• 제목/요약/키워드: von-mises

검색결과 694건 처리시간 0.027초

탄성지반상에 놓인 철근 콘크리트 축대칭 쉘의 정적 및 동적 해석(IV) -축대칭 쉘의 동적 응답에 대한 철근의 영향을 중심으로- (Static and Dynamic Analysis of Reinforced Concrete Axisymmetric Shell on the Elastic Foundation -Effect of Steel on the Dynamic Response-)

  • 조진구
    • 한국농공학회지
    • /
    • 제39권4호
    • /
    • pp.106-113
    • /
    • 1997
  • Dynamic loading of structures often causes excursions of stresses well into the inelastic range, and the influence of the geometric changes on the dynamic response is also significant in many cases. Therefore, both material and geometric nonlinearity effects should be considered in case that a dynamic load acts on the structure. A structure in a nuclear power plant is a structure of importance which puts emphasis on safety. A nuclear container is a pressure vessel subject to internal pressure and this structure is constructed by a reinforced concrete or a pre-stressed concrete. In this study, the material nonlinearity effect on the dynamic response is formulated by the elasto-viscoplastic model highly corresponding to the real behavior of the material. Also, the geometrically nonlinear behavior is taken into account using a total Lagrangian coordinate system, and the equilibrium equation of motion is numerically solved by a central difference scheme. The constitutive relation of concrete is modeled according to a Drucker-Prager yield criterion in compression. The reinforcing bars are modeled by a smeared layer at the location of reinforcements, and the steel layer model under Von Mises yield criteria is adopted to represent an elastic-plastic behavior. To investigate the dynamic response of a nuclear reinforced concrete containment structure, the steel-ratios of 0, 3, 5 and 10 percent, are considered. The results obtained from the analysis of an example were summarized as follows 1. As the steel-ratio increases, the amplitude and the period of the vertical displacements in apex of dome decreased. The Dynamic Magnification Factor(DMF) was some larger than that of the structure without steel. However, the regular trend was not found in the values of DMF. 2. The dynamic response of the vertical displacement and the radial displacement in the dome-wall junction were shown that the period of displacement in initial step decreased with the steel-ratio increases. Especially, the effect of the steel on the dynamic response of radial displacement disapeared almost. The values of DMF were 1.94, 2.5, 2.62 and 2.66, and the values increased with the steel-ratio. 3. The characteristics of the dynamic response of radial displacement in the mid-wall were similar to that of dome-wall junction. The values of DMF were 1.91, 2.11, 2.13 and 2.18, and the values increased with the steel-ratio. 4. The amplitude and the period of the hoop-stresses in the dome, the dome-wall junction, and the mid-wall were shown the decreased trend with the steel-ratio. The values of DMF were some larger than those of the structure without steel. However, the regular trend was not found in the values of DMF.

  • PDF

한국형 기준 처분 환경에서의 PWR 사용후핵연료 처분용기의 구조적 안전성 해석 (Structural Analysis of the Canister for PWR Spent Fuels under the Korean Reference Disposal Conditions)

  • 최희주;이양;최종원;권영주
    • 방사성폐기물학회지
    • /
    • 제4권3호
    • /
    • pp.301-309
    • /
    • 2006
  • 한국형처분시스템에 이용될 가압경수로형 사용후핵연료를 위한 KDC-1 처분용기를 개발하였다. 처분용기 안전성 평가의 일환으로서 처분용기에 대한 구조적 안전성을 평가하였다. 처분용기의 구조적 안전성은 처분조건과 취급조건 2가지로 구분하여 평가하였다. 처분조건에서는 3가지 하중 조건, 정상하중 조건, 비정상 하중 조건, 암반의 움직임을 고려하였다. 처분조건에서 평가 결과 3가지 조건에 대해 모두 안전계수가 설계기준보다 컸다. 취급조건에서는 처분용기 취급 중 구조해석과 처분용기 낙하 사고시 구조해석을 수행하였다. 취급장비 고장 시나리오 평가결과 1개 혹은 2개의 취급 장치가 고장을 일으켰을 때도 취급장비를 계속 운전하는 것이 가능하였다. 처분용기 낙하 시나리오에서는 계산결과 최대 응력은 0.762 MPa 이었으며, 이 값은 주철의 항복응력과 비교하면 거의 무시할 수 있는 값이었다. 본 논문에서 제안한 KDC-1 처분용기에 대한 처분조건 및 취급조건에서의 구조해석 결과, 한국형처분시스템에서 고려하고 있는 조건에서 그 구조적 안전성을 확인하였다.

