Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.

Image-based Absorbed Dosimetry of Radioisotope (영상기반 방사성동위원소 흡수선량 평가)

  • Park, Yong Sung;Lee, Yong Jin;Kim, Wook;Ji, Young Hoon;Kim, Kum Bae;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.86-92
    • /
    • 2016
  • An absorbed dose calculation method using a digital phantom is implemented in normal organs. This method cannot be employed for calculating the absorbed dose of tumor. In this study, we measure the S-value for calculating the absorbed dose of each organ and tumor. We inject a radioisotope into a torso phantom and perform Monte Carlo simulation based on the CT data. The torso phantom has lung, liver, spinal, cylinder, and tumor simulated using a spherical phantom. The radioactivity of the actual absorbed dose is measured using the injected dose of the radioisotope, which is Cu-64 73.85 MBq, and detected using a glass dosimeter in the torso phantom. To perform the Monte Carlo simulation, the information on each organ and tumor acquired using the PET/CT and CT data provides anatomical information. The anatomical information is offered above mean value and manually segmented for each organ and tumor. The residence time of the radioisotope in each organ and tumor is calculated using the time activity curve of Cu-64 radioactivity. The S-values of each organ and tumor are calculated based on the Monte Carlo simulation data using the spatial coordinate, voxel size, and density information. The absorbed dose is evaluated using that obtained through the Monte Carlo simulation and the S-value and the residence time in each organ and tumor. The absorbed dose in liver, tumor1, and tumor2 is 4.52E-02, 4.61E-02, and 5.98E-02 mGy/MBq, respectively. The difference in the absorbed dose measured using the glass dosimeter and that obtained through the Monte Carlo simulation data is within 12.3%. The result of this study is that the absorbed dose obtained using an image can evaluate each difference region and size of a region of interest.

Evaluation of Antidepressant Drug Effect in a Depressive Animal Model by Proton MR Spectroscopy (양성자 자기공명분광법을 이용한 우울증 동물모델에서의 항우울제 약물 효능 평가)

  • Kim, Sang-Young;Choi, Chi-Bong;Lee, Sung-Ho;Woo, Dong-Cheol;Yoon, Seong-Ik;Hong, Kwan-Soo;Lee, Hyun-Sung;Cheong, Chae-Joon;Jee, Bo-Keun;Hong, Sung-Tak;Kim, Hwi-Yool;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • In this study, we observed the alteration of choline signal intensity in hippocampus region of the depressive rat model induced by forced swimming test (FST). The purpose of this study was to evaluate the antidepressant efficacy in the depressive animal model using MR spectroscopy. Fourteen experimentally naive male Sprague-Dawley rats weighting $160{\sim}180\;g$ were used as subjects. Drug injection group was exposed to the FST except for control group. The drugs were administered subcutaneously (SC) in a volume equivalent to 2ml/kg. And three injections were administered 23, 5, and 1h before beginning the given test. 1H MR spectra were obtained with use of a point resolved spectroscopy (PRESS) localization sequence performed according to the following parameters: repetition time, 2500 ms; echo time, 144 ms; 512 average; 2048 complex data points; voxel dimensions, $1.5{\times}2.5{\times}2.5\;mm^3$ ; acquisition time, 25min. There were no differences in NAA/Cr and Cho/Cr ratio between the right and the left hippocampus both normal control rats and antidepressant-injected rats. Also, no differences were observed in NAA/Cr and Cho/Cr ratio between the normal control rats and the antidepressant-injected rats both the right and the left hippocampus. In this study, we found the recovery of choline signals in the depressive animal model similar to normal control groups as injecting desipramine-HCl which was antidepressant causing anti-immobility effects. Thus, we demonstrated that MR spectroscopy was able to aid in evaluating the antidepressant effect of desipramine-HCl.

