(FDS). It is considered that horizontal/vertical temperature distribution and radiant heat influence on adjacent areas in fire scenes. The linear function for separation distance to temperature was drawn by applying Stefan-Boltzmann's law; $y=112.13133{\times}({\sigma}T^4)^{-0.52916}$ for calculating the separation distance. In combustion experiment, the radiant heat came to $1.4{\sim}1.5kW/m^2$ in case of the separation distance by one meter. The numerical values mean that human body show the critical level of pain after one minute without a protective equipment.

Factory Layout and Aisle Structure Design Considering Dimension Constraints and Door Locations (형태 제약과 출입구를 고려한 설비 배치 및 복도 구조 디자인)

  • Chae-Bogk Kim
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.3
    • /
    • pp.58-66
    • /
    • 2003
  • The cut tree approach of Montreuil and Ratliff [16] and eigenvector approach [10] are used to automatically draw a feasible facility layout with aisle structure. The department arrangement can minimize an aisle distance criterion considering door locations and dimension constraints. The aisle distance is measured by the door to door distance between departments. An eigenvector and cut tree approaches [1] are implemented based on the branch and bound technique in Kim et al. [2] in order to obtain feasible layouts. Then, the algorithm to fix the door location of each department is developed. After the door locations are determined, the factory layout is evaluated in terms of aisle distance. The aisle structure is obtained by expanding the original layout. The solution is kept until we will find better factory layout. The proposed approach based on the branch and bound technique, in theory, will provide the optimal solution. If the runs are time and/or node limited, the proposed method is a strong heuristic. The technique is made further practical by the fact that the solution is constrained such that the rectangular shape dimensions length(l) and width(w) are fixed and a perfect fit is generated if a fit is possible.

Optimization of Double Gate Vertical Channel Tunneling Field Effect Transistor (DVTFET) with Dielectric Sidewall

  • WANG, XIANGYU;Cho, Wonhee;Baac, Hyoung Won;Seo, Dongsun;Cho, Il Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.2
    • /
    • pp.192-198
    • /
    • 2017
  • In this paper, we propose a novel double gate vertical channel tunneling field effect transistor (DVTFET) with a dielectric sidewall and optimization characteristics. The dielectric sidewall is applied to the gate region to reduced ambipolar voltage ($V_{amb}$) and double gate structure is applied to improve on-current ($I_{ON}$) and subthreshold swing (SS). We discussed the fin width ($W_S$), body doping concentration, sidewall width ($W_{side}$), drain and gate underlap distance ($X_d$), source doping distance ($X_S$) and pocket doping length ($X_P$) of DVTFET. Each of device performance is investigated with various device parameter variations. To maximize device performance, we apply the optimum values obtained in the above discussion of a optimization simulation. The optimum results are steep SS of 32.6 mV/dec, high $I_{ON}$ of $1.2{\times}10^{-3}A/{\mu}m$ and low $V_{amb}$ of -2.0 V.