  • PDF

유한요소법을 이용한 대퇴 골두내 무혈성 괴사증의 다양한 수술적 기법에 대한 생체역학적 분석 (A Biomechanical Analysis of Various Surgical Procedures for Osteonecrosis of the Femoral Head using a Finite Element Method)

  • 김정성;이성재;신정욱;김용식;최재봉;김양수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.374-378
    • /
    • 1997
  • Operative procedures such as core drilling with and without fibular bone grafting have been recognized as the treatment methods for osteonecrosis of femoral head(ONFH) by delaying or preventing the collapse of the femoral head. In addition, core drilling with cementation using polymethylmethacrylate (PMMA) has been proposed recently as another surgical method. However, no definite treatment modality has been found yet while operative procedures remain controversial to many clinicians In this study, a finite element method(FEM) was employed to analyze and compare various surgical procedures of ONFH to provide a biomechanical insight. This study was based upon biomechanical findings which suggest stress concentration within the femoral head may facilitate the progression of the necrosis and eventual collapse. For this purpose, five anatomically relevant hip models were constructed in three dimensions : they were (1) intact(Type I), (2) necrotic(Type II), (3) core drilled only(Type III), (4) core drilled with fibular bone graft(Type IV), and (5) core drilled with cementation(Type V). Physiologically relevant loading were simulated. Resulting stresses were calculated. Our results showed that the volumetric percentage subjected to high stress in the necrotic cancellous region was greatest in the core drilled only model(Type III), followed by the necrotic(Type II), the bone graft (Type IV), and the cemented(Type V) models. Von Mises stresses at the tip of the graft(Type IV) was found to be twice more than those of cemented core(Type V) indicating the likelihood of the implant failure. In addition, stresses within the cemented core(Type V) were more evenly distributed and relatively lower than within the fibular bone graft(Type IV). In conclusion, our biomechanical analyses have demonstrated that the bone graft method(Type IV) and the cementation method(Type V) are both superior to the core decompression method(Type III) by reducing the high stress regions within the necrotic cancellous bone. Also it was found that the core region filled with PMMA(Type V) provides far smoother transfer of physiological load without causing the concentration of malignant stresses which may lead to the failure than with the fibular bone graft(Type IV). Therefore, considering the above results along with the degree of difficulties and risk of infection involved with preparation of the fibular bone graft, the cementation method appears to be a promising surgical treatment for the early stage of osteonecrosis of the femoral head.

  • PDF

초박형 FPCB의 유연 내구성 연구 (Flexible Durability of Ultra-Thin FPCB)

  • 정훈선;은경태;이은경;정기영;최성훈;좌성훈
    • 마이크로전자및패키징학회지
    • /
    • 제21권4호
    • /
    • pp.69-76
    • /
    • 2014
  • 본 연구에서는 스퍼터링 공정으로 제작된 FCCL(flexible copper clad laminate)을 이용하여 초박형 FPCB를 개발하였다. 또한 구리 박막과 폴리이미드 기판의 접착력을 향상시키기 위한 NiMoNb 접착층을 적용하였다. 개발된 초박형 FPCB의 기계적 내구성과 유연성은 인장, 비틀림 및 굽힘 피로 수명시험을 이용하여 검증하였다. 인장 시험 결과 초박형 FPCB는 약 7% 까지 인장이 가능하였으며, 비틀림 각도 $120^{\circ}$ 까지의 내구성과 유연성을 갖고 있음을 알 수 있었다. 또한 초박형 FPCB는 10,000회의 굽힘 피로시험에도 파괴가 발생하지 않았다. 수치해석에 의한 응력 및 변형율의 계산 결과, 인장 시에 초박형 FPCB에 걸리는 최대 응력 및 변형률은 기존 FPCB에 비하여 크게 차이가 나지 않음을 알 수 있었다. 결론적으로 초박형 FPCB의 강건성은 기존 FPCB에 비하여 약간 열세이나, 제품에 적용하기에는 충분한 강건성과 신뢰성을 갖고 있다고 판단된다.