  • PDF

Effect of GB 34-GB 39 Electro-acupuncture on Regional Cerebral Blood Flow in Stroke Patients and Normal Volunteers Evaluated by $^{99m}Tc-ECD$ SPECT (양릉천-현종 전침치료가 뇌경색환자 및 정상인의 뇌혈류에 미치는 영향 - SPECT와 SPM을 이용한 연구 -)

  • Han, Jin-An;Jeong, Dong-Won;Bae, Hyung-Sup;Park, Sung-Uk;Jung, Woo-Sang;Park, Jung-Mee;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Kim, Deok-Yoon;Moon, Sang-Kwan
    • The Journal of Korean Medicine
    • /
    • v.27 no.3 s.67
    • /
    • pp.187-200
    • /
    • 2006
  • Objectives: Acupuncture has been applied in Asia for thousands of years, especially to rehabilitation after stroke. It has been reported that acupuncture increased cerebral blood supply and stimulated the functional activity of brain nerve cells shown by using brain imaging techniques. This study was to evaluate the effect of GB 34-GB 39 electro-acupuncture (EA) on regional cerebral blood flow (rCBF) in stroke patients and normal volunteers using single photon emission computed tomography (SPECT). Methods: The study procedure was divided into two parts: patients and volunteers studies. For the patients study, ten ischemic stroke patients (3 males, 7 females, mean age $68.5{\pm}8.9$ years old) were selected. Baseline brain SPECT was done with triple head gamma camera (MultiSPECT3, Siemens, USA) after intravenous administration of 1,110 MBq of $^{99m}Tc-ECD$. Fifteen-minute EA at GB 34 and GB 39 were applied on the affected limb. The same dose of $^{99m}Tc-ECD$ was injected during the EA, and the second set of SPECT images wasobtained. Using the computer software (ICON 7.1, Siemens, USA), 3 SPECT slices (upper, middle, lower) surrounding the brain lesion were selected and each slice was divided into 10-16 brain regions. Asymmetry indexes (AI) were analyzed in each brain region. We regarded over 10% changes of AI between before and after EA as significance. For the volunteers study, 10 healthy human volunteers (5 males, 5 females, mean age $28.1{\pm}6$ years old) were selected. In the resting state, $^{99m}Tc-ECD$ brain SPECT scans were performed. On the 7th day after the resting examination, 15 minute EA was applied at GB 34 and GB 39 on the right side of the subjects. Immediately after EA, the second SPECT images were obtained inthe same manner as the resting state. Significant increases and decreases of rCBF after EA were estimated by comparing their SPECT images with those of the resting state using paired t statistics at every voxel, which were analyzed by statistical parametric mapping with a threshold of p = 0.01, uncorrected (extent threshold: k=100 voxels). Results: In stroke patients, six of the eight (75%) had significantly increased perfusion in post-acupuncture scans compared to their baseline state. In normal volunteers, GB 34-GB GB EA increased rCBF in both hemispheres including right ventral posterior cingulate (Brodmann area (BA) 23), left superior temporal, anterior transverse temporal (BA 22, 41), left parastriate, peristriate (BA 18, 19), right occipitotemporal, angular (BA 37, 39), left rostral postcentral, caudal postcentral and preparietal (BA 2, 3, 5). However GB 34-GB 39 EA decreased rCBF in the right hemisphere including triangular and middle frontal lobes. Conclusions: The results demonstrated that OB 34-GB 39 EA increased cerebral perfusion in ischemic stroke patients and increased rCBF grossly in temporal lobes of normal volunteers. It is also suggested that there may be a correlation between the GB meridian and the territory of the middle cerebral artery.

  • PDF

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Comparison of rCBF between Patients with Medial Temporal Lobe Epilepsy and Normal Controls using ${H_2}^{15}O\;PET$ (내측 측두엽 간질환자와 정상인의 ${H_2}^{15}O\;PET$을 이용한 뇌 혈류량 비교)

  • Kang, Eun-Joo;Lee, Jae-Sung;Nam, Hyun-Woo;Lee, Sang-Kun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.155-165
    • /
    • 2002
  • Purpose: The aim of this study was to identify the brain areas whose regional cerebral blood flow (rCBF) was changed in medial temporal lobe epilepsy (mTLE) using ${H_2}^{15}O-PET$. Materials and Methods: 12 patients with mTLE (6 left, 6 right mTLE) and 6 normal controls were scanned during a fixation baseline period and a sensory-motor condition where subjects pressed a button to an upward arrow. A voxel-based analysis using SPM99 software was peformed to compare the patient groups with the normal controls for the rCBF during fixation baseline period and for relative changes of rCBF during the sensory-motor task relative to fixation. Results: During the fixation baseline, a significant reduction of rCBF was found posterior insula bilaterally and right frontopolar regions in right mTLE patients compared to the normal controls. In left mTLE patients, the reduction was found in left frontopolar and temporal legions. During the sensory-motor task, rCBF increase over the fixation period, was reduced in left frontal and superior temporal legions in the right mTLE patients whereas in various areas of right hemisphere in left mTLE patients, relative to normal controls. However, the increased rCBF was also found in the left inferior parietal and anterior thalamic/fornix regions in both right and left mTLE patients compared to normal controls. Conclusion: Epilepsy induced changes were found not only in relative increase/decrease of rCBF during a simple sensory-motor control condition relative to a fixation rest condition but also in the relative rCBF distribution during the rest period.

Quantitative Evaluation of Regional Cerebral Blood Flow by Visual Stimulation in $^{99m}Tc-HMPAO$ Brain SPECT ($^{99m}Tc-HMPAO$ 뇌 SPECT에서 시각자극에 의한 국소 뇌 혈류변화의 정량적 검증)

  • Juh, Ra-Hyeong;Suh, Tae-Suk;Kwark, Chul-Eun;Choe, Bo-Young;Lee, Hyoung-Koo;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.166-176
    • /
    • 2002
  • Purpose: The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of $^{99m}Tc-HMPAO$ (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. Materials and Methods: The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and $^{99m}Tc-HMPAO$ SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the legion of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). Results: The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was $32.50{\pm}5.67%$. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Conclusion: Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

Investigation of the Correlation between Seoul Neuropsychological Screening Battery Scores and the Gray Matter Volume after Correction of Covariates of the Age, Gender, and Genotypes in Patients with AD and MCI (알츠하이머 치매 및 경도인지기능장애 환자에서 나이, 성별, 유전자형을 고려한 뇌 회백질 부피와 표준신경심리검사와의 상관관계 연구)

  • Lee, Seung-Yeon;Yoon, Soo-Young;Kim, Min-Ji;Rhee, Hak Young;Ryu, Chang-Woo;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.294-307
    • /
    • 2013
  • Purpose : To investigate the correlations between Seoul Neuropsychological Screening Battery (SNSB) scores and the gray matter volumes (GMV) in patients with Alzheimer's disease (AD) and mild cognitive impairment (MCI) and cognitively normal (CN) elderly subjects with correcting the genotypes. Materials and Methods: Total 75 subjects were enrolled with 25 subjects for each group. The apolipoprotein E (APOE) epsilon genotypes, SNSB scores, and the 3D T1-weighted images were obtained from all subjects. Correlations between SNSB scores and GMV were investigated with the multiple regression method for each subject group using both voxel-based and region-of-interest-based analyses with covariates of age, gender, and the genotype. Results: In the AD group, Rey Complex Figure Test (RCFT) delayed recall scores were positively correlated with GMV. In the MCI group, Seoul Verbal Learning Test (SVLT) scores were positively correlated with GMV. In the CN group, GMV negatively correlated with Boston Naming Test (K-BNT) scores and Mini-Mental State Examimation (K-MMSE) scores, but positively correlated with RCFT scores. Conclusion: When we used covariates of age, gender, and the genotype, we found statistically significant correlations between some SNSB scores and GMV at some brain regions. It may be necessary to further investigate a longitudinal study to understand the correlation.