Effect of implant- and occlusal load location on stress distribution in Locator attachments of mandibular overdenture. A finite element study

  • Alvarez-Arenal, Angel;Gonzalez-Gonzalez, Ignacio;deLlanos-Lanchares, Hector;Martin-Fernandez, Elena;Brizuela-Velasco, Aritza;Ellacuria-Echebarria, Joseba
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권5호
    • /
    • pp.371-380
    • /
    • 2017
  • PURPOSE. The aim of this study is to evaluate and compare the stress distribution in Locator attachments in mandibular two-implant overdentures according to implant locations and different loading conditions. MATERIALS AND METHODS. Four three-dimensional finite element models were created, simulating two osseointegrated implants in the mandible to support two Locator attachments and an overdenture. The models simulated an overdenture with implants located in the position of the level of lateral incisors, canines, second premolars, and crossed implant. A 150 N vertical unilateral and bilateral load was applied at different locations and 40 N was also applied when combined with anterior load at the midline. Data for von Mises stresses in the abutment (matrix) of the attachment and the plastic insert (patrix) of the attachment were produced numerically, color-coded, and compared between the models for attachments and loading conditions. RESULTS. Regardless of the load, the greatest stress values were recorded in the overdenture attachments with implants at lateral incisor locations. In all models and load conditions, the attachment abutment (matrix) withstood a much greater stress than the insert plastic (patrix). Regardless of the model, when a unilateral load was applied, the load side Locator attachments recorded a much higher stress compared to the contralateral side. However, with load bilateral posterior alone or combined at midline load, the stress distribution was more symmetrical. The stress is distributed primarily in the occlusal and lateral surface of the insert plastic patrix and threadless area of the abutment (matrix). CONCLUSION. The overdenture model with lateral incisor level implants is the worst design in terms of biomechanical environment for the attachment components. The bilateral load in general favors a more uniform stress distribution in both attachments compared to a much greater stress registered with unilateral load in the load side attachments. Regardless of the implant positions and the occlusal load application site, the stress transferred to the insert plastic is much lower than that registered in the abutment.

하악각 골절의 치료 방법에 따른 하악골의 응력 분포 및 변위에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DISPLACEMENT IN MANDIBLE ACCORDING TO TREATMENT MODALITIES OF MANDIBULAR ANGLE FRACTURES)

  • 구제훈;김일규;장재원;양정은;사시카라 바라라만;왕붕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권3호
    • /
    • pp.207-217
    • /
    • 2010
  • The purpose of this study was to evaluate the effects of the stress distribution and displacement in mandible according to treatment modalities of mandibular angle fractures, using a three dimensional finite element analysis. A mechanical model of an edentulous mandible was generated from 3D scan. A 100-N axial load and four masticatory muscular supporting system were applied to this model. According to the number, location and materials of titanium and biodegradable polymer plates, the experimental groups were divided into five types. Type I had a single titanium plate in the superior border of mandibular angle, type II had two titanium plates in the superior tension border and in the inferior compression border of mandibular angle, type III had a single titanium plate in the ventral area of mandibular angle, type IV had a single biodegradable polymer plate in the superior border of mandibular angle, type V had a single biodegradable polymer plate in the ventral area of mandibular angle. The results obtained from this study were follows: 1. Stress was concentrated on the condylar neck of the fractured side except Type III. 2. The values of von-Mises stress of the screws were the highest in the just-posterior screw of the fracture line, and in the just-anterior screw of Type III. 3. The displacement of mandible in Type III was 0.04 mm, and in Type I, II, IV, and V were 0.10 mm. 4. The plates were the most stable in the ventral area of mandibular angle (Type III, V). In conclusion, the ventral area of mandibular angle is the most stable location in the fixation of mandibular angle fractures, and the just- posterior and/or the just-anterior screws of the fracture line must be longer than the other, and surgeons have to fix accurately these screws, and the biodegradable polymer plate also was suitable for the treatment of mandible angle fracture.

하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석 (Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load)

  • 배숙진;정재헌;정승미
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

유한요소 해석을 이용한 정형용 흉·요추 보조기의 형태에 따른 생체역학적 분석 (Biomechanical Analysis of Different Thoracolumbar Orthosis Designs using Finite Element Method)

  • 김영현;전성철;정덕영;이성재
    • 재활복지공학회논문지
    • /
    • 제6권1호
    • /
    • pp.45-50
    • /
    • 2012
  • 흉 요추 보조기는 후만증 관련 증상의 진행을 예방하고 통증을 완화시키기 위한 목적으로 노인성 후만증 환자의 재활을 위하여 이용되고 있다. 최근 다양한 형태의 흉 요추 보조기가 개발되고 있으나 생체역학적 효과에 관한 연구가 미흡한 실정이다. 따라서 본 연구에서는 세 가지 형태 (Type 1, one-connecting frame type; Type 2, two-connecting frame type; Type 3, all-in-one type)의 흉 요추 보조기와 몸통 (trunk)의 유한요소 모델을 구현하여 보조기 착용 후 운동성 변화에 따른 몸통에서의 압력 분포 및 보조기의 응력을 비교 분석하였다. 신전 운동 시 몸통에서 확인되는 압력의 분산은 일체형의 형태를 가지는 Type 3에 의해서 가장 고르게 이루어졌으며 connecting frame 형태의 Type 1과 Type 2의 압력 분포 패턴은 크게 차이가 나지 않았다. 보조기 착용에 따른 몸통의 운동성은 Type 2 ($11.3{\sim}13.9^{\circ}$), Type 1 ($12.1{\sim}15.4^{\circ}$)와 비교하여 Type 3 ($8.5{\sim}9.4^{\circ}$)에 의하여 가장 크게 제한되었다. 모든 Type의 보조기는 20% 미만의 파단 가능성을 보였다. 따라서, 보조기 착용에 따른 등압 분포 및 운동성의 결과로 미루어 볼 때, 일체형의 흉 요추 보조기가 후만증 환자 재활에 있어 높은 효과를 제공할 것으로 사료된다.

  • PDF

빌트인 양문형 냉장고 댐핑힌지의 구조해석 및 브래킷핀의 응력집중 저감을 위한 설계개선 (Structural Analysis of Damping Hinge for Built-in Side-by-Side Refrigerator and Design Improvement of Bracket Pin to Reduce Stress Concentration)

  • 이부윤
    • 한국산학기술학회논문지
    • /
    • 제21권1호
    • /
    • pp.373-379
    • /
    • 2020
  • 본 연구는 빌트인 양문형 냉장고의 도어를 최대개방각도로 열었을 때 발생하는 댐핑힌지의 응력해석과 피로수명 해석을 다룬다. 댐핑힌지의 초기설계안에 대하여 유한요소해석을 수행한 결과, 브래킷핀에서 상부원판과 원통이 직각을 이루는 기하학적 불연속 부위에서 국부적 응력집중이 발생하였고, 최대 von Mises 등가응력이 재료의 항복강도를 초과하였다. 이 최대응력 발생 위치는 시작품을 제작하여 수행한 도어개폐 내구시험 시에 파손된 브래킷핀의 부위와 일치하였으며, 응력해석 결과로부터 계산된 피로수명도 내구시험 결과와 정합성이 있는 것으로 나타났다. 브래킷핀의 초기설계 안에서 나타난 응력집중을 완화하기 위하여 브래킷핀의 형상을 변경하는 3가지 설계개선안을 도출하고 해석을 수행하여 안전성을 평가하였다. 설계개선안의 해석결과, 브래킷핀의 원판과 원통 사이에 필렛을 삽입하면 응력집중을 저감시키고 피로수명은 증가하는 것으로 나타났다. 또한 브래킷핀의 원판을 2단으로 변경하면 응력집중을 저감시키고 피로수명은 증가하는 것으로 나타났다. 결론적으로 가장 우수한 설계개선안은 브래킷핀의 원판을 2단으로 변경하고 반경이 큰 필렛을 삽입한 경우로서, 응력집중이 가장 작고 피로수명이 무한대인 것으로 판단된다.